Comparison of skin dose between conventional radiotherapy and IMRT.

Abstract:

:The purpose of this study was to measure skin dose using radiochromic film for two step-and-shoot IMRT fields and compare the results to the skin dose for a conventional open field. All exposures were made using a 6 MV photon beam produced by a Varian 21EX linear accelerator (Varian Medical Systems, CA, USA) equipped with a Millennium 120 leaf MLC. Three different field configurations were used, these were an open field, a step-and-shoot IMRT field and a clinical IMRT field. The mean ratio of the skin dose to dose at d(max) for an open 10 x 10 cm2 field at 100 cm SSD was 0.178 +/- 0.003. The step-and-shoot IMRT field consisted of 1 cm wide strips of decreasing intensity that were delivered using a step-and-shoot technique across a 10 x 10 cm2 field. The ratio of skin dose to dose at d(max) ranged from 0.180 to 0.257, with the low intensity steps having a higher relative skin dose compared to the high intensity steps. A model was derived that attributed these variations to the electron contamination from both the adjacent and more distant high intensity steps. The clinical field consisted of a 25 segment 9.8 x 10.0 cm2 beam arrangement. The ratio of skin dose to dose at d(max) for the clinical IMRT field ranged from 0.093 to 0.284. The results indicated that an IMRT field produced only minor changes in the relative skin dose, with variations potentially attributable to fluctuations in the electron contamination produced by neighbouring regions of different intensity. The use of an individual IMRT field does not significantly increase the skin dose above that of a conventional photon field.

authors

Price S,Williams M,Butson M,Metcalfe P

doi

10.1007/BF03178577

subject

Has Abstract

pub_date

2006-09-01 00:00:00

pages

272-7

issue

3

eissn

0158-9938

issn

1879-5447

journal_volume

29

pub_type

杂志文章
  • Thermoluminescence dosimetry and its applications in medicine--Part 1: Physics, materials and equipment.

    abstract::Thermoluminescence dosimetry (TLD) is a versatile tool for the assessment of dose from ionising radiation. The wide variety of TLD materials and their different physical forms allow the determination of different radiation qualities at dose levels from microGy to kGy. Major advantages of TL dosimeters are their small ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,评审

    doi:

    authors: Kron T

    更新日期:1994-12-01 00:00:00

  • Evaluation of Bremsstrahlung radiation dose in stereotactically radiocolloid therapy of cystic craniopharyngioma tumors with 32P radio-colloid.

    abstract::Over 90% of craniopharyngeal brain tumors are cystic, which enables the injection of beta emitters such as phosphorus-32 (32P) radio-colloid into cysts for their treatment. The aim of this study was to evaluate the clinical and theoretical modelling of Bremsstrahlung radiation dose resulting from stereotactic radio-co...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-018-0665-4

    authors: Babaei M,Ghahramani-Asl R,Sadoughi HR,Sardari D,Shahzadi S

    更新日期:2018-09-01 00:00:00

  • Technical developments in radiology in Australasia dating from 1977.

    abstract::This article outlines the enormous technological advances that have taken place in the practice of radiology in Australasia in the 30 years since approximately 1977. These developments have led to significant improvements in image quality across all modalities, including even general radiography, which had as its gene...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,评审

    doi:10.1007/BF03178423

    authors: Heggie JC

    更新日期:2007-09-01 00:00:00

  • Ozone, cloud, solar and UV-B levels at a low pollution, Southern Hemisphere, sub-tropical site for winter/spring 1995.

    abstract::This paper analyses daily ozone, cloud cover, solar radiation and broadband UV-B data for winter/spring at a low pollution Southern Hemispheric sub-tropical site (27.80 degrees S). The average ozone concentration for the period was 290 DU. An anti-correlation is presented between the ozone and UV-B data over a 5 day p...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Sabburg J,Parisi A,Wong J

    更新日期:1997-12-01 00:00:00

  • ACPSEM ROSG Oncology-PACS and OIS working group recommendations for quality assurance.

