Abstract:
PURPOSE:Airway tree segmentation plays a pivotal role in chest computed tomography (CT) analysis tasks such as lesion localization, surgical planning, and intra-operative guidance. The remaining challenge is to identify small bronchi correctly, which facilitates further segmentation of the pulmonary anatomies. METHODS:A three-dimensional (3D) multi-scale feature aggregation network (MFA-Net) is proposed against the scale difference of substructures in airway tree segmentation. In this model, the multi-scale feature aggregation (MFA) block is used to capture the multi-scale context information, which improves the sensitivity of the small bronchi segmentation and addresses the local discontinuities. Meanwhile, the concept of airway tree partition is introduced to evaluate the segmentation performance at a more granular level. RESULTS:Experiments were conducted on a dataset of 250 CT scans, which were annotated by experienced clinical radiologists. Through the airway partition, we evaluated the segmentation results of the small bronchi compared with the state-of-the-art methods. Experiments show that MFA-Net achieves the best performance in the Dice similarity coefficient (DSC) in the intra-lobar airway and improves the true positive rate (TPR) by 7.59% on average. Besides, in the entire airway, the proposed method achieves the best results in DSC and TPR scores of 86.18% and 79.31%, respectively, with the consequence of higher false positives. CONCLUSION:The MFA-Net is competitive with the state-of-the-art methods. The experiment results indicate that the MFA block improves the performance of the network by utilizing multi-scale context information. More accurate segmentation results will be more helpful in further clinical analysis.
journal_name
Int J Comput Assist Radiol Surgauthors
Zhou K,Chen N,Xu X,Wang Z,Guo J,Liu L,Yi Zdoi
10.1007/s11548-020-02293-xsubject
Has Abstractpub_date
2021-01-19 00:00:00eissn
1861-6410issn
1861-6429pii
10.1007/s11548-020-02293-xpub_type
杂志文章abstract:PURPOSE:C-arm fluoroscopy is frequently used in clinical applications as a low-cost and mobile real-time qualitative assessment tool. C-arms, however, are not widely accepted for applications involving quantitative assessments, mainly due to the lack of reliable and low-cost position tracking methods, as well as adequa...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-013-0957-9
更新日期:2014-07-01 00:00:00
abstract:PURPOSE:We propose a fully automated method for detection and segmentation of the abnormal tissue associated with brain tumour (tumour core and oedema) from Fluid- Attenuated Inversion Recovery (FLAIR) Magnetic Resonance Imaging (MRI). METHODS:The method is based on superpixel technique and classification of each supe...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-016-1483-3
更新日期:2017-02-01 00:00:00
abstract:PURPOSE:Four-dimensional computed tomography (4DCT) images are often marred by artifacts that substantially degrade image quality and confound image interpretation. Human observation remains the standard method of 4DCT artifact evaluation, which is time-consuming and subjective. We develop a method to automatically ide...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-017-1538-0
更新日期:2017-09-01 00:00:00
abstract:PURPOSE:Distance measures are required for diagnoses, therapy decision and documentation. With today's high-resolution CT and MR imaging techniques, high- quality images have become possible. Yet, manual measurement can be tedious. We present a method for automatically determining different distance-based measures on s...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-010-0519-3
更新日期:2010-11-01 00:00:00
abstract:PURPOSE:Laparoscopic techniques have nowadays become a gold standard in many surgical procedures, but they imply a more difficult learning skills process. Simulators have a fundamental role in the formative stage of new surgeons. This paper presents the construct and face validity of SINERGIA laparoscopic virtual reali...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-010-0425-8
更新日期:2010-07-01 00:00:00
abstract:PURPOSE:Most ultrasound imaging systems assume a pre-determined sound propagation speed for imaging. However, a mismatch between assumed and real sound speeds can lead to spatial shift and defocus of ultrasound image, which may limit the applicability of ultrasound imaging. The estimation of real sound speed is importa...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-012-0690-9
更新日期:2012-11-01 00:00:00
abstract:PURPOSE:Sustained delivery of regenerative retinal therapies by robotic systems requires intra-operative tracking of the retinal fundus. We propose a supervised deep convolutional neural network to densely predict semantic segmentation and optical flow of the retina as mutually supportive tasks, implicitly inpainting r...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-020-02160-9
