Detection of left ventricle systolic dysfunction from shape deformity.

Abstract:

:Coronary artery disease producing ischemic cardiomyopathy is the most frequent cause of left ventricular systolic dysfunction. Non-ischemic cardiomyopathies can also produce systolic dysfunction; they may be inherited as genetic disorders or occur sporadically. These coronary injuries have repercussions on the left ventricle producing changes on wall contractility, the shape of the cavity and also changes on ventricular function. This study is focused on the 2D echocardiograms of the left ventricle. Apical two chamber and four chamber view recordings were performed on normal and systolic dysfunction subjects. Individual frames were extracted for at least five cardiac cycles. After pre-processing these images, segmentation of the left ventricle was performed by Fuzzy systems. Then the volumes were measured by single and biplane methods along with the perimeter, short axis length and long axis length in each frame, from which the two indices Sphericity Index (SI) and Normalized Eccentricity Index (NEI) was determined. It was found that the diastolic phase is short in the case of systolic dysfunction, and its volume variation is not uniform as in the normal case. Also, in the case of systolic dysfunction, the span of either the long or short axis length variation is less than 0.5 cm. This depicts that akinesis is in the corresponding direction; the value of SI is less than 2 for systolic dysfunction. A sharp peak is seen at each systole point in the NEI plot and also its variation is smooth in subjects having LVEF > 45%, which is not the case for dysfunction.

authors

Manivannan J,Reddy MR,Thanikachalam S,Kumar RA

doi

10.1007/BF03178864

subject

Has Abstract

pub_date

2005-03-01 00:00:00

pages

51-5

issue

1

eissn

0158-9938

issn

1879-5447

journal_volume

28

pub_type

杂志文章
  • Ultrasound shear wave simulation of wave propagation at oblique angles.

    abstract::Shear wave elasticity imaging (SWEI) has been used to measure the local tissue elasticity. The local tissue shear modulus can be reconstructed from the displacement field of shear waves using an algebraic Helmholtz inversion (AHI) equation or a time-of-flight (TOF)-based algorithm. The shear waves, which are generated...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-019-00748-3

    authors: Park DW,Cho HC

    更新日期:2019-09-01 00:00:00

  • Comparison of natural and synthetic diamond X-ray detectors.

    abstract::Diamond detectors are particularly well suited for dosimetry applications in radiotherapy for reasons including near-tissue equivalence and high-spatial resolution resulting from small sensitive volumes. However, these detectors have not become commonplace due to high cost and poor availability arising from the need f...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-010-0040-6

    authors: Lansley SP,Betzel GT,Metcalfe P,Reinisch L,Meyer J

    更新日期:2010-12-01 00:00:00

  • Determination of correct AEC function with computed radiography cassettes.

    abstract::It has long been recognized that the assessment of Automatic Exposure Control (AEC) function is an important criterion in the assessment of any general radiographic x-ray installation. Of the tests commonly performed on an AEC, only Beam Quality Dependence relates intimately with the optical density produced on the re...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Wilkinson LE,Heggie JC

    更新日期:1997-09-01 00:00:00

  • Glaucoma detection using novel optic disc localization, hybrid feature set and classification techniques.

    abstract::Glaucoma is a chronic and irreversible neuro-degenerative disease in which the neuro-retinal nerve that connects the eye to the brain (optic nerve) is progressively damaged and patients suffer from vision loss and blindness. The timely detection and treatment of glaucoma is very crucial to save patient's vision. Compu...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0377-y

    authors: Akram MU,Tariq A,Khalid S,Javed MY,Abbas S,Yasin UU

    更新日期:2015-12-01 00:00:00

  • A novel ultrasound based approach for lesion segmentation and its applications in gynecological laparoscopic surgery.

    abstract::Laparoscopic ultrasound (LUS) has been widely utilized as a surgical aide in general, urological, and gynecological applications. Our study summarizes the clinical applications of laparoscopic ultrasonography in laparoscopic gynecologic surgery. Retrospective analyses were performed on 42 women subjects using laparosc...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0363-4

    authors: Gong XH,Lu J,Liu J,Deng YY,Liu WZ,Huang X,Pirbhulal S,Yu ZY,Wu WQ

    更新日期:2015-12-01 00:00:00

  • The appearance and effects of metallic implants in CT images.

