Abstract:
:A solid water breast phantom with a lung equivalent material was constructed to investigate interface effects of 6 MV tangential photon fields. The phantom was built so that Thermo-luminescence Dosimeters (TLD) could be used for comparison to a pencil beam and Equivalent Tissue-Air-Ratio (ETAR) algorithms. The investigation highlighted the limitations in both of these algorithms under clinically anatomical conditions. At the lung/tissue interface both algorithms showed errors between 3-12% depending on the position of the TLD. In tissue greater than 1 cm from the interface region the errors on average were within +/- 5%. Dose comparisons in lung tissue showed similar results to the interface region. These results indicate that normalisation of Reference Dose in the interface region for tangential breast treatments cause over or under estimates of dose.
journal_name
Australas Phys Eng Sci Medjournal_title
Australasian physical & engineering sciences in medicineauthors
Hill B,Brown Rsubject
Has Abstractpub_date
1998-03-01 00:00:00pages
24-8issue
1eissn
0158-9938issn
1879-5447journal_volume
21pub_type
杂志文章abstract::The computed tomography (CT) imaging artefacts that metallic medical implants produce in surrounding tissues are usually contoured and over-ridden during radiotherapy treatment planning. In cases where radiotherapy treatment beams unavoidably pass though implants, it is especially important to understand the imaging a...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-013-0197-x
更新日期:2013-06-01 00:00:00
abstract::Surface, build-up and depth dose characteristics of a monoenergetic electron point source simulated by Monte Carlo code MCNP4c for varying field size and SSD are extensively studied in this paper. MCNP4c (Monte Carlo N-Particle Transport Code System) has been extensively used in clinical dose simulation for its versat...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/BF03178652
更新日期:2004-12-01 00:00:00
abstract::Accelerator neutron sources for epithermal neutron capture therapy utilising the 7Li(p,n) nuclear reaction are proposed to operate in the range of 1.88 to 2.5 MeV proton energy. Operation with proton energies closer to the reaction threshold decreases neutron yield but allows for smaller reflector and moderator, with ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1998-12-01 00:00:00
abstract::A set of computer programs to simulate diagnostic x-ray spectra has been developed according to the method of Birch and Marshall, with good agreement to published HPA data. These programs have been extended to simulate spectra generated with capacitor discharge x-ray units. The application of these programs has proved...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1989-09-01 00:00:00
abstract::Postural balance requires using joint strategies which may be changed from normal conditions by interfering with the sensory information. The goal of the present study was to quantitatively evaluate the role of the joint mechanisms during perturbed stance. Visual and cognitive interference was imposed to sixteen healt...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-017-0606-7
更新日期:2018-03-01 00:00:00
abstract::The Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) Radiation Oncology Specialty Group (ROSG) formed a series of working groups in 2011 to develop position papers for guidance of radiation oncology medical physics practice within the Australasian setting. These position papers are intend...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-013-0238-5
更新日期:2014-03-01 00:00:00
abstract::Transmission data for a fibre cement wallboard (villaboard) are determined for use in diagnostic shielding designs. Villaboard is found to be more attenuating than plasterboard e.g. 9 mm of villaboard is equivalent to 16 mm of plasterboard. ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1998-09-01 00:00:00
abstract::Accuracy of dwell position and reproducibility of dwell time are critical in high dose rate (HDR) brachytherapy. A phantom was designed to verify dwell position and dwell time reproducibility for an Ir-192 HDR stepping source using Computed Radiography (CR). The central part of the phantom, incorporating thin alternat...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-012-0138-0
更新日期:2012-09-01 00:00:00
abstract::Improved technology and higher fidelity are making medical simulations increasingly popular. A simulated peripheral nerve stimulator and thumb actuator has been developed for use with the SimMan Universal Patient Simulator. This device incorporates a handheld control box, a McKibben pneumatic muscle and articulated th...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:2006-03-01 00:00:00
abstract::The reference air kerma rate from 192Ir High Dose Rate (HDR) brachytherapy sources can be measured using a suitably calibrated Farmer chamber and an appropriate in-air calibration jig. When a primary standard for 192Ir gamma rays is available, a calibration coefficient for the chamber and jig combination can be determ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/BF03178603
更新日期:2008-12-01 00:00:00
abstract::In recent years, the use of gold nanoparticles in radiation therapy has been introduced as a new approach in radiotherapy. The aim of this study is to investigate the effect of gold nanoparticles (GNPs) in plaque brachytherapy for choroidal melanoma using Monte Carlo (MC) simulation. MCNPX code was used for simulation...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-017-0555-1
更新日期:2017-09-01 00:00:00
abstract::Two software packages designed for automatic counting nuclear tracks are tested and compared. The image processing in the first package is divided into three parts segmentation, speckle elimination and removal of ill-formed track holes. The second package is also divided into three parts but the last part is modified ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1992-06-01 00:00:00
abstract::It has long been recognized that the assessment of Automatic Exposure Control (AEC) function is an important criterion in the assessment of any general radiographic x-ray installation. Of the tests commonly performed on an AEC, only Beam Quality Dependence relates intimately with the optical density produced on the re...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1997-09-01 00:00:00
abstract::Laparoscopic ultrasound (LUS) has been widely utilized as a surgical aide in general, urological, and gynecological applications. Our study summarizes the clinical applications of laparoscopic ultrasonography in laparoscopic gynecologic surgery. Retrospective analyses were performed on 42 women subjects using laparosc...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-015-0363-4
