The calibration of plane parallel ionisation chambers for the measurement of absorbed dose in electron beams of low to medium energies. Part 1: the NACP chamber.

Abstract:

:A study was made of calibrating the NACP plane parallel chamber in electron beams from linear accelerators of a different manufacture with energies, Ep,o' from 4.4 to 19.1 MeV, and also in 4 and 6 MV photon beams as well as a cobalt60 beam. The photon beam measurements were both IN-AIR and IN-PHANTOM. With the exception of the lowest energy electron beam (nominal 5 MeV), the ND values from measurements in the electron beams were within +/- 1% of the average value from the three different methods according to the AAPM TG 39 protocol. The preferred method of calibration of an electron chamber is of course in an electron beam at R100 in water. This can still be done in medium energy electron beams (nominal 7 to 14 MeV) for the NACP chamber with the same degree of accuracy and precision as with AAPM TG 39 methodology. Alternatively the traditional cobalt-60 calibration beam can be replaced by a low energy (4-6MV) photon beam for in-phantom calibrations at 50 mm depth, giving comparable results, and with no more uncertainties than those obtained in electron beams.

authors

Cross P,Freeman N

subject

Has Abstract

pub_date

1996-09-01 00:00:00

pages

197-200

issue

3

eissn

0158-9938

issn

1879-5447

journal_volume

19

pub_type

杂志文章
  • SAR and temperature distribution in the rat head model exposed to electromagnetic field radiation by 900 MHz dipole antenna.

    abstract::Rats are often used in the electromagnetic field (EMF) exposure experiments. In the study for the effect of 900 MHz EMF exposure on learning and memory in SD rats, the specific absorption rate (SAR) and the temperature rise in the rat head are numerically evaluated. The digital anatomical model of a SD rat is reconstr...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-013-0202-4

    authors: Yang L,Hao D,Wu S,Zhong R,Zeng Y

    更新日期:2013-06-01 00:00:00

  • Potential radiotherapy improvements with respiratory gating.

    abstract::Gating is a relatively new and potentially useful therapeutic addition to external beam radiotherapy applied to regions affected by intra-fraction motion. The impact was of gating on treatment margins, image artifacts, and volume and positional accuracy was investigated by CT imaging of sinusoidally moving spheres. Th...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178368

    authors: Keall PJ,Kini VR,Vedam SS,Mohan R

    更新日期:2002-03-01 00:00:00

  • Human brain wave activity during exposure to radiofrequency field emissions from mobile phones.

    abstract::The aim of this study was to determine whether there is an effect of mobile phone electromagnetic field emissions on the human electroencephalograph (EEG). EEG recordings from ten awake subjects were taken during exposure to radiofrequency (RF) emissions from a mobile phone positioned behind the head. Two experimental...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1007/BF03179176

    authors: D'Costa H,Trueman G,Tang L,Abdel-rahman U,Abdel-rahman W,Ong K,Cosic I

    更新日期:2003-12-01 00:00:00

  • An investigation of central axis depth dose distribution perturbation due to an air gap between patient and bolus for electron beams.

    abstract::Electron beams can be used for the radiotherapy treatment of superficial cancers. In many cases of electron beam radiotherapy, tissue equivalent bolus material placed on the skin is to be used to enhance skin dose. An air gap might be present between the bolus and the skin due to variation in the patient contour. The ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178415

    authors: Kong M,Holloway L

    更新日期:2007-06-01 00:00:00

  • Recent developments in radiation therapy planning and treatment optimization.

    abstract::Radiation therapy of cancer is today going through a very dynamic development with the introduction of a large number of new treatment principles, new types of treatment units and new radiobiologically based optimization algorithms for treatment planning. All of these make use of the recent developments in three dimen...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,评审

    doi:

    authors: Brahme A

    更新日期:1996-06-01 00:00:00

  • Hidden pattern discovery on epileptic EEG with 1-D local binary patterns and epileptic seizures detection by grey relational analysis.