    abstract::The computed tomography (CT) imaging artefacts that metallic medical implants produce in surrounding tissues are usually contoured and over-ridden during radiotherapy treatment planning. In cases where radiotherapy treatment beams unavoidably pass though implants, it is especially important to understand the imaging a...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-013-0197-x

    authors: Kairn T,Crowe SB,Fogg P,Trapp JV

    更新日期:2013-06-01 00:00:00

  • The calibration of plane parallel ionisation chambers for the measurement of absorbed dose in electron beams of low to medium energies. Part 1: the NACP chamber.

    abstract::A study was made of calibrating the NACP plane parallel chamber in electron beams from linear accelerators of a different manufacture with energies, Ep,o' from 4.4 to 19.1 MeV, and also in 4 and 6 MV photon beams as well as a cobalt60 beam. The photon beam measurements were both IN-AIR and IN-PHANTOM. With the excepti...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Cross P,Freeman N

    更新日期:1996-09-01 00:00:00

  • Dose computations for three-dimensional radiation treatment planning.

    abstract::The knowledge of radiation dose at all points of interest within a patient's body is essential for the evaluation of treatment plans and for the judicious selection of the best one from among a set of competing plans. This paper discusses the physical and geometric aspects of radiation dose distribution calculations n...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Mohan R

    更新日期:1989-12-01 00:00:00

  • The impact of inhomogeneous tissue anisotropy on potential distribution within head model.

    abstract::This paper investigates the influence of inhomogeneous head tissue conductivity on EEGs. A head model with inhomogeneity of radial and tangential conductivity is built up. Based on this model the EEG signals are calculated using the finite elements method. The results show that the inhomogeneous radial and tangential ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178780

    authors: Wen P

    更新日期:2003-09-01 00:00:00

  • Potential radiotherapy improvements with respiratory gating.

    abstract::Gating is a relatively new and potentially useful therapeutic addition to external beam radiotherapy applied to regions affected by intra-fraction motion. The impact was of gating on treatment margins, image artifacts, and volume and positional accuracy was investigated by CT imaging of sinusoidally moving spheres. Th...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178368

    authors: Keall PJ,Kini VR,Vedam SS,Mohan R

    更新日期:2002-03-01 00:00:00

  • ACPSEM ROSG TBI working group recommendations for quality assurance in total body irradiation.

    abstract::The Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) radiation oncology specialty group (ROSG) formed a series of working groups in 2011 to develop recommendations for guidance of radiation oncology medical physics practice within the Australasian setting. These recommendations are intend...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,实务指引

    doi:10.1007/s13246-015-0344-7

    authors: Nelligan R,Bailey M,Tran T,Baldwin Z,ACPSEM total body irradiation working group.

    更新日期:2015-06-01 00:00:00

  • Thermoluminescence dosimetry and its applications in medicine--Part 1: Physics, materials and equipment.

    abstract::Thermoluminescence dosimetry (TLD) is a versatile tool for the assessment of dose from ionising radiation. The wide variety of TLD materials and their different physical forms allow the determination of different radiation qualities at dose levels from microGy to kGy. Major advantages of TL dosimeters are their small ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,评审

    doi:

    authors: Kron T

    更新日期:1994-12-01 00:00:00

  • A phantom for verification of dwell position and time of a high dose rate brachytherapy source.

    abstract::Accuracy of dwell position and reproducibility of dwell time are critical in high dose rate (HDR) brachytherapy. A phantom was designed to verify dwell position and dwell time reproducibility for an Ir-192 HDR stepping source using Computed Radiography (CR). The central part of the phantom, incorporating thin alternat...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-012-0138-0

    authors: Madebo M,Pillainayagam J,Kron T,Franich R

    更新日期:2012-09-01 00:00:00

  • Hidden pattern discovery on epileptic EEG with 1-D local binary patterns and epileptic seizures detection by grey relational analysis.

