Effective generation of the spread-out-Bragg peak from the laser accelerated proton beams using a carbon-proton mixed target.

Abstract:

:Conventional laser accelerated proton beam has broad energy spectra. It is not suitable for clinical use directly, so it is necessary for employing energy selection system. However, in the conventional laser accelerated proton system, the intensity of the proton beams in the low energy regime is higher than that in the high energy regime. Thus, to generate spread-out-Bragg peak (SOBP), stronger weighting value to the higher energy proton beams is needed and weaker weighting value to the lower energy proton beams is needed, which results in the wide range of weighting values. The purpose of this research is to investigate a method for efficient generating of the SOBP with varying magnetic field in the energy selection system using a carbon-proton mixture target. Energy spectrum of the laser accelerated proton beams was acquired using Particle-In-Cell simulations. The Geant4 Monte Carlo simulation toolkit was implemented for energy selection, particle transportation, and dosimetric property measurement. The energy selection collimator hole size of the energy selection system was changed from 1 to 5 mm in order to investigate the effect of hole size on the dosimetric properties for Bragg peak and SOBP. To generate SOBP, magnetic field in the energy selection system was changed during beam irradiation with each beam weighting factor. In this study, our results suggest that carbon-proton mixture target based laser accelerated proton beams can generate quasi-monoenergetic energy distribution and result in the efficient generation of SOBP. A further research is needed to optimize SOBP according to each range and modulated width using an optimized weighting algorithm.

authors

Yoo SH,Cho I,Cho S,Song Y,Jung WG,Kim DH,Shin D,Lee SB,Pae KH,Park SY

doi

10.1007/s13246-014-0292-7

subject

Has Abstract

pub_date

2014-12-01 00:00:00

pages

635-44

issue

4

eissn

0158-9938

issn

1879-5447

journal_volume

37

pub_type

杂志文章
  • Automated ventilator testing.

    abstract::A new era has arrived for the Biomedical Engineering Department at the Royal Women's Hospital in Melbourne. We have developed a system to qualitatively test for intermittent or unconfirmed faults, associated with Bear Cub ventilators. Where previous testing has been inadequate, computer logging is now used to interfac...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Ghaly J,Smith AL

    更新日期:1994-06-01 00:00:00

  • NEMA NU 2-2001 performance testing of a Philips Gemini GXL PET/CT scanner.

    abstract::Post installation acceptance testing is vital to demonstrate that the equipment meets the vendor's specification and is suitable for clinical studies. The test procedures described in the NEMA NU 2-2001 document form the basis of vendor performance specifications of PET scanners and hence are also appropriate for acce...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-010-0016-6

    authors: Sathiakumar C,Som S,Eberl S,Lin P

    更新日期:2010-06-01 00:00:00

  • The linear accelerator mechanical and radiation isocentre assessment with an electronic portal imaging device (EPID).

    abstract::Regular checks on the performance of radiotherapy treatment units are essential and a variety of protocols has been published. These protocols identify that the determination of isocentre must be accurate and unambiguous since both the localization of a radiation field on a patient and positioning aids are referenced ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178670

    authors: Liu G,van Doorn T,Bezak E

    更新日期:2004-09-01 00:00:00

  • Complexity quantification of cardiac variability time series using improved sample entropy (I-SampEn).

    abstract::The sample entropy (SampEn) has been widely used to quantify the complexity of RR-interval time series. It is a fact that higher complexity, and hence, entropy is associated with the RR-interval time series of healthy subjects. But, SampEn suffers from the disadvantage that it assigns higher entropy to the randomized ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-016-0457-7

    authors: Marwaha P,Sunkaria RK

    更新日期:2016-09-01 00:00:00

  • A model based on the Pennes bioheat transfer equation is valid in normal brain tissue but not brain tissue suffering focal ischaemia.

    abstract::Ischaemic stroke is a major public health issue in both developed and developing nations. Hypothermia is believed to be neuroprotective in cerebral ischaemia. Conversely, elevated brain temperature is associated with poor outcome after ischaemic stroke. Mechanisms of heat exchange in normally-perfused brain are relati...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-017-0595-6

    authors: Lillicrap T,Tahtalı M,Neely A,Wang X,Bivard A,Lueck C

    更新日期:2017-12-01 00:00:00

  • Glaucoma detection using novel optic disc localization, hybrid feature set and classification techniques.

