Abstract:
:A set of four 4 MV photon beam compensators were produced, one for each field of a Hodgkins Disease treatment plan. The resultant dose profiles at various depths were measured by an ion chamber in water and by Kodak X-Omat V film in a Solid Water phantom, and compared to the doses calculated by a GE RT/Plan treatment planning computer. After normalisation and correction for the film's non-linear dose response, the film and ion chamber results compared well with each other. They both showed cold spots of 80% in the junction region of the four fields which were not shown on the computed isodose plan. Film dosimetry is faster than ion chamber dosimetry and is shown to be accurate enough to use for measuring the dose uniformity of compensated beams.
journal_name
Australas Phys Eng Sci Medjournal_title
Australasian physical & engineering sciences in medicineauthors
Ralston AC,Francis JWsubject
Has Abstractpub_date
1992-03-01 00:00:00pages
50-3issue
1eissn
0158-9938issn
1879-5447journal_volume
15pub_type
杂志文章abstract::A 69 year old male was treated with an ablative dose of 3.7 GBq (100 mCi) of I131 for carcinoma of the thyroid and died 10 days after administration. The requirement for an autopsy and the level of radiation still present in the body necessitated the intervention of Radiation Safety Personnel to minimise support staff...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1991-06-01 00:00:00
abstract::The umbilical cord is part of the fetus and generally includes one umbilical vein (UV) and two umbilical arteries (UAs). As the saphenous vein and UV are the most commonly used veins for the coronary artery disease treatment as a coronary artery bypass graft (CABG), understating the mechanical properties of UV has a k...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-014-0294-5
更新日期:2014-12-01 00:00:00
abstract::Segmentation of different tissues is one of the initial and most critical tasks in different aspects of medical image processing. Manual segmentation of brain images resulted from magnetic resonance imaging is time consuming, so automatic image segmentation is widely used in this area. Ensemble based algorithms are ve...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-015-0352-7
更新日期:2015-06-01 00:00:00
abstract::The dosimetric features of the Fricke dosimeter in clinical linear accelerator beams are considered. Experimental data were obtained using various nominal energies 6 and 18 MV, 12 and 15 MeV, including the (60)Co γ-ray beam. The calibration of the dosimeters was performed using the ionization chamber as a reference do...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-011-0093-1
更新日期:2011-12-01 00:00:00
abstract::A general purpose, multi-channel digital data acquisition and analysis system (Amlab, Associative Measurements, Sydney) configured to collect and process physiological signals including electroencephalograph and blood pressure is described. Its advantages over analog and single-purpose instrumentation are discussed as...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1995-09-01 00:00:00
abstract::The effects of internal and external scatter on surface, build-up and depth dose characteristics simulated by Monte Carlo code EGSnrc for varying field size and SSD for a 10 MeV monoenergetic electron beam with and without an accelerator model are extensively studied in this paper. In particular, sub-millimetre surfac...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/BF03178710
更新日期:2005-09-01 00:00:00
abstract::In recent years there has been a significant economic growth in South East Asia, along with it a concurrent development of medical physics. The status of four countries--Malaysia, Thailand, the Philippines and Indonesia are presented. Medical physicists in these countries have been experiencing the usual problems of l...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1997-03-01 00:00:00
abstract::Fibromyalgia syndrome (FMS) is a chronic muscle and skeletal system disease observed generally in women, manifesting itself with a widespread pain and impairing the individual's quality of life. FMS diagnosis is made based on the American College of Rheumatology (ACR) criteria. However, recently the employability and ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-016-0452-z
更新日期:2016-06-01 00:00:00
abstract::Most of the human head models used in dipole localisation research, which have been reported in the literature to date, assume a simplified cranial structure wherein the head is modelled as a set of distinct homogenous tissue compartments. The inherent inhomogeneity of the tissues has so far been ignored in these mode...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/BF03178283
更新日期:2001-03-01 00:00:00
abstract::The purpose of this study was to measure skin dose using radiochromic film for two step-and-shoot IMRT fields and compare the results to the skin dose for a conventional open field. All exposures were made using a 6 MV photon beam produced by a Varian 21EX linear accelerator (Varian Medical Systems, CA, USA) equipped ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/BF03178577
更新日期:2006-09-01 00:00:00
abstract::A electrocardiogram (ECG) central station has been developed for the Intensive Care Unit at Christchurch Hospital. The system allows the selection and display of four ECGs selected from seven bedside monitors in the Unit. It also provides for automatic display, hard copy and audio alarm of ECG from any monitor which h...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1990-03-01 00:00:00
abstract::Gravity associated with postural changes has a strong bearing on haemodynamics of blood flow in arteries. Its effect on stenosed cases has not been widely investigated. In the present study, variation observed in blood flow during postural changes is investigated for different conditions like standing, sleeping and he...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-014-0246-0
更新日期:2014-03-01 00:00:00
abstract::Numerical simulation is performed to demonstrate that hemodynamic factors are significant determinants for the development of a vascular pathology. Experimental measurements by particle image velocimetry are carried out to validate the credibility of the computational approach. We present a study for determining compl...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-010-0050-4
更新日期:2010-12-01 00:00:00
abstract::Peripheral doses out of field could have short and long terms biological effects on patients treated with electron beams. In this study, peripheral dose outside the applicator was measured using the 6, 10 and 18 MeV beams of an Elekta synergy linac. For these beams dose profiles were measured using EBT3 film at variou...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-018-0660-9