    abstract::This paper proposes a novel approach to detect epilepsy seizures by using Electroencephalography (EEG), which is one of the most common methods for the diagnosis of epilepsy, based on 1-Dimension Local Binary Pattern (1D-LBP) and grey relational analysis (GRA) methods. The main aim of this paper is to evaluate and val...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0362-5

    authors: Kaya Y

    更新日期:2015-09-01 00:00:00

  • Characterization of a Fricke dosimeter at high energy photon and electron beams used in radiotherapy.

    abstract::The dosimetric features of the Fricke dosimeter in clinical linear accelerator beams are considered. Experimental data were obtained using various nominal energies 6 and 18 MV, 12 and 15 MeV, including the (60)Co γ-ray beam. The calibration of the dosimeters was performed using the ionization chamber as a reference do...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-011-0093-1

    authors: Moussous O,Khoudri S,Benguerba M

    更新日期:2011-12-01 00:00:00

  • Effect of postural changes on normal and stenosed common carotid artery using FSI.

    abstract::Gravity associated with postural changes has a strong bearing on haemodynamics of blood flow in arteries. Its effect on stenosed cases has not been widely investigated. In the present study, variation observed in blood flow during postural changes is investigated for different conditions like standing, sleeping and he...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-014-0246-0

    authors: Raghuvir Pai B,Ayachit A,Abdul Khader SM,Ahmed KA,Rao VR,Kamath SG,Gupta PD

    更新日期:2014-03-01 00:00:00

  • Investigating the impact of tumour motion on TomoTherapy stereotactic ablative body radiotherapy (SABR) deliveries on 3-dimensional and 4-dimensional computed tomography.

    abstract::TomoTherapy can provide highly accurate SABR deliveries, but currently it does not have any effective motion management techniques. Shallow breathing has been identified as one possible motion management solution on TomoTherapy, which has been made possible with the BreatheWell audiovisual biofeedback (AVB) device. Si...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-019-00727-8

    authors: Hu Y,Archibald-Heeren B,Byrne M,Cai E,Wang Y

    更新日期:2019-03-01 00:00:00

  • Evaluation of Bremsstrahlung radiation dose in stereotactically radiocolloid therapy of cystic craniopharyngioma tumors with 32P radio-colloid.

    abstract::Over 90% of craniopharyngeal brain tumors are cystic, which enables the injection of beta emitters such as phosphorus-32 (32P) radio-colloid into cysts for their treatment. The aim of this study was to evaluate the clinical and theoretical modelling of Bremsstrahlung radiation dose resulting from stereotactic radio-co...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-018-0665-4

    authors: Babaei M,Ghahramani-Asl R,Sadoughi HR,Sardari D,Shahzadi S

    更新日期:2018-09-01 00:00:00

  • NEMA NU 2-2001 performance testing of a Philips Gemini GXL PET/CT scanner.

    abstract::Post installation acceptance testing is vital to demonstrate that the equipment meets the vendor's specification and is suitable for clinical studies. The test procedures described in the NEMA NU 2-2001 document form the basis of vendor performance specifications of PET scanners and hence are also appropriate for acce...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-010-0016-6

    authors: Sathiakumar C,Som S,Eberl S,Lin P

    更新日期:2010-06-01 00:00:00

  • Diagnostic x-ray spectra simulation, verification and application to the clinical environment.

    abstract::A set of computer programs to simulate diagnostic x-ray spectra has been developed according to the method of Birch and Marshall, with good agreement to published HPA data. These programs have been extended to simulate spectra generated with capacitor discharge x-ray units. The application of these programs has proved...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: McLean D

    更新日期:1989-09-01 00:00:00

  • The effects of air cavities on X-ray dose distribution at 6 and 25 MV.

    abstract::Three different air channels were constructed in solid water. These resemble upper respiratory and larynx geometry. Central-axis depth-dose distributions were measured on and beyond the distal surface of the air cavities. The measurements were made with a parallel-plate Markus ionisation chamber and TLDs for 6 and 25 ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Wong TP,Kan WK,Law M

    更新日期:1996-12-01 00:00:00

  • Comparison of skin dose between conventional radiotherapy and IMRT.

