ACPSEM ROSG TBI working group recommendations for quality assurance in total body irradiation.

Abstract:

:The Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) radiation oncology specialty group (ROSG) formed a series of working groups in 2011 to develop recommendations for guidance of radiation oncology medical physics practice within the Australasian setting. These recommendations are intended to provide guidance for safe work practices and a suitable level of quality control without detailed work instructions. It is the responsibility of the medical physicist to ensure that locally available equipment and procedures are sufficiently sensitive to establish compliance to these recommendations. The recommendations are endorsed by the ROSG, and have been subject to independent expert reviews. For the Australian audience, these recommendations should be read in conjunction with the tripartite radiation oncology practice standards [1, 2]. This publication presents the recommendations of the ACPSEM total body irradiation working group (TBIWG) and has been developed in alignment with other international associations. However, these recommendations should be read in conjunction with relevant national, state or territory legislation and local requirements, which take precedence over the ACPSEM recommendations. It is hoped that the users of this and other ACPSEM recommendations will contribute to the development of future versions through the ROSG of the ACPSEM. This document serves as a guideline for calibration and quality assurance of equipment used for TBI in Australasia.

authors

Nelligan R,Bailey M,Tran T,Baldwin Z,ACPSEM total body irradiation working group.

doi

10.1007/s13246-015-0344-7

subject

Has Abstract

pub_date

2015-06-01 00:00:00

pages

205-15

issue

2

eissn

0158-9938

issn

1879-5447

journal_volume

38

pub_type

杂志文章,实务指引
  • Optimal selection of mother wavelet for accurate infant cry classification.

    abstract::Wavelet theory is emerging as one of the prevalent tool in signal and image processing applications. However, the most suitable mother wavelet for these applications is still a relative question mark amongst researchers. Selection of best mother wavelet through parameterization leads to better findings for the analysi...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-014-0264-y

    authors: Saraswathy J,Hariharan M,Nadarajaw T,Khairunizam W,Yaacob S

    更新日期:2014-06-01 00:00:00

  • SAR and temperature distribution in the rat head model exposed to electromagnetic field radiation by 900 MHz dipole antenna.

    abstract::Rats are often used in the electromagnetic field (EMF) exposure experiments. In the study for the effect of 900 MHz EMF exposure on learning and memory in SD rats, the specific absorption rate (SAR) and the temperature rise in the rat head are numerically evaluated. The digital anatomical model of a SD rat is reconstr...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-013-0202-4

    authors: Yang L,Hao D,Wu S,Zhong R,Zeng Y

    更新日期:2013-06-01 00:00:00

  • Supervised segmentation of MRI brain images using combination of multiple classifiers.

    abstract::Segmentation of different tissues is one of the initial and most critical tasks in different aspects of medical image processing. Manual segmentation of brain images resulted from magnetic resonance imaging is time consuming, so automatic image segmentation is widely used in this area. Ensemble based algorithms are ve...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0352-7

    authors: Ahmadvand A,Sharififar M,Daliri MR

    更新日期:2015-06-01 00:00:00

  • AFOMP Policy Statement No. 3: recommendations for the education and training of medical physicists in AFOMP countries.

    abstract::AFOMP recognizes that clinical medical physicists should demonstrate that they are competent to practice their profession by obtaining appropriate education, training and supervised experience in the specialties of medical physics in which they practice, as well as having a basic knowledge of other specialties. To hel...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,评审

    doi:10.1007/s13246-011-0091-3

    authors: Round WH,Ng KH,Healy B,Rodriguez L,Thayalan K,Tang F,Fukuda S,Srivastava R,Krisanachinda A,Shiau AC,Deng X,Han Y

    更新日期:2011-09-01 00:00:00

  • Development of a method for manufacturing customized nasal mask cushion for CPAP therapy.

    abstract::A continuous positive airway pressure (CPAP) device is considered one of the most effective treatments for obstructive sleep apnea (OSA). However, many patients receiving this treatment complain of mask discomfort and other issues. Therefore, this study aimed to develop a customized nasal mask cushion to reduce the di...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0383-0

    authors: Hsu DY,Cheng YL,Bien MY,Lee HC

    更新日期:2015-12-01 00:00:00

  • A low cost ECG central station for intensive care.