    abstract::This paper proposes a novel approach to detect epilepsy seizures by using Electroencephalography (EEG), which is one of the most common methods for the diagnosis of epilepsy, based on 1-Dimension Local Binary Pattern (1D-LBP) and grey relational analysis (GRA) methods. The main aim of this paper is to evaluate and val...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0362-5

    authors: Kaya Y

    更新日期:2015-09-01 00:00:00

  • Light-weight lead aprons--light on weight, protection or labelling accuracy?

    abstract::X-ray transmission tests were performed on a Green-Lite (Infab Corporation) apron/vest combination, and compared to a number of other apron/vest combinations routinely used at Christchurch Hospital as well as a sheet of 0.5 mm lead. The materials were X-rayed using the primary beam of a Philips Optimus 50 X-ray machin...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178704

    authors: Muir S,McLeod R,Dove R

    更新日期:2005-06-01 00:00:00

  • AFOMP Policy Statement No. 3: recommendations for the education and training of medical physicists in AFOMP countries.

    abstract::AFOMP recognizes that clinical medical physicists should demonstrate that they are competent to practice their profession by obtaining appropriate education, training and supervised experience in the specialties of medical physics in which they practice, as well as having a basic knowledge of other specialties. To hel...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,评审

    doi:10.1007/s13246-011-0091-3

    authors: Round WH,Ng KH,Healy B,Rodriguez L,Thayalan K,Tang F,Fukuda S,Srivastava R,Krisanachinda A,Shiau AC,Deng X,Han Y

    更新日期:2011-09-01 00:00:00

  • Medical physics aspects of cancer care in the Asia Pacific region: 2014 survey results.

    abstract::It was the aim of this work to assess and track the workload, working conditions and professional recognition of radiation oncology medical physicists (ROMPs) in the Asia Pacific region over time. In this third survey since 2008, a structured questionnaire was mailed in 2014 to 22 senior medical physicists representin...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0373-2

    authors: Kron T,Azhari HA,Voon EO,Cheung KY,Ravindran P,Soejoko D,Inamura K,Han Y,Ung NM,TsedenIsh B,Win UM,Srivastava R,Marsh S,Farrukh S,Rodriguez L,Kuo M,Baggarley S,DilipKumara AH,Lee CC,Krisanachinda A,Nguyen XC,Ng

    更新日期:2015-09-01 00:00:00

  • Influence of normalization and color features on super-pixel classification: application to cytological image segmentation.

    abstract::Super-pixel feature extraction is a key problem to get an acceptable performance in color super-pixel classification. Given a color feature extraction problem, it is necessary to know which is the best approach to solve this problem. In the current work, we're interested in the challenge of nucleus and cytoplasm autom...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-019-00735-8

    authors: Bechar MEA,Settouti N,Daho MEH,Adel M,Chikh MA

    更新日期:2019-06-01 00:00:00

  • ACPSEM ROSG TBI working group recommendations for quality assurance in total body irradiation.

    abstract::The Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) radiation oncology specialty group (ROSG) formed a series of working groups in 2011 to develop recommendations for guidance of radiation oncology medical physics practice within the Australasian setting. These recommendations are intend...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,实务指引

    doi:10.1007/s13246-015-0344-7

    authors: Nelligan R,Bailey M,Tran T,Baldwin Z,ACPSEM total body irradiation working group.

    更新日期:2015-06-01 00:00:00

  • A new approach to dose estimation and in-phantom figure of merit measurement in BNCT by using artificial neural networks.

    abstract::In-phantom figures of merit of the radiobiological dose distribution are the main criteria for evaluation of the boron neutron capture therapy (BNCT) plan and neutron beam evaluation. Since in BNCT there are several reactions, which contribute to the total dose of the tissue, the calculation of the dose distribution i...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-011-0107-z

    authors: Ahangari R,Afarideh H

    更新日期:2011-12-01 00:00:00

  • Comparison of natural and synthetic diamond X-ray detectors.

    abstract::Diamond detectors are particularly well suited for dosimetry applications in radiotherapy for reasons including near-tissue equivalence and high-spatial resolution resulting from small sensitive volumes. However, these detectors have not become commonplace due to high cost and poor availability arising from the need f...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-010-0040-6

    authors: Lansley SP,Betzel GT,Metcalfe P,Reinisch L,Meyer J

    更新日期:2010-12-01 00:00:00

  • Non invasive measurement of myocardial motion using magnetic resonance tagging.

