Abstract:
:The aim of this study was to determine whether there is an effect of mobile phone electromagnetic field emissions on the human electroencephalograph (EEG). EEG recordings from ten awake subjects were taken during exposure to radiofrequency (RF) emissions from a mobile phone positioned behind the head. Two experimental trials were conducted. In the first trial, RF exposures were generated by a GSM mobile phone with the speaker disabled and configured to transmit at full-radiated power. During the second trial, exposures were generated by a non-modified GSM mobile phone in active standby mode. For each trial, subjects were exposed in five minute intervals to a randomized, interrupted sequence of five active and five sham exposures. The experiment was conducted under single-blind conditions. The average EEG band power in active exposure recordings was compared to corresponding sham recordings. Statistical tests indicated significant difference in the full-power mode trial within the EEG alpha (8-13 Hz) and beta (13-32 Hz) bands. A subsequent statistical analysis of median spectral power in discrete EEG rhythms revealed significant differences in 7 of the 32 distinct frequencies overall. In conclusion, the results of this study lend support to EEG effects from mobile phones activated in talk-mode.
journal_name
Australas Phys Eng Sci Medjournal_title
Australasian physical & engineering sciences in medicineauthors
D'Costa H,Trueman G,Tang L,Abdel-rahman U,Abdel-rahman W,Ong K,Cosic Idoi
10.1007/BF03179176subject
Has Abstractpub_date
2003-12-01 00:00:00pages
162-7issue
4eissn
0158-9938issn
1879-5447journal_volume
26pub_type
临床试验,杂志文章,随机对照试验abstract::Bio-signal based assessment for upper-limb functions is an attractive technology for rehabilitation. In this work, an upper-limb function evaluator is developed based on biological signals, which could be used for selecting different robotic training protocols. Interaction force (IF) and participation level (PL, proce...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-019-00783-0
更新日期:2019-09-01 00:00:00
abstract::Over 90% of craniopharyngeal brain tumors are cystic, which enables the injection of beta emitters such as phosphorus-32 (32P) radio-colloid into cysts for their treatment. The aim of this study was to evaluate the clinical and theoretical modelling of Bremsstrahlung radiation dose resulting from stereotactic radio-co...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-018-0665-4
更新日期:2018-09-01 00:00:00
abstract::Laparoscopic ultrasound (LUS) has been widely utilized as a surgical aide in general, urological, and gynecological applications. Our study summarizes the clinical applications of laparoscopic ultrasonography in laparoscopic gynecologic surgery. Retrospective analyses were performed on 42 women subjects using laparosc...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-015-0363-4
更新日期:2015-12-01 00:00:00
abstract::The assignment of pathogenicity to variants suspected of causing an inherited retinal disease and the subsequent creation of molecular genetic reports sent to clinical geneticists and ophthalmologists has traditionally been time-consuming and subject to error and ambiguity. The purpose of this paper is to describe a c...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-015-0420-z
更新日期:2016-03-01 00:00:00
abstract::A group of 113 children with poor vision who had been referred to the Electrodiagnostic Clinic over a five year period were investigated for disease of the retina and optic pathway by electroretinography (ERG), electro-oculography (EOG) and visual evoked response (VER). The electrodiagnostic measurements were made usi...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/BF03178360
更新日期:2001-09-01 00:00:00
abstract::From the time when Roentgen and other physicists made the discoveries which led to the development of radiology, radiotherapy and nuclear medicine, medical physicists have played a pivotal role in the development of new technologies that have revolutionized the way medicine is practiced today. Medical physicists have ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type:
doi:10.1007/BF03178583
更新日期:2008-06-01 00:00:00
abstract::The presence of metal artefacts in computed tomography (CT) create issues in radiation oncology. The loss of anatomical information and incorrect Hounsfield unit (HU) values produce inaccuracies in dose calculations, providing suboptimal patient treatment. Metal artefact reduction (MAR) algorithms were developed to co...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-017-0543-5
更新日期:2017-06-01 00:00:00
