Circular RNA LARP4 correlates with decreased Enneking stage, better histological response, and prolonged survival profiles, and it elevates chemosensitivity to cisplatin and doxorubicin via sponging microRNA-424 in osteosarcoma.

Abstract:

BACKGROUND:This study aimed to evaluate the association of circular RNA La-related RNA-binding protein 4 (circ-LARP4) with clinical features and prognosis in osteosarcoma patients, and further explore its effect on chemosensitivity in osteosarcoma cells. METHODS:Seventy-two osteosarcoma patients with Enneking stage IIA-IIB who underwent resection were consecutively enrolled, and then, tumor tissues and non-tumor tissues were obtained. Circ-LARP4 in tumor tissue/non-tumor tissue was detected by quantitative polymerase chain reaction. After circ-LARP4 overexpression and negative control overexpression plasmid transfection, relative cell viability (%) was evaluated by Cell Counting Kit-8 in MG63 cells treated by different concentrations of cisplatin, methotrexate, and doxorubicin, and IC50 was calculated. RESULTS:Circ-LARP4 was downregulated in tumor tissue compared with non-tumor tissue and had a good value in distinguishing tumor tissue from non-tumor tissue with an area under curve of 0.829 (95% CI: 0.762-0.859). Meanwhile, tumor circ-LARP4 was negatively correlated with the Enneking stage. After resection, circ-LARP4 high expression patients showed an increased tumor cell necrosis rate to adjuvant chemotherapy compared to circ-LARP4 low expression patients, and circ-LARP4 high expression correlated with prolonged disease-free survival and overall survival. In vitro experiments revealed that circ-LARP4 overexpression elevated the chemosensitivity of MG63 cells to cisplatin and doxorubicin but not methotrexate, with decreased cisplatin IC50 and doxorubicin IC50 concentrations than negative control. Besides, miR-424 overexpression attenuated the chemosensitivity in circ-LARP4 overexpression-treated MG63 cells. CONCLUSION:Circ-LARP4 high expression correlates with decreased Enneking stage and prolonged survival profiles, and it elevates chemosensitivity to cisplatin and doxorubicin via sponging miR-424 in osteosarcoma.

journal_name

J Clin Lab Anal

authors

Hu Y,Gu J,Shen H,Shao T,Li S,Wang W,Yu Z

doi

10.1002/jcla.23045

subject

Has Abstract

pub_date

2020-02-01 00:00:00

pages

e23045

issue

2

eissn

0887-8013

issn

1098-2825

journal_volume

34

pub_type

杂志文章
  • Novel and sensitive noncompetitive enzyme immunoassay (hetero-two-site enzyme immunoassay) for alpha-human atrial natriuretic peptide in plasma.

    abstract::A novel and sensitive noncompetitive enzyme immunoassay (hetero-two-site enzyme immunoassay) for alpha-human atrial natriuretic peptide (alpha-hANP) in plasma, which uses only one monoclonal IgG for the ring structure of alpha-hANP, is described. Plasma was filtered through polysaccharide membrane to separate peptides...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.1860050506

    authors: Hashida S,Yamamoto N,Ishikawa E

    更新日期:1991-01-01 00:00:00

  • Evaluation of the analytical performance of endocrine analytes using sigma metrics.

    abstract:BACKGROUND:(a) To evaluate the clinical performance of endocrine analytes using the sigma metrics (σ) model. (b) To redesign quality control strategies for performance improvement. METHODS:The sigma values of the analytes were initially evaluated based on the allowable total error (TEa), bias, and coefficient of varia...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.23581

    authors: Liu Y,Cao Y,Liu X,Wu L,Cai W

    更新日期:2020-09-20 00:00:00

  • Evaluation of an automated urine chemistry reagent-strip analyzer.

    abstract::We evaluated the Miles Inc., Clinitek Atlas Automated Urine Chemistry Analyzer for 11 tests: bilirubin, color, glucose, ketones, leukocyte esterase, nitrite, occult blood, pH, protein, specific gravity, and urobilinogen. The instrument uses a roll of reagent strips affixed to a clear plastic support; urine specimens a...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.1860090311

    authors: Lott JA,Johnson WR,Luke KE

    更新日期:1995-01-01 00:00:00

  • The impact of IGF-I gene polymorphisms on coronary artery disease susceptibility.

