Computer-aided diagnosis system for classifying benign and malignant thyroid nodules in multi-stained FNAB cytological images.

Abstract:

:An automated computer-aided diagnosis system is developed to classify benign and malignant thyroid nodules using multi-stained fine needle aspiration biopsy (FNAB) cytological images. In the first phase, the image segmentation is performed to remove the background staining information and retain the appropriate foreground cell objects in cytological images using mathematical morphology and watershed transform segmentation methods. Subsequently, statistical features are extracted using two-level discrete wavelet transform (DWT) decomposition, gray level co-occurrence matrix (GLCM) and Gabor filter based methods. The classifiers k-nearest neighbor (k-NN), Elman neural network (ENN) and support vector machine (SVM) are tested for classifying benign and malignant thyroid nodules. The combination of watershed segmentation, GLCM features and k-NN classifier results a lowest diagnostic accuracy of 60 %. The highest diagnostic accuracy of 93.33 % is achieved by ENN classifier trained with the statistical features extracted by Gabor filter bank from the images segmented by morphology and watershed transform segmentation methods. It is also observed that SVM classifier results its highest diagnostic accuracy of 90 % for DWT and Gabor filter based features along with morphology and watershed transform segmentation methods. The experimental results suggest that the developed system with multi-stained thyroid FNAB images would be useful for identifying thyroid cancer irrespective of staining protocol used.

authors

Gopinath B,Shanthi N

doi

10.1007/s13246-013-0199-8

subject

Has Abstract

pub_date

2013-06-01 00:00:00

pages

219-30

issue

2

eissn

0158-9938

issn

1879-5447

journal_volume

36

pub_type

杂志文章
  • Multi-layer cube sampling for liver boundary detection in PET-CT images.

    abstract::Liver metabolic information is considered as a crucial diagnostic marker for the diagnosis of fever of unknown origin, and liver recognition is the basis of automatic diagnosis of metabolic information extraction. However, the poor quality of PET and CT images is a challenge for information extraction and target recog...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-018-0650-y

    authors: Liu X,Yang J,Song S,Song H,Ai D,Zhu J,Jiang Y,Wang Y

    更新日期:2018-06-01 00:00:00

  • Monte Carlo simulation of the RBE of I-131 radiation using DNA damage as biomarker.

    abstract::In general, a weighting factor of one is applied for low linear energy transfer radiations. However, several studies indicate that relative biological effectiveness (RBE) of low energy photons and electrons is greater than one. The aim of this current study was calculating the RBE of I-131 radiation relative to Co-60 ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-017-0544-4

    authors: Ezzati AO,Mahmoud-Pashazadeh A,Studenski MT

    更新日期:2017-06-01 00:00:00

  • Evaluation of EBT radiochromic film using a multiple exposure technique.

    abstract::Radiochromic film is a self developing two-dimensional dosimeter system that is widely used in radiotherapy. Since its development some 40 years ago many improvements have been made; however the sensitivity can vary across the film and a non-linear dose response remains. The former can be addressed using a double expo...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-011-0067-3

    authors: Roozen K,Kron T,Haworth A,Franich R

    更新日期:2011-06-01 00:00:00

  • ACPSEM ROSG Oncology-PACS and OIS working group recommendations for quality assurance.

    abstract::The Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) Radiation Oncology Specialty Group (ROSG) formed a series of working groups in 2011 to develop position papers for guidance of radiation oncology medical physics practice within the Australasian setting. These position papers are intend...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-013-0238-5

    authors: Shakeshaft J,Perez M,Tremethick L,Ceylan A,Bailey M

    更新日期:2014-03-01 00:00:00

  • Computer model to optimise contrast in chest radiography.

    abstract::X-ray imaging of the chest is challenging because of the large differences in x-ray attenuation between the mediastinal and lung regions of the chest. This large dynamic range of chest exit exposure, along with associated large changes in the scatter component of the beam, makes film based chest imaging difficult to o...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: McLean D

    更新日期:1993-12-01 00:00:00

  • ECG interference suppressed using a harmonic generator.