    abstract::Glaucoma is a chronic and irreversible neuro-degenerative disease in which the neuro-retinal nerve that connects the eye to the brain (optic nerve) is progressively damaged and patients suffer from vision loss and blindness. The timely detection and treatment of glaucoma is very crucial to save patient's vision. Compu...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0377-y

    authors: Akram MU,Tariq A,Khalid S,Javed MY,Abbas S,Yasin UU

    更新日期:2015-12-01 00:00:00

  • Determination of RW3-to-water mass-energy absorption coefficient ratio for absolute dosimetry.

    abstract::The measurement of absorbed dose to water in a solid-phantom may require a conversion factor because it may not be radiologically equivalent to water. One phantom developed for the use of dosimetry is a solid water, RW3 white-polystyrene material by IBA. This has a lower mass-energy absorption coefficient than water d...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-011-0102-4

    authors: Seet KY,Hanlon PM,Charles PH

    更新日期:2011-12-01 00:00:00

  • Preliminary expansion of the resonant recognition model to incorporate multi variable analysis.

    abstract::The Resonant Recognition Model (rrm) uses digital signal processing methods to investigate protein structure-function; and links the biological function of protein families to unique characteristic frequencies. The rrm originally used a single set of variables: the electron ion interaction potential (EIIP). Here the r...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Birch S,West R,Cosic I

    更新日期:1995-12-01 00:00:00

  • Using EGS4 Monte Carlo in medical radiation physics.

    abstract::Monte Carlo modelling of particle transport problems in medical radiation physics offers significant advantages over other techniques. Experiments can be performed without having to set up the physical situation, and "impossible" experiments can be performed, such as labelling multiple-scattered particles or simulatin...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type:

    doi:

    authors: Murray D

    更新日期:1990-09-01 00:00:00

  • The angular and energy distribution of the primary electron beam.

    abstract::The angular distribution for electron beams produced by the Siemens KD-2 linear accelerator has been found by simulating electron transport through the scattering foils and air using two methods: Fermi-Eyges multiple Coulomb scattering calculations, and EGS4 Monte Carlo simulations. Fermi-Eyges theory gives solutions ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Keall PJ,Hoban PW

    更新日期:1994-09-01 00:00:00

  • Shielding properties of fibre cement wallboard.

    abstract::Transmission data for a fibre cement wallboard (villaboard) are determined for use in diagnostic shielding designs. Villaboard is found to be more attenuating than plasterboard e.g. 9 mm of villaboard is equivalent to 16 mm of plasterboard. ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Thiele DL,Godwin GA,Coakley KS

    更新日期:1998-09-01 00:00:00

  • Stereotactic dose perturbation from an aneurysm clip measured by Gafchromic EBT film.

    abstract::Aneurysm clips within stereotactic treatment volumes enhance spatial accuracy but perturb the dose distribution. The dose perturbations caused by a standard titanium alloy aneurysm clip (Ti6Al4V) have been measured with Gafchromic EBT film. The maximum dose perturbation was an increase of 6 % within 0.5 mm of the beam...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178449

    authors: He CF,Geso M,Ackerly T,Wong CJ

    更新日期:2008-03-01 00:00:00

  • Development of a method for manufacturing customized nasal mask cushion for CPAP therapy.

    abstract::A continuous positive airway pressure (CPAP) device is considered one of the most effective treatments for obstructive sleep apnea (OSA). However, many patients receiving this treatment complain of mask discomfort and other issues. Therefore, this study aimed to develop a customized nasal mask cushion to reduce the di...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0383-0

    authors: Hsu DY,Cheng YL,Bien MY,Lee HC

    更新日期:2015-12-01 00:00:00

  • Multi-layer cube sampling for liver boundary detection in PET-CT images.

