Monte Carlo simulation of the RBE of I-131 radiation using DNA damage as biomarker.

Abstract:

:In general, a weighting factor of one is applied for low linear energy transfer radiations. However, several studies indicate that relative biological effectiveness (RBE) of low energy photons and electrons is greater than one. The aim of this current study was calculating the RBE of I-131 radiation relative to Co-60 gamma photons in 100 μm spheroid cells using Monte Carlo (MC) simulations. These calculations were compared to experimentally measured results. MCNPX2.6 was used to simulate the I-131 and Co-60 irradiation setups and calculate the secondary electron spectra at energies higher than 1 keV with varying oxygen concentrations. The electron spectra at energies lower than 1 keV were obtained by extrapolation (down to 10 eV). The calculated electron spectra were input into the MCDS micro-dosimetric Monte Carlo code to calculate the DSB induction and related RBE. The calculated RBE of I-131 radiation relative to Co-60 photons, as the reference radiation recommended by the International Commission on Radiation Protection (ICRP), was 1.06, 1.03 and 1.02 for oxygen concentrations of 0, 5 and 100%, respectively. Results of MC simulations indicate the RBE of I-131 is greater than one. This finding, despite a 10% discrepancy with the findings of the previous in vitro study of one of the authors of this paper, reemphasizes that I-131 radiation induces more severe biological damage than current ICRP recommendations.

authors

Ezzati AO,Mahmoud-Pashazadeh A,Studenski MT

doi

10.1007/s13246-017-0544-4

subject

Has Abstract

pub_date

2017-06-01 00:00:00

pages

395-400

issue

2

eissn

0158-9938

issn

1879-5447

pii

10.1007/s13246-017-0544-4

journal_volume

40

pub_type

杂志文章
  • A simple method to measure proton beam energy in a standard medical cyclotron.

    abstract::A simple and rapid technique to measure the proton beam energy in the external beam line of a medical cyclotron has been examined. A stack of 0.1 mm thick high purity copper (Cu) foils was bombarded and the relative activity of 65Zn produced in each foil was compared to a computational model that predicted activity, b...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178634

    authors: Burrage JW,Asad AH,Fox RA,Price RI,Campbell AM,Siddiqui S

    更新日期:2009-06-01 00:00:00

  • Diagnostic x-ray spectra simulation, verification and application to the clinical environment.

    abstract::A set of computer programs to simulate diagnostic x-ray spectra has been developed according to the method of Birch and Marshall, with good agreement to published HPA data. These programs have been extended to simulate spectra generated with capacitor discharge x-ray units. The application of these programs has proved...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: McLean D

    更新日期:1989-09-01 00:00:00

  • Simultaneous EEG-fMRI for working memory of the human brain.

    abstract::Memory plays an important role in human life. Memory can be divided into two categories, i.e., long term memory and short term memory (STM). STM or working memory (WM) stores information for a short span of time and it is used for information manipulations and fast response activities. WM is generally involved in the ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,评审

    doi:10.1007/s13246-016-0438-x

    authors: Ahmad RF,Malik AS,Kamel N,Reza F,Abdullah JM

    更新日期:2016-06-01 00:00:00

  • Comparison of natural and synthetic diamond X-ray detectors.

    abstract::Diamond detectors are particularly well suited for dosimetry applications in radiotherapy for reasons including near-tissue equivalence and high-spatial resolution resulting from small sensitive volumes. However, these detectors have not become commonplace due to high cost and poor availability arising from the need f...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-010-0040-6

    authors: Lansley SP,Betzel GT,Metcalfe P,Reinisch L,Meyer J

    更新日期:2010-12-01 00:00:00

  • A proton therapy system in Nagoya Proton Therapy Center.

    abstract::The purpose of this paper is to describe an outline of a proton therapy system in Nagoya Proton Therapy Center (NPTC). The NPTC has a synchrotron with a linac injector and three treatment rooms: two rooms are equipped with a gantry and the other one is equipped with a fixed horizontal beamline. One gantry treatment ro...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-016-0456-8

    authors: Toshito T,Omachi C,Kibe Y,Sugai H,Hayashi K,Shibata H,Yasui K,Tanaka K,Yamamoto T,Yoshida A,Nikawa E,Asai K,Shimomura A,Okumura I,Suzuki T,Kinou H,Isoyama S,Ogino H,Iwata H,Shibamoto Y,Mizoe J

