Abstract:
:Shear wave elasticity imaging (SWEI) has been used to measure the local tissue elasticity. The local tissue shear modulus can be reconstructed from the displacement field of shear waves using an algebraic Helmholtz inversion (AHI) equation or a time-of-flight (TOF)-based algorithm. The shear waves, which are generated by successive focusing of ultrasonic beams at different depths, propagate at oblique angles rather than along the lateral position. The wave propagation at oblique angles can result in bias in shear modulus reconstruction using the AHI equation or the TOF-based algorithm. In this study, the effect of wave propagation at oblique angles on the tissue shear modulus reconstruction was investigated using in silico finite element (FE) simulation. An FE elastic tissue with a hard inclusion model was designed. The shear waves with propagation angles of 0°, 5°, and 10° were applied to the model. The shear modulus and the percentage error in the model were computed using the AHI equation and the TOF-based algorithm at each propagation angle from 0° to 10°. For the AHI equation, the percentage error was 0% at propagation angles of 0° and 5°, and 1% at a propagation angle of 10° in the inclusion. In the surrounding tissue, the percentage error was 0% at propagation angles of 0°, 5°, and 10°. For the TOF-based algorithm, the percentage error was 0% at propagation angles of 0° and 5°, and 40% at a propagation angle of 10° in the inclusion. In the surrounding tissue, the percentage error was 0% at propagation angles of 0° and 5°, and 35% at a propagation angle of 10° in the inclusion. Therefore, whereas the TOF-based algorithm produced critical bias in shear modulus reconstruction by the shear wave propagation at oblique angles, the AHI equation was not affected by the propagation.
journal_name
Australas Phys Eng Sci Medjournal_title
Australasian physical & engineering sciences in medicineauthors
Park DW,Cho HCdoi
10.1007/s13246-019-00748-3subject
Has Abstractpub_date
2019-09-01 00:00:00pages
665-670issue
3eissn
0158-9938issn
1879-5447pii
10.1007/s13246-019-00748-3journal_volume
42pub_type
杂志文章abstract::Coronary artery disease producing ischemic cardiomyopathy is the most frequent cause of left ventricular systolic dysfunction. Non-ischemic cardiomyopathies can also produce systolic dysfunction; they may be inherited as genetic disorders or occur sporadically. These coronary injuries have repercussions on the left ve...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/BF03178864
更新日期:2005-03-01 00:00:00
abstract::Orthovoltage x-ray beams exhibit the characteristic of depth dose buildup which is not well described in the literature. The principal reason for this phenomenon is the increase in dose deposited due to electrons set in motion by secondary (Compton) scattered photons within the phantom, as depth is increased until lon...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1998-06-01 00:00:00
abstract::Super-pixel feature extraction is a key problem to get an acceptable performance in color super-pixel classification. Given a color feature extraction problem, it is necessary to know which is the best approach to solve this problem. In the current work, we're interested in the challenge of nucleus and cytoplasm autom...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-019-00735-8
更新日期:2019-06-01 00:00:00
abstract::The aim of this study was to determine whether there is an effect of mobile phone electromagnetic field emissions on the human electroencephalograph (EEG). EEG recordings from ten awake subjects were taken during exposure to radiofrequency (RF) emissions from a mobile phone positioned behind the head. Two experimental...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1007/BF03179176
更新日期:2003-12-01 00:00:00
abstract::A continuous positive airway pressure (CPAP) device is considered one of the most effective treatments for obstructive sleep apnea (OSA). However, many patients receiving this treatment complain of mask discomfort and other issues. Therefore, this study aimed to develop a customized nasal mask cushion to reduce the di...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-015-0383-0
更新日期:2015-12-01 00:00:00
abstract::Compression techniques are vital for efficient storage and fast transfer of medical image data. The existing compression techniques take significant amount of time for performing encoding and decoding and hence the purpose of compression is not fully satisfied. In this paper a rapid 4-D lossy compression method constr...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-015-0385-y
更新日期:2015-12-01 00:00:00
abstract::Volumetric modulated arc therapy (VMAT) is modern rotational intensity modulated therapy used for treatment of several sites. The study aimed to analyze partial tangential arc VMAT treatment planning and delivery, including analyzing the cardiac and contralateral breast doses resulting from this technique. A total of ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-017-0558-y
