Complexity quantification of cardiac variability time series using improved sample entropy (I-SampEn).

Abstract:

:The sample entropy (SampEn) has been widely used to quantify the complexity of RR-interval time series. It is a fact that higher complexity, and hence, entropy is associated with the RR-interval time series of healthy subjects. But, SampEn suffers from the disadvantage that it assigns higher entropy to the randomized surrogate time series as well as to certain pathological time series, which is a misleading observation. This wrong estimation of the complexity of a time series may be due to the fact that the existing SampEn technique updates the threshold value as a function of long-term standard deviation (SD) of a time series. However, time series of certain pathologies exhibits substantial variability in beat-to-beat fluctuations. So the SD of the first order difference (short term SD) of the time series should be considered while updating threshold value, to account for period-to-period variations inherited in a time series. In the present work, improved sample entropy (I-SampEn), a new methodology has been proposed in which threshold value is updated by considering the period-to-period variations of a time series. The I-SampEn technique results in assigning higher entropy value to age-matched healthy subjects than patients suffering atrial fibrillation (AF) and diabetes mellitus (DM). Our results are in agreement with the theory of reduction in complexity of RR-interval time series in patients suffering from chronic cardiovascular and non-cardiovascular diseases.

authors

Marwaha P,Sunkaria RK

doi

10.1007/s13246-016-0457-7

subject

Has Abstract

pub_date

2016-09-01 00:00:00

pages

755-63

issue

3

eissn

0158-9938

issn

1879-5447

pii

10.1007/s13246-016-0457-7

journal_volume

39

pub_type

杂志文章
  • ACPSEM ROSG TBI working group recommendations for quality assurance in total body irradiation.

    abstract::The Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) radiation oncology specialty group (ROSG) formed a series of working groups in 2011 to develop recommendations for guidance of radiation oncology medical physics practice within the Australasian setting. These recommendations are intend...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,实务指引

    doi:10.1007/s13246-015-0344-7

    authors: Nelligan R,Bailey M,Tran T,Baldwin Z,ACPSEM total body irradiation working group.

    更新日期:2015-06-01 00:00:00

  • Comparison study of different head model structures with homogeneous/inhomogeneous conductivity.

    abstract::Most of the human head models used in dipole localisation research, which have been reported in the literature to date, assume a simplified cranial structure wherein the head is modelled as a set of distinct homogenous tissue compartments. The inherent inhomogeneity of the tissues has so far been ignored in these mode...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178283

    authors: Wen P,Li Y

    更新日期:2001-03-01 00:00:00

  • The use of round ended needles for high dose rate brachytherapy implants.

    abstract::The use of Speiser needles for interstitial implants has resulted in malfunctioning of HDR afterloading equipment due to seepage of blood. We have successfully used rounded ended needles in the patient after removal of the trocar ended needles, preventing the seepage of blood. This technique also helps to prevent any ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Das KR,Duchesne G,Coles JR,Pinder P

    更新日期:1999-12-01 00:00:00

  • Proposing feature engineering method based on deep learning and K-NNs for ECG beat classification and arrhythmia detection.

    abstract::Arrhythmia is slow, fast or irregular heartbeat. Manual ECG assessment and disease classification is an error-prone task because of vast differences in ECG morphology and difficulty in accurate identifying ECG components. Moreover, proposing a computer-aided diagnosis system for heartbeat classification can be useful ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-019-00814-w

    authors: Khatibi T,Rabinezhadsadatmahaleh N

    更新日期:2019-11-26 00:00:00

  • Dose computations for three-dimensional radiation treatment planning.

    abstract::The knowledge of radiation dose at all points of interest within a patient's body is essential for the evaluation of treatment plans and for the judicious selection of the best one from among a set of competing plans. This paper discusses the physical and geometric aspects of radiation dose distribution calculations n...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Mohan R

    更新日期:1989-12-01 00:00:00

  • Effects of visual and cognitive interference on joint contributions in perturbed standing: a temporal and spectral analysis.