    abstract::Non-linear loading of the utilities supply introduced significant electromagnetic field (EMF) interference severe enough to disrupt electrocardiograph (ECG) monitoring and recordings in the new Emergency Department (ED) at the Royal Melbourne Hospital (RMH). This interference was evident even though standard Mu-metal ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178643

    authors: Davie WJ,Fowler MJ,Koumoundouros E

    更新日期:2009-09-01 00:00:00

  • Response of air, silicon and dosimetric films to x-ray spectra of various qualities.

    abstract::Calculations have been performed of the kerma to radiographic film and to silicon from a number of x-ray spectra generated at 30 to 140 kV with tungsten and molybdenum targets. These results have been compared with the air-kerma values due to the same beams. It is concluded that both film and silicon can be used as pr...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Paix D

    更新日期:1992-12-01 00:00:00

  • Practical considerations for reporting surface dose in external beam radiotherapy: a 6 MV X-ray beam study.

    abstract::In this study, we assessed the accuracy of surface doses determined by direct measurement and treatment planning system (TPS) calculations, relative to benchmark Monte Carlo (MC) doses calculated at 70 μm for a 6 MV, 10 × 10 cm clinical radiotherapy beam. In a homogeneous phantom with both open and fixed wedged fields...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-012-0145-1

    authors: Kim JH,Hill R,Kuncic Z

    更新日期:2012-09-01 00:00:00

  • A novel ultrasound based approach for lesion segmentation and its applications in gynecological laparoscopic surgery.

    abstract::Laparoscopic ultrasound (LUS) has been widely utilized as a surgical aide in general, urological, and gynecological applications. Our study summarizes the clinical applications of laparoscopic ultrasonography in laparoscopic gynecologic surgery. Retrospective analyses were performed on 42 women subjects using laparosc...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0363-4

    authors: Gong XH,Lu J,Liu J,Deng YY,Liu WZ,Huang X,Pirbhulal S,Yu ZY,Wu WQ

    更新日期:2015-12-01 00:00:00

  • Supervised segmentation of MRI brain images using combination of multiple classifiers.

    abstract::Segmentation of different tissues is one of the initial and most critical tasks in different aspects of medical image processing. Manual segmentation of brain images resulted from magnetic resonance imaging is time consuming, so automatic image segmentation is widely used in this area. Ensemble based algorithms are ve...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0352-7

    authors: Ahmadvand A,Sharififar M,Daliri MR

    更新日期:2015-06-01 00:00:00

  • Extended Kalman smoother with differential evolution technique for denoising of ECG signal.

    abstract::Electrocardiogram (ECG) signal gives a lot of information on the physiology of heart. In reality, noise from various sources interfere with the ECG signal. To get the correct information on physiology of the heart, noise cancellation of the ECG signal is required. In this paper, the effectiveness of extended Kalman sm...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-016-0468-4

    authors: Panigrahy D,Sahu PK

    更新日期:2016-09-01 00:00:00

  • Evaluation of effective energy for QA and QC: measurement of half-value layer using radiochromic film density.

    abstract::The effective energy of diagnostic X-rays is important for quality assurance (QA) and quality control (QC). However, the half-value layer (HVL), which is necessary to evaluate the effective energy, is not ubiquitously monitored because ionization-chamber dosimetry is time-consuming and complicated. To verify the appli...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178625

    authors: Gotanda T,Katsuda T,Gotanda R,Tabuchi A,Yamamoto K,Kuwano T,Yatake H,Takeda Y

    更新日期:2009-03-01 00:00:00

  • Instruments to assess and measure personal and environmental radiofrequency-electromagnetic field exposures.

    abstract::Radiofrequency-electromagnetic field (RF-EMF) exposure of human populations is increasing due to the widespread use of mobile phones and other telecommunication and broadcasting technologies. There are ongoing concerns about potential short- and long-term public health consequences from RF-EMF exposures. To elucidate ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,评审

    doi:10.1007/s13246-015-0412-z

    authors: Bhatt CR,Redmayne M,Abramson MJ,Benke G

    更新日期:2016-03-01 00:00:00

  • Potential radiotherapy improvements with respiratory gating.

    abstract::Gating is a relatively new and potentially useful therapeutic addition to external beam radiotherapy applied to regions affected by intra-fraction motion. The impact was of gating on treatment margins, image artifacts, and volume and positional accuracy was investigated by CT imaging of sinusoidally moving spheres. Th...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178368

    authors: Keall PJ,Kini VR,Vedam SS,Mohan R

    更新日期:2002-03-01 00:00:00

  • Ultrasound shear wave simulation of wave propagation at oblique angles.