更新日期:2018-09-01 00:00:00
abstract::The effect of radiation in regard to breast carcinogenesis is well studied and analysed from data from atomic bomb survivors, patients treated for acute mastitis and tuberculosis patients monitored by fluoroscopy. Therefore the radiation received by the untreated breast during breast irradiation of the other breast, i...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/BF03178353
更新日期:2001-06-01 00:00:00
abstract::Bicoherence analysis is applied to electromyogram (EMG) data for the vastus lateralis quadriceps muscle of 18 adult male subjects for isometric knee extension exercise. Bicoherence spectra display ridge-like features that are indicative of deterministic chaotic behaviour and similar to those reported for normal electr...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 临床试验,杂志文章
doi:10.1007/BF03178691
更新日期:2003-03-01 00:00:00
abstract::Coronary artery disease producing ischemic cardiomyopathy is the most frequent cause of left ventricular systolic dysfunction. Non-ischemic cardiomyopathies can also produce systolic dysfunction; they may be inherited as genetic disorders or occur sporadically. These coronary injuries have repercussions on the left ve...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/BF03178864
更新日期:2005-03-01 00:00:00
abstract::Laparoscopic ultrasound (LUS) has been widely utilized as a surgical aide in general, urological, and gynecological applications. Our study summarizes the clinical applications of laparoscopic ultrasonography in laparoscopic gynecologic surgery. Retrospective analyses were performed on 42 women subjects using laparosc...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-015-0363-4
更新日期:2015-12-01 00:00:00
abstract::Diamond detectors are particularly well suited for dosimetry applications in radiotherapy for reasons including near-tissue equivalence and high-spatial resolution resulting from small sensitive volumes. However, these detectors have not become commonplace due to high cost and poor availability arising from the need f...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-010-0040-6
更新日期:2010-12-01 00:00:00
abstract::Bipolar disorder (BD) is a severe psychiatric disorder and has two common types: type I and type II. Early diagnosis of the subtypes is very challenging particularly in adolescence. In this study, 38 adolescents are participated including 18 patients with BD I and 20 patients with BD II. The electroencephalogram signa...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-015-0375-0
更新日期:2015-12-01 00:00:00
abstract::Electron beams can be used for the radiotherapy treatment of superficial cancers. In many cases of electron beam radiotherapy, tissue equivalent bolus material placed on the skin is to be used to enhance skin dose. An air gap might be present between the bolus and the skin due to variation in the patient contour. The ...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/BF03178415
更新日期:2007-06-01 00:00:00
abstract::X-ray imaging of the chest is challenging because of the large differences in x-ray attenuation between the mediastinal and lung regions of the chest. This large dynamic range of chest exit exposure, along with associated large changes in the scatter component of the beam, makes film based chest imaging difficult to o...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1993-12-01 00:00:00
abstract::Compression techniques are vital for efficient storage and fast transfer of medical image data. The existing compression techniques take significant amount of time for performing encoding and decoding and hence the purpose of compression is not fully satisfied. In this paper a rapid 4-D lossy compression method constr...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-015-0385-y
更新日期:2015-12-01 00:00:00
abstract::The accuracy of a computed tomography (CT)-relative electron density (RED) curve may have an indirect impact on the accuracy of dose calculation by a treatment planning system (TPS). This effect has not been previously quantified for input of different CT-RED curves from different CT-scan units in the Monaco TPS. This...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-019-00745-6
更新日期:2019-06-01 00:00:00
abstract::A solid water breast phantom with a lung equivalent material was constructed to investigate interface effects of 6 MV tangential photon fields. The phantom was built so that Thermo-luminescence Dosimeters (TLD) could be used for comparison to a pencil beam and Equivalent Tissue-Air-Ratio (ETAR) algorithms. The investi...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:
更新日期:1998-03-01 00:00:00
abstract::Helical tomotherapy (HT) is a novel radiotherapy treatment modality that allows the delivery of intensity modulated radiation in a rotational fashion. Due to the complexity of the treatment approach, it is desirable to have a simple tool for treatment delivery verification. Radiographic film placed under the patient i...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/BF03178723
更新日期:2005-12-01 00:00:00
abstract::The Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) Radiation Oncology Specialty Group (ROSG) formed a series of working groups in 2011 to develop position papers for guidance of radiation oncology medical physics practice within the Australasian setting. These position papers are intend...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-013-0238-5
更新日期:2014-03-01 00:00:00
abstract::Conventional laser accelerated proton beam has broad energy spectra. It is not suitable for clinical use directly, so it is necessary for employing energy selection system. However, in the conventional laser accelerated proton system, the intensity of the proton beams in the low energy regime is higher than that in th...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-014-0292-7
更新日期:2014-12-01 00:00:00
abstract::The computed tomography (CT) imaging artefacts that metallic medical implants produce in surrounding tissues are usually contoured and over-ridden during radiotherapy treatment planning. In cases where radiotherapy treatment beams unavoidably pass though implants, it is especially important to understand the imaging a...
journal_title:Australasian physical & engineering sciences in medicine
pub_type: 杂志文章
doi:10.1007/s13246-013-0197-x
更新日期:2013-06-01 00:00:00
abstract::Monte Carlo modelling of particle transport problems in medical radiation physics offers significant advantages over other techniques. Experiments can be performed without having to set up the physical situation, and "impossible" experiments can be performed, such as labelling multiple-scattered particles or simulatin...
journal_title:Australasian physical & engineering sciences in medicine
pub_type:
doi:
更新日期:1990-09-01 00:00:00