Silver nanoparticle-induced degranulation observed with quantitative phase microscopy.

Abstract:

:Monitoring a degranulation process in a live mast cell is a quite important issue in immunology and pharmacology. Because the size of a granule is normally much smaller than the resolution limit of an optical microscope system, there is no direct real-time live cell imaging technique for observing degranulation processes except for fluorescence imaging techniques. In this research, we propose optical quantitative phase microscopy (QPM) as a new observation tool to study degranulation processes in a live mast cell without any fluorescence labeling. We measure the cell volumes and the cross sectional profiles (x-z plane) of an RBL-2H3 cell and a HeLa cell, before and after they are exposed to calcium ionophore A23187 and silver nanoparticles (AgNPs). We verify that the volume and the cross sectional line profile of the RBL-2H3 cell were changed significantly when it was exposed to A23187. When 50 microg/mL of AgNP is used instead of A23187, the measurements of cell volume and cross sectional profiles indicate that RBL-2H3 cells also follow degranulation processes. Degranulation processes for these cells are verified by monitoring the increase of intracellular calcium ([Ca(2+)](i)) and histamine with fluorescent methods.

journal_name

J Biomed Opt

authors

Yang W,Lee S,Lee J,Bae Y,Kim D

doi

10.1117/1.3470104

subject

Has Abstract

pub_date

2010-07-01 00:00:00

pages

045005

issue

4

eissn

1083-3668

issn

1560-2281

journal_volume

15

pub_type

杂志文章
  • Mechanically switchable polymer fibers for sensing in biological conditions.

    abstract::The area of in vivo sensing using optical fibers commonly uses materials such as silica and polymethyl methacrylate, both of which possess much higher modulus than human tissue. The mechanical mismatch between materials and living tissue has been seen to cause higher levels of glial encapsulation, scarring, and inflam...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.2.027001

    authors: McMillan S,Rader C,Jorfi M,Pickrell G,Foster EJ

    更新日期:2017-02-01 00:00:00

  • Dual/differential coherent anti-Stokes Raman scattering module for multiphoton microscopes with a femtosecond Ti:sapphire oscillator.

    abstract::In the last decade, coherent anti-Stokes Raman scattering (CARS) microscopy has emerged as a powerful multiphoton imaging technique offering label-free chemical sensitivity and high three-dimensional resolution. However, its widespread application in the life sciences has been hampered by the use of costly pulsed lase...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.6.066004

    authors: Li B,Borri P,Langbein W

    更新日期:2013-06-01 00:00:00

  • Real-time in vivo color Doppler optical coherence tomography.

    abstract::Color Doppler optical coherence tomography (CDOCT) is a functional extension of optical coherence tomography (OCT) that can image flow in turbid media. We have developed a CDOCT system capable of imaging flow in real time. Doppler processing of the analog signal is accomplished in hardware in the time domain using a n...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1428291

    authors: Rollins AM,Yazdanfar S,Barton JK,Izatt JA

    更新日期:2002-01-01 00:00:00

  • Laser trap ionization for identification of human erythrocytes with variable hemoglobin quantitation.

    abstract::An approach to an established technique that is potentially applicable for a more comprehensive understanding of the electrical properties of red blood cells (RBCs) is presented. Using a high-intensity gradient laser trap, RBCs can be singly trapped and consequentially ionized. The subsequent dynamics of the ionized c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.5.055005

    authors: Kelley M,Cooper J,Devito D,Mushi R,Aguinaga MDP,Erenso DB

    更新日期:2018-05-01 00:00:00

  • In-vivo imaging of murine tumors using complete-angle projection fluorescence molecular tomography.

    abstract::We interrogate the ability of free-space fluorescence tomography to image small animals in vivo using charge-coupled device (CCD) camera measurements over 360-deg noncontact projections. We demonstrate the performance of normalized dual-wavelength measurements that are essential for in-vivo use, as they account for th...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3149854

    authors: Deliolanis NC,Dunham J,Wurdinger T,Figueiredo JL,Tannous BA,Ntziachristos V

    更新日期:2009-05-01 00:00:00

  • Evaluating the use of optical coherence tomography for the detection of epithelial cancers in vitro.

    abstract::Optical coherence tomography (OCT) is a noninvasive imaging methodology that is able to image tissue to depths of over 1 mm. Many epithelial conditions, such as melanoma and oral cancers, require an invasive biopsy for diagnosis. A noninvasive, real-time, point of care method of imaging depth-resolved epithelial struc...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3652708

    authors: Smith LE,Hearnden V,Lu Z,Smallwood R,Hunter KD,Matcher SJ,Thornhill MH,Murdoch C,MacNeil S

