Comparison of natural and synthetic diamond X-ray detectors.

Abstract:

:Diamond detectors are particularly well suited for dosimetry applications in radiotherapy for reasons including near-tissue equivalence and high-spatial resolution resulting from small sensitive volumes. However, these detectors have not become commonplace due to high cost and poor availability arising from the need for high-quality diamond. We have fabricated relatively cheap detectors from commercially-available synthetic diamond fabricated using chemical vapour deposition. Here, we present a comparison of one of these detectors with the only commercially-available diamond-based detector (which uses a natural diamond crystal). Parameters such as the energy dependence and linearity of charge with dose were investigated at orthovoltage energies (50-250 kV), and dose-rate dependence of charge at linear accelerator energy (6 MV). The energy dependence of a synthetic diamond detector was similar to that of the natural diamond detector, albeit with slightly less variation across the energy range. Both detectors displayed a linear response with dose (at 100 kV) over the limited dose range used. The sensitivity of the synthetic diamond detector was 302 nC/Gy, compared to 294 nC/Gy measured for the natural diamond detector; however, this was obtained with a bias of 246.50 V compared to a bias of 61.75 V used for the natural diamond detector. The natural diamond detector exhibited a greater dependency on dose-rate than the synthetic diamond detector. Overall, the synthetic diamond detector performed well in comparison to the natural diamond detector.

authors

Lansley SP,Betzel GT,Metcalfe P,Reinisch L,Meyer J

doi

10.1007/s13246-010-0040-6

subject

Has Abstract

pub_date

2010-12-01 00:00:00

pages

301-6

issue

4

eissn

0158-9938

issn

1879-5447

journal_volume

33

pub_type

杂志文章
  • Thermoluminescence dosimetry and its applications in medicine--Part 1: Physics, materials and equipment.

    abstract::Thermoluminescence dosimetry (TLD) is a versatile tool for the assessment of dose from ionising radiation. The wide variety of TLD materials and their different physical forms allow the determination of different radiation qualities at dose levels from microGy to kGy. Major advantages of TL dosimeters are their small ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,评审

    doi:

    authors: Kron T

    更新日期:1994-12-01 00:00:00

  • ACPSEM ROSG TBI working group recommendations for quality assurance in total body irradiation.

    abstract::The Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) radiation oncology specialty group (ROSG) formed a series of working groups in 2011 to develop recommendations for guidance of radiation oncology medical physics practice within the Australasian setting. These recommendations are intend...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,实务指引

    doi:10.1007/s13246-015-0344-7

    authors: Nelligan R,Bailey M,Tran T,Baldwin Z,ACPSEM total body irradiation working group.

    更新日期:2015-06-01 00:00:00

  • Measurement of dose to the contralateral breast during radiation therapy for breast cancer: reduction by the use of superflab.

    abstract::The effect of radiation in regard to breast carcinogenesis is well studied and analysed from data from atomic bomb survivors, patients treated for acute mastitis and tuberculosis patients monitored by fluoroscopy. Therefore the radiation received by the untreated breast during breast irradiation of the other breast, i...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178353

    authors: Jamal N,Das KR

    更新日期:2001-06-01 00:00:00

  • A comparative study on the uniaxial mechanical properties of the umbilical vein and umbilical artery using different stress-strain definitions.

    abstract::The umbilical cord is part of the fetus and generally includes one umbilical vein (UV) and two umbilical arteries (UAs). As the saphenous vein and UV are the most commonly used veins for the coronary artery disease treatment as a coronary artery bypass graft (CABG), understating the mechanical properties of UV has a k...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-014-0294-5

    authors: Karimi A,Navidbakhsh M

    更新日期:2014-12-01 00:00:00

  • Potential radiotherapy improvements with respiratory gating.

    abstract::Gating is a relatively new and potentially useful therapeutic addition to external beam radiotherapy applied to regions affected by intra-fraction motion. The impact was of gating on treatment margins, image artifacts, and volume and positional accuracy was investigated by CT imaging of sinusoidally moving spheres. Th...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178368

    authors: Keall PJ,Kini VR,Vedam SS,Mohan R

    更新日期:2002-03-01 00:00:00

  • Comparison of 192Ir air kerma calibration coefficients derived at ARPANSA using the interpolation method and at the National Physical Laboratory using a direct measurement.

