Diagnostic usefulness of serum interleukin 6 (IL-6) and C-reactive protein (CRP) in the differentiation between pancreatic cancer and chronic pancreatitis.

Abstract:

:Previous studies have shown elevated serum levels of interleukin 6 (IL-6) and C-reactive protein (CRP) in patients with pancreatic cancer (PC). The aim of this study was to assess the diagnostic usefulness of pretreatment serum levels of IL-6 and CRP to differentiate between PC and chronic pancreatitis (CP) patients. Serum levels of CRP, IL-6, carcinoembryonic antigen (CEA), and carbohydrate antigen 19-9 (CA 19-9) were determined in 78 patients with PC before surgery, in 45 patients with CP, and in 70 healthy controls. Serum levels of all the proteins tested were significantly higher in cancer patients when compared with CP and healthy subjects, and increased in more advanced tumor stages. Concentrations of IL-6 were significantly higher in nonresectable tumors and in patients who died during the 2-year observation period. Area under receiver operating characteristic curve for IL-6 was higher than for other substances tested in the differentiation between PC and CP. Cox's univariate analysis revealed serum IL-6 as a significant prognostic factor of patients' survival. Our findings suggest higher diagnostic usefulness of serum IL-6 than CRP, CEA, and CA 19-9 in the diagnosis and prognosis of patients with PC and in the differentiation with CP.

journal_name

J Clin Lab Anal

authors

Mroczko B,Groblewska M,Gryko M,Kedra B,Szmitkowski M

doi

10.1002/jcla.20395

subject

Has Abstract

pub_date

2010-01-01 00:00:00

pages

256-61

issue

4

eissn

0887-8013

issn

1098-2825

journal_volume

24

pub_type

杂志文章
  • Useful information provided by graphic displays of automated cell counter in hematological malignancies.

    abstract:BACKGROUND:Automated cell counters have become more and more sophisticated with passing years. The numerical and graphic data both provide useful clues for suspecting a diagnosis especially when the workload is very high. AIM:We present our experience of useful information provided by graphic displays of an automated ...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.22392

    authors: Gupta M,Chauhan K,Singhvi T,Kumari M,Grover RK

    更新日期:2018-06-01 00:00:00

  • Molecular forms of soluble human T lymphocyte receptor for sheep erythrocytes in serum and saliva.

    abstract::Using a specific serum anti-soluble T lymphocytes receptor for sheep erythrocytes (E) and SDS-PAGE, we detected radioactive bands of molecular weight 58,000 in immunoprecipitates of supernatant of heated human lymphocytes (SHL), in the supernatant of PHA stimulated lymphocyte cultures (SLC), normal human serum (NHS), ...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.1860050208

    authors: Itano EN,Ono MA,Sumigawa M,Longo IM,Moura NC,Mendes NF

    更新日期:1991-01-01 00:00:00

  • Immunophenotypes and clinical features of lymphocytes in the labial gland of primary Sjogren's syndrome patients.

    abstract:OBJECTIVE:To investigate consistency of lymphocyte immunophenotype between labial gland and peripheral blood in patients with primary Sjogren's syndrome (pSS). METHODS:Seventy-one pSS patients and 35 patients with maxillofacial trauma were included in the study. Based on the ratio of CD20 to CD3 in labial gland from 7...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.22585

    authors: Sun W,Zhang N,Zhang Y,Shao Z,Gong L,Wei W

    更新日期:2018-11-01 00:00:00

  • High frequency of variant RHD genotypes among donors and patients of mixed origin with serologic weak-D phenotype.

    abstract:BACKGROUND:The current transfusion policy recommended for individuals with serologic weak-D phenotype is based on data derived from European-descent populations. Data referring to the distribution of RH alleles underlying weak-D phenotype among people of mixed origin are yet incomplete, and the applicability of Europea...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.22596

    authors: Dezan MR,Oliveira VB,Gomes ÇN,Luz F,Gallucci AJ,Bonifácio SL,Alencar CS,Sabino EC,Pereira AC,Krieger JE,Rocha V,Mendrone-Junior A,Dinardo CL

