Abstract:
:At present, the Australasian College of Physical Scientists and Engineers in Medicine does not support the practice of self-referred whole-body CT screening of asymptomatic patients because: The procedure involves a non-trivial radiation dose, which assumes even greater significance in the context of an ongoing screening programme; There is a high likelihood of false positives requiring further intervention with its attendant risks; and There is no proven evidence to date that early detection of life-threatening disease by CT has a significant positive effect on patient outcome. The ACPSEM will continue to monitor scientific studies concerning this procedure.
journal_name
Australas Phys Eng Sci Medjournal_title
Australasian physical & engineering sciences in medicineauthors
Le Heron JC,Coakley KSdoi
10.1007/BF03178880subject
Has Abstractpub_date
2004-03-01 00:00:00pages
1-4issue
1eissn
0158-9938issn
1879-5447journal_volume
27pub_type
指南,杂志文章abstract::Orthovoltage x-ray beams exhibit the characteristic of depth dose buildup which is not well described in the literature. The principal reason for this phenomenon is the increase in dose deposited due to electrons set in motion by secondary (Compton) scattered photons within the phantom, as depth is increased until lon...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1998-06-01 00:00:00
abstract::From the time when Roentgen and other physicists made the discoveries which led to the development of radiology, radiotherapy and nuclear medicine, medical physicists have played a pivotal role in the development of new technologies that have revolutionized the way medicine is practiced today. Medical physicists have ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type:
doi:10.1007/BF03178583
更新日期:2008-06-01 00:00:00
abstract::Cone-beam computed tomography (CBCT) has become the standard imaging technique for many sites treated with Radiotherapy. The Elekta X-ray Volumetric Imaging (XVI) system allows for the acquisition of CBCTs with three different diameters; small (27 cm), medium (41 cm) and large (50 cm) (Elekta in XVI Corrective Mainten...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-019-00817-7
更新日期:2019-12-01 00:00:00
abstract::The effect of radiation in regard to breast carcinogenesis is well studied and analysed from data from atomic bomb survivors, patients treated for acute mastitis and tuberculosis patients monitored by fluoroscopy. Therefore the radiation received by the untreated breast during breast irradiation of the other breast, i...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/BF03178353
更新日期:2001-06-01 00:00:00
abstract::Obesity management is a key point during cardiac rehabilitation. The effect of new index, waist circumference (WC), in the obesity management of cardiac rehabilitation is not clear yet. Therefore, our study compared the WC index to the body mass index (BMI) in the evaluation of obesity management for the patients with...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 临床试验,杂志文章
doi:10.1007/s13246-016-0471-9
更新日期:2016-12-01 00:00:00
abstract::This article outlines the enormous technological advances that have taken place in the practice of radiology in Australasia in the 30 years since approximately 1977. These developments have led to significant improvements in image quality across all modalities, including even general radiography, which had as its gene...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章,评审
doi:10.1007/BF03178423
更新日期:2007-09-01 00:00:00
abstract::It was the aim of this work to assess and track the workload, working conditions and professional recognition of radiation oncology medical physicists (ROMPs) in the Asia Pacific region over time. In this third survey since 2008, a structured questionnaire was mailed in 2014 to 22 senior medical physicists representin...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-015-0373-2
更新日期:2015-09-01 00:00:00
abstract::Segmentation of different tissues is one of the initial and most critical tasks in different aspects of medical image processing. Manual segmentation of brain images resulted from magnetic resonance imaging is time consuming, so automatic image segmentation is widely used in this area. Ensemble based algorithms are ve...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-015-0352-7
更新日期:2015-06-01 00:00:00
abstract::Arrhythmia is slow, fast or irregular heartbeat. Manual ECG assessment and disease classification is an error-prone task because of vast differences in ECG morphology and difficulty in accurate identifying ECG components. Moreover, proposing a computer-aided diagnosis system for heartbeat classification can be useful ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-019-00814-w
更新日期:2019-11-26 00:00:00
abstract::Postural balance requires using joint strategies which may be changed from normal conditions by interfering with the sensory information. The goal of the present study was to quantitatively evaluate the role of the joint mechanisms during perturbed stance. Visual and cognitive interference was imposed to sixteen healt...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-017-0606-7
更新日期:2018-03-01 00:00:00
abstract::Currently, a software-based second check dose calculation for helical tomotherapy (HT) is not available. The goal of this study is to evaluate the dose calculation accuracy of the in-house software using EGS4/MCSIM Monte Carlo environment against the treatment planning system calculations. In-house software was used t...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-012-0165-x
更新日期:2012-12-01 00:00:00
abstract::Peripheral doses out of field could have short and long terms biological effects on patients treated with electron beams. In this study, peripheral dose outside the applicator was measured using the 6, 10 and 18 MeV beams of an Elekta synergy linac. For these beams dose profiles were measured using EBT3 film at variou...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-018-0660-9
更新日期:2018-09-01 00:00:00
abstract::Compression techniques are vital for efficient storage and fast transfer of medical image data. The existing compression techniques take significant amount of time for performing encoding and decoding and hence the purpose of compression is not fully satisfied. In this paper a rapid 4-D lossy compression method constr...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-015-0385-y
更新日期:2015-12-01 00:00:00
abstract::The Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) Radiation Oncology Specialty Group (ROSG) formed a series of working groups in 2011 to develop position papers for guidance of radiation oncology medical physics practice within the Australasian setting. These position papers are intend...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-013-0238-5
