Singular value based characterization and analysis of thermal patches for early breast abnormality detection.

Abstract:

:The purpose of this study is to develop a novel breast abnormality detection system by utilizing the potential of infrared breast thermography (IBT) in early breast abnormality detection. Since the temperature distributions are different in normal and abnormal thermograms and hot thermal patches are visible in abnormal thermograms, the abnormal thermograms possess more complex information than the normal thermograms. Here, the proposed method exploits the presence of hot thermal patches and vascular changes by using the power law transformation for pre-processing and singular value decomposition to characterize the thermal patches. The extracted singular values are found to be statistically significant (p < 0.001) in breast abnormality detection. The discriminability of the singular values is evaluated by using seven different classifiers incorporating tenfold cross-validations, where the thermograms of the Department of Biotechnology-Tripura University-Jadavpur University (DBT-TU-JU) and Database of Mastology Research (DMR) databases are used. In DMR database, the highest classification accuracy of 98.00% with the area under the ROC curve (AUC) of 0.9862 is achieved with the support vector machine using polynomial kernel. The same for the DBT-TU-JU database is 92.50% with AUC of 0.9680 using the same classifier. The comparison of the proposed method with the other reported methods concludes that the proposed method outperforms the other existing methods as well as other traditional feature sets used in IBT based breast abnormality detection. Moreover, by using Rank1 and Rank2 singular values, a breast abnormality grading (BAG) index has also been developed for grading the thermograms based on their degree of abnormality.

authors

Gogoi UR,Bhowmik MK,Bhattacharjee D,Ghosh AK

doi

10.1007/s13246-018-0681-4

subject

Has Abstract

pub_date

2018-12-01 00:00:00

pages

861-879

issue

4

eissn

0158-9938

issn

1879-5447

pii

10.1007/s13246-018-0681-4

journal_volume

41

pub_type

杂志文章
  • ACPSEM ROSG Oncology-PACS and OIS working group recommendations for quality assurance.

    abstract::The Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) Radiation Oncology Specialty Group (ROSG) formed a series of working groups in 2011 to develop position papers for guidance of radiation oncology medical physics practice within the Australasian setting. These position papers are intend...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-013-0238-5

    authors: Shakeshaft J,Perez M,Tremethick L,Ceylan A,Bailey M

    更新日期:2014-03-01 00:00:00

  • Monte Carlo simulation of the RBE of I-131 radiation using DNA damage as biomarker.

    abstract::In general, a weighting factor of one is applied for low linear energy transfer radiations. However, several studies indicate that relative biological effectiveness (RBE) of low energy photons and electrons is greater than one. The aim of this current study was calculating the RBE of I-131 radiation relative to Co-60 ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-017-0544-4

    authors: Ezzati AO,Mahmoud-Pashazadeh A,Studenski MT

    更新日期:2017-06-01 00:00:00

  • Continuous physiological monitoring: an integrated system for use in neonatal intensive care.

    abstract::A general purpose, multi-channel digital data acquisition and analysis system (Amlab, Associative Measurements, Sydney) configured to collect and process physiological signals including electroencephalograph and blood pressure is described. Its advantages over analog and single-purpose instrumentation are discussed as...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Hall GL,Colditz PB

    更新日期:1995-09-01 00:00:00

  • The clinical value of ophthalmic electrodiagnosis in children.

    abstract::A group of 113 children with poor vision who had been referred to the Electrodiagnostic Clinic over a five year period were investigated for disease of the retina and optic pathway by electroretinography (ERG), electro-oculography (EOG) and visual evoked response (VER). The electrodiagnostic measurements were made usi...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178360

    authors: Hidajat RR,Goode DH

    更新日期:2001-09-01 00:00:00

  • An application of linear output error modelling for studying lymphocyte migration in peripheral lymphoid tissues.

    abstract::Lymphocyte recirculation between lymphatic and blood vessels and migration through tissues are essential mechanisms underlying immunological surveillance. However, the kinetics of lymphocyte migration through lymphoid tissues remains poorly understood. The present study of lymphocyte migration, based on a sheep model ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178774

    authors: Srikusalanukul W,De Bruyne F,McCullagh P

    更新日期:2002-09-01 00:00:00

  • Depth of anaesthesia assessment based on adult electroencephalograph beta frequency band.