    abstract:BACKGROUND:Coronary artery disease (CAD) was the second leading cause of death for the past 3 years in Taiwan. The insulin-like growth factor (IGF) system is considered a new risk factor of CAD because investigations show that the levels and bioactivity of IGF-I and IGFBP-3 (where IGFBP is insulin-like growth factor-bi...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.21581

    authors: Lin HL,Ueng KC,Wang HL,Chen TP,Yang SF,Chu SC,Hsieh YS

    更新日期:2013-03-01 00:00:00

  • After successful hepatitis C virus antiviral therapy: It looks that normal alanine aminotransferase level is not the normal.

    abstract:BACKGROUND:Normal serum alanine aminotransferase (ALT) levels differ with age, gender, and body mass index. Adjusting the upper limits of normal (ULN) for ALT needs further research in different populations. Aim of this work was to monitor the effect of successful chronic hepatitis C (CHC) treatment on the ALT levels i...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.22296

    authors: El Kassas M,Alboraie M,Mostafa A,Ezzat R,El Tahan A,Afify S,Sweedy A,Kabbash I,Esmat G

    更新日期:2018-03-01 00:00:00

  • Long noncoding RNAs antisense noncoding RNA in the INK4 locus (ANRIL) correlates with lower acute exacerbation risk, decreased inflammatory cytokines, and mild GOLD stage in patients with chronic obstructive pulmonary disease.

    abstract:BACKGROUND:We aimed to assess the predictive value of long noncoding RNAs antisense noncoding RNA in the INK4 locus (lncRNAs ANRIL) for acute exacerbation of chronic obstructive pulmonary disease (COPD) and evaluate its correlation with inflammatory cytokines as well as the Global Initiative for Chronic Obstructive Lun...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.22678

    authors: Ge J,Geng S,Jiang H

    更新日期:2019-02-01 00:00:00

  • A rapid enzyme-linked immunosorbent assay with two modes of detection for measuring cytokine concentration.

    abstract::Interleukin (IL)-6 and IL-8 were measured in 101 serum samples collected from eight intensive-care unit patients using a polystyrene-based stick enzyme-linked immunosorbent assay (STICKELISA) system. This system consisted of an immobilized-antibody ELISA stick and a noncontact spectrophotometer. Cytokine concentration...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.20287

    authors: Miwa K,Shibayama N,Moriguchi T,Goto J,Yanagisawa M,Yamazaki Y,Jung G,Matsuda K

    更新日期:2009-01-01 00:00:00

  • Enhanced RBC Aggregation in Type 2 Diabetes Patients.

    abstract:BACKGROUND:This study aimed to investigate the relationship between HbA1c and RBC aggregation in type 2 diabetes mellitus (T2DM) patients by analysis of data from routine clinical tests and from in vitro experiments. METHODS:A total of 2,111 inpatients with type 2 diabetes were selected and among them, 364 patients (G...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.21784

    authors: Li Q,Li L,Li Y

    更新日期:2015-09-01 00:00:00

  • N-terminal pro-Brain natriuretic peptide as a useful biomarker for monitoring prognosis in patients with cardiac valve replacement.

    abstract:BACKGROUND:N-terminal pro-Brain natriuretic peptide (NT-proBNP) is an important biomarker to indicate cardiac function, but its significance in cardiac surgery is still unclear. OBJECTIVE:To explore clinical significance of serum NT-proBNP and their dynamic characteristics in patients with cardiac valve replacement (C...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.20435

    authors: Cai B,Wang L,Liu J,Shi Y,Guo Y

    更新日期:2011-01-01 00:00:00

  • The utilization pattern of serum tumor markers in lung cancer patients: A population-based retrospective descriptive study.