    更新日期:2016-09-01 00:00:00

  • Recent developments in radiation therapy planning and treatment optimization.

    abstract::Radiation therapy of cancer is today going through a very dynamic development with the introduction of a large number of new treatment principles, new types of treatment units and new radiobiologically based optimization algorithms for treatment planning. All of these make use of the recent developments in three dimen...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,评审

    doi:

    authors: Brahme A

    更新日期:1996-06-01 00:00:00

  • Photon buildup in orthovoltage X-ray beams.

    abstract::Orthovoltage x-ray beams exhibit the characteristic of depth dose buildup which is not well described in the literature. The principal reason for this phenomenon is the increase in dose deposited due to electrons set in motion by secondary (Compton) scattered photons within the phantom, as depth is increased until lon...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Hill RF,Keall PJ,Beckham WA,Perez MD

    更新日期:1998-06-01 00:00:00

  • Neuro-muscular junction block stimulator simulator.

    abstract::Improved technology and higher fidelity are making medical simulations increasingly popular. A simulated peripheral nerve stimulator and thumb actuator has been developed for use with the SimMan Universal Patient Simulator. This device incorporates a handheld control box, a McKibben pneumatic muscle and articulated th...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Sprick C

    更新日期:2006-03-01 00:00:00

  • Evaluation of dose enhancement in presence of gold nanoparticles in eye brachytherapy by 103Pd source.

    abstract::In recent years, the use of gold nanoparticles in radiation therapy has been introduced as a new approach in radiotherapy. The aim of this study is to investigate the effect of gold nanoparticles (GNPs) in plaque brachytherapy for choroidal melanoma using Monte Carlo (MC) simulation. MCNPX code was used for simulation...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-017-0555-1

    authors: Rezaei H,Zabihzadeh M,Ghorbani M,Goli Ahmadabad F,Mostaghimi H

    更新日期:2017-09-01 00:00:00

  • Ozone, cloud, solar and UV-B levels at a low pollution, Southern Hemisphere, sub-tropical site for winter/spring 1995.

    abstract::This paper analyses daily ozone, cloud cover, solar radiation and broadband UV-B data for winter/spring at a low pollution Southern Hemispheric sub-tropical site (27.80 degrees S). The average ozone concentration for the period was 290 DU. An anti-correlation is presented between the ozone and UV-B data over a 5 day p...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Sabburg J,Parisi A,Wong J

    更新日期:1997-12-01 00:00:00

  • Reliability of the Cobb angle index derived by traditional and computer assisted methods.

    abstract::The reliability of the traditional Cobb angle index, which at present exhibits a wide range of reported values, was determined in this study and amounted to a within subject error of +/-4.3 degrees and a between subject error of +/-4.9 degrees. An attempt to pinpoint the source of this variability by investigating the...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Dutton KE,Jones TJ,Slinger BS,Scull ER,O'Connor J

    更新日期:1989-03-01 00:00:00

  • Characterization of a Fricke dosimeter at high energy photon and electron beams used in radiotherapy.

    abstract::The dosimetric features of the Fricke dosimeter in clinical linear accelerator beams are considered. Experimental data were obtained using various nominal energies 6 and 18 MV, 12 and 15 MeV, including the (60)Co γ-ray beam. The calibration of the dosimeters was performed using the ionization chamber as a reference do...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-011-0093-1

    authors: Moussous O,Khoudri S,Benguerba M

    更新日期:2011-12-01 00:00:00

  • Practical considerations for reporting surface dose in external beam radiotherapy: a 6 MV X-ray beam study.

    abstract::In this study, we assessed the accuracy of surface doses determined by direct measurement and treatment planning system (TPS) calculations, relative to benchmark Monte Carlo (MC) doses calculated at 70 μm for a 6 MV, 10 × 10 cm clinical radiotherapy beam. In a homogeneous phantom with both open and fixed wedged fields...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-012-0145-1

    authors: Kim JH,Hill R,Kuncic Z

    更新日期:2012-09-01 00:00:00

  • The use of round ended needles for high dose rate brachytherapy implants.