    更新日期:2011-11-01 00:00:00

  • Monitoring of drug and stimulation induced cerebral blood flow velocity changes in rat sensory cortex using spectral domain Doppler optical coherence tomography.

    abstract::Doppler optical coherence tomography (DOCT) provides a novel method to measure blood flow velocity in vessels with diameter at micrometer scale. In this study, a developed spectral domain DOCT system is applied to monitor cerebral blood flow velocity changes in a rat. An animal model with a cranial window is used, and...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3560286

    authors: Wang C,Yang Y,Ding Z,Meng J,Wang K,Yang W,Xu Y

    更新日期:2011-04-01 00:00:00

  • Quantitative photoacoustic imaging: correcting for heterogeneous light fluence distributions using diffuse optical tomography.

    abstract::The specificity of molecular and functional photoacoustic (PA) images depends on the accuracy of the photoacoustic absorption spectroscopy. The PA signal is proportional to the product of the optical absorption coefficient and local light fluence; quantitative PA measurements of the optical absorption coefficient ther...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3626212

    authors: Bauer AQ,Nothdurft RE,Erpelding TN,Wang LV,Culver JP

    更新日期:2011-09-01 00:00:00

  • Imaging performance of a miniature integrated microendoscope.

    abstract::An integrated miniature multi-modal microscope (4M device) for microendoscopy was built and tested. Imaging performance is evaluated and imaging results are presented for both fluorescence and reflectance samples. Images of biological samples show successful imaging of both thin layers of fixed cells prepared on a sli...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2978060

    authors: Rogers JD,Landau S,Tkaczyk TS,Descour MR,Rahman MS,Richards-Kortum R,Kärkäinen AH,Christenson T

    更新日期:2008-09-01 00:00:00

  • Pulse-modulated second harmonic imaging microscope quantitatively demonstrates marked increase of collagen in tumor after chemotherapy.

    abstract::Pulse-modulated second harmonic imaging microscopes (PM-SHIMs) exhibit improved signal-to-noise ratio (SNR) over conventional SHIMs on sensitive imaging and quantification of weak collagen signals inside tissues. We quantify the spatial distribution of sparse collagen inside a xenograft model of human acute myeloid le...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3497565

    authors: Raja AM,Xu S,Sun W,Zhou J,Tai DC,Chen CS,Rajapakse JC,So PT,Yu H

    更新日期:2010-09-01 00:00:00

  • Integration of a Raman spectroscopy system to a robotic-assisted surgical system for real-time tissue characterization during radical prostatectomy procedures.

    abstract::Surgical excision of the whole prostate through a radical prostatectomy procedure is part of the standard of care for prostate cancer. Positive surgical margins (cancer cells having spread into surrounding nonresected tissue) occur in as many as 1 in 5 cases and strongly correlate with disease recurrence and the requi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.2.025001

    authors: Pinto M,Zorn KC,Tremblay JP,Desroches J,Dallaire F,Aubertin K,Marple E,Kent C,Leblond F,Trudel D,Lesage F

    更新日期:2019-02-01 00:00:00

  • Tool for simulating the focusing of arbitrary vector beams in free-space and stratified media.

    abstract::Vectorial models of focused beams are important to a variety of fields including microscopy, lithography, optical physics, and biomedical imaging. This has led to many models being developed, which calculate how beams of various profiles are focused both in free space and in the presence of stratified media. The major...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.9.090801

    authors: Munro PRT

    更新日期:2018-09-01 00:00:00

  • Medulla loss of scalp hair in breast cancer patients determined by near-infrared microscopy.

    abstract::Inexpensive near-infrared microscopy (NIRM) was developed as a convenient technique to detect the medulla loss of scalp hair while reducing analytical time with easy sample preparation, leading to a field screening tool for breast cancer. NIRM has been evaluated as an alternative to synchrotron-based nanoscopy and to ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.9.096501

    authors: Choi Y,Jeong YJ,Jeon JG,Park SH,Choi HR,Kim JK

    更新日期:2019-09-01 00:00:00

  • Noninvasive monitoring of hemodynamic stress using quantitative near-infrared frequency-domain photon migration spectroscopy.