abstract::Bipolar disorder (BD) is a severe psychiatric disorder and has two common types: type I and type II. Early diagnosis of the subtypes is very challenging particularly in adolescence. In this study, 38 adolescents are participated including 18 patients with BD I and 20 patients with BD II. The electroencephalogram signa...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-015-0375-0
更新日期:2015-12-01 00:00:00
abstract::TomoTherapy can provide highly accurate SABR deliveries, but currently it does not have any effective motion management techniques. Shallow breathing has been identified as one possible motion management solution on TomoTherapy, which has been made possible with the BreatheWell audiovisual biofeedback (AVB) device. Si...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-019-00727-8
更新日期:2019-03-01 00:00:00
abstract::Shear wave elasticity imaging (SWEI) has been used to measure the local tissue elasticity. The local tissue shear modulus can be reconstructed from the displacement field of shear waves using an algebraic Helmholtz inversion (AHI) equation or a time-of-flight (TOF)-based algorithm. The shear waves, which are generated...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-019-00748-3
更新日期:2019-09-01 00:00:00
abstract::The umbilical cord is part of the fetus and generally includes one umbilical vein (UV) and two umbilical arteries (UAs). As the saphenous vein and UV are the most commonly used veins for the coronary artery disease treatment as a coronary artery bypass graft (CABG), understating the mechanical properties of UV has a k...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-014-0294-5
更新日期:2014-12-01 00:00:00
abstract::Diamond detectors are particularly well suited for dosimetry applications in radiotherapy for reasons including near-tissue equivalence and high-spatial resolution resulting from small sensitive volumes. However, these detectors have not become commonplace due to high cost and poor availability arising from the need f...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-010-0040-6
更新日期:2010-12-01 00:00:00
abstract::The Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) radiation oncology specialty group (ROSG) formed a series of working groups in 2011 to develop recommendations for guidance of radiation oncology medical physics practice within the Australasian setting. These recommendations are intend...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章,实务指引
doi:10.1007/s13246-015-0344-7
更新日期:2015-06-01 00:00:00
abstract::X-ray transmission tests were performed on a Green-Lite (Infab Corporation) apron/vest combination, and compared to a number of other apron/vest combinations routinely used at Christchurch Hospital as well as a sheet of 0.5 mm lead. The materials were X-rayed using the primary beam of a Philips Optimus 50 X-ray machin...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/BF03178704
更新日期:2005-06-01 00:00:00
abstract::This paper investigates the influence of inhomogeneous head tissue conductivity on EEGs. A head model with inhomogeneity of radial and tangential conductivity is built up. Based on this model the EEG signals are calculated using the finite elements method. The results show that the inhomogeneous radial and tangential ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/BF03178780
更新日期:2003-09-01 00:00:00
abstract::Post installation acceptance testing is vital to demonstrate that the equipment meets the vendor's specification and is suitable for clinical studies. The test procedures described in the NEMA NU 2-2001 document form the basis of vendor performance specifications of PET scanners and hence are also appropriate for acce...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-010-0016-6
更新日期:2010-06-01 00:00:00
abstract::Transmission data for a fibre cement wallboard (villaboard) are determined for use in diagnostic shielding designs. Villaboard is found to be more attenuating than plasterboard e.g. 9 mm of villaboard is equivalent to 16 mm of plasterboard. ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1998-09-01 00:00:00
abstract::Regular checks on the performance of radiotherapy treatment units are essential and a variety of protocols has been published. These protocols identify that the determination of isocentre must be accurate and unambiguous since both the localization of a radiation field on a patient and positioning aids are referenced ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/BF03178670
更新日期:2004-09-01 00:00:00
abstract::The accuracy of a computed tomography (CT)-relative electron density (RED) curve may have an indirect impact on the accuracy of dose calculation by a treatment planning system (TPS). This effect has not been previously quantified for input of different CT-RED curves from different CT-scan units in the Monaco TPS. This...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-019-00745-6