    abstract::The purpose of this study was to measure skin dose using radiochromic film for two step-and-shoot IMRT fields and compare the results to the skin dose for a conventional open field. All exposures were made using a 6 MV photon beam produced by a Varian 21EX linear accelerator (Varian Medical Systems, CA, USA) equipped ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178577

    authors: Price S,Williams M,Butson M,Metcalfe P

    更新日期:2006-09-01 00:00:00

  • An investigation into lung correction for tangential breast irradiation.

    abstract::A solid water breast phantom with a lung equivalent material was constructed to investigate interface effects of 6 MV tangential photon fields. The phantom was built so that Thermo-luminescence Dosimeters (TLD) could be used for comparison to a pencil beam and Equivalent Tissue-Air-Ratio (ETAR) algorithms. The investi...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Hill B,Brown R

    更新日期:1998-03-01 00:00:00

  • Medical physics in 2020: will we still be relevant?

    abstract::From the time when Roentgen and other physicists made the discoveries which led to the development of radiology, radiotherapy and nuclear medicine, medical physicists have played a pivotal role in the development of new technologies that have revolutionized the way medicine is practiced today. Medical physicists have ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type:

    doi:10.1007/BF03178583

    authors: Ng KH

    更新日期:2008-06-01 00:00:00

  • Stereotactic dose perturbation from an aneurysm clip measured by Gafchromic EBT film.

    abstract::Aneurysm clips within stereotactic treatment volumes enhance spatial accuracy but perturb the dose distribution. The dose perturbations caused by a standard titanium alloy aneurysm clip (Ti6Al4V) have been measured with Gafchromic EBT film. The maximum dose perturbation was an increase of 6 % within 0.5 mm of the beam...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178449

    authors: He CF,Geso M,Ackerly T,Wong CJ

    更新日期:2008-03-01 00:00:00

  • Monte Carlo simulation of the RBE of I-131 radiation using DNA damage as biomarker.

    abstract::In general, a weighting factor of one is applied for low linear energy transfer radiations. However, several studies indicate that relative biological effectiveness (RBE) of low energy photons and electrons is greater than one. The aim of this current study was calculating the RBE of I-131 radiation relative to Co-60 ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-017-0544-4

    authors: Ezzati AO,Mahmoud-Pashazadeh A,Studenski MT

    更新日期:2017-06-01 00:00:00

  • Physiologic outcome of varying speed rotary blood pump support algorithms: a review study.

    abstract::Rotary blood pumps have the potential to become a viable long-term treatment option for the heart failure patients to bridge to transplantation or destination therapy. However, these devices operate at a constant speed which may lead to long term complications or they may operate in an undesired support mode such as e...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,评审

    doi:10.1007/s13246-015-0405-y

    authors: Bozkurt S

    更新日期:2016-03-01 00:00:00

  • Evaluation of effective energy for QA and QC: measurement of half-value layer using radiochromic film density.

    abstract::The effective energy of diagnostic X-rays is important for quality assurance (QA) and quality control (QC). However, the half-value layer (HVL), which is necessary to evaluate the effective energy, is not ubiquitously monitored because ionization-chamber dosimetry is time-consuming and complicated. To verify the appli...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178625

    authors: Gotanda T,Katsuda T,Gotanda R,Tabuchi A,Yamamoto K,Kuwano T,Yatake H,Takeda Y

    更新日期:2009-03-01 00:00:00

  • The use of round ended needles for high dose rate brachytherapy implants.

    abstract::The use of Speiser needles for interstitial implants has resulted in malfunctioning of HDR afterloading equipment due to seepage of blood. We have successfully used rounded ended needles in the patient after removal of the trocar ended needles, preventing the seepage of blood. This technique also helps to prevent any ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Das KR,Duchesne G,Coles JR,Pinder P

    更新日期:1999-12-01 00:00:00

  • The impact of smart metal artefact reduction algorithm for use in radiotherapy treatment planning.

    abstract::The presence of metal artefacts in computed tomography (CT) create issues in radiation oncology. The loss of anatomical information and incorrect Hounsfield unit (HU) values produce inaccuracies in dose calculations, providing suboptimal patient treatment. Metal artefact reduction (MAR) algorithms were developed to co...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-017-0543-5

    authors: Guilfoile C,Rampant P,House M

    更新日期:2017-06-01 00:00:00