    abstract::Hemorrhagic hypovolemia and inotropic agent administration were used to manipulate cardiac output (CO) and oxygen delivery in rabbits to investigate the correlation between noninvasive frequency domain photon migration (FDPM) spectroscopy and invasive hemodynamic monitoring parameters. Frequency-domain photon migratio...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1427046

    authors: Pham TH,Hornung R,Ha HP,Burney T,Serna D,Powell L,Brenner M,Tromberg BJ

    更新日期:2002-01-01 00:00:00

  • Simultaneous measurement of dispersion, spectrum, and distance with a fourier transform spectrometer.

    abstract::A Fourier transform spectrometer is used to simultaneously measure distance, dispersion and spectrum. It is shown that short coherence interferometry has the potential to measure the three-dimensional distribution of the spatial structure of a sample with a resolution determined by the coherence length of the light so...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429885

    authors: Hellmuth T,Welle M

    更新日期:1998-01-01 00:00:00

  • Spatiotemporal characteristics of cerebral blood volume changes in rat somatosensory cortex evoked by sciatic nerve stimulation and obtained by optical imaging.

    abstract::The spatiotemporal characteristics of changes in cerebral blood volume associated with neuronal activity were investigated in the hindlimb somatosensory cortex of alpha-chloralose-urethane anesthetized rats (n=10) with optical imaging at 570 nm through a thinned skull. Activation of the cortex was carried out by elect...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1609199

    authors: Li P,Luo Q,Luo W,Chen S,Cheng H,Zeng S

    更新日期:2003-10-01 00:00:00

  • System analysis of spatial frequency domain imaging for quantitative mapping of surgically resected breast tissues.

    abstract::The feasibility of spatial frequency domain imaging (SFDI) for breast surgical margin assessment was evaluated in tissue-simulating phantoms and in fully intact lumpectomy specimens at the time of surgery. Phantom data was evaluated according to contrast-detail resolution, quantitative accuracy and model-data goodness...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.3.036012

    authors: Laughney AM,Krishnaswamy V,Rice TB,Cuccia DJ,Barth RJ,Tromberg BJ,Paulsen KD,Pogue BW,Wells WA

    更新日期:2013-03-01 00:00:00

  • Swept-source optical coherence tomography powered by a 1.3-μm vertical cavity surface emitting laser enables 2.3-mm-deep brain imaging in mice in vivo.

    abstract::We report noninvasive, in vivo optical imaging deep within a mouse brain by swept-source optical coherence tomography (SS-OCT), enabled by a 1.3-μm vertical cavity surface emitting laser (VCSEL). VCSEL SS-OCT offers a constant signal sensitivity of 105 dB throughout an entire depth of 4.25 mm in air, ensuring an exten...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.10.106004

    authors: Choi WJ,Wang RK

    更新日期:2015-10-01 00:00:00

  • Applications of compressive sensing in spatial frequency domain imaging.

    abstract:SIGNIFICANCE:Spatial frequency domain imaging (SFDI) is an imaging modality that projects spatially modulated light patterns to determine optical property maps for absorption and reduced scattering of biological tissue via a pixel-by-pixel data acquisition and analysis procedure. Compressive sensing (CS) is a signal pr...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.11.112904

    authors: Mellors BOL,Bentley A,Spear AM,Howle CR,Dehghani H

    更新日期:2020-11-01 00:00:00

  • Use of laser tweezers to analyze sperm motility and mitochondrial membrane potential.

    abstract::We combine laser tweezers with custom computer tracking software and robotics to analyze the motility [swimming speed, VCL (curvilinear velocity), and swimming force in terms of escape laser power (Pesc)] and energetics [mitochondrial membrane potential (MP)] of individual sperm. Domestic dog sperm are labeled with a ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2839051

    authors: Nascimento JM,Shi LZ,Chandsawangbhuwana C,Tam J,Durrant B,Botvinick EL,Berns MW

    更新日期:2008-01-01 00:00:00

  • Analysis of the dispersion compensation of acousto-optic deflectors used for multiphoton imaging.

    abstract::The acousto-optic deflector (AOD) is highly preferred in laser scanning microscopy for its fast scanning ability and random-addressing capability. However, its application in two-photon microscopy is frustrated by the dispersion of the AOD, which results in beam distortion and pulse lengthening. We report the analysis...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2714061

    authors: Zeng S,Lv X,Bi K,Zhan C,Li D,Chen WR,Xiong W,Jacques SL,Luo Q

    更新日期:2007-03-01 00:00:00

  • Antibody-based magnetic nanoparticle immunoassay for quantification of Alzheimer's disease pathogenic factor.