    abstract::This paper presents a new method to apply timing characteristics of electroencephalograph (EEG) beta frequency bands to assess the depth of anaesthesia (DoA). Firstly, the measured EEG signals are denoised and decomposed into 20 different frequency bands. The Mobility (M), permutation entropy (PE) and Lempel-Ziv compl...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-016-0459-5

    authors: Li T,Wen P

    更新日期:2016-09-01 00:00:00

  • Photon buildup in orthovoltage X-ray beams.

    abstract::Orthovoltage x-ray beams exhibit the characteristic of depth dose buildup which is not well described in the literature. The principal reason for this phenomenon is the increase in dose deposited due to electrons set in motion by secondary (Compton) scattered photons within the phantom, as depth is increased until lon...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Hill RF,Keall PJ,Beckham WA,Perez MD

    更新日期:1998-06-01 00:00:00

  • A rapid compression technique for 4-D functional MRI images using data rearrangement and modified binary array techniques.

    abstract::Compression techniques are vital for efficient storage and fast transfer of medical image data. The existing compression techniques take significant amount of time for performing encoding and decoding and hence the purpose of compression is not fully satisfied. In this paper a rapid 4-D lossy compression method constr...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0385-y

    authors: Uma Vetri Selvi G,Nadarajan R

    更新日期:2015-12-01 00:00:00

  • Evaluation of EBT radiochromic film using a multiple exposure technique.

    abstract::Radiochromic film is a self developing two-dimensional dosimeter system that is widely used in radiotherapy. Since its development some 40 years ago many improvements have been made; however the sensitivity can vary across the film and a non-linear dose response remains. The former can be addressed using a double expo...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-011-0067-3

    authors: Roozen K,Kron T,Haworth A,Franich R

    更新日期:2011-06-01 00:00:00

  • Software tool for portal dosimetry research.

    abstract::This paper describes a software tool developed for research into the use of an electronic portal imaging device (EPID) to verify dose for intensity modulated radiation therapy (IMRT) beams. A portal dose image prediction (PDIP) model that predicts the EPID response to IMRT beams has been implemented into a commerciall...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03179347

    authors: Vial P,Hunt P,Greer PB,Oliver L,Baldock C

    更新日期:2008-09-01 00:00:00

  • The calibration of plane parallel ionisation chambers for the measurement of absorbed dose in electron beams of low to medium energies. Part 1: the NACP chamber.

    abstract::A study was made of calibrating the NACP plane parallel chamber in electron beams from linear accelerators of a different manufacture with energies, Ep,o' from 4.4 to 19.1 MeV, and also in 4 and 6 MV photon beams as well as a cobalt60 beam. The photon beam measurements were both IN-AIR and IN-PHANTOM. With the excepti...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Cross P,Freeman N

    更新日期:1996-09-01 00:00:00

  • Comparison of 192Ir air kerma calibration coefficients derived at ARPANSA using the interpolation method and at the National Physical Laboratory using a direct measurement.

    abstract::The reference air kerma rate from 192Ir High Dose Rate (HDR) brachytherapy sources can be measured using a suitably calibrated Farmer chamber and an appropriate in-air calibration jig. When a primary standard for 192Ir gamma rays is available, a calibration coefficient for the chamber and jig combination can be determ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178603

    authors: Butler D,Haworth A,Sander T,Todd S

    更新日期:2008-12-01 00:00:00

  • Biomathematical modelling of physiological fluids using a Casson fluid with emphasis to peristalsis.

    abstract::In this paper, the peristaltic flow of rheologically complex physiological fluids when modelled by a non-Newtonian Casson fluid in a two-dimensional channel is considered. Of interest is the difference between peristaltic transport of Newtonian and non-Newtonian fluids. A perturbation series method of solution of the ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Mernone AV,Mazumdar JN

    更新日期:2000-09-01 00:00:00

  • Comparison of natural and synthetic diamond X-ray detectors.

