The impact of smart metal artefact reduction algorithm for use in radiotherapy treatment planning.

Abstract:

:The presence of metal artefacts in computed tomography (CT) create issues in radiation oncology. The loss of anatomical information and incorrect Hounsfield unit (HU) values produce inaccuracies in dose calculations, providing suboptimal patient treatment. Metal artefact reduction (MAR) algorithms were developed to combat these problems. This study provides a qualitative and quantitative analysis of the "Smart MAR" software (General Electric Healthcare, Chicago, IL, USA), determining its usefulness in a clinical setting. A detailed analysis was conducted using both patient and phantom data, noting any improvements in HU values and dosimetry with the GE-MAR enabled. This study indicates qualitative improvements in severity of the streak artefacts produced by metals, allowing for easier patient contouring. Furthermore, the GE-MAR managed to recover previously lost anatomical information. Additionally, phantom data showed an improvement in HU value with GE-MAR correction, producing more accurate point dose calculations in the treatment planning system. Overall, the GE-MAR is a useful tool and is suitable for clinical environments.

authors

Guilfoile C,Rampant P,House M

doi

10.1007/s13246-017-0543-5

subject

Has Abstract

pub_date

2017-06-01 00:00:00

pages

385-394

issue

2

eissn

0158-9938

issn

1879-5447

pii

10.1007/s13246-017-0543-5

journal_volume

40

pub_type

杂志文章
  • Extended Kalman smoother with differential evolution technique for denoising of ECG signal.

    abstract::Electrocardiogram (ECG) signal gives a lot of information on the physiology of heart. In reality, noise from various sources interfere with the ECG signal. To get the correct information on physiology of the heart, noise cancellation of the ECG signal is required. In this paper, the effectiveness of extended Kalman sm...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-016-0468-4

    authors: Panigrahy D,Sahu PK

    更新日期:2016-09-01 00:00:00

  • Measurement of dose to the contralateral breast during radiation therapy for breast cancer: reduction by the use of superflab.

    abstract::The effect of radiation in regard to breast carcinogenesis is well studied and analysed from data from atomic bomb survivors, patients treated for acute mastitis and tuberculosis patients monitored by fluoroscopy. Therefore the radiation received by the untreated breast during breast irradiation of the other breast, i...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178353

    authors: Jamal N,Das KR

    更新日期:2001-06-01 00:00:00

  • A simulation study comparing nine mathematical models of arterial input function for dynamic contrast enhanced MRI to the Parker model.

    abstract::Due to large inter- and intra-patient variabilities of arterial input functions (AIFs), accurately modeling and using patient-specific AIF are very important for quantitative analysis of dynamic contrast enhanced MRI. Computer simulations were performed to evaluate and compare nine population AIF models with the Parke...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-018-0632-0

    authors: He D,Xu L,Qian W,Clarke J,Fan X

    更新日期:2018-06-01 00:00:00

  • Stereotactic dose perturbation from an aneurysm clip measured by Gafchromic EBT film.

    abstract::Aneurysm clips within stereotactic treatment volumes enhance spatial accuracy but perturb the dose distribution. The dose perturbations caused by a standard titanium alloy aneurysm clip (Ti6Al4V) have been measured with Gafchromic EBT film. The maximum dose perturbation was an increase of 6 % within 0.5 mm of the beam...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178449

    authors: He CF,Geso M,Ackerly T,Wong CJ

    更新日期:2008-03-01 00:00:00

  • A proton therapy system in Nagoya Proton Therapy Center.

    abstract::The purpose of this paper is to describe an outline of a proton therapy system in Nagoya Proton Therapy Center (NPTC). The NPTC has a synchrotron with a linac injector and three treatment rooms: two rooms are equipped with a gantry and the other one is equipped with a fixed horizontal beamline. One gantry treatment ro...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-016-0456-8

    authors: Toshito T,Omachi C,Kibe Y,Sugai H,Hayashi K,Shibata H,Yasui K,Tanaka K,Yamamoto T,Yoshida A,Nikawa E,Asai K,Shimomura A,Okumura I,Suzuki T,Kinou H,Isoyama S,Ogino H,Iwata H,Shibamoto Y,Mizoe J

    更新日期:2016-09-01 00:00:00

  • Image quality improvement for medium and large field of view Elekta XVI scans.

