Determination of correct AEC function with computed radiography cassettes.

Abstract:

:It has long been recognized that the assessment of Automatic Exposure Control (AEC) function is an important criterion in the assessment of any general radiographic x-ray installation. Of the tests commonly performed on an AEC, only Beam Quality Dependence relates intimately with the optical density produced on the resultant radiograph. In this test the AEC function is ascertained as being satisfactory or otherwise, on the basis of whether the optical density on the radiograph is controlled within well defined limits. With computed radiography (CR), where the conventional screen-film combination is replaced by a storage phosphor screen, the process by which the digital image is presented on film restricts the resultant optical densities to an extremely tight range, independent of the air kerma incident upon the CR phosphor plate. The implication of this is that the measurement of optical density can not be used as a direct measure of AEC function, and a test such as Beam Quality Dependence cannot be performed in the conventional manner. To overcome this, the relationship between incident air kerma and a computer generated index supplied with the CR system was investigated for two commercially available systems, one supplied by Fuji Medical Systems and the other by Kodak. The relationship between the index and incident air kerma could then be used as a substitute for optical density in monitoring AEC performance with respect to beam quality. It has been determined that an inverse linear relationship exists between the incident air kerma and the Sensitivity Number for the Fuji CR system and that a logarithmic relationship exists between the Exposure Index and incident air kerma for the Kodak CR system. In order to quantify these relationships further, the dependence of Sensitivity Number and Exposure Index on beam quality and incident kVp have been investigated. Using the results from the above investigations, acceptable limits for both Sensitivity Number and Exposure Index, can be established to test for correct AEC function, with respect to Beam Quality Dependence.

authors

Wilkinson LE,Heggie JC

subject

Has Abstract

pub_date

1997-09-01 00:00:00

pages

186-91

issue

3

eissn

0158-9938

issn

1879-5447

journal_volume

20

pub_type

杂志文章
  • Influence of normalization and color features on super-pixel classification: application to cytological image segmentation.

    abstract::Super-pixel feature extraction is a key problem to get an acceptable performance in color super-pixel classification. Given a color feature extraction problem, it is necessary to know which is the best approach to solve this problem. In the current work, we're interested in the challenge of nucleus and cytoplasm autom...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-019-00735-8

    authors: Bechar MEA,Settouti N,Daho MEH,Adel M,Chikh MA

    更新日期:2019-06-01 00:00:00

  • Position paper: recommendations for a digital mammography quality assurance program V4.0.

    abstract::In 2001 the ACPSEM published a position paper on quality assurance in screen film mammography which was subsequently adopted as a basis for the quality assurance programs of both the Royal Australian and New Zealand College of Radiologists (RANZCR) and of BreastScreen Australia. Since then the clinical implementation ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-017-0583-x

    authors: Heggie JCP,Barnes P,Cartwright L,Diffey J,Tse J,Herley J,McLean ID,Thomson FJ,Grewal RK,Collins LT

    更新日期:2017-09-01 00:00:00

  • Effects of treatment distance and field size on build-up characteristics of Monte Carlo calculated absorbed dose for electron irradiation.

    abstract::Surface, build-up and depth dose characteristics of a monoenergetic electron point source simulated by Monte Carlo code MCNP4c for varying field size and SSD are extensively studied in this paper. MCNP4c (Monte Carlo N-Particle Transport Code System) has been extensively used in clinical dose simulation for its versat...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178652

    authors: Lin H,Wu DS,Wu AD

    更新日期:2004-12-01 00:00:00

  • Hidden pattern discovery on epileptic EEG with 1-D local binary patterns and epileptic seizures detection by grey relational analysis.

    abstract::This paper proposes a novel approach to detect epilepsy seizures by using Electroencephalography (EEG), which is one of the most common methods for the diagnosis of epilepsy, based on 1-Dimension Local Binary Pattern (1D-LBP) and grey relational analysis (GRA) methods. The main aim of this paper is to evaluate and val...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0362-5

    authors: Kaya Y

    更新日期:2015-09-01 00:00:00

  • Multi-layer cube sampling for liver boundary detection in PET-CT images.

    abstract::Liver metabolic information is considered as a crucial diagnostic marker for the diagnosis of fever of unknown origin, and liver recognition is the basis of automatic diagnosis of metabolic information extraction. However, the poor quality of PET and CT images is a challenge for information extraction and target recog...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-018-0650-y

    authors: Liu X,Yang J,Song S,Song H,Ai D,Zhu J,Jiang Y,Wang Y

    更新日期:2018-06-01 00:00:00

  • Development of a biological signal-based evaluator for robot-assisted upper-limb rehabilitation: a pilot study.