    abstract::The reference air kerma rate from 192Ir High Dose Rate (HDR) brachytherapy sources can be measured using a suitably calibrated Farmer chamber and an appropriate in-air calibration jig. When a primary standard for 192Ir gamma rays is available, a calibration coefficient for the chamber and jig combination can be determ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178603

    authors: Butler D,Haworth A,Sander T,Todd S

    更新日期:2008-12-01 00:00:00

  • CT screening--whole-body and targeted.

    abstract::At present, the Australasian College of Physical Scientists and Engineers in Medicine does not support the practice of self-referred whole-body CT screening of asymptomatic patients because: The procedure involves a non-trivial radiation dose, which assumes even greater significance in the context of an ongoing screen...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 指南,杂志文章

    doi:10.1007/BF03178880

    authors: Le Heron JC,Coakley KS

    更新日期:2004-03-01 00:00:00

  • Improved accuracy of 3D-printed navigational template during complicated tibial plateau fracture surgery.

    abstract::This study was aimed to improve the surgical accuracy of plating and screwing for complicated tibial plateau fracture assisted by 3D implants library and 3D-printed navigational template. Clinical cases were performed whereby complicated tibial plateau fractures were imaged using computed tomography and reconstructed ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0330-0

    authors: Huang H,Hsieh MF,Zhang G,Ouyang H,Zeng C,Yan B,Xu J,Yang Y,Wu Z,Huang W

    更新日期:2015-03-01 00:00:00

  • EEG classification of adolescents with type I and type II of bipolar disorder.

    abstract::Bipolar disorder (BD) is a severe psychiatric disorder and has two common types: type I and type II. Early diagnosis of the subtypes is very challenging particularly in adolescence. In this study, 38 adolescents are participated including 18 patients with BD I and 20 patients with BD II. The electroencephalogram signa...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0375-0

    authors: Khaleghi A,Sheikhani A,Mohammadi MR,Nasrabadi AM,Vand SR,Zarafshan H,Moeini M

    更新日期:2015-12-01 00:00:00

  • Effects of internal and external scatter on the build-up characteristics of Monte Carlo calculated absorbed dose for electron irradiation.

    abstract::The effects of internal and external scatter on surface, build-up and depth dose characteristics simulated by Monte Carlo code EGSnrc for varying field size and SSD for a 10 MeV monoenergetic electron beam with and without an accelerator model are extensively studied in this paper. In particular, sub-millimetre surfac...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178710

    authors: Lin H,Wu DS,Wu AD

    更新日期:2005-09-01 00:00:00

  • Ultrasound shear wave simulation of wave propagation at oblique angles.

    abstract::Shear wave elasticity imaging (SWEI) has been used to measure the local tissue elasticity. The local tissue shear modulus can be reconstructed from the displacement field of shear waves using an algebraic Helmholtz inversion (AHI) equation or a time-of-flight (TOF)-based algorithm. The shear waves, which are generated...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-019-00748-3

    authors: Park DW,Cho HC

    更新日期:2019-09-01 00:00:00

  • Indices from lagged poincare plots of heart rate variability: an efficient nonlinear tool for emotion discrimination.

    abstract::Interest in human emotion recognition, regarding physiological signals, has recently risen. In this study, an efficient emotion recognition system, based on geometrical analysis of autonomic nervous system signals, is presented. The electrocardiogram recordings of 47 college students were obtained during rest conditio...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-017-0530-x

    authors: Goshvarpour A,Abbasi A,Goshvarpour A

    更新日期:2017-06-01 00:00:00

  • A Monte Carlo technique to establish the water/tissue equivalence of phantom materials.

    abstract::The quality of phantom materials is crucial for accurate dosimetry in radiotherapy. A wide range of factors such as density, electron density and elemental composition can influence the radiation properties, and hence the absorbed dose, of materials. New materials can be tested by direct measurements which requires co...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Keall P,Kron T,Hoban P

    更新日期:1993-09-01 00:00:00

  • The linear accelerator mechanical and radiation isocentre assessment with an electronic portal imaging device (EPID).

