Abstract:
:It was the aim of this work to assess and track the workload, working conditions and professional recognition of radiation oncology medical physicists (ROMPs) in the Asia Pacific region over time. In this third survey since 2008, a structured questionnaire was mailed in 2014 to 22 senior medical physicists representing 23 countries. As in previous surveys the questionnaire covered seven themes: 1 education, training and professional certification, 2 staffing, 3 typical tasks, 4 professional organisations, 5 resources, 6 research and teaching, and 7 job satisfaction. The response rate of 100% is a result of performing a survey through a network, which allows easy follow-up. The replies cover 4841 ROMPs in 23 countries. Compared to 2008, the number of medical physicists in many countries has doubled. However, the number of experienced ROMPs compared to the overall workforce is still small, especially in low and middle income countries. The increase in staff is matched by a similar increase in the number of treatment units over the years. Furthermore, the number of countries using complex techniques (IMRT, IGRT) or installing high end equipment (tomotherapy, robotic linear accelerators) is increasing. Overall, ROMPs still feel generally overworked and the professional recognition, while varying widely, appears to be improving only slightly. Radiation oncology medical physics practice has not changed significantly over the last 6 years in the Asia Pacific Region even if the number of physicists and the number and complexity of treatment techniques and technologies have increased dramatically.
journal_name
Australas Phys Eng Sci Medjournal_title
Australasian physical & engineering sciences in medicineauthors
Kron T,Azhari HA,Voon EO,Cheung KY,Ravindran P,Soejoko D,Inamura K,Han Y,Ung NM,TsedenIsh B,Win UM,Srivastava R,Marsh S,Farrukh S,Rodriguez L,Kuo M,Baggarley S,DilipKumara AH,Lee CC,Krisanachinda A,Nguyen XC,Ngdoi
10.1007/s13246-015-0373-2subject
Has Abstractpub_date
2015-09-01 00:00:00pages
493-501issue
3eissn
0158-9938issn
1879-5447pii
10.1007/s13246-015-0373-2journal_volume
38pub_type
杂志文章abstract::The Resonant Recognition Model (rrm) uses digital signal processing methods to investigate protein structure-function; and links the biological function of protein families to unique characteristic frequencies. The rrm originally used a single set of variables: the electron ion interaction potential (EIIP). Here the r...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1995-12-01 00:00:00
abstract::In recent years there has been a significant economic growth in South East Asia, along with it a concurrent development of medical physics. The status of four countries--Malaysia, Thailand, the Philippines and Indonesia are presented. Medical physicists in these countries have been experiencing the usual problems of l...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1997-03-01 00:00:00
abstract::This paper describes a software tool developed for research into the use of an electronic portal imaging device (EPID) to verify dose for intensity modulated radiation therapy (IMRT) beams. A portal dose image prediction (PDIP) model that predicts the EPID response to IMRT beams has been implemented into a commerciall...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/BF03179347
更新日期:2008-09-01 00:00:00
abstract::The assignment of pathogenicity to variants suspected of causing an inherited retinal disease and the subsequent creation of molecular genetic reports sent to clinical geneticists and ophthalmologists has traditionally been time-consuming and subject to error and ambiguity. The purpose of this paper is to describe a c...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-015-0420-z
更新日期:2016-03-01 00:00:00
abstract::Bipolar disorder (BD) is a severe psychiatric disorder and has two common types: type I and type II. Early diagnosis of the subtypes is very challenging particularly in adolescence. In this study, 38 adolescents are participated including 18 patients with BD I and 20 patients with BD II. The electroencephalogram signa...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-015-0375-0
更新日期:2015-12-01 00:00:00
abstract::The computed tomography (CT) imaging artefacts that metallic medical implants produce in surrounding tissues are usually contoured and over-ridden during radiotherapy treatment planning. In cases where radiotherapy treatment beams unavoidably pass though implants, it is especially important to understand the imaging a...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-013-0197-x
更新日期:2013-06-01 00:00:00
abstract::Most of the human head models used in dipole localisation research, which have been reported in the literature to date, assume a simplified cranial structure wherein the head is modelled as a set of distinct homogenous tissue compartments. The inherent inhomogeneity of the tissues has so far been ignored in these mode...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/BF03178283
