Software tool for portal dosimetry research.

Abstract:

:This paper describes a software tool developed for research into the use of an electronic portal imaging device (EPID) to verify dose for intensity modulated radiation therapy (IMRT) beams. A portal dose image prediction (PDIP) model that predicts the EPID response to IMRT beams has been implemented into a commercially available treatment planning system (TPS). The software tool described in this work was developed to modify the TPS PDIP model by incorporating correction factors into the predicted EPID image to account for the difference in EPID response to open beam radiation and multileaf collimator (MLC) transmitted radiation. The processes performed by the software tool include; i) read the MLC file and the PDIP from the TPS, ii) calculate the fraction of beam-on time that each point in the IMRT beam is shielded by MLC leaves, iii) interpolate correction factors from look-up tables, iv) create a corrected PDIP image from the product of the original PDIP and the correction factors and write the corrected image to file, v) display, analyse, and export various image datasets. The software tool was developed using the Microsoft Visual Studio.NET framework with the C# compiler. The operation of the software tool was validated. This software provided useful tools for EPID dosimetry research, and it is being utilised and further developed in ongoing EPID dosimetry and IMRT dosimetry projects.

authors

Vial P,Hunt P,Greer PB,Oliver L,Baldock C

doi

10.1007/BF03179347

subject

Has Abstract

pub_date

2008-09-01 00:00:00

pages

216-22

issue

3

eissn

0158-9938

issn

1879-5447

journal_volume

31

pub_type

杂志文章
  • Supervised segmentation of MRI brain images using combination of multiple classifiers.

    abstract::Segmentation of different tissues is one of the initial and most critical tasks in different aspects of medical image processing. Manual segmentation of brain images resulted from magnetic resonance imaging is time consuming, so automatic image segmentation is widely used in this area. Ensemble based algorithms are ve...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0352-7

    authors: Ahmadvand A,Sharififar M,Daliri MR

    更新日期:2015-06-01 00:00:00

  • Verification dosimetry during treatment for helical tomotherapy using radiographic film.

    abstract::Helical tomotherapy (HT) is a novel radiotherapy treatment modality that allows the delivery of intensity modulated radiation in a rotational fashion. Due to the complexity of the treatment approach, it is desirable to have a simple tool for treatment delivery verification. Radiographic film placed under the patient i...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178723

    authors: Kron T,Yartsev S,Mackie TR

    更新日期:2005-12-01 00:00:00

  • Position paper: recommendations for a digital mammography quality assurance program V4.0.

    abstract::In 2001 the ACPSEM published a position paper on quality assurance in screen film mammography which was subsequently adopted as a basis for the quality assurance programs of both the Royal Australian and New Zealand College of Radiologists (RANZCR) and of BreastScreen Australia. Since then the clinical implementation ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-017-0583-x

    authors: Heggie JCP,Barnes P,Cartwright L,Diffey J,Tse J,Herley J,McLean ID,Thomson FJ,Grewal RK,Collins LT

    更新日期:2017-09-01 00:00:00

  • Proposing feature engineering method based on deep learning and K-NNs for ECG beat classification and arrhythmia detection.

    abstract::Arrhythmia is slow, fast or irregular heartbeat. Manual ECG assessment and disease classification is an error-prone task because of vast differences in ECG morphology and difficulty in accurate identifying ECG components. Moreover, proposing a computer-aided diagnosis system for heartbeat classification can be useful ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-019-00814-w

    authors: Khatibi T,Rabinezhadsadatmahaleh N

    更新日期:2019-11-26 00:00:00

  • Hidden pattern discovery on epileptic EEG with 1-D local binary patterns and epileptic seizures detection by grey relational analysis.

    abstract::This paper proposes a novel approach to detect epilepsy seizures by using Electroencephalography (EEG), which is one of the most common methods for the diagnosis of epilepsy, based on 1-Dimension Local Binary Pattern (1D-LBP) and grey relational analysis (GRA) methods. The main aim of this paper is to evaluate and val...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0362-5

    authors: Kaya Y

    更新日期:2015-09-01 00:00:00

  • Evaluation of Bremsstrahlung radiation dose in stereotactically radiocolloid therapy of cystic craniopharyngioma tumors with 32P radio-colloid.