    abstract::Bio-signal based assessment for upper-limb functions is an attractive technology for rehabilitation. In this work, an upper-limb function evaluator is developed based on biological signals, which could be used for selecting different robotic training protocols. Interaction force (IF) and participation level (PL, proce...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-019-00783-0

    authors: Sheng B,Tang L,Moosman OM,Deng C,Xie S,Zhang Y

    更新日期:2019-09-01 00:00:00

  • Characterization of a Fricke dosimeter at high energy photon and electron beams used in radiotherapy.

    abstract::The dosimetric features of the Fricke dosimeter in clinical linear accelerator beams are considered. Experimental data were obtained using various nominal energies 6 and 18 MV, 12 and 15 MeV, including the (60)Co γ-ray beam. The calibration of the dosimeters was performed using the ionization chamber as a reference do...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-011-0093-1

    authors: Moussous O,Khoudri S,Benguerba M

    更新日期:2011-12-01 00:00:00

  • Computer-aided diagnosis system for classifying benign and malignant thyroid nodules in multi-stained FNAB cytological images.

    abstract::An automated computer-aided diagnosis system is developed to classify benign and malignant thyroid nodules using multi-stained fine needle aspiration biopsy (FNAB) cytological images. In the first phase, the image segmentation is performed to remove the background staining information and retain the appropriate foregr...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-013-0199-8

    authors: Gopinath B,Shanthi N

    更新日期:2013-06-01 00:00:00

  • Polymer gel dosimeters with PVA-GA matrix.

    abstract::Properties of a new polymer gel with cross-linked polyvinyl alcohol as a gelatinous matrix were investigated. The new polymer gel dosimeter was named PVABAT. The irradiation was performed using a calibrated 60Co beam. The dose responses of the PVABAT formulations were quantified with MRI transverse relaxation rate (R2...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-017-0573-z

    authors: Abtahi SMM,Sadeghi Abandansari H

    更新日期:2017-09-01 00:00:00

  • Ozone, cloud, solar and UV-B levels at a low pollution, Southern Hemisphere, sub-tropical site for winter/spring 1995.

    abstract::This paper analyses daily ozone, cloud cover, solar radiation and broadband UV-B data for winter/spring at a low pollution Southern Hemispheric sub-tropical site (27.80 degrees S). The average ozone concentration for the period was 290 DU. An anti-correlation is presented between the ozone and UV-B data over a 5 day p...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Sabburg J,Parisi A,Wong J

    更新日期:1997-12-01 00:00:00

  • Response of air, silicon and dosimetric films to x-ray spectra of various qualities.

    abstract::Calculations have been performed of the kerma to radiographic film and to silicon from a number of x-ray spectra generated at 30 to 140 kV with tungsten and molybdenum targets. These results have been compared with the air-kerma values due to the same beams. It is concluded that both film and silicon can be used as pr...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Paix D

    更新日期:1992-12-01 00:00:00

  • The linear accelerator mechanical and radiation isocentre assessment with an electronic portal imaging device (EPID).

    abstract::Regular checks on the performance of radiotherapy treatment units are essential and a variety of protocols has been published. These protocols identify that the determination of isocentre must be accurate and unambiguous since both the localization of a radiation field on a patient and positioning aids are referenced ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178670

    authors: Liu G,van Doorn T,Bezak E

    更新日期:2004-09-01 00:00:00

  • An assessment on the use of RadCalc to verify Raystation Electron Monte Carlo plans.

    abstract::Large differences in monitor units have been observed when RadCalc, a pencil-beam-algorithm based software, is used to verify clinical electron plans from Raystation, a Monte-Carlo-algorithm based planning system. To investigate the problem, a number of clinical plans as well as test plans were created and calculated ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-016-0470-x

    authors: Hu Y,Archibald-Heeren B,Byrne M,Wang Y

    更新日期:2016-09-01 00:00:00

  • Instruments to assess and measure personal and environmental radiofrequency-electromagnetic field exposures.