    更新日期:2018-11-01 00:00:00

  • Development and evaluation of armored RNA-based standards for quantification of BCR-ABL1p210/p190 fusion gene transcripts.

    abstract:BACKGROUND:Standards play an important role in detection of the BCR-ABL1 fusion gene (FG) transcript. However, the standards widely used in laboratories are mainly based on plasmids or cDNA, which cannot accurately reflect the process of RNA extraction and cDNA synthesis. Therefore, we aimed to develop armored RNA-base...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.22612

    authors: Fu Y,Zhang R,Wu Q,Zhang J,Bao L,Li J

    更新日期:2018-11-01 00:00:00

  • Association of Serum Albumin Level and Mortality in Premature Infants.

    abstract:BACKGROUND:Hypoalbuminemia has been proven to be a powerful predictor of mortality in adult patients. However, prognostic value of serum albumin in neonates is not clear. OBJECTIVE:To assess the relationship between serum albumin level within the first day of life and outcome in preterm infants born before 32 weeks of...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.21949

    authors: Torer B,Hanta D,Yapakci E,Gokmen Z,Parlakgumus A,Gulcan H,Tarcan A

    更新日期:2016-11-01 00:00:00

  • Accelerated stability model for predicting shelf-life.

    abstract::Second- and higher-order degradation reactions sometimes cannot be approximated with linear or exponential relationships and need to be appropriately modeled. Events above the COULTER HmX Analyzer white blood cell (WBC) counting threshold were recorded for the HmX PAK reagent system stored at five elevated temperature...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.10043

    authors: Magari RT,Murphy KP,Fernandez T

    更新日期:2002-01-01 00:00:00

  • Impaired interleukin-2 production by T-lymphocytes in polycythemia vera.

    abstract::T-lymphocyte function was investigated in a group of eight patients with polycythemia vera (PV) and 13 normals. Responsiveness of T-cells to stimulation by mitogen was significantly impaired in the PV patients (p = .02). Analysis of immune cell subpopulation composition by assessment of cell surface phenotype did not ...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.1860030204

    authors: Paul CC,Baumann MA

    更新日期:1989-01-01 00:00:00

  • Quality specification and status of internal quality control of cardiac biomarkers in China from 2011 to 2016.

    abstract:BACKGROUND:This study aimed to investigate the status of internal quality control (IQC) for cardiac biomarkers from 2011 to 2016 so that we can have overall knowledge of the precision level of measurements in China and set appropriate precision specifications. METHODS:Internal quality control data of cardiac biomarker...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.22324

    authors: Li T,Wang W,Zhao H,He F,Zhong K,Yuan S,Wang Z

    更新日期:2018-05-01 00:00:00

  • Comparative evaluation of a new chemiluminiscent assay and an ELISA for the detection of IgM against measles.

    abstract:BACKGROUND:The primary test for the laboratory confirmation of measles is immunoglobulin M (IgM) serology. It is therefore important to evaluate new commercial measles IgM immunoassays to ensure high-quality measles diagnostic testing. The purpose of this study was to evaluate the diagnostic performance of LIAISON IgM ...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.21630

    authors: Sampedro A,Rodríguez-Granger J,Gómez C,Lara A,Gutierrez J,Otero A

    更新日期:2013-11-01 00:00:00

  • Measurement of serum IgA and C3 may predict the diagnosis of patients with IgA nephropathy prior to renal biopsy.

    abstract::The levels of serum IgA and C3 in patients with IgA nephropathy were determined using international standard serum (IFCC/CRM470) in a multicenter trial in Japan. The ratio of serum IgA to C3 (serum IgA/C3 ratio) without any information from renal biopsy was used for the diagnosis of IgA nephropathy. Three hundred and ...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:

    authors: Tomino Y,Suzuki S,Imai H,Saito T,Kawamura T,Yorioka N,Harada T,Yasumoto Y,Kida H,Kobayashi Y,Endoh M,Sato H,Saito K