    abstract::The use of Speiser needles for interstitial implants has resulted in malfunctioning of HDR afterloading equipment due to seepage of blood. We have successfully used rounded ended needles in the patient after removal of the trocar ended needles, preventing the seepage of blood. This technique also helps to prevent any ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Das KR,Duchesne G,Coles JR,Pinder P

    更新日期:1999-12-01 00:00:00

  • A phantom for verification of dwell position and time of a high dose rate brachytherapy source.

    abstract::Accuracy of dwell position and reproducibility of dwell time are critical in high dose rate (HDR) brachytherapy. A phantom was designed to verify dwell position and dwell time reproducibility for an Ir-192 HDR stepping source using Computed Radiography (CR). The central part of the phantom, incorporating thin alternat...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-012-0138-0

    authors: Madebo M,Pillainayagam J,Kron T,Franich R

    更新日期:2012-09-01 00:00:00

  • A rapid compression technique for 4-D functional MRI images using data rearrangement and modified binary array techniques.

    abstract::Compression techniques are vital for efficient storage and fast transfer of medical image data. The existing compression techniques take significant amount of time for performing encoding and decoding and hence the purpose of compression is not fully satisfied. In this paper a rapid 4-D lossy compression method constr...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0385-y

    authors: Uma Vetri Selvi G,Nadarajan R

    更新日期:2015-12-01 00:00:00

  • Evaluation of useful neutron flux for accelerator boron neutron capture therapy using the 7Li(p,n) reaction.

    abstract::Accelerator neutron sources for epithermal neutron capture therapy utilising the 7Li(p,n) nuclear reaction are proposed to operate in the range of 1.88 to 2.5 MeV proton energy. Operation with proton energies closer to the reaction threshold decreases neutron yield but allows for smaller reflector and moderator, with ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Zimin S,Allen BJ

    更新日期:1998-12-01 00:00:00

  • EEG classification of adolescents with type I and type II of bipolar disorder.

    abstract::Bipolar disorder (BD) is a severe psychiatric disorder and has two common types: type I and type II. Early diagnosis of the subtypes is very challenging particularly in adolescence. In this study, 38 adolescents are participated including 18 patients with BD I and 20 patients with BD II. The electroencephalogram signa...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0375-0

    authors: Khaleghi A,Sheikhani A,Mohammadi MR,Nasrabadi AM,Vand SR,Zarafshan H,Moeini M

    更新日期:2015-12-01 00:00:00

  • Biomathematical modelling of physiological fluids using a Casson fluid with emphasis to peristalsis.

    abstract::In this paper, the peristaltic flow of rheologically complex physiological fluids when modelled by a non-Newtonian Casson fluid in a two-dimensional channel is considered. Of interest is the difference between peristaltic transport of Newtonian and non-Newtonian fluids. A perturbation series method of solution of the ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Mernone AV,Mazumdar JN

    更新日期:2000-09-01 00:00:00

  • Physiologic outcome of varying speed rotary blood pump support algorithms: a review study.

    abstract::Rotary blood pumps have the potential to become a viable long-term treatment option for the heart failure patients to bridge to transplantation or destination therapy. However, these devices operate at a constant speed which may lead to long term complications or they may operate in an undesired support mode such as e...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,评审

    doi:10.1007/s13246-015-0405-y

    authors: Bozkurt S

    更新日期:2016-03-01 00:00:00

  • Light-weight lead aprons--light on weight, protection or labelling accuracy?

    abstract::X-ray transmission tests were performed on a Green-Lite (Infab Corporation) apron/vest combination, and compared to a number of other apron/vest combinations routinely used at Christchurch Hospital as well as a sheet of 0.5 mm lead. The materials were X-rayed using the primary beam of a Philips Optimus 50 X-ray machin...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178704

    authors: Muir S,McLeod R,Dove R

    更新日期:2005-06-01 00:00:00

  • Using EGS4 Monte Carlo in medical radiation physics.

    abstract::Monte Carlo modelling of particle transport problems in medical radiation physics offers significant advantages over other techniques. Experiments can be performed without having to set up the physical situation, and "impossible" experiments can be performed, such as labelling multiple-scattered particles or simulatin...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type:

    doi:

    authors: Murray D

    更新日期:1990-09-01 00:00:00

  • Hidden pattern discovery on epileptic EEG with 1-D local binary patterns and epileptic seizures detection by grey relational analysis.