    abstract::Alzheimer's disease (AD) is a neurodegenerative disorder that leads to a decline in cognitive and intellectual abilities and an irreversible mental deterioration. Based on multidisciplinary AD research, the most universally accepted hypotheses on AD pathogenesis are the intracerebral aggregate formation of beta-amyloi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.5.051205

    authors: Kim CB,Choi YY,Song WK,Song KB

    更新日期:2014-05-01 00:00:00

  • Reflectance confocal microscopy for characterization of mammary ductal structures and development of neoplasia in genetically engineered mouse models of breast cancer.

    abstract::The earliest steps of breast cancer begin with aberrations in mammary ductal structure. Techniques that enable an investigator to image in situ and then analyze the same tissue using biochemical tools facilitates identification of genetic networks and signaling pathways active in the imaged structure. Cellular confoca...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2065827

    authors: Parrish A,Halama E,Tilli MT,Freedman M,Furth PA

    更新日期:2005-09-01 00:00:00

  • Cellular resolution ex vivo imaging of gastrointestinal tissues with optical coherence microscopy.

    abstract::Optical coherence microscopy (OCM) combines confocal microscopy and optical coherence tomography (OCT) to improve imaging depth and contrast, enabling cellular imaging in human tissues. We aim to investigate OCM for ex vivo imaging of upper and lower gastrointestinal tract tissues, to establish correlations between OC...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3322704

    authors: Aguirre AD,Chen Y,Bryan B,Mashimo H,Huang Q,Connolly JL,Fujimoto JG

    更新日期:2010-01-01 00:00:00

  • Design and characterization of a handheld multimodal imaging device for the assessment of oral epithelial lesions.

    abstract::A compact handpiece combining high resolution fluorescence (HRF) imaging with optical coherence tomography (OCT) was developed to provide real-time assessment of oral lesions. This multimodal imaging device simultaneously captures coregistered en face images with subcellular detail alongside cross-sectional images of ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.8.086004

    authors: Higgins LM,Pierce MC

    更新日期:2014-08-01 00:00:00

  • Automatic detection of foreign objects in computed radiography.

    abstract::This paper presents an effective two-step scheme for automatic object detection in computed radiography (CR) images. First, various structure elements of the morphological filters, designed by incorporating available morphological features of the objects of interest including their sizes and rough shape descriptions, ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1289771

    authors: Xuan J,Adali T,Wang Y,Siegel E

    更新日期:2000-10-01 00:00:00

  • Noncontact spirometry with a webcam.

    abstract::We present an imaging-based method for noncontact spirometry. The method tracks the subtle respiratory-induced shoulder movement of a subject, builds a calibration curve, and determines the flow-volume spirometry curve and vital respiratory parameters, including forced expiratory volume in the first second, forced vit...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.5.057002

    authors: Liu C,Yang Y,Tsow F,Shao D,Tao N

    更新日期:2017-05-01 00:00:00

  • High temperature heat source generation with quasi-continuous wave semiconductor lasers at power levels of 6 W for medical use.

    abstract::We investigate a technology to create a high temperature heat source on the tip surface of the glass fiber proposed for medical surgery applications. Using 4 to 6 W power level semiconductor lasers at a wavelength of 980 nm, a laser coupled fiber tip was preprocessed to contain a certain amount of titanium oxide powde...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.10.101502

    authors: Fujimoto T,Imai Y,Tei K,Ito S,Kanazawa H,Yamaguchi S

    更新日期:2014-01-01 00:00:00

  • Interplay of tumor vascular oxygenation and tumor pO2 observed using near-infrared spectroscopy, an oxygen needle electrode, and 19F MR pO2 mapping.

    abstract::This study investigates the correlation of tumor blood oxygenation and tumor pO(2) with respect to carbogen inhalation. After having refined and validated the algorithms for calculating hemoglobin concentrations, we used near-infrared spectroscopy (NIRS) to measure changes of oxygenated hemoglobin concentration (delta...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1527049

    authors: Kim JG,Zhao D,Song Y,Constantinescu A,Mason RP,Liu H

    更新日期:2003-01-01 00:00:00

  • Multimodal optical microscope for detecting viability of mouse embryos in vitro.

    abstract::We present a multimodal optical microscope that incorporates six imaging modalities on one common platform. The imaging modalities include three staring modes, optical quadrature microscopy (OQM), differential interference contrast (DIC) microscopy, and epi-fluorescence microscopy, and three scanning modes, confocal r...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2753744

    authors: Warger WC 2nd,Laevsky GS,Townsend DJ,Rajadhyaksha M,DiMarzio CA

    更新日期:2007-07-01 00:00:00