Abstract:
PURPOSE:Medical imaging and in particular digital radiographic images offer a great deal of information to dentists in the clinical diagnosis and treatment processes on a daily basis. This paper presents a new method aimed to produce an accurate segmentation of dental implants and the crestal bone line in radiographic images. With this, it is possible computing several measures to biomechanical and clinical evaluation of dental implants positioning and evolution. METHODS:The proposed segmentation method includes two major steps: (1) the preprocessing that combine denoising filters, morphological operations and histogram threshold techniques and (2) the final segmentation involving made-to-measure adjusted and trained active shape models for detecting the precise location of the intended structures. RESULTS:Resulting measurements were compared to manual measurements made by experts on representative radiographs from patients. The calculated intraclass correlation coefficient was 0.75 and showed good reliability of the method, and the Bland-Altman analysis showed 95% of the values within the limits of agreement. The mean of the differences between the manual and method-driven measurements was 0.049 mm ([Formula: see text]) 95% CI, inferior to the established limit (0.15mm). CONCLUSIONS:It was demonstrated that the method achieved a precise segmentation of the intended structures. The validation process on standardized periapical radiographs showed good agreement between the manual measurements and the ones produced by the new method. Future work will be focused on making the method more robust to densitometry changes and to validate the method on non-standardized radiographs.
journal_name
Int J Comput Assist Radiol Surgauthors
Cunha P,Guevara MA,Messias A,Rocha S,Reis R,Nicolau PMdoi
10.1007/s11548-012-0802-6subject
Has Abstractpub_date
2013-09-01 00:00:00pages
711-21issue
5eissn
1861-6410issn
1861-6429journal_volume
8pub_type
杂志文章abstract:PURPOSE:Laser ablation of hard tissue is not completely understood until now and not modeled for computer-assisted microsurgery. A precise planning and simulation is an essential step toward the usage of microsurgical laser bone ablation in the operating room. METHODS:Planning the volume for laser bone ablation is bas...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-009-0303-4
更新日期:2010-03-01 00:00:00
abstract:PURPOSE:Fusion of pre/perioperative images and intra-operative images may add relevant information during image-guided procedures. In abdominal procedures, respiratory motion changes the position of organs, and thus accurate image guidance requires a continuous update of the spatial alignment of the (pre/perioperative)...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-015-1218-x
更新日期:2015-09-01 00:00:00
abstract:OBJECTIVE:Software-based devices have increasingly become an important part of several clinical scenarios. Due to their critical impact on human life, medical devices have very strict safety requirements. It is therefore necessary to apply verification methods to ensure that the safety requirements are met. Verificatio...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-013-0919-2
更新日期:2014-01-01 00:00:00
abstract:PURPOSE:Airway tree segmentation plays a pivotal role in chest computed tomography (CT) analysis tasks such as lesion localization, surgical planning, and intra-operative guidance. The remaining challenge is to identify small bronchi correctly, which facilitates further segmentation of the pulmonary anatomies. METHODS...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-020-02293-x
更新日期:2021-01-19 00:00:00
abstract:PURPOSE:The use of projector-based augmented reality (AR) in surgery may enable surgeons to directly view anatomical models and surgical data from the patient's surface (skin). It has the advantages of a consistent viewing focus on the patient, an extended field of view and augmented interaction. This paper presents an...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-013-0897-4
更新日期:2013-11-01 00:00:00
abstract:PURPOSE:Despite great advances in medical image segmentation, the accurate and automatic segmentation of endoscopic scenes remains a challenging problem. Two important aspects have to be considered in segmenting an endoscopic scene: (1) noise and clutter due to light reflection and smoke from cutting tissue, and (2) st...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-015-1331-x
更新日期:2016-08-01 00:00:00
abstract:PURPOSE:Prostate carcinoma is a commonly diagnosed cancer in men. Nonsurgical treatment of early stage prostate cancer is an important alternative. The use of MRI for tumor cryoablation is of particular interest: it offers lower morbidity compared with other localized techniques. However, the current manual procedure i...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-011-0558-4