    abstract::Magnetic resonance imaging has become a key modality within the modern radiology department. In addition to the conventional slice images, three dimensional angiographic images, and quantitative flow measurements can be obtained. More recently methods have been developed which enable one to visualize the motion of obj...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章,评审

    doi:

    authors: McKinnon GC,Fischer SE,Maier SE

    更新日期:1991-12-01 00:00:00

  • Proposing feature engineering method based on deep learning and K-NNs for ECG beat classification and arrhythmia detection.

    abstract::Arrhythmia is slow, fast or irregular heartbeat. Manual ECG assessment and disease classification is an error-prone task because of vast differences in ECG morphology and difficulty in accurate identifying ECG components. Moreover, proposing a computer-aided diagnosis system for heartbeat classification can be useful ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-019-00814-w

    authors: Khatibi T,Rabinezhadsadatmahaleh N

    更新日期:2019-11-26 00:00:00

  • Optimal selection of mother wavelet for accurate infant cry classification.

    abstract::Wavelet theory is emerging as one of the prevalent tool in signal and image processing applications. However, the most suitable mother wavelet for these applications is still a relative question mark amongst researchers. Selection of best mother wavelet through parameterization leads to better findings for the analysi...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-014-0264-y

    authors: Saraswathy J,Hariharan M,Nadarajaw T,Khairunizam W,Yaacob S

    更新日期:2014-06-01 00:00:00

  • Film dosimetry for the junction region of four compensated photon beams.

    abstract::A set of four 4 MV photon beam compensators were produced, one for each field of a Hodgkins Disease treatment plan. The resultant dose profiles at various depths were measured by an ion chamber in water and by Kodak X-Omat V film in a Solid Water phantom, and compared to the doses calculated by a GE RT/Plan treatment ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Ralston AC,Francis JW

    更新日期:1992-03-01 00:00:00

  • The use of round ended needles for high dose rate brachytherapy implants.

    abstract::The use of Speiser needles for interstitial implants has resulted in malfunctioning of HDR afterloading equipment due to seepage of blood. We have successfully used rounded ended needles in the patient after removal of the trocar ended needles, preventing the seepage of blood. This technique also helps to prevent any ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Das KR,Duchesne G,Coles JR,Pinder P

    更新日期:1999-12-01 00:00:00

  • MOSFET dosimetry in-vivo at superficial and orthovoltage x-ray energies.

    abstract::This note investigates in-vivo dosimetry using a Metal Oxide Semiconductor Field Effect Transistor (MOSFET) for radiotherapy treatment at superficial and orthovoltage x-ray energies. This was performed within one fraction of the patients treatment. Standard measurements along with energy response of the detector are g...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Cheung T,Butson MJ,Yu PK

    更新日期:2003-06-01 00:00:00

  • A rapid compression technique for 4-D functional MRI images using data rearrangement and modified binary array techniques.

    abstract::Compression techniques are vital for efficient storage and fast transfer of medical image data. The existing compression techniques take significant amount of time for performing encoding and decoding and hence the purpose of compression is not fully satisfied. In this paper a rapid 4-D lossy compression method constr...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-015-0385-y

    authors: Uma Vetri Selvi G,Nadarajan R

    更新日期:2015-12-01 00:00:00

  • Software tool for portal dosimetry research.

    abstract::This paper describes a software tool developed for research into the use of an electronic portal imaging device (EPID) to verify dose for intensity modulated radiation therapy (IMRT) beams. A portal dose image prediction (PDIP) model that predicts the EPID response to IMRT beams has been implemented into a commerciall...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03179347

    authors: Vial P,Hunt P,Greer PB,Oliver L,Baldock C

    更新日期:2008-09-01 00:00:00

  • Dose computations for three-dimensional radiation treatment planning.

    abstract::The knowledge of radiation dose at all points of interest within a patient's body is essential for the evaluation of treatment plans and for the judicious selection of the best one from among a set of competing plans. This paper discusses the physical and geometric aspects of radiation dose distribution calculations n...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Mohan R