    abstract::Cone-beam computed tomography (CBCT) has become the standard imaging technique for many sites treated with Radiotherapy. The Elekta X-ray Volumetric Imaging (XVI) system allows for the acquisition of CBCTs with three different diameters; small (27 cm), medium (41 cm) and large (50 cm) (Elekta in XVI Corrective Mainten...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-019-00817-7

    authors: Little DP

    更新日期:2019-12-01 00:00:00

  • Reliability of the Cobb angle index derived by traditional and computer assisted methods.

    abstract::The reliability of the traditional Cobb angle index, which at present exhibits a wide range of reported values, was determined in this study and amounted to a within subject error of +/-4.3 degrees and a between subject error of +/-4.9 degrees. An attempt to pinpoint the source of this variability by investigating the...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Dutton KE,Jones TJ,Slinger BS,Scull ER,O'Connor J

    更新日期:1989-03-01 00:00:00

  • Expected and observed changes to descriptors of trabecular architecture with aging--a comparison of measurement techniques.

    abstract::The fragility of trabecular bone depends not only on the amount of bone but also on its architecture. In order to assess fragility of bone, describe changes due to age, and monitor effect of disease or treatment, it is necessary to model the physical properties of trabecular bone architecture. An important feature of ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Badiei A,Bottema MJ,Fazzalari NL

    更新日期:2006-03-01 00:00:00

  • Evaluation of automated image registration algorithm for image-guided radiotherapy (IGRT).

    abstract::The performance of an image registration (IR) software was evaluated for automatically detecting known errors simulated through the movement of ExactCouch using an onboard imager. Twenty-seven set-up errors (11 translations, 10 rotations, 6 translation and rotation) were simulated by introducing offset up to ± 15 mm i...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-012-0158-9

    authors: Sharma SD,Dongre P,Mhatre V,Heigrujam M

    更新日期:2012-09-01 00:00:00

  • Evaluation of effective energy for QA and QC: measurement of half-value layer using radiochromic film density.

    abstract::The effective energy of diagnostic X-rays is important for quality assurance (QA) and quality control (QC). However, the half-value layer (HVL), which is necessary to evaluate the effective energy, is not ubiquitously monitored because ionization-chamber dosimetry is time-consuming and complicated. To verify the appli...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178625

    authors: Gotanda T,Katsuda T,Gotanda R,Tabuchi A,Yamamoto K,Kuwano T,Yatake H,Takeda Y

    更新日期:2009-03-01 00:00:00

  • Human brain wave activity during exposure to radiofrequency field emissions from mobile phones.

    abstract::The aim of this study was to determine whether there is an effect of mobile phone electromagnetic field emissions on the human electroencephalograph (EEG). EEG recordings from ten awake subjects were taken during exposure to radiofrequency (RF) emissions from a mobile phone positioned behind the head. Two experimental...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1007/BF03179176

    authors: D'Costa H,Trueman G,Tang L,Abdel-rahman U,Abdel-rahman W,Ong K,Cosic I

    更新日期:2003-12-01 00:00:00

  • Using EGS4 Monte Carlo in medical radiation physics.

    abstract::Monte Carlo modelling of particle transport problems in medical radiation physics offers significant advantages over other techniques. Experiments can be performed without having to set up the physical situation, and "impossible" experiments can be performed, such as labelling multiple-scattered particles or simulatin...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type:

    doi:

    authors: Murray D

    更新日期:1990-09-01 00:00:00

  • Response of air, silicon and dosimetric films to x-ray spectra of various qualities.

    abstract::Calculations have been performed of the kerma to radiographic film and to silicon from a number of x-ray spectra generated at 30 to 140 kV with tungsten and molybdenum targets. These results have been compared with the air-kerma values due to the same beams. It is concluded that both film and silicon can be used as pr...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Paix D

    更新日期:1992-12-01 00:00:00

  • Glaucoma detection using novel optic disc localization, hybrid feature set and classification techniques.

    abstract::Glaucoma is a chronic and irreversible neuro-degenerative disease in which the neuro-retinal nerve that connects the eye to the brain (optic nerve) is progressively damaged and patients suffer from vision loss and blindness. The timely detection and treatment of glaucoma is very crucial to save patient's vision. Compu...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0377-y

    authors: Akram MU,Tariq A,Khalid S,Javed MY,Abbas S,Yasin UU

    更新日期:2015-12-01 00:00:00

  • The impact of inhomogeneous tissue anisotropy on potential distribution within head model.