    abstract::Shear wave elasticity imaging (SWEI) has been used to measure the local tissue elasticity. The local tissue shear modulus can be reconstructed from the displacement field of shear waves using an algebraic Helmholtz inversion (AHI) equation or a time-of-flight (TOF)-based algorithm. The shear waves, which are generated...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-019-00748-3

    authors: Park DW,Cho HC

    更新日期:2019-09-01 00:00:00

  • Detection of left ventricle systolic dysfunction from shape deformity.

    abstract::Coronary artery disease producing ischemic cardiomyopathy is the most frequent cause of left ventricular systolic dysfunction. Non-ischemic cardiomyopathies can also produce systolic dysfunction; they may be inherited as genetic disorders or occur sporadically. These coronary injuries have repercussions on the left ve...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178864

    authors: Manivannan J,Reddy MR,Thanikachalam S,Kumar RA

    更新日期:2005-03-01 00:00:00

  • Performance of independent dose calculation in helical tomotherapy: implementation of the MCSIM code.

    abstract::Currently, a software-based second check dose calculation for helical tomotherapy (HT) is not available. The goal of this study is to evaluate the dose calculation accuracy of the in-house software using EGS4/MCSIM Monte Carlo environment against the treatment planning system calculations. In-house software was used t...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-012-0165-x

    authors: Dzintars E,Stathakis S,Mavroidis P,Sadeghi A,Papanikolaou N

    更新日期:2012-12-01 00:00:00

  • A Monte Carlo technique to establish the water/tissue equivalence of phantom materials.

    abstract::The quality of phantom materials is crucial for accurate dosimetry in radiotherapy. A wide range of factors such as density, electron density and elemental composition can influence the radiation properties, and hence the absorbed dose, of materials. New materials can be tested by direct measurements which requires co...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Keall P,Kron T,Hoban P

    更新日期:1993-09-01 00:00:00

  • Proposing feature engineering method based on deep learning and K-NNs for ECG beat classification and arrhythmia detection.

    abstract::Arrhythmia is slow, fast or irregular heartbeat. Manual ECG assessment and disease classification is an error-prone task because of vast differences in ECG morphology and difficulty in accurate identifying ECG components. Moreover, proposing a computer-aided diagnosis system for heartbeat classification can be useful ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-019-00814-w

    authors: Khatibi T,Rabinezhadsadatmahaleh N

    更新日期:2019-11-26 00:00:00

  • A proton therapy system in Nagoya Proton Therapy Center.

    abstract::The purpose of this paper is to describe an outline of a proton therapy system in Nagoya Proton Therapy Center (NPTC). The NPTC has a synchrotron with a linac injector and three treatment rooms: two rooms are equipped with a gantry and the other one is equipped with a fixed horizontal beamline. One gantry treatment ro...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-016-0456-8

    authors: Toshito T,Omachi C,Kibe Y,Sugai H,Hayashi K,Shibata H,Yasui K,Tanaka K,Yamamoto T,Yoshida A,Nikawa E,Asai K,Shimomura A,Okumura I,Suzuki T,Kinou H,Isoyama S,Ogino H,Iwata H,Shibamoto Y,Mizoe J

    更新日期:2016-09-01 00:00:00

  • The impact of smart metal artefact reduction algorithm for use in radiotherapy treatment planning.

    abstract::The presence of metal artefacts in computed tomography (CT) create issues in radiation oncology. The loss of anatomical information and incorrect Hounsfield unit (HU) values produce inaccuracies in dose calculations, providing suboptimal patient treatment. Metal artefact reduction (MAR) algorithms were developed to co...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-017-0543-5

    authors: Guilfoile C,Rampant P,House M

    更新日期:2017-06-01 00:00:00

  • The appearance and effects of metallic implants in CT images.

    abstract::The computed tomography (CT) imaging artefacts that metallic medical implants produce in surrounding tissues are usually contoured and over-ridden during radiotherapy treatment planning. In cases where radiotherapy treatment beams unavoidably pass though implants, it is especially important to understand the imaging a...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-013-0197-x

    authors: Kairn T,Crowe SB,Fogg P,Trapp JV

    更新日期:2013-06-01 00:00:00

  • A low cost ECG central station for intensive care.