更新日期:2017-09-01 00:00:00
abstract::Given that there is increasing recognition of the effect that sub-millimetre changes in collimator position can have on radiotherapy beam dosimetry, this study aimed to evaluate the potential variability in small field collimation that may exist between otherwise matched linacs. Field sizes and field output factors we...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-015-0349-2
更新日期:2015-06-01 00:00:00
abstract::The alcoholism can be detected by analyzing electroencephalogram (EEG) signals. However, analyzing multi-channel EEG signals is a challenging task, which often requires complicated calculations and long execution time. This paper proposes three data selection methods to extract representative data from the EEG signals...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-015-0414-x
更新日期:2016-03-01 00:00:00
abstract::Segmentation of different tissues is one of the initial and most critical tasks in different aspects of medical image processing. Manual segmentation of brain images resulted from magnetic resonance imaging is time consuming, so automatic image segmentation is widely used in this area. Ensemble based algorithms are ve...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-015-0352-7
更新日期:2015-06-01 00:00:00
abstract::The effect of radiation in regard to breast carcinogenesis is well studied and analysed from data from atomic bomb survivors, patients treated for acute mastitis and tuberculosis patients monitored by fluoroscopy. Therefore the radiation received by the untreated breast during breast irradiation of the other breast, i...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/BF03178353
更新日期:2001-06-01 00:00:00
abstract::In-phantom figures of merit of the radiobiological dose distribution are the main criteria for evaluation of the boron neutron capture therapy (BNCT) plan and neutron beam evaluation. Since in BNCT there are several reactions, which contribute to the total dose of the tissue, the calculation of the dose distribution i...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-011-0107-z
更新日期:2011-12-01 00:00:00
abstract::A simple and rapid technique to measure the proton beam energy in the external beam line of a medical cyclotron has been examined. A stack of 0.1 mm thick high purity copper (Cu) foils was bombarded and the relative activity of 65Zn produced in each foil was compared to a computational model that predicted activity, b...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/BF03178634
更新日期:2009-06-01 00:00:00
abstract::This paper presents a new method to apply timing characteristics of electroencephalograph (EEG) beta frequency bands to assess the depth of anaesthesia (DoA). Firstly, the measured EEG signals are denoised and decomposed into 20 different frequency bands. The Mobility (M), permutation entropy (PE) and Lempel-Ziv compl...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-016-0459-5
更新日期:2016-09-01 00:00:00
abstract::Bicoherence analysis is applied to electromyogram (EMG) data for the vastus lateralis quadriceps muscle of 18 adult male subjects for isometric knee extension exercise. Bicoherence spectra display ridge-like features that are indicative of deterministic chaotic behaviour and similar to those reported for normal electr...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 临床试验,杂志文章
doi:10.1007/BF03178691
更新日期:2003-03-01 00:00:00
abstract::The accuracy of a computed tomography (CT)-relative electron density (RED) curve may have an indirect impact on the accuracy of dose calculation by a treatment planning system (TPS). This effect has not been previously quantified for input of different CT-RED curves from different CT-scan units in the Monaco TPS. This...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-019-00745-6
更新日期:2019-06-01 00:00:00
abstract::The purpose of this study is to develop a novel breast abnormality detection system by utilizing the potential of infrared breast thermography (IBT) in early breast abnormality detection. Since the temperature distributions are different in normal and abnormal thermograms and hot thermal patches are visible in abnorma...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-018-0681-4
更新日期:2018-12-01 00:00:00
abstract::Currently, a software-based second check dose calculation for helical tomotherapy (HT) is not available. The goal of this study is to evaluate the dose calculation accuracy of the in-house software using EGS4/MCSIM Monte Carlo environment against the treatment planning system calculations. In-house software was used t...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-012-0165-x
更新日期:2012-12-01 00:00:00