    abstract::Regular checks on the performance of radiotherapy treatment units are essential and a variety of protocols has been published. These protocols identify that the determination of isocentre must be accurate and unambiguous since both the localization of a radiation field on a patient and positioning aids are referenced ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178670

    authors: Liu G,van Doorn T,Bezak E

    更新日期:2004-09-01 00:00:00

  • Practical considerations for reporting surface dose in external beam radiotherapy: a 6 MV X-ray beam study.

    abstract::In this study, we assessed the accuracy of surface doses determined by direct measurement and treatment planning system (TPS) calculations, relative to benchmark Monte Carlo (MC) doses calculated at 70 μm for a 6 MV, 10 × 10 cm clinical radiotherapy beam. In a homogeneous phantom with both open and fixed wedged fields...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-012-0145-1

    authors: Kim JH,Hill R,Kuncic Z

    更新日期:2012-09-01 00:00:00

  • Computer-aided diagnosis system for classifying benign and malignant thyroid nodules in multi-stained FNAB cytological images.

    abstract::An automated computer-aided diagnosis system is developed to classify benign and malignant thyroid nodules using multi-stained fine needle aspiration biopsy (FNAB) cytological images. In the first phase, the image segmentation is performed to remove the background staining information and retain the appropriate foregr...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-013-0199-8

    authors: Gopinath B,Shanthi N

    更新日期:2013-06-01 00:00:00

  • Physiologic outcome of varying speed rotary blood pump support algorithms: a review study.

    abstract::Rotary blood pumps have the potential to become a viable long-term treatment option for the heart failure patients to bridge to transplantation or destination therapy. However, these devices operate at a constant speed which may lead to long term complications or they may operate in an undesired support mode such as e...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,评审

    doi:10.1007/s13246-015-0405-y

    authors: Bozkurt S

    更新日期:2016-03-01 00:00:00

  • A proton therapy system in Nagoya Proton Therapy Center.

    abstract::The purpose of this paper is to describe an outline of a proton therapy system in Nagoya Proton Therapy Center (NPTC). The NPTC has a synchrotron with a linac injector and three treatment rooms: two rooms are equipped with a gantry and the other one is equipped with a fixed horizontal beamline. One gantry treatment ro...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-016-0456-8

    authors: Toshito T,Omachi C,Kibe Y,Sugai H,Hayashi K,Shibata H,Yasui K,Tanaka K,Yamamoto T,Yoshida A,Nikawa E,Asai K,Shimomura A,Okumura I,Suzuki T,Kinou H,Isoyama S,Ogino H,Iwata H,Shibamoto Y,Mizoe J

    更新日期:2016-09-01 00:00:00

  • The impact of smart metal artefact reduction algorithm for use in radiotherapy treatment planning.

    abstract::The presence of metal artefacts in computed tomography (CT) create issues in radiation oncology. The loss of anatomical information and incorrect Hounsfield unit (HU) values produce inaccuracies in dose calculations, providing suboptimal patient treatment. Metal artefact reduction (MAR) algorithms were developed to co...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-017-0543-5

    authors: Guilfoile C,Rampant P,House M

    更新日期:2017-06-01 00:00:00

  • The use of round ended needles for high dose rate brachytherapy implants.

    abstract::The use of Speiser needles for interstitial implants has resulted in malfunctioning of HDR afterloading equipment due to seepage of blood. We have successfully used rounded ended needles in the patient after removal of the trocar ended needles, preventing the seepage of blood. This technique also helps to prevent any ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Das KR,Duchesne G,Coles JR,Pinder P

    更新日期:1999-12-01 00:00:00

  • An effective approach to classify epileptic EEG signal using local neighbor gradient pattern transformation methods.

    abstract::Electroencephalographic (EEG) signal records the neuronal activity in the brain and it is used in the diagnosis of epileptic seizure activities. Human inspection of non-stationary EEG signal for diagnosing epilepsy is cumbersome, time-consuming and inaccurate. In this paper an effective automatic approach to detect ep...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-018-0697-9

    authors: Sairamya NJ,Thomas George S,Balakrishnan R,Subathra MSP

    更新日期:2018-12-01 00:00:00

  • Instruments to assess and measure personal and environmental radiofrequency-electromagnetic field exposures.

