Comparison of methods for measuring fractal dimension.

Abstract:

:Fractal dimension has been proposed as a useful method for characterizing medical images. The fractal dimension is calculated from the average radial power spectrum of the image. However, simpler methods of calculation have been proposed. This paper examines a very simple and easily implemented method which has been proposed for the calculation of fractal dimensions. Comparisons are made between the more rigorous method and the proposed simplification. It is found that the simpler method is a useful technique for calculating estimates of fractal dimension provided the range of dimensions of interest is small.

authors

Bartlett ML

subject

Has Abstract

pub_date

1991-09-01 00:00:00

pages

146-52

issue

3

eissn

0158-9938

issn

1879-5447

journal_volume

14

pub_type

杂志文章
  • A study on contralateral breast surface dose for various tangential field techniques and the impact of set-up error on this dose.

    abstract::The risk of inducing contralateral breast (CLB) cancer in patients undergoing tangential field irradiation for the treatment of breast cancer is a serious concern in radiation oncology. A bilateral breast phantom made of wax attached onto the Alderson Rando phantom was used for studying the CLB dose for techniques usi...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178408

    authors: Prabhakar R,Haresh KP,Julka PK,Ganesh T,Rath GK,Joshi RC,Sasindran M,Naik KK,Sridhar PS

    更新日期:2007-03-01 00:00:00

  • Using EGS4 Monte Carlo in medical radiation physics.

    abstract::Monte Carlo modelling of particle transport problems in medical radiation physics offers significant advantages over other techniques. Experiments can be performed without having to set up the physical situation, and "impossible" experiments can be performed, such as labelling multiple-scattered particles or simulatin...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type:

    doi:

    authors: Murray D

    更新日期:1990-09-01 00:00:00

  • The appearance and effects of metallic implants in CT images.

    abstract::The computed tomography (CT) imaging artefacts that metallic medical implants produce in surrounding tissues are usually contoured and over-ridden during radiotherapy treatment planning. In cases where radiotherapy treatment beams unavoidably pass though implants, it is especially important to understand the imaging a...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-013-0197-x

    authors: Kairn T,Crowe SB,Fogg P,Trapp JV

    更新日期:2013-06-01 00:00:00

  • Improved accuracy of 3D-printed navigational template during complicated tibial plateau fracture surgery.

    abstract::This study was aimed to improve the surgical accuracy of plating and screwing for complicated tibial plateau fracture assisted by 3D implants library and 3D-printed navigational template. Clinical cases were performed whereby complicated tibial plateau fractures were imaged using computed tomography and reconstructed ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0330-0

    authors: Huang H,Hsieh MF,Zhang G,Ouyang H,Zeng C,Yan B,Xu J,Yang Y,Wu Z,Huang W

    更新日期:2015-03-01 00:00:00

  • An investigation of central axis depth dose distribution perturbation due to an air gap between patient and bolus for electron beams.

    abstract::Electron beams can be used for the radiotherapy treatment of superficial cancers. In many cases of electron beam radiotherapy, tissue equivalent bolus material placed on the skin is to be used to enhance skin dose. An air gap might be present between the bolus and the skin due to variation in the patient contour. The ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178415

    authors: Kong M,Holloway L

    更新日期:2007-06-01 00:00:00

  • A computer-assisted method for pathogenicity assessment and genetic reporting of variants stored in the Australian Inherited Retinal Disease Register.

    abstract::The assignment of pathogenicity to variants suspected of causing an inherited retinal disease and the subsequent creation of molecular genetic reports sent to clinical geneticists and ophthalmologists has traditionally been time-consuming and subject to error and ambiguity. The purpose of this paper is to describe a c...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0420-z

    authors: Huynh E,De Roach J,McLaren T,Thompson J,Montgomery H,Kap C,Hoffmann L,Lamey T

    更新日期:2016-03-01 00:00:00

  • Evaluation of useful neutron flux for accelerator boron neutron capture therapy using the 7Li(p,n) reaction.