更新日期:2014-03-01 00:00:00
abstract::The use of Speiser needles for interstitial implants has resulted in malfunctioning of HDR afterloading equipment due to seepage of blood. We have successfully used rounded ended needles in the patient after removal of the trocar ended needles, preventing the seepage of blood. This technique also helps to prevent any ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1999-12-01 00:00:00
abstract::Linear scaling is used to convert raw computed tomography (CT) pixel values into Hounsfield units corresponding to different tissue values. Analysis of a benchmarking study, presented here, where the same CT scan was imported into and then exported from multiple radiotherapy treatment planning systems, found inconsist...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-018-0651-x
更新日期:2018-09-01 00:00:00
abstract::Surface, build-up and depth dose characteristics of a monoenergetic electron point source simulated by Monte Carlo code MCNP4c for varying field size and SSD are extensively studied in this paper. MCNP4c (Monte Carlo N-Particle Transport Code System) has been extensively used in clinical dose simulation for its versat...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/BF03178652
更新日期:2004-12-01 00:00:00
abstract::Numerical simulation is performed to demonstrate that hemodynamic factors are significant determinants for the development of a vascular pathology. Experimental measurements by particle image velocimetry are carried out to validate the credibility of the computational approach. We present a study for determining compl...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-010-0050-4
更新日期:2010-12-01 00:00:00
abstract::Wavelet theory is emerging as one of the prevalent tool in signal and image processing applications. However, the most suitable mother wavelet for these applications is still a relative question mark amongst researchers. Selection of best mother wavelet through parameterization leads to better findings for the analysi...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-014-0264-y
更新日期:2014-06-01 00:00:00
abstract::Thermoluminescence dosimetry (TLD) is a versatile tool for the assessment of dose from ionising radiation. The wide variety of TLD materials and their different physical forms allow the determination of different radiation qualities at dose levels from microGy to kGy. Major advantages of TL dosimeters are their small ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章,评审
doi:
更新日期:1994-12-01 00:00:00
abstract::The assignment of pathogenicity to variants suspected of causing an inherited retinal disease and the subsequent creation of molecular genetic reports sent to clinical geneticists and ophthalmologists has traditionally been time-consuming and subject to error and ambiguity. The purpose of this paper is to describe a c...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-015-0420-z
更新日期:2016-03-01 00:00:00
abstract::A variable magnetic deflector which attaches onto the treatment head of a linear accelerator has reduced skin dose by as much as 65% for 6MV x-rays. The magnetic deflector is constructed from Neodymium Iron Boron (NdFeB) rare earth magnets. It weighs approximately 15 kg and is designed to easily fit onto the accessory...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1997-06-01 00:00:00
abstract::Accuracy of dwell position and reproducibility of dwell time are critical in high dose rate (HDR) brachytherapy. A phantom was designed to verify dwell position and dwell time reproducibility for an Ir-192 HDR stepping source using Computed Radiography (CR). The central part of the phantom, incorporating thin alternat...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-012-0138-0
更新日期:2012-09-01 00:00:00
abstract::In this study, we assessed the accuracy of surface doses determined by direct measurement and treatment planning system (TPS) calculations, relative to benchmark Monte Carlo (MC) doses calculated at 70 μm for a 6 MV, 10 × 10 cm clinical radiotherapy beam. In a homogeneous phantom with both open and fixed wedged fields...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-012-0145-1
更新日期:2012-09-01 00:00:00
abstract::Aneurysm clips within stereotactic treatment volumes enhance spatial accuracy but perturb the dose distribution. The dose perturbations caused by a standard titanium alloy aneurysm clip (Ti6Al4V) have been measured with Gafchromic EBT film. The maximum dose perturbation was an increase of 6 % within 0.5 mm of the beam...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/BF03178449
更新日期:2008-03-01 00:00:00
abstract::The knowledge of radiation dose at all points of interest within a patient's body is essential for the evaluation of treatment plans and for the judicious selection of the best one from among a set of competing plans. This paper discusses the physical and geometric aspects of radiation dose distribution calculations n...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1989-12-01 00:00:00
abstract::Cricket bowling generates forces with torques on the upper limb muscles and makes the biceps brachii (BB) muscle vulnerable to overuse injury. The aim of this study was to investigate whether there are differences in the amplitude of the EMG signal of the BB muscle during fast and spin delivery, during the seven phase...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-014-0245-1
更新日期:2014-03-01 00:00:00
abstract::In general, a weighting factor of one is applied for low linear energy transfer radiations. However, several studies indicate that relative biological effectiveness (RBE) of low energy photons and electrons is greater than one. The aim of this current study was calculating the RBE of I-131 radiation relative to Co-60 ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-017-0544-4
更新日期:2017-06-01 00:00:00
abstract::A general purpose, multi-channel digital data acquisition and analysis system (Amlab, Associative Measurements, Sydney) configured to collect and process physiological signals including electroencephalograph and blood pressure is described. Its advantages over analog and single-purpose instrumentation are discussed as...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1995-09-01 00:00:00
abstract::The Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) radiation oncology specialty group (ROSG) formed a series of working groups in 2011 to develop recommendations for guidance of radiation oncology medical physics practice within the Australasian setting. These recommendations are intend...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章,实务指引
doi:10.1007/s13246-015-0344-7
更新日期:2015-06-01 00:00:00