    abstract::A electrocardiogram (ECG) central station has been developed for the Intensive Care Unit at Christchurch Hospital. The system allows the selection and display of four ECGs selected from seven bedside monitors in the Unit. It also provides for automatic display, hard copy and audio alarm of ECG from any monitor which h...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Jans R,Elder AG,Jones RD,Fright WR,Bones PJ

    更新日期:1990-03-01 00:00:00

  • Reliability of the Cobb angle index derived by traditional and computer assisted methods.

    abstract::The reliability of the traditional Cobb angle index, which at present exhibits a wide range of reported values, was determined in this study and amounted to a within subject error of +/-4.3 degrees and a between subject error of +/-4.9 degrees. An attempt to pinpoint the source of this variability by investigating the...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Dutton KE,Jones TJ,Slinger BS,Scull ER,O'Connor J

    更新日期:1989-03-01 00:00:00

  • A new approach to dose estimation and in-phantom figure of merit measurement in BNCT by using artificial neural networks.

    abstract::In-phantom figures of merit of the radiobiological dose distribution are the main criteria for evaluation of the boron neutron capture therapy (BNCT) plan and neutron beam evaluation. Since in BNCT there are several reactions, which contribute to the total dose of the tissue, the calculation of the dose distribution i...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-011-0107-z

    authors: Ahangari R,Afarideh H

    更新日期:2011-12-01 00:00:00

  • Neuro-muscular junction block stimulator simulator.

    abstract::Improved technology and higher fidelity are making medical simulations increasingly popular. A simulated peripheral nerve stimulator and thumb actuator has been developed for use with the SimMan Universal Patient Simulator. This device incorporates a handheld control box, a McKibben pneumatic muscle and articulated th...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Sprick C

    更新日期:2006-03-01 00:00:00

  • A feature study of innovative high-speed lancing device and safety lancet.

    abstract::The study developed two models of an innovative high-speed lancing device and safety lancet, where the specially designed structure causes high-speed motion of the lancet, resulting in only one puncture of the skin. The two experimental models and other lancing devices sold on market were compared in order to: (1) mea...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-016-0490-6

    authors: Chang H,Yeh YJ,Lee R,Shyu JH

    更新日期:2016-12-01 00:00:00

  • An application of linear output error modelling for studying lymphocyte migration in peripheral lymphoid tissues.

    abstract::Lymphocyte recirculation between lymphatic and blood vessels and migration through tissues are essential mechanisms underlying immunological surveillance. However, the kinetics of lymphocyte migration through lymphoid tissues remains poorly understood. The present study of lymphocyte migration, based on a sheep model ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178774

    authors: Srikusalanukul W,De Bruyne F,McCullagh P

    更新日期:2002-09-01 00:00:00

  • Polymer gel dosimeters with PVA-GA matrix.

    abstract::Properties of a new polymer gel with cross-linked polyvinyl alcohol as a gelatinous matrix were investigated. The new polymer gel dosimeter was named PVABAT. The irradiation was performed using a calibrated 60Co beam. The dose responses of the PVABAT formulations were quantified with MRI transverse relaxation rate (R2...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-017-0573-z

    authors: Abtahi SMM,Sadeghi Abandansari H

    更新日期:2017-09-01 00:00:00

  • Dose computations for three-dimensional radiation treatment planning.

    abstract::The knowledge of radiation dose at all points of interest within a patient's body is essential for the evaluation of treatment plans and for the judicious selection of the best one from among a set of competing plans. This paper discusses the physical and geometric aspects of radiation dose distribution calculations n...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Mohan R

    更新日期:1989-12-01 00:00:00

  • Determination of correct AEC function with computed radiography cassettes.

    abstract::It has long been recognized that the assessment of Automatic Exposure Control (AEC) function is an important criterion in the assessment of any general radiographic x-ray installation. Of the tests commonly performed on an AEC, only Beam Quality Dependence relates intimately with the optical density produced on the re...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Wilkinson LE,Heggie JC