    abstract::Accelerator neutron sources for epithermal neutron capture therapy utilising the 7Li(p,n) nuclear reaction are proposed to operate in the range of 1.88 to 2.5 MeV proton energy. Operation with proton energies closer to the reaction threshold decreases neutron yield but allows for smaller reflector and moderator, with ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Zimin S,Allen BJ

    更新日期:1998-12-01 00:00:00

  • Continuous physiological monitoring: an integrated system for use in neonatal intensive care.

    abstract::A general purpose, multi-channel digital data acquisition and analysis system (Amlab, Associative Measurements, Sydney) configured to collect and process physiological signals including electroencephalograph and blood pressure is described. Its advantages over analog and single-purpose instrumentation are discussed as...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Hall GL,Colditz PB

    更新日期:1995-09-01 00:00:00

  • A rapid compression technique for 4-D functional MRI images using data rearrangement and modified binary array techniques.

    abstract::Compression techniques are vital for efficient storage and fast transfer of medical image data. The existing compression techniques take significant amount of time for performing encoding and decoding and hence the purpose of compression is not fully satisfied. In this paper a rapid 4-D lossy compression method constr...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0385-y

    authors: Uma Vetri Selvi G,Nadarajan R

    更新日期:2015-12-01 00:00:00

  • Glaucoma detection using novel optic disc localization, hybrid feature set and classification techniques.

    abstract::Glaucoma is a chronic and irreversible neuro-degenerative disease in which the neuro-retinal nerve that connects the eye to the brain (optic nerve) is progressively damaged and patients suffer from vision loss and blindness. The timely detection and treatment of glaucoma is very crucial to save patient's vision. Compu...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0377-y

    authors: Akram MU,Tariq A,Khalid S,Javed MY,Abbas S,Yasin UU

    更新日期:2015-12-01 00:00:00

  • Anatomical reduction and precise internal fixation of intra-articular fractures of the distal radius with virtual X-ray and 3D printing.

    abstract::To evaluate and precisely internal fix intra-articular distal radial fracture (IDRF) using the virtual X-ray and three-dimensional (3D) printing technologies. Twenty-one patients with IDRF were recruited, and the data from digital design group (DDG) and real surgery group (RSG) were collected and analyzed. In DDG, the...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-019-00795-w

    authors: Xu J,Zhang G,He Z,Zhong S,Chen Y,Wei C,Zheng Y,Lin H,Li W,Huang W

    更新日期:2019-10-22 00:00:00

  • Optimal selection of mother wavelet for accurate infant cry classification.

    abstract::Wavelet theory is emerging as one of the prevalent tool in signal and image processing applications. However, the most suitable mother wavelet for these applications is still a relative question mark amongst researchers. Selection of best mother wavelet through parameterization leads to better findings for the analysi...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-014-0264-y

    authors: Saraswathy J,Hariharan M,Nadarajaw T,Khairunizam W,Yaacob S

    更新日期:2014-06-01 00:00:00

  • Evaluation of automated image registration algorithm for image-guided radiotherapy (IGRT).

    abstract::The performance of an image registration (IR) software was evaluated for automatically detecting known errors simulated through the movement of ExactCouch using an onboard imager. Twenty-seven set-up errors (11 translations, 10 rotations, 6 translation and rotation) were simulated by introducing offset up to ± 15 mm i...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-012-0158-9

    authors: Sharma SD,Dongre P,Mhatre V,Heigrujam M

    更新日期:2012-09-01 00:00:00

  • Characterization of a Fricke dosimeter at high energy photon and electron beams used in radiotherapy.

    abstract::The dosimetric features of the Fricke dosimeter in clinical linear accelerator beams are considered. Experimental data were obtained using various nominal energies 6 and 18 MV, 12 and 15 MeV, including the (60)Co γ-ray beam. The calibration of the dosimeters was performed using the ionization chamber as a reference do...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-011-0093-1

    authors: Moussous O,Khoudri S,Benguerba M

    更新日期:2011-12-01 00:00:00

  • The clinical value of ophthalmic electrodiagnosis in children.