    更新日期:2000-01-01 00:00:00

  • Preparation and characterization of anti-anti-idiotypic monoclonal antibody ("Ab1-like Ab3") in relation to carcinoembryonic antigen.

    abstract::In order to analyze the epitope structure of carcinoembryonic antigen (CEA) and the idiotype network system, seven anti-idiotypic monoclonal antibodies (anti-Id MoAbs) were generated from a BALB/c mouse immunized with anti-CEA MoAb P1-356, which recognized a synthetic peptide P1 of CEA, domain I. These MoAbs were divi...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.10058

    authors: Tsujisaki M,Masuya J,Okada Y,Jinnohara T,Sasaki S,Yachi A,Imai K

    更新日期:2002-01-01 00:00:00

  • Detection of Human Epididymis Protein 4 (HE4) in Human Serum Samples Using a Specific Monoclonal Antibody-Based Sandwich Enzyme-Linked Immunosorbent Assay (ELISA).

    abstract:BACKGROUND:The human epididymis protein 4 (HE4) may have high specificity in the detection of malignant diseases, making the development of an immunoassay for HE4 essential. METHODS:In our study, a fusion gene was constructed encoded with the HE4 protein. This protein was then produced in the bacterial cells (Escheric...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.21906

    authors: Zhou L,Lv Z,Shao J,Xu Y,Luo X,Zhang Y,Hu Y,Zhang W,Luo S,Fang J,Wang Y,Duan C,Huang R

    更新日期:2016-09-01 00:00:00

  • HBV serum markers of 49164 patients and their relationships to HBV genotype in Fujian Province of China.

    abstract:BACKGROUND:There is a high prevalence of Hepatitis B virus (HBV) infection in China. The aim of this article is to reveal the HBV prevalence and its outcome in southern China by analyzing the HBV serum markers and their relationship to HBV genotype. METHODS:HBV serum markers, HBV-DNA and Alanine aminotransferase (ALT)...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.21573

    authors: Lin S,Liu C,Shang H,Chen H,Yang B,Chen J,Chen Y,Chen D,Ou Q

    更新日期:2013-03-01 00:00:00

  • Circular RNA LARP4 correlates with decreased Enneking stage, better histological response, and prolonged survival profiles, and it elevates chemosensitivity to cisplatin and doxorubicin via sponging microRNA-424 in osteosarcoma.

    abstract:BACKGROUND:This study aimed to evaluate the association of circular RNA La-related RNA-binding protein 4 (circ-LARP4) with clinical features and prognosis in osteosarcoma patients, and further explore its effect on chemosensitivity in osteosarcoma cells. METHODS:Seventy-two osteosarcoma patients with Enneking stage II...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.23045

    authors: Hu Y,Gu J,Shen H,Shao T,Li S,Wang W,Yu Z

    更新日期:2020-02-01 00:00:00

  • High frequency of antiphospholipid antibodies in primary biliary cirrhosis.

    abstract:AIM:To evaluate, retrospectively, the frequency of autoantibodies of antiphospholipid syndrome (APLS) in Tunisian patients with primary biliary cirrhosis (PBC). PATIENTS AND METHODS:We analyzed 80 PBC sera and 80 sera from blood donors. ELISA was used to determine the frequency of antibodies against cardiolipin (aCL I...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.21723

    authors: Mankaï A,Manoubi W,Ghozzi M,Melayah S,Sakly W,Ghedira I

    更新日期:2015-01-01 00:00:00

  • Factors interfering with the accuracy of five blood glucose meters used in Chinese hospitals.