    abstract::Diamond detectors are particularly well suited for dosimetry applications in radiotherapy for reasons including near-tissue equivalence and high-spatial resolution resulting from small sensitive volumes. However, these detectors have not become commonplace due to high cost and poor availability arising from the need f...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-010-0040-6

    authors: Lansley SP,Betzel GT,Metcalfe P,Reinisch L,Meyer J

    更新日期:2010-12-01 00:00:00

  • Development of a method for manufacturing customized nasal mask cushion for CPAP therapy.

    abstract::A continuous positive airway pressure (CPAP) device is considered one of the most effective treatments for obstructive sleep apnea (OSA). However, many patients receiving this treatment complain of mask discomfort and other issues. Therefore, this study aimed to develop a customized nasal mask cushion to reduce the di...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0383-0

    authors: Hsu DY,Cheng YL,Bien MY,Lee HC

    更新日期:2015-12-01 00:00:00

  • Characterization of a Fricke dosimeter at high energy photon and electron beams used in radiotherapy.

    abstract::The dosimetric features of the Fricke dosimeter in clinical linear accelerator beams are considered. Experimental data were obtained using various nominal energies 6 and 18 MV, 12 and 15 MeV, including the (60)Co γ-ray beam. The calibration of the dosimeters was performed using the ionization chamber as a reference do...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-011-0093-1

    authors: Moussous O,Khoudri S,Benguerba M

    更新日期:2011-12-01 00:00:00

  • Fluid structure interaction (FSI) simulation of the left ventricle (LV) during the early filling wave (E-wave), diastasis and atrial contraction wave (A-wave).

    abstract::In this paper, the hemodynamic characteristics inside a physiologically correct three-dimensional LV model using fluid structure interaction scheme are examined under various heart beat conditions during early filling wave (E-wave), diastasis and atrial contraction wave (A-wave). The time dependent and incompressible ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-014-0250-4

    authors: Arefin MS,Morsi YS

    更新日期:2014-06-01 00:00:00

  • Expected and observed changes to descriptors of trabecular architecture with aging--a comparison of measurement techniques.

    abstract::The fragility of trabecular bone depends not only on the amount of bone but also on its architecture. In order to assess fragility of bone, describe changes due to age, and monitor effect of disease or treatment, it is necessary to model the physical properties of trabecular bone architecture. An important feature of ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Badiei A,Bottema MJ,Fazzalari NL

    更新日期:2006-03-01 00:00:00

  • Experimental and numerical study on the hemodynamics of stenosed carotid bifurcation.

    abstract::Numerical simulation is performed to demonstrate that hemodynamic factors are significant determinants for the development of a vascular pathology. Experimental measurements by particle image velocimetry are carried out to validate the credibility of the computational approach. We present a study for determining compl...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-010-0050-4

    authors: Cheung SC,Wong KK,Yeoh GH,Yang W,Tu J,Beare R,Phan T

    更新日期:2010-12-01 00:00:00

  • Indices from lagged poincare plots of heart rate variability: an efficient nonlinear tool for emotion discrimination.

    abstract::Interest in human emotion recognition, regarding physiological signals, has recently risen. In this study, an efficient emotion recognition system, based on geometrical analysis of autonomic nervous system signals, is presented. The electrocardiogram recordings of 47 college students were obtained during rest conditio...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-017-0530-x

    authors: Goshvarpour A,Abbasi A,Goshvarpour A

    更新日期:2017-06-01 00:00:00

  • Effects of inaccurate small field dose measurements on calculated treatment doses.

    abstract::Given the difficulty and potential time- or financial-costs associated with accurate small field dosimetry, this study aimed to establish the clinical necessity of obtaining accurate small field output factor measurements and to evaluate the effects on planned doses that could arise if accurate measurements are not us...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-016-0461-y

    authors: Kairn T,Charles P,Crowe SB,Trapp JV

    更新日期:2016-09-01 00:00:00

  • An assessment on the use of RadCalc to verify Raystation Electron Monte Carlo plans.