更新日期:2020-05-01 00:00:00
abstract:PURPOSE:We aimed to investigate the feasibility of predicting invasion carcinoma from ductal carcinoma in situ (DCIS) lesions diagnosed by preoperative core needle biopsy using radiomics signatures, clinical imaging characteristics, and breast imaging reporting and data system (BI-RADS) descriptors on mammography. MET...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1900-x
更新日期:2019-04-01 00:00:00
abstract:PURPOSE:The purpose of the present study is to apply kinetic analysis to investigate exercise-related changes in the metabolism of the skeletal muscle of the rat hindlimb by [[Formula: see text]]acetate positron emission tomography and computed tomography (PET/CT). METHODS:Contractions were induced in Wistar rats' lef...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-015-1260-8
更新日期:2016-05-01 00:00:00
abstract:PURPOSE:Calibration and registration are the first steps for augmented reality and mixed reality applications. In the medical field, the calibration between an RGB-D camera and a C-arm fluoroscope is a new topic which introduces challenges. METHOD:A convenient and efficient calibration phantom is designed by combining...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-015-1347-2
更新日期:2016-08-01 00:00:00
abstract:PURPOSE:In both structural and functional MRI, there is a need for accurate and reliable automatic segmentation of brain regions. Inconsistent segmentation reduces sensitivity and may bias results in clinical studies. The current study compares the performance of publicly available segmentation tools and their impact o...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-016-1433-0
更新日期:2016-11-01 00:00:00
abstract:PURPOSE:This paper presents a method to use the Smart Trocars-our new surgical instrument recognition system-or any accurate localization system of surgical instrument for acquiring intraoperative surface data. Complex laparoscopic surgeries need a proper guidance system which requires registering the preoperative data...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-017-1655-9
更新日期:2018-02-01 00:00:00
abstract:PURPOSE:Multimodality mammography using conventional 2D mammography and dynamic contrast-enhanced 3D magnetic resonance imaging (DCE-MRI) is frequently performed for breast cancer detection and diagnosis. Combination of both imaging modalities requires superimposition of corresponding structures in mammograms and MR im...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-014-0976-1
更新日期:2014-05-01 00:00:00
abstract:PURPOSE:To develop and validate an automated assessment of surgical performance (AASP) system for objective and computerized assessment of pelvic lymph node dissection (PLND) as an integral part of robot-assisted radical cystectomy (RARC) using console-feed videos recorded during live surgery. METHODS:Video recordings...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1881-9
更新日期:2019-04-01 00:00:00
abstract:PURPOSE:This paper presents a novel 3D multimodal registration strategy to fuse 3D real-time echocardiography images with cardiac cine MRI images. This alignment is performed in a saliency space, which is designed to maximize similarity between the two imaging modalities. This fusion improves the quality of the availab...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-019-02087-w
更新日期:2020-02-01 00:00:00
abstract:PURPOSE:Morphological parameters are very important for predicting aneurysm rupture. However, due to geometric radiographic distortion and plane/angle selection bias, the traditional manual measurements (MM) of aneurysm morphology are inaccurate and suffer from severe variability. Our study is to evaluate the accuracy ...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-020-02218-8
更新日期:2020-10-01 00:00:00
abstract:PURPOSE:Evaluation of circulating blood volume is important in assessing the status of patients. Although some studies have suggested that ultrasound images of the internal jugular vein (IJV) can be used for the analysis of circulating blood volume, accurate extraction of IJV is necessary to reduce errors. Therefore, t...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-013-0921-8
更新日期:2014-03-01 00:00:00
abstract:PURPOSE:We present a platform, GRAphical Pipeline Environment (GRAPE), to facilitate the development of patient-adaptive magnetic resonance imaging (MRI) protocols. METHODS:GRAPE is an open-source project implemented in the Qt C++ framework to enable graphical creation, execution, and debugging of real-time image anal...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-016-1495-z
更新日期:2017-03-01 00:00:00
abstract:PURPOSE:Molecular imaging is the visualization and identification of specific molecules in anatomy for insight into metabolic pathways, tissue consistency, and tracing of solute transport mechanisms. This paper presents the Molecular Imaging Data Grid (MIDG) which utilizes emerging grid technologies in preclinical mole...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-010-0524-6