    更新日期:1997-09-01 00:00:00

  • Surface electromyographic analysis of the biceps brachii muscle of cricket bowlers during bowling.

    abstract::Cricket bowling generates forces with torques on the upper limb muscles and makes the biceps brachii (BB) muscle vulnerable to overuse injury. The aim of this study was to investigate whether there are differences in the amplitude of the EMG signal of the BB muscle during fast and spin delivery, during the seven phase...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-014-0245-1

    authors: Ahamed NU,Sundaraj K,Ahmad B,Rahman M,Ali MA,Islam MA

    更新日期:2014-03-01 00:00:00

  • The use of round ended needles for high dose rate brachytherapy implants.

    abstract::The use of Speiser needles for interstitial implants has resulted in malfunctioning of HDR afterloading equipment due to seepage of blood. We have successfully used rounded ended needles in the patient after removal of the trocar ended needles, preventing the seepage of blood. This technique also helps to prevent any ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Das KR,Duchesne G,Coles JR,Pinder P

    更新日期:1999-12-01 00:00:00

  • Biomathematical modelling of physiological fluids using a Casson fluid with emphasis to peristalsis.

    abstract::In this paper, the peristaltic flow of rheologically complex physiological fluids when modelled by a non-Newtonian Casson fluid in a two-dimensional channel is considered. Of interest is the difference between peristaltic transport of Newtonian and non-Newtonian fluids. A perturbation series method of solution of the ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Mernone AV,Mazumdar JN

    更新日期:2000-09-01 00:00:00

  • Using EGS4 Monte Carlo in medical radiation physics.

    abstract::Monte Carlo modelling of particle transport problems in medical radiation physics offers significant advantages over other techniques. Experiments can be performed without having to set up the physical situation, and "impossible" experiments can be performed, such as labelling multiple-scattered particles or simulatin...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type:

    doi:

    authors: Murray D

    更新日期:1990-09-01 00:00:00

  • Comparison of skin dose between conventional radiotherapy and IMRT.

    abstract::The purpose of this study was to measure skin dose using radiochromic film for two step-and-shoot IMRT fields and compare the results to the skin dose for a conventional open field. All exposures were made using a 6 MV photon beam produced by a Varian 21EX linear accelerator (Varian Medical Systems, CA, USA) equipped ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178577

    authors: Price S,Williams M,Butson M,Metcalfe P

    更新日期:2006-09-01 00:00:00

  • Performance of independent dose calculation in helical tomotherapy: implementation of the MCSIM code.

    abstract::Currently, a software-based second check dose calculation for helical tomotherapy (HT) is not available. The goal of this study is to evaluate the dose calculation accuracy of the in-house software using EGS4/MCSIM Monte Carlo environment against the treatment planning system calculations. In-house software was used t...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-012-0165-x

    authors: Dzintars E,Stathakis S,Mavroidis P,Sadeghi A,Papanikolaou N

    更新日期:2012-12-01 00:00:00

  • A computer-assisted method for pathogenicity assessment and genetic reporting of variants stored in the Australian Inherited Retinal Disease Register.

    abstract::The assignment of pathogenicity to variants suspected of causing an inherited retinal disease and the subsequent creation of molecular genetic reports sent to clinical geneticists and ophthalmologists has traditionally been time-consuming and subject to error and ambiguity. The purpose of this paper is to describe a c...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0420-z

    authors: Huynh E,De Roach J,McLaren T,Thompson J,Montgomery H,Kap C,Hoffmann L,Lamey T

    更新日期:2016-03-01 00:00:00

  • Diagnostic x-ray spectra simulation, verification and application to the clinical environment.

    abstract::A set of computer programs to simulate diagnostic x-ray spectra has been developed according to the method of Birch and Marshall, with good agreement to published HPA data. These programs have been extended to simulate spectra generated with capacitor discharge x-ray units. The application of these programs has proved...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: McLean D

    更新日期:1989-09-01 00:00:00

  • MOSFET dosimetry in-vivo at superficial and orthovoltage x-ray energies.