    abstract::Large differences in monitor units have been observed when RadCalc, a pencil-beam-algorithm based software, is used to verify clinical electron plans from Raystation, a Monte-Carlo-algorithm based planning system. To investigate the problem, a number of clinical plans as well as test plans were created and calculated ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-016-0470-x

    authors: Hu Y,Archibald-Heeren B,Byrne M,Wang Y

    更新日期:2016-09-01 00:00:00

  • An investigation into lung correction for tangential breast irradiation.

    abstract::A solid water breast phantom with a lung equivalent material was constructed to investigate interface effects of 6 MV tangential photon fields. The phantom was built so that Thermo-luminescence Dosimeters (TLD) could be used for comparison to a pencil beam and Equivalent Tissue-Air-Ratio (ETAR) algorithms. The investi...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Hill B,Brown R

    更新日期:1998-03-01 00:00:00

  • Effects of visual and cognitive interference on joint contributions in perturbed standing: a temporal and spectral analysis.

    abstract::Postural balance requires using joint strategies which may be changed from normal conditions by interfering with the sensory information. The goal of the present study was to quantitatively evaluate the role of the joint mechanisms during perturbed stance. Visual and cognitive interference was imposed to sixteen healt...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-017-0606-7

    authors: Ashtiani MN,Azghani MR

    更新日期:2018-03-01 00:00:00

  • Stereotactic dose perturbation from an aneurysm clip measured by Gafchromic EBT film.

    abstract::Aneurysm clips within stereotactic treatment volumes enhance spatial accuracy but perturb the dose distribution. The dose perturbations caused by a standard titanium alloy aneurysm clip (Ti6Al4V) have been measured with Gafchromic EBT film. The maximum dose perturbation was an increase of 6 % within 0.5 mm of the beam...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178449

    authors: He CF,Geso M,Ackerly T,Wong CJ

    更新日期:2008-03-01 00:00:00

  • Neuro-muscular junction block stimulator simulator.

    abstract::Improved technology and higher fidelity are making medical simulations increasingly popular. A simulated peripheral nerve stimulator and thumb actuator has been developed for use with the SimMan Universal Patient Simulator. This device incorporates a handheld control box, a McKibben pneumatic muscle and articulated th...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Sprick C

    更新日期:2006-03-01 00:00:00

  • An investigation of central axis depth dose distribution perturbation due to an air gap between patient and bolus for electron beams.

    abstract::Electron beams can be used for the radiotherapy treatment of superficial cancers. In many cases of electron beam radiotherapy, tissue equivalent bolus material placed on the skin is to be used to enhance skin dose. An air gap might be present between the bolus and the skin due to variation in the patient contour. The ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178415

    authors: Kong M,Holloway L

    更新日期:2007-06-01 00:00:00

  • Optimal selection of mother wavelet for accurate infant cry classification.

    abstract::Wavelet theory is emerging as one of the prevalent tool in signal and image processing applications. However, the most suitable mother wavelet for these applications is still a relative question mark amongst researchers. Selection of best mother wavelet through parameterization leads to better findings for the analysi...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-014-0264-y

    authors: Saraswathy J,Hariharan M,Nadarajaw T,Khairunizam W,Yaacob S

    更新日期:2014-06-01 00:00:00

  • NEMA NU 2-2001 performance testing of a Philips Gemini GXL PET/CT scanner.

    abstract::Post installation acceptance testing is vital to demonstrate that the equipment meets the vendor's specification and is suitable for clinical studies. The test procedures described in the NEMA NU 2-2001 document form the basis of vendor performance specifications of PET scanners and hence are also appropriate for acce...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-010-0016-6

    authors: Sathiakumar C,Som S,Eberl S,Lin P

    更新日期:2010-06-01 00:00:00

  • Evaluation of effective energy for QA and QC: measurement of half-value layer using radiochromic film density.

    abstract::The effective energy of diagnostic X-rays is important for quality assurance (QA) and quality control (QC). However, the half-value layer (HVL), which is necessary to evaluate the effective energy, is not ubiquitously monitored because ionization-chamber dosimetry is time-consuming and complicated. To verify the appli...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178625

    authors: Gotanda T,Katsuda T,Gotanda R,Tabuchi A,Yamamoto K,Kuwano T,Yatake H,Takeda Y

    更新日期:2009-03-01 00:00:00