Abstract:
:Lymphocyte recirculation between lymphatic and blood vessels and migration through tissues are essential mechanisms underlying immunological surveillance. However, the kinetics of lymphocyte migration through lymphoid tissues remains poorly understood. The present study of lymphocyte migration, based on a sheep model and entailing the long term cannulation of blood vessels and lymphatic vessels efferent from lymph nodes, represents the first attempt to apply control engineering based models to overcome some of the experimental impediments to understanding the complex phenomena involved in lymphocyte migration. An output error model order (1,2,nk) was systematically selected under given criteria from four classes of Linear Time-Invariant Single-Input Single-Output, (LTI-SISO) systems to represent the peripheral lymph node system. The unit impulse responses were simulated under noise free conditions and their features were extracted to describe the dynamics of the system. The findings from this study revealed novel information about several aspects of the dynamics of lymphocyte migration.
journal_name
Australas Phys Eng Sci Medjournal_title
Australasian physical & engineering sciences in medicineauthors
Srikusalanukul W,De Bruyne F,McCullagh Pdoi
10.1007/BF03178774subject
Has Abstractpub_date
2002-09-01 00:00:00pages
132-8issue
3eissn
0158-9938issn
1879-5447journal_volume
25pub_type
杂志文章abstract::This article outlines the enormous technological advances that have taken place in the practice of radiology in Australasia in the 30 years since approximately 1977. These developments have led to significant improvements in image quality across all modalities, including even general radiography, which had as its gene...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章,评审
doi:10.1007/BF03178423
更新日期:2007-09-01 00:00:00
abstract::A study was made of calibrating the NACP plane parallel chamber in electron beams from linear accelerators of a different manufacture with energies, Ep,o' from 4.4 to 19.1 MeV, and also in 4 and 6 MV photon beams as well as a cobalt60 beam. The photon beam measurements were both IN-AIR and IN-PHANTOM. With the excepti...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1996-09-01 00:00:00
abstract::Electron beams can be used for the radiotherapy treatment of superficial cancers. In many cases of electron beam radiotherapy, tissue equivalent bolus material placed on the skin is to be used to enhance skin dose. An air gap might be present between the bolus and the skin due to variation in the patient contour. The ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/BF03178415
更新日期:2007-06-01 00:00:00
abstract::In this study, we assessed the accuracy of surface doses determined by direct measurement and treatment planning system (TPS) calculations, relative to benchmark Monte Carlo (MC) doses calculated at 70 μm for a 6 MV, 10 × 10 cm clinical radiotherapy beam. In a homogeneous phantom with both open and fixed wedged fields...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-012-0145-1
更新日期:2012-09-01 00:00:00
abstract::The reliability of the traditional Cobb angle index, which at present exhibits a wide range of reported values, was determined in this study and amounted to a within subject error of +/-4.3 degrees and a between subject error of +/-4.9 degrees. An attempt to pinpoint the source of this variability by investigating the...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1989-03-01 00:00:00
abstract::The Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) Radiation Oncology Specialty Group (ROSG) formed a series of working groups in 2011 to develop position papers for guidance of radiation oncology medical physics practice within the Australasian setting. These position papers are intend...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-013-0238-5
更新日期:2014-03-01 00:00:00
abstract::Diamond detectors are particularly well suited for dosimetry applications in radiotherapy for reasons including near-tissue equivalence and high-spatial resolution resulting from small sensitive volumes. However, these detectors have not become commonplace due to high cost and poor availability arising from the need f...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-010-0040-6
更新日期:2010-12-01 00:00:00
abstract::Given that there is increasing recognition of the effect that sub-millimetre changes in collimator position can have on radiotherapy beam dosimetry, this study aimed to evaluate the potential variability in small field collimation that may exist between otherwise matched linacs. Field sizes and field output factors we...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-015-0349-2
更新日期:2015-06-01 00:00:00
abstract::The measurement of absorbed dose to water in a solid-phantom may require a conversion factor because it may not be radiologically equivalent to water. One phantom developed for the use of dosimetry is a solid water, RW3 white-polystyrene material by IBA. This has a lower mass-energy absorption coefficient than water d...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-011-0102-4
更新日期:2011-12-01 00:00:00
abstract::A continuous positive airway pressure (CPAP) device is considered one of the most effective treatments for obstructive sleep apnea (OSA). However, many patients receiving this treatment complain of mask discomfort and other issues. Therefore, this study aimed to develop a customized nasal mask cushion to reduce the di...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-015-0383-0
更新日期:2015-12-01 00:00:00
abstract::It has long been recognized that the assessment of Automatic Exposure Control (AEC) function is an important criterion in the assessment of any general radiographic x-ray installation. Of the tests commonly performed on an AEC, only Beam Quality Dependence relates intimately with the optical density produced on the re...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1997-09-01 00:00:00
abstract::In recent years, the use of gold nanoparticles in radiation therapy has been introduced as a new approach in radiotherapy. The aim of this study is to investigate the effect of gold nanoparticles (GNPs) in plaque brachytherapy for choroidal melanoma using Monte Carlo (MC) simulation. MCNPX code was used for simulation...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-017-0555-1
更新日期:2017-09-01 00:00:00
abstract::Laparoscopic ultrasound (LUS) has been widely utilized as a surgical aide in general, urological, and gynecological applications. Our study summarizes the clinical applications of laparoscopic ultrasonography in laparoscopic gynecologic surgery. Retrospective analyses were performed on 42 women subjects using laparosc...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-015-0363-4
更新日期:2015-12-01 00:00:00