    abstract::Postural balance requires using joint strategies which may be changed from normal conditions by interfering with the sensory information. The goal of the present study was to quantitatively evaluate the role of the joint mechanisms during perturbed stance. Visual and cognitive interference was imposed to sixteen healt...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-017-0606-7

    authors: Ashtiani MN,Azghani MR

    更新日期:2018-03-01 00:00:00

  • An application of linear output error modelling for studying lymphocyte migration in peripheral lymphoid tissues.

    abstract::Lymphocyte recirculation between lymphatic and blood vessels and migration through tissues are essential mechanisms underlying immunological surveillance. However, the kinetics of lymphocyte migration through lymphoid tissues remains poorly understood. The present study of lymphocyte migration, based on a sheep model ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178774

    authors: Srikusalanukul W,De Bruyne F,McCullagh P

    更新日期:2002-09-01 00:00:00

  • Medical physics is alive and well and growing in South East Asia.

    abstract::In recent years there has been a significant economic growth in South East Asia, along with it a concurrent development of medical physics. The status of four countries--Malaysia, Thailand, the Philippines and Indonesia are presented. Medical physicists in these countries have been experiencing the usual problems of l...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Ng K,Pirabul R,Peralta A,Soejoko D

    更新日期:1997-03-01 00:00:00

  • Effect of computed tomography number-relative electron density conversion curve on the calculation of radiotherapy dose and evaluation of Monaco radiotherapy treatment planning system.

    abstract::The accuracy of a computed tomography (CT)-relative electron density (RED) curve may have an indirect impact on the accuracy of dose calculation by a treatment planning system (TPS). This effect has not been previously quantified for input of different CT-RED curves from different CT-scan units in the Monaco TPS. This...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-019-00745-6

    authors: Hasani M,Farhood B,Ghorbani M,Naderi H,Saadatmand S,Karimkhani Zandi S,Knaup C

    更新日期:2019-06-01 00:00:00

  • Comparison of 192Ir air kerma calibration coefficients derived at ARPANSA using the interpolation method and at the National Physical Laboratory using a direct measurement.

    abstract::The reference air kerma rate from 192Ir High Dose Rate (HDR) brachytherapy sources can be measured using a suitably calibrated Farmer chamber and an appropriate in-air calibration jig. When a primary standard for 192Ir gamma rays is available, a calibration coefficient for the chamber and jig combination can be determ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178603

    authors: Butler D,Haworth A,Sander T,Todd S

    更新日期:2008-12-01 00:00:00

  • A simulation study comparing nine mathematical models of arterial input function for dynamic contrast enhanced MRI to the Parker model.

    abstract::Due to large inter- and intra-patient variabilities of arterial input functions (AIFs), accurately modeling and using patient-specific AIF are very important for quantitative analysis of dynamic contrast enhanced MRI. Computer simulations were performed to evaluate and compare nine population AIF models with the Parke...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-018-0632-0

    authors: He D,Xu L,Qian W,Clarke J,Fan X

    更新日期:2018-06-01 00:00:00

  • Management and autopsy of a radioactive cadaver.

    abstract::A 69 year old male was treated with an ablative dose of 3.7 GBq (100 mCi) of I131 for carcinoma of the thyroid and died 10 days after administration. The requirement for an autopsy and the level of radiation still present in the body necessitated the intervention of Radiation Safety Personnel to minimise support staff...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Wallace AB,Bush V

    更新日期:1991-06-01 00:00:00

  • A Monte Carlo technique to establish the water/tissue equivalence of phantom materials.

    abstract::The quality of phantom materials is crucial for accurate dosimetry in radiotherapy. A wide range of factors such as density, electron density and elemental composition can influence the radiation properties, and hence the absorbed dose, of materials. New materials can be tested by direct measurements which requires co...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Keall P,Kron T,Hoban P

    更新日期:1993-09-01 00:00:00

  • Monte Carlo simulation of the RBE of I-131 radiation using DNA damage as biomarker.

