CT screening--whole-body and targeted.

Abstract:

:At present, the Australasian College of Physical Scientists and Engineers in Medicine does not support the practice of self-referred whole-body CT screening of asymptomatic patients because: The procedure involves a non-trivial radiation dose, which assumes even greater significance in the context of an ongoing screening programme; There is a high likelihood of false positives requiring further intervention with its attendant risks; and There is no proven evidence to date that early detection of life-threatening disease by CT has a significant positive effect on patient outcome. The ACPSEM will continue to monitor scientific studies concerning this procedure.

authors

Le Heron JC,Coakley KS

doi

10.1007/BF03178880

subject

Has Abstract

pub_date

2004-03-01 00:00:00

pages

1-4

issue

1

eissn

0158-9938

issn

1879-5447

journal_volume

27

pub_type

指南,杂志文章
  • Photon buildup in orthovoltage X-ray beams.

    abstract::Orthovoltage x-ray beams exhibit the characteristic of depth dose buildup which is not well described in the literature. The principal reason for this phenomenon is the increase in dose deposited due to electrons set in motion by secondary (Compton) scattered photons within the phantom, as depth is increased until lon...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Hill RF,Keall PJ,Beckham WA,Perez MD

    更新日期:1998-06-01 00:00:00

  • Medical physics in 2020: will we still be relevant?

    abstract::From the time when Roentgen and other physicists made the discoveries which led to the development of radiology, radiotherapy and nuclear medicine, medical physicists have played a pivotal role in the development of new technologies that have revolutionized the way medicine is practiced today. Medical physicists have ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type:

    doi:10.1007/BF03178583

    authors: Ng KH

    更新日期:2008-06-01 00:00:00

  • Image quality improvement for medium and large field of view Elekta XVI scans.

    abstract::Cone-beam computed tomography (CBCT) has become the standard imaging technique for many sites treated with Radiotherapy. The Elekta X-ray Volumetric Imaging (XVI) system allows for the acquisition of CBCTs with three different diameters; small (27 cm), medium (41 cm) and large (50 cm) (Elekta in XVI Corrective Mainten...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-019-00817-7

    authors: Little DP

    更新日期:2019-12-01 00:00:00

  • Measurement of dose to the contralateral breast during radiation therapy for breast cancer: reduction by the use of superflab.

    abstract::The effect of radiation in regard to breast carcinogenesis is well studied and analysed from data from atomic bomb survivors, patients treated for acute mastitis and tuberculosis patients monitored by fluoroscopy. Therefore the radiation received by the untreated breast during breast irradiation of the other breast, i...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178353

    authors: Jamal N,Das KR

    更新日期:2001-06-01 00:00:00

  • Investigating the differences of body mass index and waist circumference in the follow-up assessment of patients to cardiac rehabilitation with acute coronary syndrome.

    abstract::Obesity management is a key point during cardiac rehabilitation. The effect of new index, waist circumference (WC), in the obesity management of cardiac rehabilitation is not clear yet. Therefore, our study compared the WC index to the body mass index (BMI) in the evaluation of obesity management for the patients with...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1007/s13246-016-0471-9

    authors: Zhao H,Ma J,Zhou Q,Chen W,Zhu W,Cai Z,Lei H,Deng Y,Xu L,Qiu J

    更新日期:2016-12-01 00:00:00

  • Technical developments in radiology in Australasia dating from 1977.

    abstract::This article outlines the enormous technological advances that have taken place in the practice of radiology in Australasia in the 30 years since approximately 1977. These developments have led to significant improvements in image quality across all modalities, including even general radiography, which had as its gene...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,评审

    doi:10.1007/BF03178423

    authors: Heggie JC

    更新日期:2007-09-01 00:00:00

  • Medical physics aspects of cancer care in the Asia Pacific region: 2014 survey results.