更新日期:2011-11-01 00:00:00
abstract:PURPOSE:In this study, we propose a deep learning approach for assessment of gallbladder (GB) wall vascularity from images of laparoscopic cholecystectomy (LC). Difficulty in the visualization of GB wall vessels may be the result of fatty infiltration or increased thickening of the GB wall, potentially as a result of c...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-020-02285-x
更新日期:2021-01-01 00:00:00
abstract:PURPOSE:An augmented reality system to visualize a 3D preoperative anatomical model on intra-operative patient is proposed. The hardware requirement is commercial tablet-PC equipped with a camera. Thus, no external tracking device nor artificial landmarks on the patient are required. METHODS:We resort to visual SLAM t...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-016-1444-x
更新日期:2017-01-01 00:00:00
abstract:PURPOSE:Focal therapy in low-risk prostate cancer may provide the best balance between cancer control and quality of life preservation. As a minimally invasive approach performed under TRUS guidance, brachytherapy is an appealing framework for focal therapy. However, the contrast in TRUS images is generally insufficien...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-016-1380-9
更新日期:2016-06-01 00:00:00
abstract:PURPOSE:Objective determination of the orbital volume is important in the diagnostic process and in evaluating the efficacy of medical and/or surgical treatment of orbital diseases. Tools designed to measure orbital volume with computed tomography (CT) often cannot be used with cone beam CT (CBCT) because of inferior t...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-015-1228-8
更新日期:2016-01-01 00:00:00
abstract:PURPOSE:Laser range scanners (LRS) allow performing a surface scan without physical contact with the organ, yielding higher registration accuracy for image-guided surgery (IGS) systems. However, the use of LRS-based registration in laparoscopic liver surgery is still limited because current solutions are composed of ex...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-015-1309-8
更新日期:2016-08-01 00:00:00
abstract:PURPOSE:Interactive visualization is required to inspect and monitor the automatic segmentation of vessels derived from contrast-enhanced magnetic resonance angiography (CE-MRA). A dual-view visualization scheme consisting of curved planar reformation (CPR) and direct volume rendering (DVR) was developed for this purpo...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-010-0534-4
更新日期:2011-09-01 00:00:00
abstract:OBJECTIVE:The most commonly used imaging device for assessment of fracture reduction is the two-dimensional X-ray fluoroscope. Two recently introduced 3D fluoroscopic devices, the Siremobil ISO-C3D (Siemens) and the C-InSight (Mazor Surgical Technologies), enable the surgeon to obtain spatial information for the assess...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-011-0548-6
更新日期:2011-09-01 00:00:00
abstract:PURPOSE:Breast masses exhibit variability in margins, shapes, and dimensions, so their detection is a difficult task in mammographic computer-aided diagnosis. Mass detection is usually a two-step procedure: mass identification and false-positive reduction. A new method to automatically detect mass lesions in mammograph...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-011-0659-0
更新日期:2012-07-01 00:00:00
abstract:PURPOSE:Automatic segmentation of anatomical structures and lesions from medical ultrasound images is a formidable challenge in medical imaging due to image noise, blur and artifacts. In this paper we present a segmentation technique with features highly suited to use in noisy 3D ultrasound volumes and demonstrate its ...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-015-1239-5
更新日期:2016-01-01 00:00:00
abstract:BACKGROUNDS:Accurate three-dimensional (3D) models of lumbar vertebrae are required for image-based 3D kinematics analysis. MRI or CT datasets are frequently used to derive 3D models but have the disadvantages that they are expensive, time-consuming or involving ionizing radiation (e.g., CT acquisition). An alternative...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-010-0515-7
更新日期:2011-05-01 00:00:00
abstract:PURPOSE:Segmenting the cardiac ventricles in magnetic resonance (MR) images is required for cardiac function assessment. Numerous segmentation methods have been developed and applied to MR ventriculography. Quantitative validation of these segmentation methods with ground truth is needed prior to clinical use, but requ...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-010-0532-6
更新日期:2011-09-01 00:00:00
abstract:PURPOSE:The purpose of the present study is to apply kinetic analysis to investigate exercise-related changes in the metabolism of the skeletal muscle of the rat hindlimb by [[Formula: see text]]acetate positron emission tomography and computed tomography (PET/CT). METHODS:Contractions were induced in Wistar rats' lef...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-015-1260-8