    abstract::Over 90% of craniopharyngeal brain tumors are cystic, which enables the injection of beta emitters such as phosphorus-32 (32P) radio-colloid into cysts for their treatment. The aim of this study was to evaluate the clinical and theoretical modelling of Bremsstrahlung radiation dose resulting from stereotactic radio-co...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-018-0665-4

    authors: Babaei M,Ghahramani-Asl R,Sadoughi HR,Sardari D,Shahzadi S

    更新日期:2018-09-01 00:00:00

  • Biomathematical modelling of physiological fluids using a Casson fluid with emphasis to peristalsis.

    abstract::In this paper, the peristaltic flow of rheologically complex physiological fluids when modelled by a non-Newtonian Casson fluid in a two-dimensional channel is considered. Of interest is the difference between peristaltic transport of Newtonian and non-Newtonian fluids. A perturbation series method of solution of the ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Mernone AV,Mazumdar JN

    更新日期:2000-09-01 00:00:00

  • Field size consistency of nominally matched linacs.

    abstract::Given that there is increasing recognition of the effect that sub-millimetre changes in collimator position can have on radiotherapy beam dosimetry, this study aimed to evaluate the potential variability in small field collimation that may exist between otherwise matched linacs. Field sizes and field output factors we...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0349-2

    authors: Kairn T,Asena A,Charles PH,Hill B,Langton CM,Middlebrook ND,Moylan R,Trapp JV

    更新日期:2015-06-01 00:00:00

  • Fluid structure interaction (FSI) simulation of the left ventricle (LV) during the early filling wave (E-wave), diastasis and atrial contraction wave (A-wave).

    abstract::In this paper, the hemodynamic characteristics inside a physiologically correct three-dimensional LV model using fluid structure interaction scheme are examined under various heart beat conditions during early filling wave (E-wave), diastasis and atrial contraction wave (A-wave). The time dependent and incompressible ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-014-0250-4

    authors: Arefin MS,Morsi YS

    更新日期:2014-06-01 00:00:00

  • Polymer gel dosimeters with PVA-GA matrix.

    abstract::Properties of a new polymer gel with cross-linked polyvinyl alcohol as a gelatinous matrix were investigated. The new polymer gel dosimeter was named PVABAT. The irradiation was performed using a calibrated 60Co beam. The dose responses of the PVABAT formulations were quantified with MRI transverse relaxation rate (R2...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-017-0573-z

    authors: Abtahi SMM,Sadeghi Abandansari H

    更新日期:2017-09-01 00:00:00

  • Multi-layer cube sampling for liver boundary detection in PET-CT images.

    abstract::Liver metabolic information is considered as a crucial diagnostic marker for the diagnosis of fever of unknown origin, and liver recognition is the basis of automatic diagnosis of metabolic information extraction. However, the poor quality of PET and CT images is a challenge for information extraction and target recog...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-018-0650-y

    authors: Liu X,Yang J,Song S,Song H,Ai D,Zhu J,Jiang Y,Wang Y

    更新日期:2018-06-01 00:00:00

  • Investigating the differences of body mass index and waist circumference in the follow-up assessment of patients to cardiac rehabilitation with acute coronary syndrome.

    abstract::Obesity management is a key point during cardiac rehabilitation. The effect of new index, waist circumference (WC), in the obesity management of cardiac rehabilitation is not clear yet. Therefore, our study compared the WC index to the body mass index (BMI) in the evaluation of obesity management for the patients with...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1007/s13246-016-0471-9

    authors: Zhao H,Ma J,Zhou Q,Chen W,Zhu W,Cai Z,Lei H,Deng Y,Xu L,Qiu J

    更新日期:2016-12-01 00:00:00

  • A low cost ECG central station for intensive care.

    abstract::A electrocardiogram (ECG) central station has been developed for the Intensive Care Unit at Christchurch Hospital. The system allows the selection and display of four ECGs selected from seven bedside monitors in the Unit. It also provides for automatic display, hard copy and audio alarm of ECG from any monitor which h...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Jans R,Elder AG,Jones RD,Fright WR,Bones PJ