    abstract:BACKGROUND:The prevalence of diabetes is increasing in China. Glucose control is very important in diabetic patients. The aim of this study was to compare the accuracy of five glucose meters used in Chinese hospitals with a reference method, in the absence and presence of various factors that may interfere with the met...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.21611

    authors: Lv H,Zhang GJ,Kang XX,Yuan H,Lv YW,Wang WW,Randall R

    更新日期:2013-09-01 00:00:00

  • Performance evaluation of Mindray CAL 8000(BC-6800 and SC-120) hematology analyzer and slidemaker/stainer.

    abstract:INTRODUCTION:The Mindray CAL 8000 is a cellular analysis line that consists of the BC-6800, an automated hematology analyzer, and the SC-120, an automated slidemaker/stainer. We evaluated the performances of the BC-6800 and the SC-120. METHODS:Four hundred and eight normal and abnormal samples were analyzed. The perfo...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.22065

    authors: Lee HT,Park PW,Seo YH,Kim KH,Seo JY,Jeong JH,Kim MJ,Ahn JY

    更新日期:2017-07-01 00:00:00

  • Differentiation of myeloperoxidase and glandular peroxidase in biological fluids: application to human saliva.

    abstract::A modification of the assay system for peroxidase activity in human mixed saliva using 2,2'-azinobis-(-ethylbenzthiazoline-6-sulphonic acid) (ABTS) as the substrate is reported. The modifications permit differentiation between glandular peroxidase (SPX) and myeloperoxidase (MPX) activity. In addition, factors endogeno...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.1860050111

    authors: Venezie RD,Jenzano JW,Lundblad RL

    更新日期:1991-01-01 00:00:00

  • Rapid measurement of serum pancreatic amylase.

    abstract::A simple, rapid assay for the pancreatic isoenzyme of human serum amylase was developed. The assay utilized an immunoabsorbent prepared by coating latex beads with a monoclonal antibody specific for pancreatic amylase. Treatment of patient serum with immunoabsorbent removed pancreatic amylase, and measurement of resid...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.1860080104

    authors: Landt M,Hortin GL,Smith CH,Pashos G,Vaidya HC,Rosenblum JL

    更新日期:1994-01-01 00:00:00

  • Detection of hepatitis C virus infection with recombinant immunoblot assay, synthetic immunoblot assay, and polymerase chain reaction.

    abstract::The newly developed immunoblot assay, RIBA SIA (recombinant and synthetic polypeptide immunoblot assay), Chiron, Calif., was compared with the commercially available second generation recombinant immunoblot assay (RIBA-2) for the detection of antibody to hepatitis C virus (anti-HCV). The two immunoblot tests were also...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.1860070306

    authors: Chaudhary RK,Andonov A,MacLean C

    更新日期:1993-01-01 00:00:00

  • Flow cytometric analysis of lymphocyte subpopulations in infants with congenital heart disease.

    abstract::Premortem diagnosis of the DiGeorge syndrome and its partial variants relies on the demonstration of a primary defect in cell-mediated immunity, generally in the setting of an infant with congenital heart disease, hypocalcemia, absence of a thymic shadow, and typical dysmorphic features. Although T-cell enumeration is...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.1860030105

    authors: Slade HB,Greenwood JH,Beekman RH 3rd,McCoy JP Jr,Hudson JL,Pahwa S,Schwartz SA

    更新日期:1989-01-01 00:00:00

  • New proposed guidelines for early identification of successful myeloid and erythroid engraftment in hematopoietic stem cell transplantation.

    abstract:BACKGROUND:After hematopoietic stem cell transplantation (HSCT), early detection of engraftment would be of critical value for clinicians. The aim of this study was to identify faster parameters for engraftment. METHODS:We evaluated blood cell parameters including complete blood count (CBC), differential counts, and v...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.21712

    authors: Yahng SA,Lee JW,Kim Y,Kim M,Oh EJ,Park YJ,Lee JW,Cho B,Han K

    更新日期:2014-11-01 00:00:00

  • Identical IgM antibodies recognizing a glycine-alanine epitope are induced during acute infection with Epstein-Barr virus and cytomegalovirus.

