SPET-generated colour-coded polar maps to quantify 99Tcm-MIBI and 123I-BMIPP uptake in chronically dysfunctional myocardium: comparison with coronary anatomy and wall motion.

Abstract:

:The combined use of 123I-BMIPP and 99Tcm-MIBI SPET imaging has been proposed as an alternative to PET for the non-invasive detection of jeopardized myocardium after a myocardial infarction, a mismatch accurately indicating jeopardized but still viable tissue. In this paper, a new quantitative approach is described, expressing the presence and degree of mismatch as the percentage of the left ventricular surface globally as well as for each major epicardial artery by means of clearly identified colour-coded polar maps. With this method, the relative proportion of normal and scar tissue, each characterized by a specific colour, is measured using thresholds of 99Tcm-MIBI uptake of 60% and 30% of the expected mean normal value respectively, whereas the presence and extent of mismatch between 99Tcm-BMIPP and 99Tcm-MIBI are calculated only between these two thresholds, typically corresponding to a reduction in flow associated with a possible but uncertain post-revascularization recovery. Applied to 15 patients with severely impaired left ventricular function after a myocardial infarction, small intra- and inter-observer differences were noted in the assessment of the relative proportion of normal, mismatched and scar tissue. More specifically, analysing the variability in the calculated percent mismatch, good reproducibility was observed, with intra- and inter-observer correlation coefficients of 0.96 and 0.94 respectively, a mean (+/- S.D.) intra-observer difference of 0.25 +/- 2.0% for the left ventricle globally, 1.65 +/- 2.9% for the left anterior descending artery (LAD), -1.56 +/- 3.6% for the left circumflex artery (LCX) and -1.24 +/- 2.8% for the right coronary artery (RCA) territories, and mean inter-observer variability of 0.91 +/- 2.4% for the left ventricle globally, -1.51 +/- 3.0% for the LAD, -0.53 +/- 2.9% for the LCX and -0.34 +/- 3.9% for the RCA territories. Using the second standard deviation of the inter-observer difference as a criterion of significance, a significant mismatch between 99Tcm-BMIPP and 99Tcm-MIBI was noted in 13 arterial territories, corresponding to significant stenoses on coronary angiogram and/or wall motion abnormalities in all cases. These results suggest that this new quantitative method, showing good reproducibility, may constitute a reliable and interesting tool for the non-invasive evaluation of myocardial viability with SPET.

journal_name

Nucl Med Commun

authors

Hambÿe AS,Dobbeleir A,Franken PR

doi

10.1097/00006231-199712000-00005

subject

Has Abstract

pub_date

1997-12-01 00:00:00

pages

1135-47

issue

12

eissn

0143-3636

issn

1473-5628

journal_volume

18

pub_type

杂志文章
  • Acute effect of 3-(4-acetamido)-butyrril-lorazepam (DDS2700) on brain function assessed by PET at rest and during attentive tasks.

    abstract::The aim of this study was to assess, by positron emission tomography (PET), the effect on cerebral functional activity of a new lorazepam-gamma-aminobutyric acid (GABA) conjugate [3-(4-acetamido)-butyrril lorazepam (DDS2700)]. Ten healthy volunteers were studied by PET and [18F]fluoro-deoxy-D-glucose ([18F]FDG) under ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200104000-00008

    authors: Moresco RM,Tettamanti M,Gobbo C,Del Sole A,Ravasi L,Messa C,Paulesu E,Lucignani G,Perani D,Fazio F

    更新日期:2001-04-01 00:00:00

  • Radionuclide limb blood flow in peripheral vascular disease: a review of 1100 measurements.

    abstract::Radionuclide limb blood flow measurements using 99Tcm-labelled human serum albumin and a gamma camera have been performed on normal volunteers and on patients with suspected or confirmed peripheral arterial disease. The normal range of flow was found to be 10.0-22.3 ml per 100 ml tissue per min. Flow in the symptomati...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199110000-00003

    authors: Parkin A,Robinson PJ,Martinez D,Wilkinson D,Kester RC

    更新日期:1991-10-01 00:00:00

  • Different methods for the detection of small changes in uptake between single-photon emission computed tomography (SPECT) examinations: 99mTc-sestamibi in chemotherapy for breast tumours.