    abstract::Liver metabolic information is considered as a crucial diagnostic marker for the diagnosis of fever of unknown origin, and liver recognition is the basis of automatic diagnosis of metabolic information extraction. However, the poor quality of PET and CT images is a challenge for information extraction and target recog...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-018-0650-y

    authors: Liu X,Yang J,Song S,Song H,Ai D,Zhu J,Jiang Y,Wang Y

    更新日期:2018-06-01 00:00:00

  • Thermoluminescence dosimetry and its applications in medicine--Part 1: Physics, materials and equipment.

    abstract::Thermoluminescence dosimetry (TLD) is a versatile tool for the assessment of dose from ionising radiation. The wide variety of TLD materials and their different physical forms allow the determination of different radiation qualities at dose levels from microGy to kGy. Major advantages of TL dosimeters are their small ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,评审

    doi:

    authors: Kron T

    更新日期:1994-12-01 00:00:00

  • Evaluation of Bremsstrahlung radiation dose in stereotactically radiocolloid therapy of cystic craniopharyngioma tumors with 32P radio-colloid.

    abstract::Over 90% of craniopharyngeal brain tumors are cystic, which enables the injection of beta emitters such as phosphorus-32 (32P) radio-colloid into cysts for their treatment. The aim of this study was to evaluate the clinical and theoretical modelling of Bremsstrahlung radiation dose resulting from stereotactic radio-co...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-018-0665-4

    authors: Babaei M,Ghahramani-Asl R,Sadoughi HR,Sardari D,Shahzadi S

    更新日期:2018-09-01 00:00:00

  • Medical physics is alive and well and growing in South East Asia.

    abstract::In recent years there has been a significant economic growth in South East Asia, along with it a concurrent development of medical physics. The status of four countries--Malaysia, Thailand, the Philippines and Indonesia are presented. Medical physicists in these countries have been experiencing the usual problems of l...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Ng K,Pirabul R,Peralta A,Soejoko D

    更新日期:1997-03-01 00:00:00

  • Performance of independent dose calculation in helical tomotherapy: implementation of the MCSIM code.

    abstract::Currently, a software-based second check dose calculation for helical tomotherapy (HT) is not available. The goal of this study is to evaluate the dose calculation accuracy of the in-house software using EGS4/MCSIM Monte Carlo environment against the treatment planning system calculations. In-house software was used t...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-012-0165-x

    authors: Dzintars E,Stathakis S,Mavroidis P,Sadeghi A,Papanikolaou N

    更新日期:2012-12-01 00:00:00

  • Simultaneous EEG-fMRI for working memory of the human brain.

    abstract::Memory plays an important role in human life. Memory can be divided into two categories, i.e., long term memory and short term memory (STM). STM or working memory (WM) stores information for a short span of time and it is used for information manipulations and fast response activities. WM is generally involved in the ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,评审

    doi:10.1007/s13246-016-0438-x

    authors: Ahmad RF,Malik AS,Kamel N,Reza F,Abdullah JM

    更新日期:2016-06-01 00:00:00

  • A feature study of innovative high-speed lancing device and safety lancet.

    abstract::The study developed two models of an innovative high-speed lancing device and safety lancet, where the specially designed structure causes high-speed motion of the lancet, resulting in only one puncture of the skin. The two experimental models and other lancing devices sold on market were compared in order to: (1) mea...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-016-0490-6

    authors: Chang H,Yeh YJ,Lee R,Shyu JH

    更新日期:2016-12-01 00:00:00

  • The impact of inhomogeneous tissue anisotropy on potential distribution within head model.

    abstract::This paper investigates the influence of inhomogeneous head tissue conductivity on EEGs. A head model with inhomogeneity of radial and tangential conductivity is built up. Based on this model the EEG signals are calculated using the finite elements method. The results show that the inhomogeneous radial and tangential ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178780

    authors: Wen P

    更新日期:2003-09-01 00:00:00

  • The effects of air cavities on X-ray dose distribution at 6 and 25 MV.

    abstract::Three different air channels were constructed in solid water. These resemble upper respiratory and larynx geometry. Central-axis depth-dose distributions were measured on and beyond the distal surface of the air cavities. The measurements were made with a parallel-plate Markus ionisation chamber and TLDs for 6 and 25 ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Wong TP,Kan WK,Law M