    abstract::The Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) Radiation Oncology Specialty Group (ROSG) formed a series of working groups in 2011 to develop position papers for guidance of radiation oncology medical physics practice within the Australasian setting. These position papers are intend...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-013-0238-5

    authors: Shakeshaft J,Perez M,Tremethick L,Ceylan A,Bailey M

    更新日期:2014-03-01 00:00:00

  • A novel ultrasound based approach for lesion segmentation and its applications in gynecological laparoscopic surgery.

    abstract::Laparoscopic ultrasound (LUS) has been widely utilized as a surgical aide in general, urological, and gynecological applications. Our study summarizes the clinical applications of laparoscopic ultrasonography in laparoscopic gynecologic surgery. Retrospective analyses were performed on 42 women subjects using laparosc...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0363-4

    authors: Gong XH,Lu J,Liu J,Deng YY,Liu WZ,Huang X,Pirbhulal S,Yu ZY,Wu WQ

    更新日期:2015-12-01 00:00:00

  • CT screening--whole-body and targeted.

    abstract::At present, the Australasian College of Physical Scientists and Engineers in Medicine does not support the practice of self-referred whole-body CT screening of asymptomatic patients because: The procedure involves a non-trivial radiation dose, which assumes even greater significance in the context of an ongoing screen...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 指南,杂志文章

    doi:10.1007/BF03178880

    authors: Le Heron JC,Coakley KS

    更新日期:2004-03-01 00:00:00

  • Comparison study of different head model structures with homogeneous/inhomogeneous conductivity.

    abstract::Most of the human head models used in dipole localisation research, which have been reported in the literature to date, assume a simplified cranial structure wherein the head is modelled as a set of distinct homogenous tissue compartments. The inherent inhomogeneity of the tissues has so far been ignored in these mode...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178283

    authors: Wen P,Li Y

    更新日期:2001-03-01 00:00:00

  • Verification dosimetry during treatment for helical tomotherapy using radiographic film.

    abstract::Helical tomotherapy (HT) is a novel radiotherapy treatment modality that allows the delivery of intensity modulated radiation in a rotational fashion. Due to the complexity of the treatment approach, it is desirable to have a simple tool for treatment delivery verification. Radiographic film placed under the patient i...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178723

    authors: Kron T,Yartsev S,Mackie TR

    更新日期:2005-12-01 00:00:00

  • The impact of inhomogeneous tissue anisotropy on potential distribution within head model.

    abstract::This paper investigates the influence of inhomogeneous head tissue conductivity on EEGs. A head model with inhomogeneity of radial and tangential conductivity is built up. Based on this model the EEG signals are calculated using the finite elements method. The results show that the inhomogeneous radial and tangential ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178780

    authors: Wen P

    更新日期:2003-09-01 00:00:00

  • Stereotactic dose perturbation from an aneurysm clip measured by Gafchromic EBT film.

    abstract::Aneurysm clips within stereotactic treatment volumes enhance spatial accuracy but perturb the dose distribution. The dose perturbations caused by a standard titanium alloy aneurysm clip (Ti6Al4V) have been measured with Gafchromic EBT film. The maximum dose perturbation was an increase of 6 % within 0.5 mm of the beam...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178449

    authors: He CF,Geso M,Ackerly T,Wong CJ

    更新日期:2008-03-01 00:00:00

  • Experimental and numerical study on the hemodynamics of stenosed carotid bifurcation.

    abstract::Numerical simulation is performed to demonstrate that hemodynamic factors are significant determinants for the development of a vascular pathology. Experimental measurements by particle image velocimetry are carried out to validate the credibility of the computational approach. We present a study for determining compl...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-010-0050-4

    authors: Cheung SC,Wong KK,Yeoh GH,Yang W,Tu J,Beare R,Phan T

    更新日期:2010-12-01 00:00:00

  • Comparison of 192Ir air kerma calibration coefficients derived at ARPANSA using the interpolation method and at the National Physical Laboratory using a direct measurement.

    abstract::The reference air kerma rate from 192Ir High Dose Rate (HDR) brachytherapy sources can be measured using a suitably calibrated Farmer chamber and an appropriate in-air calibration jig. When a primary standard for 192Ir gamma rays is available, a calibration coefficient for the chamber and jig combination can be determ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178603

    authors: Butler D,Haworth A,Sander T,Todd S

    更新日期:2008-12-01 00:00:00

  • Recent developments in radiation therapy planning and treatment optimization.