    abstract::In general, a weighting factor of one is applied for low linear energy transfer radiations. However, several studies indicate that relative biological effectiveness (RBE) of low energy photons and electrons is greater than one. The aim of this current study was calculating the RBE of I-131 radiation relative to Co-60 ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-017-0544-4

    authors: Ezzati AO,Mahmoud-Pashazadeh A,Studenski MT

    更新日期:2017-06-01 00:00:00

  • Development of a method for manufacturing customized nasal mask cushion for CPAP therapy.

    abstract::A continuous positive airway pressure (CPAP) device is considered one of the most effective treatments for obstructive sleep apnea (OSA). However, many patients receiving this treatment complain of mask discomfort and other issues. Therefore, this study aimed to develop a customized nasal mask cushion to reduce the di...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0383-0

    authors: Hsu DY,Cheng YL,Bien MY,Lee HC

    更新日期:2015-12-01 00:00:00

  • Automated ventilator testing.

    abstract::A new era has arrived for the Biomedical Engineering Department at the Royal Women's Hospital in Melbourne. We have developed a system to qualitatively test for intermittent or unconfirmed faults, associated with Bear Cub ventilators. Where previous testing has been inadequate, computer logging is now used to interfac...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Ghaly J,Smith AL

    更新日期:1994-06-01 00:00:00

  • Field size consistency of nominally matched linacs.

    abstract::Given that there is increasing recognition of the effect that sub-millimetre changes in collimator position can have on radiotherapy beam dosimetry, this study aimed to evaluate the potential variability in small field collimation that may exist between otherwise matched linacs. Field sizes and field output factors we...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0349-2

    authors: Kairn T,Asena A,Charles PH,Hill B,Langton CM,Middlebrook ND,Moylan R,Trapp JV

    更新日期:2015-06-01 00:00:00

  • Shielding properties of fibre cement wallboard.

    abstract::Transmission data for a fibre cement wallboard (villaboard) are determined for use in diagnostic shielding designs. Villaboard is found to be more attenuating than plasterboard e.g. 9 mm of villaboard is equivalent to 16 mm of plasterboard. ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Thiele DL,Godwin GA,Coakley KS

    更新日期:1998-09-01 00:00:00

  • Physiologic outcome of varying speed rotary blood pump support algorithms: a review study.

    abstract::Rotary blood pumps have the potential to become a viable long-term treatment option for the heart failure patients to bridge to transplantation or destination therapy. However, these devices operate at a constant speed which may lead to long term complications or they may operate in an undesired support mode such as e...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,评审

    doi:10.1007/s13246-015-0405-y

    authors: Bozkurt S

    更新日期:2016-03-01 00:00:00

  • The clinical value of ophthalmic electrodiagnosis in children.

    abstract::A group of 113 children with poor vision who had been referred to the Electrodiagnostic Clinic over a five year period were investigated for disease of the retina and optic pathway by electroretinography (ERG), electro-oculography (EOG) and visual evoked response (VER). The electrodiagnostic measurements were made usi...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178360

    authors: Hidajat RR,Goode DH

    更新日期:2001-09-01 00:00:00

  • Investigating the impact of tumour motion on TomoTherapy stereotactic ablative body radiotherapy (SABR) deliveries on 3-dimensional and 4-dimensional computed tomography.

    abstract::TomoTherapy can provide highly accurate SABR deliveries, but currently it does not have any effective motion management techniques. Shallow breathing has been identified as one possible motion management solution on TomoTherapy, which has been made possible with the BreatheWell audiovisual biofeedback (AVB) device. Si...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-019-00727-8

    authors: Hu Y,Archibald-Heeren B,Byrne M,Cai E,Wang Y

    更新日期:2019-03-01 00:00:00

  • Response of air, silicon and dosimetric films to x-ray spectra of various qualities.

    abstract::Calculations have been performed of the kerma to radiographic film and to silicon from a number of x-ray spectra generated at 30 to 140 kV with tungsten and molybdenum targets. These results have been compared with the air-kerma values due to the same beams. It is concluded that both film and silicon can be used as pr...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Paix D

    更新日期:1992-12-01 00:00:00

  • Multi-layer cube sampling for liver boundary detection in PET-CT images.