    abstract::Radiofrequency-electromagnetic field (RF-EMF) exposure of human populations is increasing due to the widespread use of mobile phones and other telecommunication and broadcasting technologies. There are ongoing concerns about potential short- and long-term public health consequences from RF-EMF exposures. To elucidate ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,评审

    doi:10.1007/s13246-015-0412-z

    authors: Bhatt CR,Redmayne M,Abramson MJ,Benke G

    更新日期:2016-03-01 00:00:00

  • Short tangential arcs in VMAT based breast and chest wall radiotherapy lead to conformity of the breast dose with lesser cardiac and lung doses: a prospective study of breast conservation and mastectomy patients.

    abstract::Volumetric modulated arc therapy (VMAT) is modern rotational intensity modulated therapy used for treatment of several sites. The study aimed to analyze partial tangential arc VMAT treatment planning and delivery, including analyzing the cardiac and contralateral breast doses resulting from this technique. A total of ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-017-0558-y

    authors: Munshi A,Sarkar B,Anbazhagan S,Giri UK,Kaur H,Jassal K,Ganesh T,Kalyan Mohanti B

    更新日期:2017-09-01 00:00:00

  • Performance of independent dose calculation in helical tomotherapy: implementation of the MCSIM code.

    abstract::Currently, a software-based second check dose calculation for helical tomotherapy (HT) is not available. The goal of this study is to evaluate the dose calculation accuracy of the in-house software using EGS4/MCSIM Monte Carlo environment against the treatment planning system calculations. In-house software was used t...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-012-0165-x

    authors: Dzintars E,Stathakis S,Mavroidis P,Sadeghi A,Papanikolaou N

    更新日期:2012-12-01 00:00:00

  • AFOMP Policy Statement No. 3: recommendations for the education and training of medical physicists in AFOMP countries.

    abstract::AFOMP recognizes that clinical medical physicists should demonstrate that they are competent to practice their profession by obtaining appropriate education, training and supervised experience in the specialties of medical physics in which they practice, as well as having a basic knowledge of other specialties. To hel...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,评审

    doi:10.1007/s13246-011-0091-3

    authors: Round WH,Ng KH,Healy B,Rodriguez L,Thayalan K,Tang F,Fukuda S,Srivastava R,Krisanachinda A,Shiau AC,Deng X,Han Y

    更新日期:2011-09-01 00:00:00

  • Comparison of methods for measuring fractal dimension.

    abstract::Fractal dimension has been proposed as a useful method for characterizing medical images. The fractal dimension is calculated from the average radial power spectrum of the image. However, simpler methods of calculation have been proposed. This paper examines a very simple and easily implemented method which has been p...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Bartlett ML

    更新日期:1991-09-01 00:00:00

  • Recent developments in radiation therapy planning and treatment optimization.

    abstract::Radiation therapy of cancer is today going through a very dynamic development with the introduction of a large number of new treatment principles, new types of treatment units and new radiobiologically based optimization algorithms for treatment planning. All of these make use of the recent developments in three dimen...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,评审

    doi:

    authors: Brahme A

    更新日期:1996-06-01 00:00:00

  • Investigating the impact of tumour motion on TomoTherapy stereotactic ablative body radiotherapy (SABR) deliveries on 3-dimensional and 4-dimensional computed tomography.

    abstract::TomoTherapy can provide highly accurate SABR deliveries, but currently it does not have any effective motion management techniques. Shallow breathing has been identified as one possible motion management solution on TomoTherapy, which has been made possible with the BreatheWell audiovisual biofeedback (AVB) device. Si...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-019-00727-8

    authors: Hu Y,Archibald-Heeren B,Byrne M,Cai E,Wang Y

    更新日期:2019-03-01 00:00:00

  • Management and autopsy of a radioactive cadaver.

    abstract::A 69 year old male was treated with an ablative dose of 3.7 GBq (100 mCi) of I131 for carcinoma of the thyroid and died 10 days after administration. The requirement for an autopsy and the level of radiation still present in the body necessitated the intervention of Radiation Safety Personnel to minimise support staff...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Wallace AB,Bush V

    更新日期:1991-06-01 00:00:00

  • A computer-assisted method for pathogenicity assessment and genetic reporting of variants stored in the Australian Inherited Retinal Disease Register.

    abstract::The assignment of pathogenicity to variants suspected of causing an inherited retinal disease and the subsequent creation of molecular genetic reports sent to clinical geneticists and ophthalmologists has traditionally been time-consuming and subject to error and ambiguity. The purpose of this paper is to describe a c...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0420-z

    authors: Huynh E,De Roach J,McLaren T,Thompson J,Montgomery H,Kap C,Hoffmann L,Lamey T