更新日期:2001-03-01 00:00:00
abstract::AFOMP recognizes that clinical medical physicists should demonstrate that they are competent to practice their profession by obtaining appropriate education, training and supervised experience in the specialties of medical physics in which they practice, as well as having a basic knowledge of other specialties. To hel...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章,评审
doi:10.1007/s13246-011-0091-3
更新日期:2011-09-01 00:00:00
abstract::TomoTherapy can provide highly accurate SABR deliveries, but currently it does not have any effective motion management techniques. Shallow breathing has been identified as one possible motion management solution on TomoTherapy, which has been made possible with the BreatheWell audiovisual biofeedback (AVB) device. Si...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-019-00727-8
更新日期:2019-03-01 00:00:00
abstract::The angular distribution for electron beams produced by the Siemens KD-2 linear accelerator has been found by simulating electron transport through the scattering foils and air using two methods: Fermi-Eyges multiple Coulomb scattering calculations, and EGS4 Monte Carlo simulations. Fermi-Eyges theory gives solutions ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1994-09-01 00:00:00
abstract::Non-linear loading of the utilities supply introduced significant electromagnetic field (EMF) interference severe enough to disrupt electrocardiograph (ECG) monitoring and recordings in the new Emergency Department (ED) at the Royal Melbourne Hospital (RMH). This interference was evident even though standard Mu-metal ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/BF03178643
更新日期:2009-09-01 00:00:00
abstract::A new PTW advanced Markus ionization chamber has been implemented in IMRT fields, to measure surface dose at ICRU and ICRP reference depth of 0.07 mm [ICRU Report 39, Determination of dose equivalents resulting from external radiation sources, 1985; ICRP Publication 60, 1990 recommendations of the International Commis...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-010-0004-x
更新日期:2010-03-01 00:00:00
abstract::Surface, build-up and depth dose characteristics of a monoenergetic electron point source simulated by Monte Carlo code MCNP4c for varying field size and SSD are extensively studied in this paper. MCNP4c (Monte Carlo N-Particle Transport Code System) has been extensively used in clinical dose simulation for its versat...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/BF03178652
更新日期:2004-12-01 00:00:00
abstract::Post installation acceptance testing is vital to demonstrate that the equipment meets the vendor's specification and is suitable for clinical studies. The test procedures described in the NEMA NU 2-2001 document form the basis of vendor performance specifications of PET scanners and hence are also appropriate for acce...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-010-0016-6
更新日期:2010-06-01 00:00:00
abstract::Diamond detectors are particularly well suited for dosimetry applications in radiotherapy for reasons including near-tissue equivalence and high-spatial resolution resulting from small sensitive volumes. However, these detectors have not become commonplace due to high cost and poor availability arising from the need f...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-010-0040-6
更新日期:2010-12-01 00:00:00
abstract::Orthovoltage x-ray beams exhibit the characteristic of depth dose buildup which is not well described in the literature. The principal reason for this phenomenon is the increase in dose deposited due to electrons set in motion by secondary (Compton) scattered photons within the phantom, as depth is increased until lon...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1998-06-01 00:00:00
abstract::Currently, a software-based second check dose calculation for helical tomotherapy (HT) is not available. The goal of this study is to evaluate the dose calculation accuracy of the in-house software using EGS4/MCSIM Monte Carlo environment against the treatment planning system calculations. In-house software was used t...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-012-0165-x
更新日期:2012-12-01 00:00:00
abstract::This paper investigates the influence of inhomogeneous head tissue conductivity on EEGs. A head model with inhomogeneity of radial and tangential conductivity is built up. Based on this model the EEG signals are calculated using the finite elements method. The results show that the inhomogeneous radial and tangential ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/BF03178780
更新日期:2003-09-01 00:00:00