    abstract::A electrocardiogram (ECG) central station has been developed for the Intensive Care Unit at Christchurch Hospital. The system allows the selection and display of four ECGs selected from seven bedside monitors in the Unit. It also provides for automatic display, hard copy and audio alarm of ECG from any monitor which h...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Jans R,Elder AG,Jones RD,Fright WR,Bones PJ

    更新日期:1990-03-01 00:00:00

  • Effect of postural changes on normal and stenosed common carotid artery using FSI.

    abstract::Gravity associated with postural changes has a strong bearing on haemodynamics of blood flow in arteries. Its effect on stenosed cases has not been widely investigated. In the present study, variation observed in blood flow during postural changes is investigated for different conditions like standing, sleeping and he...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-014-0246-0

    authors: Raghuvir Pai B,Ayachit A,Abdul Khader SM,Ahmed KA,Rao VR,Kamath SG,Gupta PD

    更新日期:2014-03-01 00:00:00

  • Shielding properties of fibre cement wallboard.

    abstract::Transmission data for a fibre cement wallboard (villaboard) are determined for use in diagnostic shielding designs. Villaboard is found to be more attenuating than plasterboard e.g. 9 mm of villaboard is equivalent to 16 mm of plasterboard. ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Thiele DL,Godwin GA,Coakley KS

    更新日期:1998-09-01 00:00:00

  • Investigating the impact of tumour motion on TomoTherapy stereotactic ablative body radiotherapy (SABR) deliveries on 3-dimensional and 4-dimensional computed tomography.

    abstract::TomoTherapy can provide highly accurate SABR deliveries, but currently it does not have any effective motion management techniques. Shallow breathing has been identified as one possible motion management solution on TomoTherapy, which has been made possible with the BreatheWell audiovisual biofeedback (AVB) device. Si...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-019-00727-8

    authors: Hu Y,Archibald-Heeren B,Byrne M,Cai E,Wang Y

    更新日期:2019-03-01 00:00:00

  • Comparison of skin dose between conventional radiotherapy and IMRT.

    abstract::The purpose of this study was to measure skin dose using radiochromic film for two step-and-shoot IMRT fields and compare the results to the skin dose for a conventional open field. All exposures were made using a 6 MV photon beam produced by a Varian 21EX linear accelerator (Varian Medical Systems, CA, USA) equipped ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178577

    authors: Price S,Williams M,Butson M,Metcalfe P

    更新日期:2006-09-01 00:00:00

  • Indices from lagged poincare plots of heart rate variability: an efficient nonlinear tool for emotion discrimination.

    abstract::Interest in human emotion recognition, regarding physiological signals, has recently risen. In this study, an efficient emotion recognition system, based on geometrical analysis of autonomic nervous system signals, is presented. The electrocardiogram recordings of 47 college students were obtained during rest conditio...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-017-0530-x

    authors: Goshvarpour A,Abbasi A,Goshvarpour A

    更新日期:2017-06-01 00:00:00

  • Evaluation of useful neutron flux for accelerator boron neutron capture therapy using the 7Li(p,n) reaction.

    abstract::Accelerator neutron sources for epithermal neutron capture therapy utilising the 7Li(p,n) nuclear reaction are proposed to operate in the range of 1.88 to 2.5 MeV proton energy. Operation with proton energies closer to the reaction threshold decreases neutron yield but allows for smaller reflector and moderator, with ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Zimin S,Allen BJ

    更新日期:1998-12-01 00:00:00

  • Comparison of 192Ir air kerma calibration coefficients derived at ARPANSA using the interpolation method and at the National Physical Laboratory using a direct measurement.

    abstract::The reference air kerma rate from 192Ir High Dose Rate (HDR) brachytherapy sources can be measured using a suitably calibrated Farmer chamber and an appropriate in-air calibration jig. When a primary standard for 192Ir gamma rays is available, a calibration coefficient for the chamber and jig combination can be determ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178603

    authors: Butler D,Haworth A,Sander T,Todd S

    更新日期:2008-12-01 00:00:00