abstract::Conventional laser accelerated proton beam has broad energy spectra. It is not suitable for clinical use directly, so it is necessary for employing energy selection system. However, in the conventional laser accelerated proton system, the intensity of the proton beams in the low energy regime is higher than that in th...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-014-0292-7
更新日期:2014-12-01 00:00:00
abstract::In recent years there has been a significant economic growth in South East Asia, along with it a concurrent development of medical physics. The status of four countries--Malaysia, Thailand, the Philippines and Indonesia are presented. Medical physicists in these countries have been experiencing the usual problems of l...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1997-03-01 00:00:00
abstract::The umbilical cord is part of the fetus and generally includes one umbilical vein (UV) and two umbilical arteries (UAs). As the saphenous vein and UV are the most commonly used veins for the coronary artery disease treatment as a coronary artery bypass graft (CABG), understating the mechanical properties of UV has a k...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-014-0294-5
更新日期:2014-12-01 00:00:00
abstract::Rats are often used in the electromagnetic field (EMF) exposure experiments. In the study for the effect of 900 MHz EMF exposure on learning and memory in SD rats, the specific absorption rate (SAR) and the temperature rise in the rat head are numerically evaluated. The digital anatomical model of a SD rat is reconstr...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-013-0202-4
更新日期:2013-06-01 00:00:00
abstract::A group of 113 children with poor vision who had been referred to the Electrodiagnostic Clinic over a five year period were investigated for disease of the retina and optic pathway by electroretinography (ERG), electro-oculography (EOG) and visual evoked response (VER). The electrodiagnostic measurements were made usi...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/BF03178360
更新日期:2001-09-01 00:00:00
abstract::Fractal dimension has been proposed as a useful method for characterizing medical images. The fractal dimension is calculated from the average radial power spectrum of the image. However, simpler methods of calculation have been proposed. This paper examines a very simple and easily implemented method which has been p...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1991-09-01 00:00:00
abstract::Mitral stenosis (MS) and mitral insufficiency (MI) have different pre-operative hemodynamic characteristics. However, it is unclear if there are differences in long-term echocardiographic characteristics of MS and MI patients after mechanical mitral valve replacement. This study is to compare long-term echocardiograph...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-016-0521-3
更新日期:2017-03-01 00:00:00
abstract::At present, the Australasian College of Physical Scientists and Engineers in Medicine does not support the practice of self-referred whole-body CT screening of asymptomatic patients because: The procedure involves a non-trivial radiation dose, which assumes even greater significance in the context of an ongoing screen...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 指南,杂志文章
doi:10.1007/BF03178880
更新日期:2004-03-01 00:00:00
abstract::The Australian Clinical Dosimetry Service (ACDS) has demonstrated the capacity to perform a basic dosimetry audit on all radiotherapy clinics across Australia. During the ACDS's three and a half year trial the majority of the audits were performed using optically stimulated luminescence dosimeters (OSLD) mailed to fac...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-014-0320-7
更新日期:2015-03-01 00:00:00
abstract::The purpose of this paper is to describe an outline of a proton therapy system in Nagoya Proton Therapy Center (NPTC). The NPTC has a synchrotron with a linac injector and three treatment rooms: two rooms are equipped with a gantry and the other one is equipped with a fixed horizontal beamline. One gantry treatment ro...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-016-0456-8
更新日期:2016-09-01 00:00:00
abstract::Post installation acceptance testing is vital to demonstrate that the equipment meets the vendor's specification and is suitable for clinical studies. The test procedures described in the NEMA NU 2-2001 document form the basis of vendor performance specifications of PET scanners and hence are also appropriate for acce...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-010-0016-6
更新日期:2010-06-01 00:00:00
abstract::Diamond detectors are particularly well suited for dosimetry applications in radiotherapy for reasons including near-tissue equivalence and high-spatial resolution resulting from small sensitive volumes. However, these detectors have not become commonplace due to high cost and poor availability arising from the need f...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-010-0040-6
更新日期:2010-12-01 00:00:00