    abstract::It was the aim of this work to assess and track the workload, working conditions and professional recognition of radiation oncology medical physicists (ROMPs) in the Asia Pacific region over time. In this third survey since 2008, a structured questionnaire was mailed in 2014 to 22 senior medical physicists representin...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0373-2

    authors: Kron T,Azhari HA,Voon EO,Cheung KY,Ravindran P,Soejoko D,Inamura K,Han Y,Ung NM,TsedenIsh B,Win UM,Srivastava R,Marsh S,Farrukh S,Rodriguez L,Kuo M,Baggarley S,DilipKumara AH,Lee CC,Krisanachinda A,Nguyen XC,Ng

    更新日期:2015-09-01 00:00:00

  • Supervised segmentation of MRI brain images using combination of multiple classifiers.

    abstract::Segmentation of different tissues is one of the initial and most critical tasks in different aspects of medical image processing. Manual segmentation of brain images resulted from magnetic resonance imaging is time consuming, so automatic image segmentation is widely used in this area. Ensemble based algorithms are ve...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0352-7

    authors: Ahmadvand A,Sharififar M,Daliri MR

    更新日期:2015-06-01 00:00:00

  • Proposing feature engineering method based on deep learning and K-NNs for ECG beat classification and arrhythmia detection.

    abstract::Arrhythmia is slow, fast or irregular heartbeat. Manual ECG assessment and disease classification is an error-prone task because of vast differences in ECG morphology and difficulty in accurate identifying ECG components. Moreover, proposing a computer-aided diagnosis system for heartbeat classification can be useful ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-019-00814-w

    authors: Khatibi T,Rabinezhadsadatmahaleh N

    更新日期:2019-11-26 00:00:00

  • Effects of visual and cognitive interference on joint contributions in perturbed standing: a temporal and spectral analysis.

    abstract::Postural balance requires using joint strategies which may be changed from normal conditions by interfering with the sensory information. The goal of the present study was to quantitatively evaluate the role of the joint mechanisms during perturbed stance. Visual and cognitive interference was imposed to sixteen healt...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-017-0606-7

    authors: Ashtiani MN,Azghani MR

    更新日期:2018-03-01 00:00:00

  • Performance of independent dose calculation in helical tomotherapy: implementation of the MCSIM code.

    abstract::Currently, a software-based second check dose calculation for helical tomotherapy (HT) is not available. The goal of this study is to evaluate the dose calculation accuracy of the in-house software using EGS4/MCSIM Monte Carlo environment against the treatment planning system calculations. In-house software was used t...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-012-0165-x

    authors: Dzintars E,Stathakis S,Mavroidis P,Sadeghi A,Papanikolaou N

    更新日期:2012-12-01 00:00:00

  • The peripheral dose outside the applicator in electron beams of an Elekta linear accelerator.

    abstract::Peripheral doses out of field could have short and long terms biological effects on patients treated with electron beams. In this study, peripheral dose outside the applicator was measured using the 6, 10 and 18 MeV beams of an Elekta synergy linac. For these beams dose profiles were measured using EBT3 film at variou...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-018-0660-9

    authors: Haghparast A,Amiri F,Yarahmadi M,Rezaei M

    更新日期:2018-09-01 00:00:00

  • A rapid compression technique for 4-D functional MRI images using data rearrangement and modified binary array techniques.

    abstract::Compression techniques are vital for efficient storage and fast transfer of medical image data. The existing compression techniques take significant amount of time for performing encoding and decoding and hence the purpose of compression is not fully satisfied. In this paper a rapid 4-D lossy compression method constr...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0385-y

    authors: Uma Vetri Selvi G,Nadarajan R

    更新日期:2015-12-01 00:00:00

  • ACPSEM ROSG Oncology-PACS and OIS working group recommendations for quality assurance.

    abstract::The Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) Radiation Oncology Specialty Group (ROSG) formed a series of working groups in 2011 to develop position papers for guidance of radiation oncology medical physics practice within the Australasian setting. These position papers are intend...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-013-0238-5

    authors: Shakeshaft J,Perez M,Tremethick L,Ceylan A,Bailey M

    更新日期:2014-03-01 00:00:00

  • The use of round ended needles for high dose rate brachytherapy implants.