    abstract::This paper investigates the influence of inhomogeneous head tissue conductivity on EEGs. A head model with inhomogeneity of radial and tangential conductivity is built up. Based on this model the EEG signals are calculated using the finite elements method. The results show that the inhomogeneous radial and tangential ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178780

    authors: Wen P

    更新日期:2003-09-01 00:00:00

  • CT screening--whole-body and targeted.

    abstract::At present, the Australasian College of Physical Scientists and Engineers in Medicine does not support the practice of self-referred whole-body CT screening of asymptomatic patients because: The procedure involves a non-trivial radiation dose, which assumes even greater significance in the context of an ongoing screen...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 指南,杂志文章

    doi:10.1007/BF03178880

    authors: Le Heron JC,Coakley KS

    更新日期:2004-03-01 00:00:00

  • Echocardiographic assessment of long-term hemodynamic characteristics of mechanical mitral valve prostheses with different mitral valvular diseases.

    abstract::Mitral stenosis (MS) and mitral insufficiency (MI) have different pre-operative hemodynamic characteristics. However, it is unclear if there are differences in long-term echocardiographic characteristics of MS and MI patients after mechanical mitral valve replacement. This study is to compare long-term echocardiograph...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-016-0521-3

    authors: Zhu X,Li Q,Tang H,Xiao X

    更新日期:2017-03-01 00:00:00

  • Determination of RW3-to-water mass-energy absorption coefficient ratio for absolute dosimetry.

    abstract::The measurement of absorbed dose to water in a solid-phantom may require a conversion factor because it may not be radiologically equivalent to water. One phantom developed for the use of dosimetry is a solid water, RW3 white-polystyrene material by IBA. This has a lower mass-energy absorption coefficient than water d...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-011-0102-4

    authors: Seet KY,Hanlon PM,Charles PH

    更新日期:2011-12-01 00:00:00

  • Comparison of methods for measuring fractal dimension.

    abstract::Fractal dimension has been proposed as a useful method for characterizing medical images. The fractal dimension is calculated from the average radial power spectrum of the image. However, simpler methods of calculation have been proposed. This paper examines a very simple and easily implemented method which has been p...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Bartlett ML

    更新日期:1991-09-01 00:00:00

  • Investigating the impact of tumour motion on TomoTherapy stereotactic ablative body radiotherapy (SABR) deliveries on 3-dimensional and 4-dimensional computed tomography.

    abstract::TomoTherapy can provide highly accurate SABR deliveries, but currently it does not have any effective motion management techniques. Shallow breathing has been identified as one possible motion management solution on TomoTherapy, which has been made possible with the BreatheWell audiovisual biofeedback (AVB) device. Si...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-019-00727-8

    authors: Hu Y,Archibald-Heeren B,Byrne M,Cai E,Wang Y

    更新日期:2019-03-01 00:00:00

  • An assessment on the use of RadCalc to verify Raystation Electron Monte Carlo plans.

    abstract::Large differences in monitor units have been observed when RadCalc, a pencil-beam-algorithm based software, is used to verify clinical electron plans from Raystation, a Monte-Carlo-algorithm based planning system. To investigate the problem, a number of clinical plans as well as test plans were created and calculated ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-016-0470-x

    authors: Hu Y,Archibald-Heeren B,Byrne M,Wang Y

    更新日期:2016-09-01 00:00:00

  • Anatomical reduction and precise internal fixation of intra-articular fractures of the distal radius with virtual X-ray and 3D printing.

    abstract::To evaluate and precisely internal fix intra-articular distal radial fracture (IDRF) using the virtual X-ray and three-dimensional (3D) printing technologies. Twenty-one patients with IDRF were recruited, and the data from digital design group (DDG) and real surgery group (RSG) were collected and analyzed. In DDG, the...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-019-00795-w

    authors: Xu J,Zhang G,He Z,Zhong S,Chen Y,Wei C,Zheng Y,Lin H,Li W,Huang W

    更新日期:2019-10-22 00:00:00

  • Indices from lagged poincare plots of heart rate variability: an efficient nonlinear tool for emotion discrimination.