    abstract:BACKGROUND:The trends in usage of tumor markers, including CEA, SCC, NSE, Cyfra21-1, and ProGRP, in Chinese lung cancer patients in the real-world setting are not fully investigated. METHODS:A retrospective descriptive study was conducted using the database of Qilu Hospital of Shandong University, China between Januar...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.23465

    authors: Wang H,Zhang J,Li X,Zhang C,Zheng S,Chi Y,Sheng X,Zhang Y

    更新日期:2020-11-01 00:00:00

  • Scanning for α-Hemoglobin Variants by High-Resolution Melting Analysis.

    abstract:BACKGROUND:Definitive detection of hemoglobin (Hb) variants requires DNA sequencing. High-resolution melting (HRM) analysis of polymerase chain reaction (PCR) amplicons was applied to detect and discriminate among uncommon α-Hb variants found in Thailand. METHODS:Uncommon suspected α-Hb variants observed in Hb typing ...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.21914

    authors: Yimniam W,Jindadamrongwech S

    更新日期:2016-09-01 00:00:00

  • Correlation of sex-determining region Y-box 30 with tumor characteristics and its prognostic value in breast cancer.

    abstract:OBJECTIVE:Sex-determining region Y-box 30 (SOX30) suppresses progression of several cancers, whereas its role in breast cancer is unclear. Therefore, we aimed to determine the correlation of SOX30 with tumor characteristics and prognosis in breast cancer patients. METHODS:The tumor samples of 510 breast cancer patient...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.23232

    authors: Peng H,Luo Y,Wu J,Yin W

    更新日期:2020-06-01 00:00:00

  • Problems in determining levels of free digoxin in patients treated with digoxin immune FAb.

    abstract::Determination of free digoxin levels in patients treated with digoxin immune FAb has long been a problematic area in clinical laboratory testing. The older radioimmunoassays resulted in inaccurate and variable results due to the competition of the administered drug with the radioactively labelled forms. The 1995 Physi...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.1860090612

    authors: Honda SA,Rios CN,Murakami L,Morita T,Scottolini AG,Bhagavan NV

    更新日期:1995-01-01 00:00:00

  • A novel frameshift mutation of COL4A5 in a Chinese family with presumed IgA nephropathy and chronic glomerulonephritis.

    abstract:BACKGROUND:Alport syndrome (ATS) is a hereditary nephritis with hereditary and clinical heterogeneity; the early clinical symptoms are atypical, which can easily lead to misdiagnosis. The proband, a 6-year-old girl, was found to have microscopic hematuria, proteinuria, and visual impairment at about 5 years old; the re...

    journal_title:Journal of clinical laboratory analysis

    pub_type:

    doi:10.1002/jcla.23558

    authors: Zhu Q,Zhou C,Wang J

    更新日期:2020-09-06 00:00:00

  • HBV serum markers of 49164 patients and their relationships to HBV genotype in Fujian Province of China.

    abstract:BACKGROUND:There is a high prevalence of Hepatitis B virus (HBV) infection in China. The aim of this article is to reveal the HBV prevalence and its outcome in southern China by analyzing the HBV serum markers and their relationship to HBV genotype. METHODS:HBV serum markers, HBV-DNA and Alanine aminotransferase (ALT)...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.21573

    authors: Lin S,Liu C,Shang H,Chen H,Yang B,Chen J,Chen Y,Chen D,Ou Q

    更新日期:2013-03-01 00:00:00

  • A comparative analysis of the efficacy of anterior cruciate ligament reconstruction with autologous ligament grafting at different time points.

    abstract:BACKGROUND:This study was performed to compare the clinical efficacies of anterior cruciate ligament (ACL) reconstruction with autologous ligament grafting at different time points. METHODS:Eighty-five patients with ACL were categorized into two groups: Group A (GA, n = 45), who underwent early-stage (≤3 weeks) surger...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.23543

    authors: Hu B,Gao F,Li C,Zhang B,An M,Lu M,Liu Y,Liu Y

    更新日期:2020-08-26 00:00:00

  • Specificity of autoantibodies to SS-A/Ro on a transfected and overexpressed human 60 kDa Ro autoantigen substrate.