更新日期:2015-12-01 00:00:00
abstract::The aim of this study was to determine whether there is an effect of mobile phone electromagnetic field emissions on the human electroencephalograph (EEG). EEG recordings from ten awake subjects were taken during exposure to radiofrequency (RF) emissions from a mobile phone positioned behind the head. Two experimental...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1007/BF03179176
更新日期:2003-12-01 00:00:00
abstract::Currently, a software-based second check dose calculation for helical tomotherapy (HT) is not available. The goal of this study is to evaluate the dose calculation accuracy of the in-house software using EGS4/MCSIM Monte Carlo environment against the treatment planning system calculations. In-house software was used t...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-012-0165-x
更新日期:2012-12-01 00:00:00
abstract::The Resonant Recognition Model (rrm) uses digital signal processing methods to investigate protein structure-function; and links the biological function of protein families to unique characteristic frequencies. The rrm originally used a single set of variables: the electron ion interaction potential (EIIP). Here the r...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1995-12-01 00:00:00
abstract::AFOMP recognizes that clinical medical physicists should demonstrate that they are competent to practice their profession by obtaining appropriate education, training and supervised experience in the specialties of medical physics in which they practice, as well as having a basic knowledge of other specialties. To hel...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章,评审
doi:10.1007/s13246-011-0091-3
更新日期:2011-09-01 00:00:00
abstract::The purpose of this paper is to describe an outline of a proton therapy system in Nagoya Proton Therapy Center (NPTC). The NPTC has a synchrotron with a linac injector and three treatment rooms: two rooms are equipped with a gantry and the other one is equipped with a fixed horizontal beamline. One gantry treatment ro...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-016-0456-8
更新日期:2016-09-01 00:00:00
abstract::Calculations have been performed of the kerma to radiographic film and to silicon from a number of x-ray spectra generated at 30 to 140 kV with tungsten and molybdenum targets. These results have been compared with the air-kerma values due to the same beams. It is concluded that both film and silicon can be used as pr...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1992-12-01 00:00:00
abstract::Electron beams can be used for the radiotherapy treatment of superficial cancers. In many cases of electron beam radiotherapy, tissue equivalent bolus material placed on the skin is to be used to enhance skin dose. An air gap might be present between the bolus and the skin due to variation in the patient contour. The ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/BF03178415
更新日期:2007-06-01 00:00:00
abstract::At present, the Australasian College of Physical Scientists and Engineers in Medicine does not support the practice of self-referred whole-body CT screening of asymptomatic patients because: The procedure involves a non-trivial radiation dose, which assumes even greater significance in the context of an ongoing screen...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 指南,杂志文章
doi:10.1007/BF03178880
更新日期:2004-03-01 00:00:00
abstract::Most of the human head models used in dipole localisation research, which have been reported in the literature to date, assume a simplified cranial structure wherein the head is modelled as a set of distinct homogenous tissue compartments. The inherent inhomogeneity of the tissues has so far been ignored in these mode...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/BF03178283
更新日期:2001-03-01 00:00:00
abstract::A new era has arrived for the Biomedical Engineering Department at the Royal Women's Hospital in Melbourne. We have developed a system to qualitatively test for intermittent or unconfirmed faults, associated with Bear Cub ventilators. Where previous testing has been inadequate, computer logging is now used to interfac...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1994-06-01 00:00:00
abstract::Rotary blood pumps have the potential to become a viable long-term treatment option for the heart failure patients to bridge to transplantation or destination therapy. However, these devices operate at a constant speed which may lead to long term complications or they may operate in an undesired support mode such as e...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章,评审
doi:10.1007/s13246-015-0405-y
更新日期:2016-03-01 00:00:00
abstract::The accuracy of a computed tomography (CT)-relative electron density (RED) curve may have an indirect impact on the accuracy of dose calculation by a treatment planning system (TPS). This effect has not been previously quantified for input of different CT-RED curves from different CT-scan units in the Monaco TPS. This...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-019-00745-6
更新日期:2019-06-01 00:00:00
abstract::The fragility of trabecular bone depends not only on the amount of bone but also on its architecture. In order to assess fragility of bone, describe changes due to age, and monitor effect of disease or treatment, it is necessary to model the physical properties of trabecular bone architecture. An important feature of ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:2006-03-01 00:00:00
abstract::In this paper, the hemodynamic characteristics inside a physiologically correct three-dimensional LV model using fluid structure interaction scheme are examined under various heart beat conditions during early filling wave (E-wave), diastasis and atrial contraction wave (A-wave). The time dependent and incompressible ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-014-0250-4
更新日期:2014-06-01 00:00:00
abstract::It was the aim of this work to assess and track the workload, working conditions and professional recognition of radiation oncology medical physicists (ROMPs) in the Asia Pacific region over time. In this third survey since 2008, a structured questionnaire was mailed in 2014 to 22 senior medical physicists representin...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-015-0373-2
更新日期:2015-09-01 00:00:00
abstract::Thermoluminescence dosimetry (TLD) is a versatile tool for the assessment of dose from ionising radiation. The wide variety of TLD materials and their different physical forms allow the determination of different radiation qualities at dose levels from microGy to kGy. Major advantages of TL dosimeters are their small ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章,评审
doi:
更新日期:1994-12-01 00:00:00