    abstract::Radiation therapy of cancer is today going through a very dynamic development with the introduction of a large number of new treatment principles, new types of treatment units and new radiobiologically based optimization algorithms for treatment planning. All of these make use of the recent developments in three dimen...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,评审

    doi:

    authors: Brahme A

    更新日期:1996-06-01 00:00:00

  • Evaluation of dose enhancement in presence of gold nanoparticles in eye brachytherapy by 103Pd source.

    abstract::In recent years, the use of gold nanoparticles in radiation therapy has been introduced as a new approach in radiotherapy. The aim of this study is to investigate the effect of gold nanoparticles (GNPs) in plaque brachytherapy for choroidal melanoma using Monte Carlo (MC) simulation. MCNPX code was used for simulation...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-017-0555-1

    authors: Rezaei H,Zabihzadeh M,Ghorbani M,Goli Ahmadabad F,Mostaghimi H

    更新日期:2017-09-01 00:00:00

  • Medical physics in 2020: will we still be relevant?

    abstract::From the time when Roentgen and other physicists made the discoveries which led to the development of radiology, radiotherapy and nuclear medicine, medical physicists have played a pivotal role in the development of new technologies that have revolutionized the way medicine is practiced today. Medical physicists have ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type:

    doi:10.1007/BF03178583

    authors: Ng KH

    更新日期:2008-06-01 00:00:00

  • Rule based fuzzy logic approach for classification of fibromyalgia syndrome.

    abstract::Fibromyalgia syndrome (FMS) is a chronic muscle and skeletal system disease observed generally in women, manifesting itself with a widespread pain and impairing the individual's quality of life. FMS diagnosis is made based on the American College of Rheumatology (ACR) criteria. However, recently the employability and ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-016-0452-z

    authors: Arslan E,Yildiz S,Albayrak Y,Koklukaya E

    更新日期:2016-06-01 00:00:00

  • Evaluation of useful neutron flux for accelerator boron neutron capture therapy using the 7Li(p,n) reaction.

    abstract::Accelerator neutron sources for epithermal neutron capture therapy utilising the 7Li(p,n) nuclear reaction are proposed to operate in the range of 1.88 to 2.5 MeV proton energy. Operation with proton energies closer to the reaction threshold decreases neutron yield but allows for smaller reflector and moderator, with ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Zimin S,Allen BJ

    更新日期:1998-12-01 00:00:00

  • The use of round ended needles for high dose rate brachytherapy implants.

    abstract::The use of Speiser needles for interstitial implants has resulted in malfunctioning of HDR afterloading equipment due to seepage of blood. We have successfully used rounded ended needles in the patient after removal of the trocar ended needles, preventing the seepage of blood. This technique also helps to prevent any ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Das KR,Duchesne G,Coles JR,Pinder P

    更新日期:1999-12-01 00:00:00

  • Fluid structure interaction (FSI) simulation of the left ventricle (LV) during the early filling wave (E-wave), diastasis and atrial contraction wave (A-wave).

    abstract::In this paper, the hemodynamic characteristics inside a physiologically correct three-dimensional LV model using fluid structure interaction scheme are examined under various heart beat conditions during early filling wave (E-wave), diastasis and atrial contraction wave (A-wave). The time dependent and incompressible ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-014-0250-4

    authors: Arefin MS,Morsi YS

    更新日期:2014-06-01 00:00:00

  • Simultaneous EEG-fMRI for working memory of the human brain.

    abstract::Memory plays an important role in human life. Memory can be divided into two categories, i.e., long term memory and short term memory (STM). STM or working memory (WM) stores information for a short span of time and it is used for information manipulations and fast response activities. WM is generally involved in the ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,评审

    doi:10.1007/s13246-016-0438-x

    authors: Ahmad RF,Malik AS,Kamel N,Reza F,Abdullah JM

    更新日期:2016-06-01 00:00:00

  • Short tangential arcs in VMAT based breast and chest wall radiotherapy lead to conformity of the breast dose with lesser cardiac and lung doses: a prospective study of breast conservation and mastectomy patients.