abstract::Transmission data for a fibre cement wallboard (villaboard) are determined for use in diagnostic shielding designs. Villaboard is found to be more attenuating than plasterboard e.g. 9 mm of villaboard is equivalent to 16 mm of plasterboard. ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1998-09-01 00:00:00
abstract::The knowledge of radiation dose at all points of interest within a patient's body is essential for the evaluation of treatment plans and for the judicious selection of the best one from among a set of competing plans. This paper discusses the physical and geometric aspects of radiation dose distribution calculations n...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1989-12-01 00:00:00
abstract::Thermoluminescence dosimetry (TLD) is a versatile tool for the assessment of dose from ionising radiation. The wide variety of TLD materials and their different physical forms allow the determination of different radiation qualities at dose levels from microGy to kGy. Major advantages of TL dosimeters are their small ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章,评审
doi:
更新日期:1994-12-01 00:00:00
abstract::Volumetric modulated arc therapy (VMAT) is modern rotational intensity modulated therapy used for treatment of several sites. The study aimed to analyze partial tangential arc VMAT treatment planning and delivery, including analyzing the cardiac and contralateral breast doses resulting from this technique. A total of ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-017-0558-y
更新日期:2017-09-01 00:00:00
abstract::This paper presents a new method to apply timing characteristics of electroencephalograph (EEG) beta frequency bands to assess the depth of anaesthesia (DoA). Firstly, the measured EEG signals are denoised and decomposed into 20 different frequency bands. The Mobility (M), permutation entropy (PE) and Lempel-Ziv compl...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-016-0459-5
更新日期:2016-09-01 00:00:00
abstract::Segmentation of different tissues is one of the initial and most critical tasks in different aspects of medical image processing. Manual segmentation of brain images resulted from magnetic resonance imaging is time consuming, so automatic image segmentation is widely used in this area. Ensemble based algorithms are ve...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-015-0352-7
更新日期:2015-06-01 00:00:00
abstract::Magnetic resonance imaging has become a key modality within the modern radiology department. In addition to the conventional slice images, three dimensional angiographic images, and quantitative flow measurements can be obtained. More recently methods have been developed which enable one to visualize the motion of obj...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章,评审
doi:
更新日期:1991-12-01 00:00:00
abstract::This study was aimed to improve the surgical accuracy of plating and screwing for complicated tibial plateau fracture assisted by 3D implants library and 3D-printed navigational template. Clinical cases were performed whereby complicated tibial plateau fractures were imaged using computed tomography and reconstructed ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-015-0330-0
更新日期:2015-03-01 00:00:00
abstract::The performance of an image registration (IR) software was evaluated for automatically detecting known errors simulated through the movement of ExactCouch using an onboard imager. Twenty-seven set-up errors (11 translations, 10 rotations, 6 translation and rotation) were simulated by introducing offset up to ± 15 mm i...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-012-0158-9
更新日期:2012-09-01 00:00:00
abstract::The aim of this study was to determine whether there is an effect of mobile phone electromagnetic field emissions on the human electroencephalograph (EEG). EEG recordings from ten awake subjects were taken during exposure to radiofrequency (RF) emissions from a mobile phone positioned behind the head. Two experimental...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1007/BF03179176
更新日期:2003-12-01 00:00:00
abstract::A set of computer programs to simulate diagnostic x-ray spectra has been developed according to the method of Birch and Marshall, with good agreement to published HPA data. These programs have been extended to simulate spectra generated with capacitor discharge x-ray units. The application of these programs has proved...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1989-09-01 00:00:00
abstract::X-ray imaging of the chest is challenging because of the large differences in x-ray attenuation between the mediastinal and lung regions of the chest. This large dynamic range of chest exit exposure, along with associated large changes in the scatter component of the beam, makes film based chest imaging difficult to o...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1993-12-01 00:00:00