    abstract:AIM:This study was undertaken to evaluate different methods for the detection of small changes in uptake between single-photon emission computed tomography (SPECT) examinations in the same individual. No standard exists for making digital evaluations at single-photon examinations. For this purpose, we employed a patien...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/01.mnm.0000202866.97787.45

    authors: Jacobsson H,Wilczek B,Bergh J,von Schoultz E,Eriksson E,Larsson SA

    更新日期:2006-04-01 00:00:00

  • Simultaneous assessment of regional adrenergic activity and perfusion with 123I-MIBG and 201Tl in congestive heart failure.

    abstract::Simultaneous assessment of regional adrenergic activity and perfusion with 123I-meta-iodobenzylguanidine (123I-MIBG) and 201Tl in various organs was performed in 13 patients with congestive heart failure (CHF) and 13 subjects without heart failure. In order to reduce the crosstalk of 201Tl to the 123I energy window to...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199603000-00009

    authors: Seto H,Shimizu M,Nozawa T,Yoshida N,Inagaki S,Kageyama M,Kakishita M

    更新日期:1996-03-01 00:00:00

  • Radioimmunolocalization and selective delivery of radiation in a rat model system: comparison of intact and fragmented antibody.

    abstract::Monoclonal antibody (MoAb) fragments are known to have advantages over intact immunoglobulins for radioimmunoscintigraphy. It is less clear whether they are as effective in the delivery of radioimmunotherapy. The imaging and dosimetric properties of an intact MoAb, K-1-21, reactive against human kappa light chains (LC...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:

    authors: Walker KZ,Seymour-Munn K,Towson JE,Axiak SM,Raison RL,Bautovitch GJ,Morris J,Basten A

    更新日期:1988-07-01 00:00:00

  • Pretargeted gamma imaging of murine metastatic melanoma lung lesions with bispecific antibody and radiolabeled polymer drug conjugates.

    abstract:INTRODUCTION:Bispecific monoclonal antibodies (bsMAbs) have been developed as a pretargeting tool to reduce background activity, thereby increasing target to background (T : B) ratios. To enhance visualization of small lesions in vivo, we have used the pretargeting approach of bsMAb and negatively charged polymers radi...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e32834af77b

    authors: Gada KS,Patil V,Panwar R,Majewski S,Tekabe Y,Khaw BA

    更新日期:2011-12-01 00:00:00

  • The role of positron emission tomography with fluorine-18-deoxyglucose in identifying colorectal cancer metastases to liver.

    abstract::Liver metastasis is a common consequence of colorectal carcinoma. Early and accurate detection of liver metastasis is crucial for a decision about partial hepatectomy, which is considered a standard and potentially curative therapy in such a setting. The presence of extrahepatic metastases will exclude surgical resect...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200009000-00002

    authors: Zhuang H,Sinha P,Pourdehnad M,Duarte PS,Yamamoto AJ,Alavi A

    更新日期:2000-09-01 00:00:00

  • Semi-quantitative assessment of 99Tcm-sestamibi uptake in lung cancer: relationship with clinical response to chemotherapy.

    abstract::The objectives of this study were to measure semi-quantitatively uptake of 99Tcm-sestamibi (99Tcm-MIBI) by tumour tissue in patients with lung cancer and to investigate its relationship with clinical response to chemotherapy. 99Tcm-MIBI single photon emission tomography was performed at the time of diagnosis in 31 pat...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199711000-00013

    authors: Ceriani L,Giovanella L,Bandera M,Beghe B,Ortelli M,Roncari G

    更新日期:1997-11-01 00:00:00

  • Quantitation of renal function with 99Tcm-DMSA. A comparison with creatinine clearance in children with single kidney.

    abstract::To study the accuracy of renal function quantification with 99Tcm-DMSA we compared DMSA renal uptake and creatinine clearance in 16 cases of children with single kidney. The age of the patients ranged from two months to fourteen years. Creatinine clearance was normalized to 1.73 m2. DMSA uptake was measured 7 h after ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198511000-00009

    authors: Baillet G,Gagnadoux MF,De Vernejoul P,Broyer M

    更新日期:1985-11-01 00:00:00

  • Pulmonary involvement in Behçet's disease: evaluation of 123 I-MIBG retention.

    abstract::Pulmonary involvement in Behçet's disease (BD) is reported to indicate poor prognosis and high mortality. Our aim was to evaluate the pulmonary vascular status in BD. As 123I-meta-iodobenzylguanidine (123I-MIBG) shares the same uptake, storage and release mechanisms as norepinephrine, associated with the functional st...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200110000-00005

    authors: Unlü M,Akincioglu C,Yamaç K,Onder M

    更新日期:2001-10-01 00:00:00

  • Patient and tumor characteristics predictive of an elevated hepatopulmonary shunt fraction before radioembolization of hepatic tumors.