更新日期:2016-05-01 00:00:00
abstract:PURPOSE:This article investigates the current state of the art of the use of auditory display in image-guided medical interventions. Auditory display is a means of conveying information using sound, and we review the use of this approach to support navigated interventions. We discuss the benefits and drawbacks of publi...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章,评审
doi:10.1007/s11548-017-1547-z
更新日期:2017-10-01 00:00:00
abstract:PURPOSE:Regional infarction identification is important for heart disease diagnosis and management, and myocardial deformation has been shown to be effective for this purpose. Although tagged and strain-encoded MR images can provide such measurements, they are uncommon in clinical routine. On the contrary, cardiac CT i...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章,评审
doi:10.1007/s11548-016-1404-5
更新日期:2016-09-01 00:00:00
abstract:PURPOSE:The minimally invasive closure of the left atrial appendage is a promising alternative to anticoagulation for stroke prevention in patients suffering from atrial fibrillation. One of the challenges of this procedure is the correct positioning and the coaxial alignment of the tip of the catheter sheath to the im...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1752-4
更新日期:2018-06-01 00:00:00
abstract:PURPOSE:Morphological parameters are very important for predicting aneurysm rupture. However, due to geometric radiographic distortion and plane/angle selection bias, the traditional manual measurements (MM) of aneurysm morphology are inaccurate and suffer from severe variability. Our study is to evaluate the accuracy ...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-020-02218-8
更新日期:2020-10-01 00:00:00
abstract:PURPOSE:Oral disorders such as temporomandibular joint disorders (TMD) and dry mouth are common and often require treatment. Maxillofacial massage is used as a complementary and alternative therapy for these disorders. We developed an oral rehabilitation robot that massages the maxillofacial tissues for this purpose. I...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-009-0383-1
更新日期:2010-01-01 00:00:00
abstract:PURPOSE:To evaluate the effect of image registration on the diagnostic performance of transfer learning (TL) using pretrained convolutional neural networks (CNNs) and three-phasic dynamic contrast-enhanced computed tomography (DCE-CT) for primary liver cancers. METHODS:We retrospectively evaluated 215 consecutive pati...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-019-01987-1
更新日期:2019-08-01 00:00:00
abstract:PURPOSE:Deep brain stimulation (DBS) is a surgical procedure for treating motor-related neurological disorders. DBS clinical efficacy hinges on precise surgical planning and accurate electrode placement, which in turn call upon several image processing and visualization tasks, such as image registration, image segmenta...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-014-1007-y
更新日期:2015-02-01 00:00:00
abstract:PURPOSE:Thermotherapy is a clinical procedure which delivers thermal energy to a target, and it has been applied for various medical treatments. Temperature monitoring during thermotherapy is important to achieve precise and reproducible results. Medical ultrasound can be used for thermal monitoring and is an attractiv...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1744-4
更新日期:2018-06-01 00:00:00
abstract:PURPOSE:Precise needle placement is an important task during several medical procedures. Ultrasound imaging is often used to guide the needle toward the target region in soft tissue. This task remains challenging due to the user's dependence on image quality, limited field of view, moving target, and moving needle. In ...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-016-1408-1
更新日期:2016-06-01 00:00:00
abstract:BACKGROUND:High-intensity focused ultrasound (HIFU) is a promising treatment method for many common cancers, including prostate cancer. Magnetic resonance image (MRI) guidance of HIFU permits targeting and monitoring of therapy. A prototype MRI-compatible positioning device that navigates a HIFU transducer was designed...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-013-0964-x
更新日期:2014-07-01 00:00:00
abstract:PURPOSE:Accurate vertebra detection and segmentation are essential steps for automating the diagnosis of spinal disorders. This study is dedicated to vertebra alignment measurement, the first step in a computer-aided diagnosis tool for cervical spine trauma. Automated vertebral segment alignment determination is a chal...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章,评审
doi:10.1007/s11548-013-0927-2
更新日期:2014-03-01 00:00:00