    更新日期:1990-03-01 00:00:00

  • Effective generation of the spread-out-Bragg peak from the laser accelerated proton beams using a carbon-proton mixed target.

    abstract::Conventional laser accelerated proton beam has broad energy spectra. It is not suitable for clinical use directly, so it is necessary for employing energy selection system. However, in the conventional laser accelerated proton system, the intensity of the proton beams in the low energy regime is higher than that in th...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-014-0292-7

    authors: Yoo SH,Cho I,Cho S,Song Y,Jung WG,Kim DH,Shin D,Lee SB,Pae KH,Park SY

    更新日期:2014-12-01 00:00:00

  • Influence of normalization and color features on super-pixel classification: application to cytological image segmentation.

    abstract::Super-pixel feature extraction is a key problem to get an acceptable performance in color super-pixel classification. Given a color feature extraction problem, it is necessary to know which is the best approach to solve this problem. In the current work, we're interested in the challenge of nucleus and cytoplasm autom...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-019-00735-8

    authors: Bechar MEA,Settouti N,Daho MEH,Adel M,Chikh MA

    更新日期:2019-06-01 00:00:00

  • The linear accelerator mechanical and radiation isocentre assessment with an electronic portal imaging device (EPID).

    abstract::Regular checks on the performance of radiotherapy treatment units are essential and a variety of protocols has been published. These protocols identify that the determination of isocentre must be accurate and unambiguous since both the localization of a radiation field on a patient and positioning aids are referenced ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178670

    authors: Liu G,van Doorn T,Bezak E

    更新日期:2004-09-01 00:00:00

  • Echocardiographic assessment of long-term hemodynamic characteristics of mechanical mitral valve prostheses with different mitral valvular diseases.

    abstract::Mitral stenosis (MS) and mitral insufficiency (MI) have different pre-operative hemodynamic characteristics. However, it is unclear if there are differences in long-term echocardiographic characteristics of MS and MI patients after mechanical mitral valve replacement. This study is to compare long-term echocardiograph...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-016-0521-3

    authors: Zhu X,Li Q,Tang H,Xiao X

    更新日期:2017-03-01 00:00:00

  • Complexity quantification of cardiac variability time series using improved sample entropy (I-SampEn).

    abstract::The sample entropy (SampEn) has been widely used to quantify the complexity of RR-interval time series. It is a fact that higher complexity, and hence, entropy is associated with the RR-interval time series of healthy subjects. But, SampEn suffers from the disadvantage that it assigns higher entropy to the randomized ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-016-0457-7

    authors: Marwaha P,Sunkaria RK

    更新日期:2016-09-01 00:00:00

  • A Monte Carlo technique to establish the water/tissue equivalence of phantom materials.

    abstract::The quality of phantom materials is crucial for accurate dosimetry in radiotherapy. A wide range of factors such as density, electron density and elemental composition can influence the radiation properties, and hence the absorbed dose, of materials. New materials can be tested by direct measurements which requires co...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Keall P,Kron T,Hoban P

    更新日期:1993-09-01 00:00:00

  • Estimation of Hounsfield unit conversion parameters for pelvic CT images.

    abstract::Linear scaling is used to convert raw computed tomography (CT) pixel values into Hounsfield units corresponding to different tissue values. Analysis of a benchmarking study, presented here, where the same CT scan was imported into and then exported from multiple radiotherapy treatment planning systems, found inconsist...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-018-0651-x

    authors: Kennedy A,Dowling J,Greer PB,Ebert MA

    更新日期:2018-09-01 00:00:00

  • The angular and energy distribution of the primary electron beam.

    abstract::The angular distribution for electron beams produced by the Siemens KD-2 linear accelerator has been found by simulating electron transport through the scattering foils and air using two methods: Fermi-Eyges multiple Coulomb scattering calculations, and EGS4 Monte Carlo simulations. Fermi-Eyges theory gives solutions ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Keall PJ,Hoban PW

    更新日期:1994-09-01 00:00:00

  • Image quality improvement for medium and large field of view Elekta XVI scans.