    更新日期:2016-03-01 00:00:00

  • Computer model to optimise contrast in chest radiography.

    abstract::X-ray imaging of the chest is challenging because of the large differences in x-ray attenuation between the mediastinal and lung regions of the chest. This large dynamic range of chest exit exposure, along with associated large changes in the scatter component of the beam, makes film based chest imaging difficult to o...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: McLean D

    更新日期:1993-12-01 00:00:00

  • A simulation study comparing nine mathematical models of arterial input function for dynamic contrast enhanced MRI to the Parker model.

    abstract::Due to large inter- and intra-patient variabilities of arterial input functions (AIFs), accurately modeling and using patient-specific AIF are very important for quantitative analysis of dynamic contrast enhanced MRI. Computer simulations were performed to evaluate and compare nine population AIF models with the Parke...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-018-0632-0

    authors: He D,Xu L,Qian W,Clarke J,Fan X

    更新日期:2018-06-01 00:00:00

  • The appearance and effects of metallic implants in CT images.

    abstract::The computed tomography (CT) imaging artefacts that metallic medical implants produce in surrounding tissues are usually contoured and over-ridden during radiotherapy treatment planning. In cases where radiotherapy treatment beams unavoidably pass though implants, it is especially important to understand the imaging a...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-013-0197-x

    authors: Kairn T,Crowe SB,Fogg P,Trapp JV

    更新日期:2013-06-01 00:00:00

  • The impact of smart metal artefact reduction algorithm for use in radiotherapy treatment planning.

    abstract::The presence of metal artefacts in computed tomography (CT) create issues in radiation oncology. The loss of anatomical information and incorrect Hounsfield unit (HU) values produce inaccuracies in dose calculations, providing suboptimal patient treatment. Metal artefact reduction (MAR) algorithms were developed to co...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-017-0543-5

    authors: Guilfoile C,Rampant P,House M

    更新日期:2017-06-01 00:00:00

  • A feature study of innovative high-speed lancing device and safety lancet.

    abstract::The study developed two models of an innovative high-speed lancing device and safety lancet, where the specially designed structure causes high-speed motion of the lancet, resulting in only one puncture of the skin. The two experimental models and other lancing devices sold on market were compared in order to: (1) mea...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-016-0490-6

    authors: Chang H,Yeh YJ,Lee R,Shyu JH

    更新日期:2016-12-01 00:00:00

  • An effective approach to classify epileptic EEG signal using local neighbor gradient pattern transformation methods.

    abstract::Electroencephalographic (EEG) signal records the neuronal activity in the brain and it is used in the diagnosis of epileptic seizure activities. Human inspection of non-stationary EEG signal for diagnosing epilepsy is cumbersome, time-consuming and inaccurate. In this paper an effective automatic approach to detect ep...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-018-0697-9

    authors: Sairamya NJ,Thomas George S,Balakrishnan R,Subathra MSP

    更新日期:2018-12-01 00:00:00

  • Medical physics aspects of cancer care in the Asia Pacific region: 2014 survey results.

    abstract::It was the aim of this work to assess and track the workload, working conditions and professional recognition of radiation oncology medical physicists (ROMPs) in the Asia Pacific region over time. In this third survey since 2008, a structured questionnaire was mailed in 2014 to 22 senior medical physicists representin...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0373-2

    authors: Kron T,Azhari HA,Voon EO,Cheung KY,Ravindran P,Soejoko D,Inamura K,Han Y,Ung NM,TsedenIsh B,Win UM,Srivastava R,Marsh S,Farrukh S,Rodriguez L,Kuo M,Baggarley S,DilipKumara AH,Lee CC,Krisanachinda A,Nguyen XC,Ng

    更新日期:2015-09-01 00:00:00

  • Indices from lagged poincare plots of heart rate variability: an efficient nonlinear tool for emotion discrimination.

    abstract::Interest in human emotion recognition, regarding physiological signals, has recently risen. In this study, an efficient emotion recognition system, based on geometrical analysis of autonomic nervous system signals, is presented. The electrocardiogram recordings of 47 college students were obtained during rest conditio...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-017-0530-x

    authors: Goshvarpour A,Abbasi A,Goshvarpour A

    更新日期:2017-06-01 00:00:00