    abstract::The objective of this study was to analyze apparently discrepant results that arose during the use of an indirect immunofluorescence (IIF) assay using transfected HEp-2 cells to detect anti-SS-A/Ro autoantibodies in human sera. Fourteen sera that had SS-A/Ro antibodies as detected on this commercial substrate, but did...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.10026

    authors: Fritzler MJ,Hanson C,Miller J,Eystathioy T

    更新日期:2002-01-01 00:00:00

  • Evaluation of a bench-top nephelometric immunoassay analyzer.

    abstract::We evaluated the Technicon DPA-1 immunoassay analyzer on its analytical characteristics. Therefore we studied three assays: albumin in cerebrospinal fluid and IgG and transferrin in serum. When tested with the Cusum test for linearity albumin, IgG, and transferrin measurements showed no deviation from linearity. Close...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.1860050103

    authors: van Rijn JL,van Landeghem AA,Goldschmidt HM

    更新日期:1991-01-01 00:00:00

  • Microparticle-enhanced nephelometric immunoassay of lactoferrin in human milk.

    abstract::A microparticle-enhanced nephelometric immunoassay was developed for lactoferrin quantitation in human milk. It is based on the nephelometric measurement of the light scattered during the competitive immuno-agglutination of a microparticle-lactoferrin conjugate with an antilactoferrin antiserum. This immunoassay is se...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:

    authors: Cuillière ML,Montagne P,Molé C,Béné MC,Faure G

    更新日期:1997-01-01 00:00:00

  • Serological chemiluminescence immunoassay for the diagnosis of SARS-CoV-2 infection.

    abstract:OBJECTIVE:Dynamic monitoring of the concentration variation of IgM and IgG in patients with SARS-CoV-2 infections and exploring their diagnostic value for coronavirus disease-19 (COVID-19). METHODS:A total of 15 patients with SARS-CoV-2 infection were enrolled as the COVID-19 group, and 50 patients were enrolled as th...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.23466

    authors: Lijia S,Lihong S,Huabin W,Xiaoping X,Xiaodong L,Yixuan Z,Pin H,Yina X,Xiaoyun S,Junqi W

    更新日期:2020-10-01 00:00:00

  • Comparative evaluation of a new chemiluminiscent assay and an ELISA for the detection of IgM against measles.

    abstract:BACKGROUND:The primary test for the laboratory confirmation of measles is immunoglobulin M (IgM) serology. It is therefore important to evaluate new commercial measles IgM immunoassays to ensure high-quality measles diagnostic testing. The purpose of this study was to evaluate the diagnostic performance of LIAISON IgM ...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.21630

    authors: Sampedro A,Rodríguez-Granger J,Gómez C,Lara A,Gutierrez J,Otero A

    更新日期:2013-11-01 00:00:00

  • Immune complex transfer enzyme immunoassay for antibody IgG to HIV-1 gp41 antigen using synthetic peptides as antigens.

    abstract::The immune complex transfer enzyme immunoassay for antibody IgG to HIV-1 gp41 antigen was developed using two synthetic peptides. An aliquot (10 microl) of serum samples from HIV-1 seropositive subjects was incubated simultaneously with 2,4-dinitrophenyl-bovine serum albumin-synthetic HIV-1 gp41 peptide conjugates and...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:

    authors: Hashida S,Ishikawa S,Hashinaka K,Nishikata I,Oka S,Ishikawa E

    更新日期:1998-01-01 00:00:00

  • Enzymatic assay for conjugated bilirubin (Bc) in serum using bilirubin oxidase (BOD).

    abstract::We described an automated enzymatic assay for conjugated bilirubin (Bc) in serum using the Iatro D-Bil kit, with bilirubin oxidase (EC 1.3.3.5 BOD) from Myrothecium species. The specificity of the enzyme in the Iatro D-Bil kit was examined by analyzing unconjugated bilirubin (Bu), delta bilirubin (Bdelta), and Bc with...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/(sici)1098-2825(1999)13:5<219::aid-jcla5>3

    authors: Kimura S,Iyama S,Yamaguchi Y,Hayashi S,Yanagihara T

    更新日期:1999-01-01 00:00:00

  • Modified salting-out method for DNA isolation from newborn cord blood nucleated cells.