    abstract::This note investigates in-vivo dosimetry using a Metal Oxide Semiconductor Field Effect Transistor (MOSFET) for radiotherapy treatment at superficial and orthovoltage x-ray energies. This was performed within one fraction of the patients treatment. Standard measurements along with energy response of the detector are g...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Cheung T,Butson MJ,Yu PK

    更新日期:2003-06-01 00:00:00

  • Evaluation of Bremsstrahlung radiation dose in stereotactically radiocolloid therapy of cystic craniopharyngioma tumors with 32P radio-colloid.

    abstract::Over 90% of craniopharyngeal brain tumors are cystic, which enables the injection of beta emitters such as phosphorus-32 (32P) radio-colloid into cysts for their treatment. The aim of this study was to evaluate the clinical and theoretical modelling of Bremsstrahlung radiation dose resulting from stereotactic radio-co...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-018-0665-4

    authors: Babaei M,Ghahramani-Asl R,Sadoughi HR,Sardari D,Shahzadi S

    更新日期:2018-09-01 00:00:00

  • Position paper: recommendations for a digital mammography quality assurance program V4.0.

    abstract::In 2001 the ACPSEM published a position paper on quality assurance in screen film mammography which was subsequently adopted as a basis for the quality assurance programs of both the Royal Australian and New Zealand College of Radiologists (RANZCR) and of BreastScreen Australia. Since then the clinical implementation ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-017-0583-x

    authors: Heggie JCP,Barnes P,Cartwright L,Diffey J,Tse J,Herley J,McLean ID,Thomson FJ,Grewal RK,Collins LT

    更新日期:2017-09-01 00:00:00

  • The impact of inhomogeneous tissue anisotropy on potential distribution within head model.

    abstract::This paper investigates the influence of inhomogeneous head tissue conductivity on EEGs. A head model with inhomogeneity of radial and tangential conductivity is built up. Based on this model the EEG signals are calculated using the finite elements method. The results show that the inhomogeneous radial and tangential ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178780

    authors: Wen P

    更新日期:2003-09-01 00:00:00

  • Intensity modulated radiation therapy (IMRT) surface dose measurements using a PTW advanced Markus chamber.

    abstract::A new PTW advanced Markus ionization chamber has been implemented in IMRT fields, to measure surface dose at ICRU and ICRP reference depth of 0.07 mm [ICRU Report 39, Determination of dose equivalents resulting from external radiation sources, 1985; ICRP Publication 60, 1990 recommendations of the International Commis...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-010-0004-x

    authors: Chen FQ,Gupta R,Metcalfe P

    更新日期:2010-03-01 00:00:00

  • Film dosimetry for the junction region of four compensated photon beams.

    abstract::A set of four 4 MV photon beam compensators were produced, one for each field of a Hodgkins Disease treatment plan. The resultant dose profiles at various depths were measured by an ion chamber in water and by Kodak X-Omat V film in a Solid Water phantom, and compared to the doses calculated by a GE RT/Plan treatment ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Ralston AC,Francis JW

    更新日期:1992-03-01 00:00:00

  • Improved accuracy of 3D-printed navigational template during complicated tibial plateau fracture surgery.

    abstract::This study was aimed to improve the surgical accuracy of plating and screwing for complicated tibial plateau fracture assisted by 3D implants library and 3D-printed navigational template. Clinical cases were performed whereby complicated tibial plateau fractures were imaged using computed tomography and reconstructed ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0330-0

    authors: Huang H,Hsieh MF,Zhang G,Ouyang H,Zeng C,Yan B,Xu J,Yang Y,Wu Z,Huang W

    更新日期:2015-03-01 00:00:00

  • Physiologic outcome of varying speed rotary blood pump support algorithms: a review study.

    abstract::Rotary blood pumps have the potential to become a viable long-term treatment option for the heart failure patients to bridge to transplantation or destination therapy. However, these devices operate at a constant speed which may lead to long term complications or they may operate in an undesired support mode such as e...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,评审

    doi:10.1007/s13246-015-0405-y

    authors: Bozkurt S

    更新日期:2016-03-01 00:00:00