    abstract::We studied antibody production in serial serum samples from patients with acute Epstein-Barr virus (EBV) and cytomegalovirus (CMV) infections. Sera were analyzed both by enzyme-linked immunosorbent assay (ELISA) using a synthetic peptide (P62) derived from the glycine-alanine repeating region of the Epstein-Barr nucle...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.1860040613

    authors: Rhodes G,Smith RS,Rubin RE,Vaughan J,Horwitz CA

    更新日期:1990-01-01 00:00:00

  • Proteinase K inactivation of cytosolic aspartate aminotransferase isoenzyme for measurement of human serum mitochondrial aspartate aminotransferase.

    abstract::We studied a new proteinase K assay method for human serum mitochondrial aspartate aminotransferase. We found that proteinase K showed no inactivation of human mitochondrial aspartate aminotransferase isoenzyme and complete inactivation of cytosolic aspartate aminotransferase. Previous studies have shown that selectiv...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.1860070202

    authors: Watazu Y,Uji Y,Okabe H,Shirahase Y,Kaneda N,Karmen A

    更新日期:1993-01-01 00:00:00

  • Long non-coding RNAE330013P06 promotes progression of breast cancer with type 2 diabetes.

    abstract:BACKGROUND:In previous research, we found diabetes rather than obesity was an independent risk factor of breast cancer. However, why diabetes could lead to increased risk of breast cancer patients remains elusive. Long non-coding RNAE330013P06 has been shown to be upregulated in diabetes, and long non-coding RNAs gener...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.23172

    authors: Chen R,Shi P,Zhang Y,Wu H,Li X,Yang W,Luo F,JinmingXue,Yao L,Yang J,Wang W,Zhang B,Li P,Miao Y,Wang Q,Tian F

    更新日期:2020-05-01 00:00:00

  • Isolation and characterizations of clarithromycin-resistant Mycobacterium avium clinical isolates.

    abstract::Mycobacterium avium is an important intracellular pathogen, particularly in AIDS patients. It also shows the second frequency among nontuberculous mycobacteria infections in Korea. Point mutations of domain V region of the 23S rRNA gene has been known to confer clarithromycin resistance to M. avium. In order to isolat...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.20403

    authors: Lee SH,Park YK,Kim CK,Kim HJ

    更新日期:2011-01-01 00:00:00

  • Clinical application of red cell distribution width, mean platelet volume, and cancer antigen 125 detection in endometrial cancer.

    abstract:BACKGROUND:Red cell distribution width (RDW) and mean platelet volume (MPV) are considered to be associated with tumors. We investigated the diagnostic value of RDW, MPV, and cancer antigen 125 (CA125), alone or in combination, in the diagnosis of endometrial cancer and endometrial hyperplasia. METHODS:This study incl...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.23309

    authors: Zhang H,Liang K,Ke L,Tang S

    更新日期:2020-08-01 00:00:00

  • Comparison of point-of-care and central laboratory analyzers for blood gas and lactate measurements.

    abstract:BACKGROUND:Blood gas analysis and blood lactate measurement have important roles in patient management. Point-of-care (POC) testing simplifies and provides rapid blood gas and lactate measurements. This study aimed to compare pH, pCO2 , pO2 , and lactate measurements between a POC device and a benchtop blood gas analyz...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.22885

    authors: Indrasari ND,Wonohutomo JP,Sukartini N

    更新日期:2019-06-01 00:00:00

  • Adrenal diffuse large B-cell lymphoma with high PD-L1 expression: Two case reports and literature review.

    abstract:BACKGROUND:Primary adrenal lymphoma (PAL) is an infrequent malignant disease and there is no consensus classification or specialized treatment for it. However, PAL has been observed to have worse prognosis compared with other extrarenal malignant lymphomas and diffuse large B-cell lymphoma presents as the most common s...

    journal_title:Journal of clinical laboratory analysis

    pub_type:

    doi:10.1002/jcla.23173

    authors: Chen Y,He HS,Hu QF,Wang G