    abstract::The present work describes modification of a widely used salting-out procedure to rapidly extract DNA suitable for PCR, using the ARMS method to amplify a target sequence in the beta-globin gene. The salting-out DNA extraction procedure did not completely remove or decrease the presence of inhibitors to PCR in a consi...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:

    authors: Noguera NI,Tallano CE,Bragós IM,Milani AC

    更新日期:2000-01-01 00:00:00

  • Automated Cerebrospinal Fluid Cell Counts Using the New Body Fluid Mode of Sysmex UF-1000i.

    abstract:BACKGROUND:We evaluated the new body fluid module on Sysmex UF1000-i (UF1000i-BF) for analysis of white blood cell (WBC) and red blood cell (RBC) in cerebrospinal fluid (CSF). METHODS:WBC and RBC counting were compared between UF1000i-BF and Fuchs-Rosenthal counting chamber in 67 CSF samples. This study also included ...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.21866

    authors: Buoro S,Apassiti Esposito S,Alessio M,Crippa A,Ottomano C,Lippi G

    更新日期:2016-09-01 00:00:00

  • Assessment of urinary total testosterone production by a highly sensitive time-resolved fluorescence immunoassay.

    abstract::Radioimmunoassay (RIA) that involves purification of the analyte by organic solvent extraction is widely used. Although the extraction RIA is reliable when properly validated, it is time consuming and radioactive, we measure urinary total testosterone with a highly sensitive rapid and accurate time-resolved fluorescen...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.20283

    authors: Bao S,Peng Y,Sheng S,Lin Q

    更新日期:2008-01-01 00:00:00

  • Exogenous interferences with Jaffe creatinine assays: addition of sodium dodecyl sulfate to reagent eliminates bilirubin and total protein interference with Jaffe methods.

    abstract:BACKGROUND:The study evaluated the impact of interferences on the analytical specificity of three commercial and commonly used creatinine methods (two Jaffe and one enzymatic). METHODS:Manufacturer creatinine methods plus modified methods were tested with the following interferences: spiking serum with bilirubin, albu...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.20350

    authors: Srisawasdi P,Chaichanajarernkul U,Teerakanjana N,Vanavanan S,Kroll MH

    更新日期:2010-01-01 00:00:00

  • The clinical significance of DJ-1 and HE4 in patients with endometrial cancer.

    abstract:BACKGROUND:The non-invasive diagnostic approach for early detection of endometrial cancer (EC) remains limited. To date, human epididymis protein 4 (HE4) has been intensively studied but its diagnostic is controversial in EC. DJ-1 is an oncoprotein secreted by cancer cells, recently identified as a potential diagnostic...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.22223

    authors: Benati M,Montagnana M,Danese E,Paviati E,Giudici S,Ruzzenente O,Franchi M,Lippi G

    更新日期:2018-01-01 00:00:00

  • Co-sensitization and cross-reactivity of Blomia tropicalis with two Dermatophagoides species in Guangzhou, China.

    abstract:BACKGROUND:Contradictory results have been reported previously in the analyses of cross-reactivity among Blomia tropicalis (Blo t), Dermatophagoides pteronyssinus (Der p), and Dermatophagoides farinae (Der f). This study aims to investigate the characteristics of co-sensitization and the IgE cross-reactivity among them...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.22981

    authors: Liu X,Zheng P,Zheng SG,Zhai Y,Zhao X,Chen Y,Cai C,Wu Z,Huang Z,Zou X,Liao C,Sun B

    更新日期:2019-11-01 00:00:00

  • An immunoenzymometric assay for a CA125-like antigen, CA602.

    abstract::An immunoenzymometric assay (IEMA) for a new CA125-like antigen, CA602, was developed. Five monoclonal antibodies raised against a human ovarian carcinoma cell line could detect their respective antigens in the sera of ovarian carcinoma patients. The antigen levels detected in serum by the various antibodies correlate...

    journal_title:Journal of clinical laboratory analysis

    pub_type: 杂志文章

    doi:10.1002/jcla.1860060204

    authors: Mochizuki H,Sato I,Nagoya K,Furusako S,Yamauchi T,Masuko H,Sato H,Morishita H,Yajima M,Sasaki H

    更新日期:1992-01-01 00:00:00