    abstract::Volumetric modulated arc therapy (VMAT) is modern rotational intensity modulated therapy used for treatment of several sites. The study aimed to analyze partial tangential arc VMAT treatment planning and delivery, including analyzing the cardiac and contralateral breast doses resulting from this technique. A total of ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-017-0558-y

    authors: Munshi A,Sarkar B,Anbazhagan S,Giri UK,Kaur H,Jassal K,Ganesh T,Kalyan Mohanti B

    更新日期:2017-09-01 00:00:00

  • Depth of anaesthesia assessment based on adult electroencephalograph beta frequency band.

    abstract::This paper presents a new method to apply timing characteristics of electroencephalograph (EEG) beta frequency bands to assess the depth of anaesthesia (DoA). Firstly, the measured EEG signals are denoised and decomposed into 20 different frequency bands. The Mobility (M), permutation entropy (PE) and Lempel-Ziv compl...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-016-0459-5

    authors: Li T,Wen P

    更新日期:2016-09-01 00:00:00

  • Management and autopsy of a radioactive cadaver.

    abstract::A 69 year old male was treated with an ablative dose of 3.7 GBq (100 mCi) of I131 for carcinoma of the thyroid and died 10 days after administration. The requirement for an autopsy and the level of radiation still present in the body necessitated the intervention of Radiation Safety Personnel to minimise support staff...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Wallace AB,Bush V

    更新日期:1991-06-01 00:00:00

  • Proposing feature engineering method based on deep learning and K-NNs for ECG beat classification and arrhythmia detection.

    abstract::Arrhythmia is slow, fast or irregular heartbeat. Manual ECG assessment and disease classification is an error-prone task because of vast differences in ECG morphology and difficulty in accurate identifying ECG components. Moreover, proposing a computer-aided diagnosis system for heartbeat classification can be useful ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-019-00814-w

    authors: Khatibi T,Rabinezhadsadatmahaleh N

    更新日期:2019-11-26 00:00:00

  • The clinical value of ophthalmic electrodiagnosis in children.

    abstract::A group of 113 children with poor vision who had been referred to the Electrodiagnostic Clinic over a five year period were investigated for disease of the retina and optic pathway by electroretinography (ERG), electro-oculography (EOG) and visual evoked response (VER). The electrodiagnostic measurements were made usi...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178360

    authors: Hidajat RR,Goode DH

    更新日期:2001-09-01 00:00:00

  • A phantom for verification of dwell position and time of a high dose rate brachytherapy source.

    abstract::Accuracy of dwell position and reproducibility of dwell time are critical in high dose rate (HDR) brachytherapy. A phantom was designed to verify dwell position and dwell time reproducibility for an Ir-192 HDR stepping source using Computed Radiography (CR). The central part of the phantom, incorporating thin alternat...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-012-0138-0

    authors: Madebo M,Pillainayagam J,Kron T,Franich R

    更新日期:2012-09-01 00:00:00

  • A simulation study comparing nine mathematical models of arterial input function for dynamic contrast enhanced MRI to the Parker model.

    abstract::Due to large inter- and intra-patient variabilities of arterial input functions (AIFs), accurately modeling and using patient-specific AIF are very important for quantitative analysis of dynamic contrast enhanced MRI. Computer simulations were performed to evaluate and compare nine population AIF models with the Parke...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-018-0632-0

    authors: He D,Xu L,Qian W,Clarke J,Fan X

    更新日期:2018-06-01 00:00:00

  • Non invasive measurement of myocardial motion using magnetic resonance tagging.

    abstract::Magnetic resonance imaging has become a key modality within the modern radiology department. In addition to the conventional slice images, three dimensional angiographic images, and quantitative flow measurements can be obtained. More recently methods have been developed which enable one to visualize the motion of obj...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,评审

    doi:

    authors: McKinnon GC,Fischer SE,Maier SE

    更新日期:1991-12-01 00:00:00

  • Computer model to optimise contrast in chest radiography.

    abstract::X-ray imaging of the chest is challenging because of the large differences in x-ray attenuation between the mediastinal and lung regions of the chest. This large dynamic range of chest exit exposure, along with associated large changes in the scatter component of the beam, makes film based chest imaging difficult to o...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: McLean D

    更新日期:1993-12-01 00:00:00