更新日期:2011-03-01 00:00:00
abstract:PURPOSE:Patient-specific biomedical modeling of the breast is of interest for medical applications such as image registration, image guided procedures and the alignment for biopsy or surgery purposes. The computation of elastic properties is essential to simulate deformations in a realistic way. This study presents an ...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1803-x
更新日期:2018-10-01 00:00:00
abstract:PURPOSE:The accurate and automatic localisation of SEEG electrodes is crucial for determining the location of epileptic seizure onset. We propose an algorithm for the automatic segmentation of electrode bolts and contacts that accounts for electrode bending in relation to regional brain anatomy. METHODS:Co-registered ...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-018-1740-8
更新日期:2018-06-01 00:00:00
abstract:PURPOSE:A frequently mentioned lack of teleoperated surgical robots is the lack of haptic feedback. Haptics are not only able to mirror force information from the situs, but also to provide spatial guidance according to a surgical plan. However, superposition of the two haptic information can lead to overlapping and ma...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-020-02118-x
更新日期:2020-03-01 00:00:00
abstract:PURPOSE:Flexible surgical robot can work in confined and complex environments, which makes it a good option for minimally invasive surgery. In order to utilize flexible manipulators in complicated and constrained surgical environments, it is of great significance to monitor the position and shape of the curvilinear man...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-017-1672-8
更新日期:2018-02-01 00:00:00
abstract:PURPOSE:An augmented reality system to visualize a 3D preoperative anatomical model on intra-operative patient is proposed. The hardware requirement is commercial tablet-PC equipped with a camera. Thus, no external tracking device nor artificial landmarks on the patient are required. METHODS:We resort to visual SLAM t...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-016-1444-x
更新日期:2017-01-01 00:00:00
abstract:PURPOSE:Development and evaluation of an effective attachment device for a bilateral brain tumor resection robotic surgery system based on the sensory performance of the human index finger in order to precisely detect gripping- and pulling-force feedback. METHODS:First, a basic test was conducted to investigate the pe...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-017-1640-3
更新日期:2018-01-01 00:00:00
abstract:PURPOSE:Neoadjuvant chemotherapy (NAC) aims to minimize the tumor size before surgery. Predicting response to NAC could reduce toxicity and delays to effective intervention. Computational analysis of dynamic contrast-enhanced magnetic resonance images (DCE-MRI) through deep convolution neural network (CNN) has shown a ...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-020-02209-9
更新日期:2020-09-01 00:00:00
abstract:PURPOSE:Tele-operation of robotic surgery reduces the radiation exposure during the interventional radiological operations. However, endoscope vision without force feedback on the surgical tool increases the difficulty for precise manipulation and the risk of tissue damage. The shared control of vision and force provid...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-016-1425-0
更新日期:2017-01-01 00:00:00
abstract:PURPOSE:The purpose is to design and validate an anthropomorphic polyvinyl alcohol (PVA) liver phantom with respiratory motion to simulate needle-based interventions. Such a system can, for example, be used as a validation tool for novel needles. METHODS:Image segmentations of CT scans of four patients during inspirat...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-019-02029-6
更新日期:2019-12-01 00:00:00
abstract:PURPOSE:In the past decade, augmented reality systems have been expected to support surgical operations by making it possible to view invisible objects that are inside or occluded by the skull, hands, or organs. However, the properties of biological tissues that are non-rigid and featureless require a large number of d...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章
doi:10.1007/s11548-016-1458-4
更新日期:2016-12-01 00:00:00
abstract:PURPOSE:Accurate vertebra detection and segmentation are essential steps for automating the diagnosis of spinal disorders. This study is dedicated to vertebra alignment measurement, the first step in a computer-aided diagnosis tool for cervical spine trauma. Automated vertebral segment alignment determination is a chal...
journal_title:International journal of computer assisted radiology and surgery
pub_type: 杂志文章,评审
doi:10.1007/s11548-013-0927-2
更新日期:2014-03-01 00:00:00