abstract::Large differences in monitor units have been observed when RadCalc, a pencil-beam-algorithm based software, is used to verify clinical electron plans from Raystation, a Monte-Carlo-algorithm based planning system. To investigate the problem, a number of clinical plans as well as test plans were created and calculated ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-016-0470-x
更新日期:2016-09-01 00:00:00
abstract::Currently, a software-based second check dose calculation for helical tomotherapy (HT) is not available. The goal of this study is to evaluate the dose calculation accuracy of the in-house software using EGS4/MCSIM Monte Carlo environment against the treatment planning system calculations. In-house software was used t...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-012-0165-x
更新日期:2012-12-01 00:00:00
abstract::The Resonant Recognition Model (rrm) uses digital signal processing methods to investigate protein structure-function; and links the biological function of protein families to unique characteristic frequencies. The rrm originally used a single set of variables: the electron ion interaction potential (EIIP). Here the r...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1995-12-01 00:00:00
abstract::A 69 year old male was treated with an ablative dose of 3.7 GBq (100 mCi) of I131 for carcinoma of the thyroid and died 10 days after administration. The requirement for an autopsy and the level of radiation still present in the body necessitated the intervention of Radiation Safety Personnel to minimise support staff...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1991-06-01 00:00:00
abstract::In 2001 the ACPSEM published a position paper on quality assurance in screen film mammography which was subsequently adopted as a basis for the quality assurance programs of both the Royal Australian and New Zealand College of Radiologists (RANZCR) and of BreastScreen Australia. Since then the clinical implementation ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-017-0583-x
更新日期:2017-09-01 00:00:00
abstract::A set of four 4 MV photon beam compensators were produced, one for each field of a Hodgkins Disease treatment plan. The resultant dose profiles at various depths were measured by an ion chamber in water and by Kodak X-Omat V film in a Solid Water phantom, and compared to the doses calculated by a GE RT/Plan treatment ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1992-03-01 00:00:00
abstract::Monte Carlo modelling of particle transport problems in medical radiation physics offers significant advantages over other techniques. Experiments can be performed without having to set up the physical situation, and "impossible" experiments can be performed, such as labelling multiple-scattered particles or simulatin...
journal_title:Australasian physical & engineering sciences in medicine
pub_type:
doi:
更新日期:1990-09-01 00:00:00
abstract::The sample entropy (SampEn) has been widely used to quantify the complexity of RR-interval time series. It is a fact that higher complexity, and hence, entropy is associated with the RR-interval time series of healthy subjects. But, SampEn suffers from the disadvantage that it assigns higher entropy to the randomized ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-016-0457-7
更新日期:2016-09-01 00:00:00
abstract::This study was aimed to improve the surgical accuracy of plating and screwing for complicated tibial plateau fracture assisted by 3D implants library and 3D-printed navigational template. Clinical cases were performed whereby complicated tibial plateau fractures were imaged using computed tomography and reconstructed ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-015-0330-0
更新日期:2015-03-01 00:00:00
abstract::This paper investigates the influence of inhomogeneous head tissue conductivity on EEGs. A head model with inhomogeneity of radial and tangential conductivity is built up. Based on this model the EEG signals are calculated using the finite elements method. The results show that the inhomogeneous radial and tangential ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/BF03178780
更新日期:2003-09-01 00:00:00
abstract::Linear scaling is used to convert raw computed tomography (CT) pixel values into Hounsfield units corresponding to different tissue values. Analysis of a benchmarking study, presented here, where the same CT scan was imported into and then exported from multiple radiotherapy treatment planning systems, found inconsist...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-018-0651-x
更新日期:2018-09-01 00:00:00
abstract::Given the difficulty and potential time- or financial-costs associated with accurate small field dosimetry, this study aimed to establish the clinical necessity of obtaining accurate small field output factor measurements and to evaluate the effects on planned doses that could arise if accurate measurements are not us...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-016-0461-y
更新日期:2016-09-01 00:00:00
abstract::Sometimes infusion pumps are used to deliver whole blood to patients. However, in doing so there is a potential for damage to red cells from mechanical stresses in the pump, resulting in haemolysis. In order to investigate the degree of haemolysis caused by different pumps and therefore their suitability for whole blo...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1991-03-01 00:00:00
abstract::The Australian Clinical Dosimetry Service (ACDS) has demonstrated the capacity to perform a basic dosimetry audit on all radiotherapy clinics across Australia. During the ACDS's three and a half year trial the majority of the audits were performed using optically stimulated luminescence dosimeters (OSLD) mailed to fac...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-014-0320-7
更新日期:2015-03-01 00:00:00
abstract::Magnetic resonance imaging has become a key modality within the modern radiology department. In addition to the conventional slice images, three dimensional angiographic images, and quantitative flow measurements can be obtained. More recently methods have been developed which enable one to visualize the motion of obj...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章,评审
doi:
更新日期:1991-12-01 00:00:00
abstract::Arrhythmia is slow, fast or irregular heartbeat. Manual ECG assessment and disease classification is an error-prone task because of vast differences in ECG morphology and difficulty in accurate identifying ECG components. Moreover, proposing a computer-aided diagnosis system for heartbeat classification can be useful ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-019-00814-w
更新日期:2019-11-26 00:00:00
abstract::Thermoluminescence dosimetry (TLD) is a versatile tool for the assessment of dose from ionising radiation. The wide variety of TLD materials and their different physical forms allow the determination of different radiation qualities at dose levels from microGy to kGy. Major advantages of TL dosimeters are their small ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章,评审
doi:
更新日期:1994-12-01 00:00:00