    abstract::A group of 113 children with poor vision who had been referred to the Electrodiagnostic Clinic over a five year period were investigated for disease of the retina and optic pathway by electroretinography (ERG), electro-oculography (EOG) and visual evoked response (VER). The electrodiagnostic measurements were made usi...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178360

    authors: Hidajat RR,Goode DH

    更新日期:2001-09-01 00:00:00

  • A proton therapy system in Nagoya Proton Therapy Center.

    abstract::The purpose of this paper is to describe an outline of a proton therapy system in Nagoya Proton Therapy Center (NPTC). The NPTC has a synchrotron with a linac injector and three treatment rooms: two rooms are equipped with a gantry and the other one is equipped with a fixed horizontal beamline. One gantry treatment ro...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-016-0456-8

    authors: Toshito T,Omachi C,Kibe Y,Sugai H,Hayashi K,Shibata H,Yasui K,Tanaka K,Yamamoto T,Yoshida A,Nikawa E,Asai K,Shimomura A,Okumura I,Suzuki T,Kinou H,Isoyama S,Ogino H,Iwata H,Shibamoto Y,Mizoe J

    更新日期:2016-09-01 00:00:00

  • Effects of treatment distance and field size on build-up characteristics of Monte Carlo calculated absorbed dose for electron irradiation.

    abstract::Surface, build-up and depth dose characteristics of a monoenergetic electron point source simulated by Monte Carlo code MCNP4c for varying field size and SSD are extensively studied in this paper. MCNP4c (Monte Carlo N-Particle Transport Code System) has been extensively used in clinical dose simulation for its versat...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178652

    authors: Lin H,Wu DS,Wu AD

    更新日期:2004-12-01 00:00:00

  • An application of linear output error modelling for studying lymphocyte migration in peripheral lymphoid tissues.

    abstract::Lymphocyte recirculation between lymphatic and blood vessels and migration through tissues are essential mechanisms underlying immunological surveillance. However, the kinetics of lymphocyte migration through lymphoid tissues remains poorly understood. The present study of lymphocyte migration, based on a sheep model ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178774

    authors: Srikusalanukul W,De Bruyne F,McCullagh P

    更新日期:2002-09-01 00:00:00

  • Bicoherence analysis of quadriceps electromyogram during isometric knee extension.

    abstract::Bicoherence analysis is applied to electromyogram (EMG) data for the vastus lateralis quadriceps muscle of 18 adult male subjects for isometric knee extension exercise. Bicoherence spectra display ridge-like features that are indicative of deterministic chaotic behaviour and similar to those reported for normal electr...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1007/BF03178691

    authors: Simeoni RJ,Mills PM

    更新日期:2003-03-01 00:00:00

  • An effective approach to classify epileptic EEG signal using local neighbor gradient pattern transformation methods.

    abstract::Electroencephalographic (EEG) signal records the neuronal activity in the brain and it is used in the diagnosis of epileptic seizure activities. Human inspection of non-stationary EEG signal for diagnosing epilepsy is cumbersome, time-consuming and inaccurate. In this paper an effective automatic approach to detect ep...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-018-0697-9

    authors: Sairamya NJ,Thomas George S,Balakrishnan R,Subathra MSP

    更新日期:2018-12-01 00:00:00

  • A feature study of innovative high-speed lancing device and safety lancet.

    abstract::The study developed two models of an innovative high-speed lancing device and safety lancet, where the specially designed structure causes high-speed motion of the lancet, resulting in only one puncture of the skin. The two experimental models and other lancing devices sold on market were compared in order to: (1) mea...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-016-0490-6

    authors: Chang H,Yeh YJ,Lee R,Shyu JH

    更新日期:2016-12-01 00:00:00

  • Non invasive measurement of myocardial motion using magnetic resonance tagging.