    更新日期:1996-12-01 00:00:00

  • Computer-aided diagnosis system for classifying benign and malignant thyroid nodules in multi-stained FNAB cytological images.

    abstract::An automated computer-aided diagnosis system is developed to classify benign and malignant thyroid nodules using multi-stained fine needle aspiration biopsy (FNAB) cytological images. In the first phase, the image segmentation is performed to remove the background staining information and retain the appropriate foregr...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-013-0199-8

    authors: Gopinath B,Shanthi N

    更新日期:2013-06-01 00:00:00

  • Continuous physiological monitoring: an integrated system for use in neonatal intensive care.

    abstract::A general purpose, multi-channel digital data acquisition and analysis system (Amlab, Associative Measurements, Sydney) configured to collect and process physiological signals including electroencephalograph and blood pressure is described. Its advantages over analog and single-purpose instrumentation are discussed as...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Hall GL,Colditz PB

    更新日期:1995-09-01 00:00:00

  • Skin dose reduction by a clinically viable magnetic deflector.

    abstract::A variable magnetic deflector which attaches onto the treatment head of a linear accelerator has reduced skin dose by as much as 65% for 6MV x-rays. The magnetic deflector is constructed from Neodymium Iron Boron (NdFeB) rare earth magnets. It weighs approximately 15 kg and is designed to easily fit onto the accessory...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Butson MJ,Yu P,Kan M,Carolan M,Young E,Mathur JN,Metcalfe PE

    更新日期:1997-06-01 00:00:00

  • A novel ultrasound based approach for lesion segmentation and its applications in gynecological laparoscopic surgery.

    abstract::Laparoscopic ultrasound (LUS) has been widely utilized as a surgical aide in general, urological, and gynecological applications. Our study summarizes the clinical applications of laparoscopic ultrasonography in laparoscopic gynecologic surgery. Retrospective analyses were performed on 42 women subjects using laparosc...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0363-4

    authors: Gong XH,Lu J,Liu J,Deng YY,Liu WZ,Huang X,Pirbhulal S,Yu ZY,Wu WQ

    更新日期:2015-12-01 00:00:00

  • An effective approach to classify epileptic EEG signal using local neighbor gradient pattern transformation methods.

    abstract::Electroencephalographic (EEG) signal records the neuronal activity in the brain and it is used in the diagnosis of epileptic seizure activities. Human inspection of non-stationary EEG signal for diagnosing epilepsy is cumbersome, time-consuming and inaccurate. In this paper an effective automatic approach to detect ep...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-018-0697-9

    authors: Sairamya NJ,Thomas George S,Balakrishnan R,Subathra MSP

    更新日期:2018-12-01 00:00:00

  • ACPSEM ROSG Oncology-PACS and OIS working group recommendations for quality assurance.

    abstract::The Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) Radiation Oncology Specialty Group (ROSG) formed a series of working groups in 2011 to develop position papers for guidance of radiation oncology medical physics practice within the Australasian setting. These position papers are intend...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-013-0238-5

    authors: Shakeshaft J,Perez M,Tremethick L,Ceylan A,Bailey M

    更新日期:2014-03-01 00:00:00

  • A percolation-like model for simulating inter-cellular diffusion in the context of bystander signalling in tumour.

    abstract::Despite ongoing active research, the role of the radiation bystander effect in modifying local tissue response to an ionising radiation dose remains unclear. The present study aims to provide new insight by simulating the diffusion-mediated inter-cellular communication processes in 2D and 3D cell-like structures to ca...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-010-0048-y

    authors: Moulton CR,Fleming AJ,Ebert MA

    更新日期:2011-04-01 00:00:00

  • Evaluation of EBT radiochromic film using a multiple exposure technique.

    abstract::Radiochromic film is a self developing two-dimensional dosimeter system that is widely used in radiotherapy. Since its development some 40 years ago many improvements have been made; however the sensitivity can vary across the film and a non-linear dose response remains. The former can be addressed using a double expo...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-011-0067-3

    authors: Roozen K,Kron T,Haworth A,Franich R

    更新日期:2011-06-01 00:00:00