    abstract::This paper proposes a novel approach to detect epilepsy seizures by using Electroencephalography (EEG), which is one of the most common methods for the diagnosis of epilepsy, based on 1-Dimension Local Binary Pattern (1D-LBP) and grey relational analysis (GRA) methods. The main aim of this paper is to evaluate and val...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0362-5

    authors: Kaya Y

    更新日期:2015-09-01 00:00:00

  • The linear accelerator mechanical and radiation isocentre assessment with an electronic portal imaging device (EPID).

    abstract::Regular checks on the performance of radiotherapy treatment units are essential and a variety of protocols has been published. These protocols identify that the determination of isocentre must be accurate and unambiguous since both the localization of a radiation field on a patient and positioning aids are referenced ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178670

    authors: Liu G,van Doorn T,Bezak E

    更新日期:2004-09-01 00:00:00

  • Human brain wave activity during exposure to radiofrequency field emissions from mobile phones.

    abstract::The aim of this study was to determine whether there is an effect of mobile phone electromagnetic field emissions on the human electroencephalograph (EEG). EEG recordings from ten awake subjects were taken during exposure to radiofrequency (RF) emissions from a mobile phone positioned behind the head. Two experimental...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1007/BF03179176

    authors: D'Costa H,Trueman G,Tang L,Abdel-rahman U,Abdel-rahman W,Ong K,Cosic I

    更新日期:2003-12-01 00:00:00

  • Bicoherence analysis of quadriceps electromyogram during isometric knee extension.

    abstract::Bicoherence analysis is applied to electromyogram (EMG) data for the vastus lateralis quadriceps muscle of 18 adult male subjects for isometric knee extension exercise. Bicoherence spectra display ridge-like features that are indicative of deterministic chaotic behaviour and similar to those reported for normal electr...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1007/BF03178691

    authors: Simeoni RJ,Mills PM

    更新日期:2003-03-01 00:00:00

  • Comparison of 192Ir air kerma calibration coefficients derived at ARPANSA using the interpolation method and at the National Physical Laboratory using a direct measurement.

    abstract::The reference air kerma rate from 192Ir High Dose Rate (HDR) brachytherapy sources can be measured using a suitably calibrated Farmer chamber and an appropriate in-air calibration jig. When a primary standard for 192Ir gamma rays is available, a calibration coefficient for the chamber and jig combination can be determ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178603

    authors: Butler D,Haworth A,Sander T,Todd S

    更新日期:2008-12-01 00:00:00

  • A percolation-like model for simulating inter-cellular diffusion in the context of bystander signalling in tumour.

    abstract::Despite ongoing active research, the role of the radiation bystander effect in modifying local tissue response to an ionising radiation dose remains unclear. The present study aims to provide new insight by simulating the diffusion-mediated inter-cellular communication processes in 2D and 3D cell-like structures to ca...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-010-0048-y

    authors: Moulton CR,Fleming AJ,Ebert MA

    更新日期:2011-04-01 00:00:00

  • Effects of treatment distance and field size on build-up characteristics of Monte Carlo calculated absorbed dose for electron irradiation.

    abstract::Surface, build-up and depth dose characteristics of a monoenergetic electron point source simulated by Monte Carlo code MCNP4c for varying field size and SSD are extensively studied in this paper. MCNP4c (Monte Carlo N-Particle Transport Code System) has been extensively used in clinical dose simulation for its versat...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178652

    authors: Lin H,Wu DS,Wu AD

    更新日期:2004-12-01 00:00:00

  • Medical physics aspects of cancer care in the Asia Pacific region: 2014 survey results.

    abstract::It was the aim of this work to assess and track the workload, working conditions and professional recognition of radiation oncology medical physicists (ROMPs) in the Asia Pacific region over time. In this third survey since 2008, a structured questionnaire was mailed in 2014 to 22 senior medical physicists representin...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0373-2

    authors: Kron T,Azhari HA,Voon EO,Cheung KY,Ravindran P,Soejoko D,Inamura K,Han Y,Ung NM,TsedenIsh B,Win UM,Srivastava R,Marsh S,Farrukh S,Rodriguez L,Kuo M,Baggarley S,DilipKumara AH,Lee CC,Krisanachinda A,Nguyen XC,Ng

    更新日期:2015-09-01 00:00:00