    abstract::Liver metabolic information is considered as a crucial diagnostic marker for the diagnosis of fever of unknown origin, and liver recognition is the basis of automatic diagnosis of metabolic information extraction. However, the poor quality of PET and CT images is a challenge for information extraction and target recog...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-018-0650-y

    authors: Liu X,Yang J,Song S,Song H,Ai D,Zhu J,Jiang Y,Wang Y

    更新日期:2018-06-01 00:00:00

  • Singular value based characterization and analysis of thermal patches for early breast abnormality detection.

    abstract::The purpose of this study is to develop a novel breast abnormality detection system by utilizing the potential of infrared breast thermography (IBT) in early breast abnormality detection. Since the temperature distributions are different in normal and abnormal thermograms and hot thermal patches are visible in abnorma...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-018-0681-4

    authors: Gogoi UR,Bhowmik MK,Bhattacharjee D,Ghosh AK

    更新日期:2018-12-01 00:00:00

  • An assessment on the use of RadCalc to verify Raystation Electron Monte Carlo plans.

    abstract::Large differences in monitor units have been observed when RadCalc, a pencil-beam-algorithm based software, is used to verify clinical electron plans from Raystation, a Monte-Carlo-algorithm based planning system. To investigate the problem, a number of clinical plans as well as test plans were created and calculated ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-016-0470-x

    authors: Hu Y,Archibald-Heeren B,Byrne M,Wang Y

    更新日期:2016-09-01 00:00:00

  • Short tangential arcs in VMAT based breast and chest wall radiotherapy lead to conformity of the breast dose with lesser cardiac and lung doses: a prospective study of breast conservation and mastectomy patients.

    abstract::Volumetric modulated arc therapy (VMAT) is modern rotational intensity modulated therapy used for treatment of several sites. The study aimed to analyze partial tangential arc VMAT treatment planning and delivery, including analyzing the cardiac and contralateral breast doses resulting from this technique. A total of ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-017-0558-y

    authors: Munshi A,Sarkar B,Anbazhagan S,Giri UK,Kaur H,Jassal K,Ganesh T,Kalyan Mohanti B

    更新日期:2017-09-01 00:00:00

  • Light-weight lead aprons--light on weight, protection or labelling accuracy?

    abstract::X-ray transmission tests were performed on a Green-Lite (Infab Corporation) apron/vest combination, and compared to a number of other apron/vest combinations routinely used at Christchurch Hospital as well as a sheet of 0.5 mm lead. The materials were X-rayed using the primary beam of a Philips Optimus 50 X-ray machin...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178704

    authors: Muir S,McLeod R,Dove R

    更新日期:2005-06-01 00:00:00

  • Bicoherence analysis of quadriceps electromyogram during isometric knee extension.

    abstract::Bicoherence analysis is applied to electromyogram (EMG) data for the vastus lateralis quadriceps muscle of 18 adult male subjects for isometric knee extension exercise. Bicoherence spectra display ridge-like features that are indicative of deterministic chaotic behaviour and similar to those reported for normal electr...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1007/BF03178691

    authors: Simeoni RJ,Mills PM

    更新日期:2003-03-01 00:00:00

  • Automatic counting of nuclear tracks.

    abstract::Two software packages designed for automatic counting nuclear tracks are tested and compared. The image processing in the first package is divided into three parts segmentation, speckle elimination and removal of ill-formed track holes. The second package is also divided into three parts but the last part is modified ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Coakley K,Wong CF,Forbes K,Anh V

    更新日期:1992-06-01 00:00:00

  • Ultrasound shear wave simulation of wave propagation at oblique angles.

    abstract::Shear wave elasticity imaging (SWEI) has been used to measure the local tissue elasticity. The local tissue shear modulus can be reconstructed from the displacement field of shear waves using an algebraic Helmholtz inversion (AHI) equation or a time-of-flight (TOF)-based algorithm. The shear waves, which are generated...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-019-00748-3

    authors: Park DW,Cho HC

    更新日期:2019-09-01 00:00:00