    abstract::Radiofrequency-electromagnetic field (RF-EMF) exposure of human populations is increasing due to the widespread use of mobile phones and other telecommunication and broadcasting technologies. There are ongoing concerns about potential short- and long-term public health consequences from RF-EMF exposures. To elucidate ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,评审

    doi:10.1007/s13246-015-0412-z

    authors: Bhatt CR,Redmayne M,Abramson MJ,Benke G

    更新日期:2016-03-01 00:00:00

  • Comparison study of different head model structures with homogeneous/inhomogeneous conductivity.

    abstract::Most of the human head models used in dipole localisation research, which have been reported in the literature to date, assume a simplified cranial structure wherein the head is modelled as a set of distinct homogenous tissue compartments. The inherent inhomogeneity of the tissues has so far been ignored in these mode...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178283

    authors: Wen P,Li Y

    更新日期:2001-03-01 00:00:00

  • MOSFET dosimetry in-vivo at superficial and orthovoltage x-ray energies.

    abstract::This note investigates in-vivo dosimetry using a Metal Oxide Semiconductor Field Effect Transistor (MOSFET) for radiotherapy treatment at superficial and orthovoltage x-ray energies. This was performed within one fraction of the patients treatment. Standard measurements along with energy response of the detector are g...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Cheung T,Butson MJ,Yu PK

    更新日期:2003-06-01 00:00:00

  • Dose computations for three-dimensional radiation treatment planning.

    abstract::The knowledge of radiation dose at all points of interest within a patient's body is essential for the evaluation of treatment plans and for the judicious selection of the best one from among a set of competing plans. This paper discusses the physical and geometric aspects of radiation dose distribution calculations n...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Mohan R

    更新日期:1989-12-01 00:00:00

  • Bicoherence analysis of quadriceps electromyogram during isometric knee extension.

    abstract::Bicoherence analysis is applied to electromyogram (EMG) data for the vastus lateralis quadriceps muscle of 18 adult male subjects for isometric knee extension exercise. Bicoherence spectra display ridge-like features that are indicative of deterministic chaotic behaviour and similar to those reported for normal electr...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1007/BF03178691

    authors: Simeoni RJ,Mills PM

    更新日期:2003-03-01 00:00:00

  • Light-weight lead aprons--light on weight, protection or labelling accuracy?

    abstract::X-ray transmission tests were performed on a Green-Lite (Infab Corporation) apron/vest combination, and compared to a number of other apron/vest combinations routinely used at Christchurch Hospital as well as a sheet of 0.5 mm lead. The materials were X-rayed using the primary beam of a Philips Optimus 50 X-ray machin...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178704

    authors: Muir S,McLeod R,Dove R

    更新日期:2005-06-01 00:00:00

  • The peripheral dose outside the applicator in electron beams of an Elekta linear accelerator.

    abstract::Peripheral doses out of field could have short and long terms biological effects on patients treated with electron beams. In this study, peripheral dose outside the applicator was measured using the 6, 10 and 18 MeV beams of an Elekta synergy linac. For these beams dose profiles were measured using EBT3 film at variou...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-018-0660-9

    authors: Haghparast A,Amiri F,Yarahmadi M,Rezaei M

    更新日期:2018-09-01 00:00:00

  • The impact of inhomogeneous tissue anisotropy on potential distribution within head model.

    abstract::This paper investigates the influence of inhomogeneous head tissue conductivity on EEGs. A head model with inhomogeneity of radial and tangential conductivity is built up. Based on this model the EEG signals are calculated using the finite elements method. The results show that the inhomogeneous radial and tangential ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178780

    authors: Wen P

    更新日期:2003-09-01 00:00:00

  • Anatomical reduction and precise internal fixation of intra-articular fractures of the distal radius with virtual X-ray and 3D printing.

    abstract::To evaluate and precisely internal fix intra-articular distal radial fracture (IDRF) using the virtual X-ray and three-dimensional (3D) printing technologies. Twenty-one patients with IDRF were recruited, and the data from digital design group (DDG) and real surgery group (RSG) were collected and analyzed. In DDG, the...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-019-00795-w

    authors: Xu J,Zhang G,He Z,Zhong S,Chen Y,Wei C,Zheng Y,Lin H,Li W,Huang W

    更新日期:2019-10-22 00:00:00