    abstract::Magnetic resonance imaging has become a key modality within the modern radiology department. In addition to the conventional slice images, three dimensional angiographic images, and quantitative flow measurements can be obtained. More recently methods have been developed which enable one to visualize the motion of obj...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,评审

    doi:

    authors: McKinnon GC,Fischer SE,Maier SE

    更新日期:1991-12-01 00:00:00

  • Determination of RW3-to-water mass-energy absorption coefficient ratio for absolute dosimetry.

    abstract::The measurement of absorbed dose to water in a solid-phantom may require a conversion factor because it may not be radiologically equivalent to water. One phantom developed for the use of dosimetry is a solid water, RW3 white-polystyrene material by IBA. This has a lower mass-energy absorption coefficient than water d...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-011-0102-4

    authors: Seet KY,Hanlon PM,Charles PH

    更新日期:2011-12-01 00:00:00

  • Photon buildup in orthovoltage X-ray beams.

    abstract::Orthovoltage x-ray beams exhibit the characteristic of depth dose buildup which is not well described in the literature. The principal reason for this phenomenon is the increase in dose deposited due to electrons set in motion by secondary (Compton) scattered photons within the phantom, as depth is increased until lon...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Hill RF,Keall PJ,Beckham WA,Perez MD

    更新日期:1998-06-01 00:00:00

  • Physiologic outcome of varying speed rotary blood pump support algorithms: a review study.

    abstract::Rotary blood pumps have the potential to become a viable long-term treatment option for the heart failure patients to bridge to transplantation or destination therapy. However, these devices operate at a constant speed which may lead to long term complications or they may operate in an undesired support mode such as e...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,评审

    doi:10.1007/s13246-015-0405-y

    authors: Bozkurt S

    更新日期:2016-03-01 00:00:00

  • Film dosimetry for the junction region of four compensated photon beams.

    abstract::A set of four 4 MV photon beam compensators were produced, one for each field of a Hodgkins Disease treatment plan. The resultant dose profiles at various depths were measured by an ion chamber in water and by Kodak X-Omat V film in a Solid Water phantom, and compared to the doses calculated by a GE RT/Plan treatment ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Ralston AC,Francis JW

    更新日期:1992-03-01 00:00:00

  • Automatic counting of nuclear tracks.

    abstract::Two software packages designed for automatic counting nuclear tracks are tested and compared. The image processing in the first package is divided into three parts segmentation, speckle elimination and removal of ill-formed track holes. The second package is also divided into three parts but the last part is modified ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Coakley K,Wong CF,Forbes K,Anh V

    更新日期:1992-06-01 00:00:00

  • Development of a method for manufacturing customized nasal mask cushion for CPAP therapy.

    abstract::A continuous positive airway pressure (CPAP) device is considered one of the most effective treatments for obstructive sleep apnea (OSA). However, many patients receiving this treatment complain of mask discomfort and other issues. Therefore, this study aimed to develop a customized nasal mask cushion to reduce the di...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0383-0

    authors: Hsu DY,Cheng YL,Bien MY,Lee HC

    更新日期:2015-12-01 00:00:00

  • SAR and temperature distribution in the rat head model exposed to electromagnetic field radiation by 900 MHz dipole antenna.

    abstract::Rats are often used in the electromagnetic field (EMF) exposure experiments. In the study for the effect of 900 MHz EMF exposure on learning and memory in SD rats, the specific absorption rate (SAR) and the temperature rise in the rat head are numerically evaluated. The digital anatomical model of a SD rat is reconstr...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-013-0202-4

    authors: Yang L,Hao D,Wu S,Zhong R,Zeng Y

    更新日期:2013-06-01 00:00:00

  • Effects of internal and external scatter on the build-up characteristics of Monte Carlo calculated absorbed dose for electron irradiation.

    abstract::The effects of internal and external scatter on surface, build-up and depth dose characteristics simulated by Monte Carlo code EGSnrc for varying field size and SSD for a 10 MeV monoenergetic electron beam with and without an accelerator model are extensively studied in this paper. In particular, sub-millimetre surfac...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178710

    authors: Lin H,Wu DS,Wu AD

    更新日期:2005-09-01 00:00:00