    更新日期:1989-12-01 00:00:00

  • Polymer gel dosimeters with PVA-GA matrix.

    abstract::Properties of a new polymer gel with cross-linked polyvinyl alcohol as a gelatinous matrix were investigated. The new polymer gel dosimeter was named PVABAT. The irradiation was performed using a calibrated 60Co beam. The dose responses of the PVABAT formulations were quantified with MRI transverse relaxation rate (R2...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-017-0573-z

    authors: Abtahi SMM,Sadeghi Abandansari H

    更新日期:2017-09-01 00:00:00

  • A simulation study comparing nine mathematical models of arterial input function for dynamic contrast enhanced MRI to the Parker model.

    abstract::Due to large inter- and intra-patient variabilities of arterial input functions (AIFs), accurately modeling and using patient-specific AIF are very important for quantitative analysis of dynamic contrast enhanced MRI. Computer simulations were performed to evaluate and compare nine population AIF models with the Parke...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-018-0632-0

    authors: He D,Xu L,Qian W,Clarke J,Fan X

    更新日期:2018-06-01 00:00:00

  • A model based on the Pennes bioheat transfer equation is valid in normal brain tissue but not brain tissue suffering focal ischaemia.

    abstract::Ischaemic stroke is a major public health issue in both developed and developing nations. Hypothermia is believed to be neuroprotective in cerebral ischaemia. Conversely, elevated brain temperature is associated with poor outcome after ischaemic stroke. Mechanisms of heat exchange in normally-perfused brain are relati...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-017-0595-6

    authors: Lillicrap T,Tahtalı M,Neely A,Wang X,Bivard A,Lueck C

    更新日期:2017-12-01 00:00:00

  • Evaluation of EBT radiochromic film using a multiple exposure technique.

    abstract::Radiochromic film is a self developing two-dimensional dosimeter system that is widely used in radiotherapy. Since its development some 40 years ago many improvements have been made; however the sensitivity can vary across the film and a non-linear dose response remains. The former can be addressed using a double expo...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-011-0067-3

    authors: Roozen K,Kron T,Haworth A,Franich R

    更新日期:2011-06-01 00:00:00

  • Effects of internal and external scatter on the build-up characteristics of Monte Carlo calculated absorbed dose for electron irradiation.

    abstract::The effects of internal and external scatter on surface, build-up and depth dose characteristics simulated by Monte Carlo code EGSnrc for varying field size and SSD for a 10 MeV monoenergetic electron beam with and without an accelerator model are extensively studied in this paper. In particular, sub-millimetre surfac...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178710

    authors: Lin H,Wu DS,Wu AD

    更新日期:2005-09-01 00:00:00

  • Medical physics is alive and well and growing in South East Asia.

    abstract::In recent years there has been a significant economic growth in South East Asia, along with it a concurrent development of medical physics. The status of four countries--Malaysia, Thailand, the Philippines and Indonesia are presented. Medical physicists in these countries have been experiencing the usual problems of l...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:

    authors: Ng K,Pirabul R,Peralta A,Soejoko D

    更新日期:1997-03-01 00:00:00

  • The linear accelerator mechanical and radiation isocentre assessment with an electronic portal imaging device (EPID).

    abstract::Regular checks on the performance of radiotherapy treatment units are essential and a variety of protocols has been published. These protocols identify that the determination of isocentre must be accurate and unambiguous since both the localization of a radiation field on a patient and positioning aids are referenced ...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/BF03178670

    authors: Liu G,van Doorn T,Bezak E

    更新日期:2004-09-01 00:00:00

  • Extended Kalman smoother with differential evolution technique for denoising of ECG signal.

    abstract::Electrocardiogram (ECG) signal gives a lot of information on the physiology of heart. In reality, noise from various sources interfere with the ECG signal. To get the correct information on physiology of the heart, noise cancellation of the ECG signal is required. In this paper, the effectiveness of extended Kalman sm...

    journal_title:Australasian physical & engineering sciences in medicine

    pub_type: 杂志文章

    doi:10.1007/s13246-016-0468-4

    authors: Panigrahy D,Sahu PK

    更新日期:2016-09-01 00:00:00