更新日期:2019-06-01 00:00:00
abstract::This paper describes a software tool developed for research into the use of an electronic portal imaging device (EPID) to verify dose for intensity modulated radiation therapy (IMRT) beams. A portal dose image prediction (PDIP) model that predicts the EPID response to IMRT beams has been implemented into a commerciall...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/BF03179347
更新日期:2008-09-01 00:00:00
abstract::Despite ongoing active research, the role of the radiation bystander effect in modifying local tissue response to an ionising radiation dose remains unclear. The present study aims to provide new insight by simulating the diffusion-mediated inter-cellular communication processes in 2D and 3D cell-like structures to ca...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-010-0048-y
更新日期:2011-04-01 00:00:00
abstract::Sometimes infusion pumps are used to deliver whole blood to patients. However, in doing so there is a potential for damage to red cells from mechanical stresses in the pump, resulting in haemolysis. In order to investigate the degree of haemolysis caused by different pumps and therefore their suitability for whole blo...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1991-03-01 00:00:00
abstract::This paper proposes a novel approach to detect epilepsy seizures by using Electroencephalography (EEG), which is one of the most common methods for the diagnosis of epilepsy, based on 1-Dimension Local Binary Pattern (1D-LBP) and grey relational analysis (GRA) methods. The main aim of this paper is to evaluate and val...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-015-0362-5
更新日期:2015-09-01 00:00:00
abstract::The alcoholism can be detected by analyzing electroencephalogram (EEG) signals. However, analyzing multi-channel EEG signals is a challenging task, which often requires complicated calculations and long execution time. This paper proposes three data selection methods to extract representative data from the EEG signals...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-015-0414-x
更新日期:2016-03-01 00:00:00
abstract::Helical tomotherapy (HT) is a novel radiotherapy treatment modality that allows the delivery of intensity modulated radiation in a rotational fashion. Due to the complexity of the treatment approach, it is desirable to have a simple tool for treatment delivery verification. Radiographic film placed under the patient i...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/BF03178723
更新日期:2005-12-01 00:00:00
abstract::This note investigates in-vivo dosimetry using a Metal Oxide Semiconductor Field Effect Transistor (MOSFET) for radiotherapy treatment at superficial and orthovoltage x-ray energies. This was performed within one fraction of the patients treatment. Standard measurements along with energy response of the detector are g...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:2003-06-01 00:00:00
abstract::AFOMP recognizes that clinical medical physicists should demonstrate that they are competent to practice their profession by obtaining appropriate education, training and supervised experience in the specialties of medical physics in which they practice, as well as having a basic knowledge of other specialties. To hel...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章,评审
doi:10.1007/s13246-011-0091-3
更新日期:2011-09-01 00:00:00
abstract::A variable magnetic deflector which attaches onto the treatment head of a linear accelerator has reduced skin dose by as much as 65% for 6MV x-rays. The magnetic deflector is constructed from Neodymium Iron Boron (NdFeB) rare earth magnets. It weighs approximately 15 kg and is designed to easily fit onto the accessory...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1997-06-01 00:00:00
abstract::A new PTW advanced Markus ionization chamber has been implemented in IMRT fields, to measure surface dose at ICRU and ICRP reference depth of 0.07 mm [ICRU Report 39, Determination of dose equivalents resulting from external radiation sources, 1985; ICRP Publication 60, 1990 recommendations of the International Commis...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-010-0004-x
更新日期:2010-03-01 00:00:00
abstract::In this study, we assessed the accuracy of surface doses determined by direct measurement and treatment planning system (TPS) calculations, relative to benchmark Monte Carlo (MC) doses calculated at 70 μm for a 6 MV, 10 × 10 cm clinical radiotherapy beam. In a homogeneous phantom with both open and fixed wedged fields...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-012-0145-1
更新日期:2012-09-01 00:00:00