    abstract::The use of Speiser needles for interstitial implants has resulted in malfunctioning of HDR afterloading equipment due to seepage of blood. We have successfully used rounded ended needles in the patient after removal of the trocar ended needles, preventing the seepage of blood. This technique also helps to prevent any ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Das KR,Duchesne G,Coles JR,Pinder P

    更新日期:1999-12-01 00:00:00

  • Estimation of Hounsfield unit conversion parameters for pelvic CT images.

    abstract::Linear scaling is used to convert raw computed tomography (CT) pixel values into Hounsfield units corresponding to different tissue values. Analysis of a benchmarking study, presented here, where the same CT scan was imported into and then exported from multiple radiotherapy treatment planning systems, found inconsist...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-018-0651-x

    authors: Kennedy A,Dowling J,Greer PB,Ebert MA

    更新日期:2018-09-01 00:00:00

  • Effects of treatment distance and field size on build-up characteristics of Monte Carlo calculated absorbed dose for electron irradiation.

    abstract::Surface, build-up and depth dose characteristics of a monoenergetic electron point source simulated by Monte Carlo code MCNP4c for varying field size and SSD are extensively studied in this paper. MCNP4c (Monte Carlo N-Particle Transport Code System) has been extensively used in clinical dose simulation for its versat...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178652

    authors: Lin H,Wu DS,Wu AD

    更新日期:2004-12-01 00:00:00

  • Experimental and numerical study on the hemodynamics of stenosed carotid bifurcation.

    abstract::Numerical simulation is performed to demonstrate that hemodynamic factors are significant determinants for the development of a vascular pathology. Experimental measurements by particle image velocimetry are carried out to validate the credibility of the computational approach. We present a study for determining compl...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-010-0050-4

    authors: Cheung SC,Wong KK,Yeoh GH,Yang W,Tu J,Beare R,Phan T

    更新日期:2010-12-01 00:00:00

  • Optimal selection of mother wavelet for accurate infant cry classification.

    abstract::Wavelet theory is emerging as one of the prevalent tool in signal and image processing applications. However, the most suitable mother wavelet for these applications is still a relative question mark amongst researchers. Selection of best mother wavelet through parameterization leads to better findings for the analysi...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-014-0264-y

    authors: Saraswathy J,Hariharan M,Nadarajaw T,Khairunizam W,Yaacob S

    更新日期:2014-06-01 00:00:00

  • Thermoluminescence dosimetry and its applications in medicine--Part 1: Physics, materials and equipment.

    abstract::Thermoluminescence dosimetry (TLD) is a versatile tool for the assessment of dose from ionising radiation. The wide variety of TLD materials and their different physical forms allow the determination of different radiation qualities at dose levels from microGy to kGy. Major advantages of TL dosimeters are their small ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,评审

    doi:

    authors: Kron T

    更新日期:1994-12-01 00:00:00

  • A computer-assisted method for pathogenicity assessment and genetic reporting of variants stored in the Australian Inherited Retinal Disease Register.

    abstract::The assignment of pathogenicity to variants suspected of causing an inherited retinal disease and the subsequent creation of molecular genetic reports sent to clinical geneticists and ophthalmologists has traditionally been time-consuming and subject to error and ambiguity. The purpose of this paper is to describe a c...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0420-z

    authors: Huynh E,De Roach J,McLaren T,Thompson J,Montgomery H,Kap C,Hoffmann L,Lamey T

    更新日期:2016-03-01 00:00:00

  • Skin dose reduction by a clinically viable magnetic deflector.

    abstract::A variable magnetic deflector which attaches onto the treatment head of a linear accelerator has reduced skin dose by as much as 65% for 6MV x-rays. The magnetic deflector is constructed from Neodymium Iron Boron (NdFeB) rare earth magnets. It weighs approximately 15 kg and is designed to easily fit onto the accessory...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Butson MJ,Yu P,Kan M,Carolan M,Young E,Mathur JN,Metcalfe PE