    abstract::Interest in human emotion recognition, regarding physiological signals, has recently risen. In this study, an efficient emotion recognition system, based on geometrical analysis of autonomic nervous system signals, is presented. The electrocardiogram recordings of 47 college students were obtained during rest conditio...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-017-0530-x

    authors: Goshvarpour A,Abbasi A,Goshvarpour A

    更新日期:2017-06-01 00:00:00

  • A study on contralateral breast surface dose for various tangential field techniques and the impact of set-up error on this dose.

    abstract::The risk of inducing contralateral breast (CLB) cancer in patients undergoing tangential field irradiation for the treatment of breast cancer is a serious concern in radiation oncology. A bilateral breast phantom made of wax attached onto the Alderson Rando phantom was used for studying the CLB dose for techniques usi...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178408

    authors: Prabhakar R,Haresh KP,Julka PK,Ganesh T,Rath GK,Joshi RC,Sasindran M,Naik KK,Sridhar PS

    更新日期:2007-03-01 00:00:00

  • Depth of anaesthesia assessment based on adult electroencephalograph beta frequency band.

    abstract::This paper presents a new method to apply timing characteristics of electroencephalograph (EEG) beta frequency bands to assess the depth of anaesthesia (DoA). Firstly, the measured EEG signals are denoised and decomposed into 20 different frequency bands. The Mobility (M), permutation entropy (PE) and Lempel-Ziv compl...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-016-0459-5

    authors: Li T,Wen P

    更新日期:2016-09-01 00:00:00

  • Medical physics aspects of cancer care in the Asia Pacific region: 2014 survey results.

    abstract::It was the aim of this work to assess and track the workload, working conditions and professional recognition of radiation oncology medical physicists (ROMPs) in the Asia Pacific region over time. In this third survey since 2008, a structured questionnaire was mailed in 2014 to 22 senior medical physicists representin...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0373-2

    authors: Kron T,Azhari HA,Voon EO,Cheung KY,Ravindran P,Soejoko D,Inamura K,Han Y,Ung NM,TsedenIsh B,Win UM,Srivastava R,Marsh S,Farrukh S,Rodriguez L,Kuo M,Baggarley S,DilipKumara AH,Lee CC,Krisanachinda A,Nguyen XC,Ng

    更新日期:2015-09-01 00:00:00

  • An investigation of central axis depth dose distribution perturbation due to an air gap between patient and bolus for electron beams.

    abstract::Electron beams can be used for the radiotherapy treatment of superficial cancers. In many cases of electron beam radiotherapy, tissue equivalent bolus material placed on the skin is to be used to enhance skin dose. An air gap might be present between the bolus and the skin due to variation in the patient contour. The ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178415

    authors: Kong M,Holloway L

    更新日期:2007-06-01 00:00:00

  • Medical physics in 2020: will we still be relevant?

    abstract::From the time when Roentgen and other physicists made the discoveries which led to the development of radiology, radiotherapy and nuclear medicine, medical physicists have played a pivotal role in the development of new technologies that have revolutionized the way medicine is practiced today. Medical physicists have ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type:

    doi:10.1007/BF03178583

    authors: Ng KH

    更新日期:2008-06-01 00:00:00

  • Computer-aided diagnosis system for classifying benign and malignant thyroid nodules in multi-stained FNAB cytological images.

    abstract::An automated computer-aided diagnosis system is developed to classify benign and malignant thyroid nodules using multi-stained fine needle aspiration biopsy (FNAB) cytological images. In the first phase, the image segmentation is performed to remove the background staining information and retain the appropriate foregr...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-013-0199-8

    authors: Gopinath B,Shanthi N

    更新日期:2013-06-01 00:00:00

  • AFOMP Policy Statement No. 3: recommendations for the education and training of medical physicists in AFOMP countries.

    abstract::AFOMP recognizes that clinical medical physicists should demonstrate that they are competent to practice their profession by obtaining appropriate education, training and supervised experience in the specialties of medical physics in which they practice, as well as having a basic knowledge of other specialties. To hel...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,评审

    doi:10.1007/s13246-011-0091-3

    authors: Round WH,Ng KH,Healy B,Rodriguez L,Thayalan K,Tang F,Fukuda S,Srivastava R,Krisanachinda A,Shiau AC,Deng X,Han Y

    更新日期:2011-09-01 00:00:00