    abstract::Cone-beam computed tomography (CBCT) has become the standard imaging technique for many sites treated with Radiotherapy. The Elekta X-ray Volumetric Imaging (XVI) system allows for the acquisition of CBCTs with three different diameters; small (27 cm), medium (41 cm) and large (50 cm) (Elekta in XVI Corrective Mainten...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-019-00817-7

    authors: Little DP

    更新日期:2019-12-01 00:00:00

  • Intensity modulated radiation therapy (IMRT) surface dose measurements using a PTW advanced Markus chamber.

    abstract::A new PTW advanced Markus ionization chamber has been implemented in IMRT fields, to measure surface dose at ICRU and ICRP reference depth of 0.07 mm [ICRU Report 39, Determination of dose equivalents resulting from external radiation sources, 1985; ICRP Publication 60, 1990 recommendations of the International Commis...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-010-0004-x

    authors: Chen FQ,Gupta R,Metcalfe P

    更新日期:2010-03-01 00:00:00

  • Development of a biological signal-based evaluator for robot-assisted upper-limb rehabilitation: a pilot study.

    abstract::Bio-signal based assessment for upper-limb functions is an attractive technology for rehabilitation. In this work, an upper-limb function evaluator is developed based on biological signals, which could be used for selecting different robotic training protocols. Interaction force (IF) and participation level (PL, proce...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-019-00783-0

    authors: Sheng B,Tang L,Moosman OM,Deng C,Xie S,Zhang Y

    更新日期:2019-09-01 00:00:00

  • Recent developments in radiation therapy planning and treatment optimization.

    abstract::Radiation therapy of cancer is today going through a very dynamic development with the introduction of a large number of new treatment principles, new types of treatment units and new radiobiologically based optimization algorithms for treatment planning. All of these make use of the recent developments in three dimen...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,评审

    doi:

    authors: Brahme A

    更新日期:1996-06-01 00:00:00

  • Monte Carlo simulation of the RBE of I-131 radiation using DNA damage as biomarker.

    abstract::In general, a weighting factor of one is applied for low linear energy transfer radiations. However, several studies indicate that relative biological effectiveness (RBE) of low energy photons and electrons is greater than one. The aim of this current study was calculating the RBE of I-131 radiation relative to Co-60 ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-017-0544-4

    authors: Ezzati AO,Mahmoud-Pashazadeh A,Studenski MT

    更新日期:2017-06-01 00:00:00

  • Using EGS4 Monte Carlo in medical radiation physics.

    abstract::Monte Carlo modelling of particle transport problems in medical radiation physics offers significant advantages over other techniques. Experiments can be performed without having to set up the physical situation, and "impossible" experiments can be performed, such as labelling multiple-scattered particles or simulatin...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type:

    doi:

    authors: Murray D

    更新日期:1990-09-01 00:00:00

  • ACPSEM ROSG Oncology-PACS and OIS working group recommendations for quality assurance.

    abstract::The Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) Radiation Oncology Specialty Group (ROSG) formed a series of working groups in 2011 to develop position papers for guidance of radiation oncology medical physics practice within the Australasian setting. These position papers are intend...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-013-0238-5

    authors: Shakeshaft J,Perez M,Tremethick L,Ceylan A,Bailey M

    更新日期:2014-03-01 00:00:00

  • The impact of inhomogeneous tissue anisotropy on potential distribution within head model.

    abstract::This paper investigates the influence of inhomogeneous head tissue conductivity on EEGs. A head model with inhomogeneity of radial and tangential conductivity is built up. Based on this model the EEG signals are calculated using the finite elements method. The results show that the inhomogeneous radial and tangential ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178780

    authors: Wen P

    更新日期:2003-09-01 00:00:00

  • Computer-aided diagnosis system for classifying benign and malignant thyroid nodules in multi-stained FNAB cytological images.

    abstract::An automated computer-aided diagnosis system is developed to classify benign and malignant thyroid nodules using multi-stained fine needle aspiration biopsy (FNAB) cytological images. In the first phase, the image segmentation is performed to remove the background staining information and retain the appropriate foregr...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-013-0199-8

    authors: Gopinath B,Shanthi N

    更新日期:2013-06-01 00:00:00