    更新日期:1997-06-01 00:00:00

  • A phantom for verification of dwell position and time of a high dose rate brachytherapy source.

    abstract::Accuracy of dwell position and reproducibility of dwell time are critical in high dose rate (HDR) brachytherapy. A phantom was designed to verify dwell position and dwell time reproducibility for an Ir-192 HDR stepping source using Computed Radiography (CR). The central part of the phantom, incorporating thin alternat...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-012-0138-0

    authors: Madebo M,Pillainayagam J,Kron T,Franich R

    更新日期:2012-09-01 00:00:00

  • Practical considerations for reporting surface dose in external beam radiotherapy: a 6 MV X-ray beam study.

    abstract::In this study, we assessed the accuracy of surface doses determined by direct measurement and treatment planning system (TPS) calculations, relative to benchmark Monte Carlo (MC) doses calculated at 70 μm for a 6 MV, 10 × 10 cm clinical radiotherapy beam. In a homogeneous phantom with both open and fixed wedged fields...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-012-0145-1

    authors: Kim JH,Hill R,Kuncic Z

    更新日期:2012-09-01 00:00:00

  • Stereotactic dose perturbation from an aneurysm clip measured by Gafchromic EBT film.

    abstract::Aneurysm clips within stereotactic treatment volumes enhance spatial accuracy but perturb the dose distribution. The dose perturbations caused by a standard titanium alloy aneurysm clip (Ti6Al4V) have been measured with Gafchromic EBT film. The maximum dose perturbation was an increase of 6 % within 0.5 mm of the beam...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178449

    authors: He CF,Geso M,Ackerly T,Wong CJ

    更新日期:2008-03-01 00:00:00

  • Dose computations for three-dimensional radiation treatment planning.

    abstract::The knowledge of radiation dose at all points of interest within a patient's body is essential for the evaluation of treatment plans and for the judicious selection of the best one from among a set of competing plans. This paper discusses the physical and geometric aspects of radiation dose distribution calculations n...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Mohan R

    更新日期:1989-12-01 00:00:00

  • Surface electromyographic analysis of the biceps brachii muscle of cricket bowlers during bowling.

    abstract::Cricket bowling generates forces with torques on the upper limb muscles and makes the biceps brachii (BB) muscle vulnerable to overuse injury. The aim of this study was to investigate whether there are differences in the amplitude of the EMG signal of the BB muscle during fast and spin delivery, during the seven phase...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-014-0245-1

    authors: Ahamed NU,Sundaraj K,Ahmad B,Rahman M,Ali MA,Islam MA

    更新日期:2014-03-01 00:00:00

  • Monte Carlo simulation of the RBE of I-131 radiation using DNA damage as biomarker.

    abstract::In general, a weighting factor of one is applied for low linear energy transfer radiations. However, several studies indicate that relative biological effectiveness (RBE) of low energy photons and electrons is greater than one. The aim of this current study was calculating the RBE of I-131 radiation relative to Co-60 ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-017-0544-4

    authors: Ezzati AO,Mahmoud-Pashazadeh A,Studenski MT

    更新日期:2017-06-01 00:00:00

  • Continuous physiological monitoring: an integrated system for use in neonatal intensive care.

    abstract::A general purpose, multi-channel digital data acquisition and analysis system (Amlab, Associative Measurements, Sydney) configured to collect and process physiological signals including electroencephalograph and blood pressure is described. Its advantages over analog and single-purpose instrumentation are discussed as...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Hall GL,Colditz PB

    更新日期:1995-09-01 00:00:00

  • ACPSEM ROSG TBI working group recommendations for quality assurance in total body irradiation.

    abstract::The Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) radiation oncology specialty group (ROSG) formed a series of working groups in 2011 to develop recommendations for guidance of radiation oncology medical physics practice within the Australasian setting. These recommendations are intend...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,实务指引

    doi:10.1007/s13246-015-0344-7

    authors: Nelligan R,Bailey M,Tran T,Baldwin Z,ACPSEM total body irradiation working group.

    更新日期:2015-06-01 00:00:00