    abstract:OBJECTIVE:To determine whether any patient or hepatic tumor characteristics are predictive of hepatopulmonary shunt fraction when performed before radioembolization. MATERIALS AND METHODS:A retrospective review was performed on 190 patients who underwent preradioembolization hepatic arteriography with calculation of h...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000528

    authors: Yerubandi V,Ronald J,Howard BA,Suhocki PV,James OG,Wong TZ,Kim CY

    更新日期:2016-09-01 00:00:00

  • Double-tracer SPECT in patients with AIDS encephalopathy: a comparison of 123I-IMP with 99Tcm-HMPAO.

    abstract::Single photon emission computed tomography (SPECT) using N-isopropyl-p-(123I)iodoamphetamine (123I-IMP) and 99Tcm-hexamethylpropyleneamine oxime (99Tcm-HMPAO) was performed in 25 patients with different clinical stages of AIDS encephalopathy. The average interval between the two examinations was 7 days. In 15 of the 2...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:

    authors: Pohl P,Riccabona G,Hilty E,Deisenhammer F,Rösslér H,Zangerle R,Gerstenbrand F

    更新日期:1992-08-01 00:00:00

  • A routine method for using sodium iodide to stabilize sodium pertechnetate [99Tcm] dispensed for the preparation of 99Tcm-exametazime.

    abstract::When preparing 99Tcm-exametazime, it is important to use sodium 99Tcm-pertechnetate that is less than 2 h old. The addition of sodium iodide (NaI) to 99Tcm-pertechnetate is known to extend this time to 6 h. This paper describes a technique for implementing this in routine practice. Sterile kits consisting of 440 micro...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199205000-00003

    authors: Millar AM

    更新日期:1992-05-01 00:00:00

  • Effect of administered activity on precision in the assessment of renal function using gamma camera renography.

    abstract::Split and total renal function are commonly assessed from time-activity curves obtained from gamma camera renography with 99Tcm-diethylenetriamine pentaacetate (99Tcm-DTPA) and 99Tcm-mercaptoacetyl-triglycine (99Tcm-MAG3). The impact of the statistical noise associated with these curves on the total precision in split...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199704000-00174

    authors: Moonen M,Jacobsson L

    更新日期:1997-04-01 00:00:00

  • Pre-surgical identification of epileptogenic areas in temporal lobe epilepsy by 123I-iomazenil SPECT: a comparison with IMP SPECT and FDG PET.

    abstract:OBJECTIVES:The aim of this study was to evaluate the usefulness of (123)I-iomazenil (IMZ) single photon emission computed tomography (SPECT) for the pre-surgical identification of epileptogenic areas in patients with temporal lobe epilepsy and to compare the results with those of (123)I-IMP SPECT and (18)Fluorodeoxyglu...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/01.mnm.0000243380.79872.32

    authors: Kaneko K,Sasaki M,Morioka T,Koga H,Abe K,Sawamoto H,Ohya N,Yoshiura T,Mihara F,Honda H

    更新日期:2006-11-01 00:00:00

  • Scintigraphic patterns of lymphocele in post-renal transplant.

    abstract::Lymphocele is a common cause of fluid collection in post-renal transplant patients. Most of these patients are routinely followed up with 99mTc diethylenetriaminepentaacetate renal dynamic scintigraphy. The present study retrospectively reviews the range of findings with renal dynamic scintigraphy in documented lympho...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200305000-00008

    authors: Kumar R,Bharathi Dasan J,Choudhury S,Guleria S,Padhy AK,Malhotra A

    更新日期:2003-05-01 00:00:00

  • Acute myocardial infarction delineated by noninvasive thallium-201/technetium-99m pyrophosphate tomography.

    abstract::The purpose of this study was to validate different scintigraphic approaches for assessing acute myocardial infarctions. 201Tl, 99Tcm pyrophosphate (PPi) and combined 201Tl/99Tcm PPi tomograms were evaluated in 115 consecutive patients, in 85 of whom clinical examination revealed acute myocardial infarction. The overa...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199009000-00005

    authors: Krause T,Joseph A,Kutzner C,Kasper W,Schuemichen C,Just H,Moser E

    更新日期:1990-09-01 00:00:00

  • Low-dose computed tomography scans with automatic exposure control for patients of different ages undergoing cardiac PET/CT and SPECT/CT.

    abstract:PURPOSE:This study aimed to evaluate the efficacy of automatic exposure control (AEC) in order to optimize low-dose computed tomography (CT) protocols for patients of different ages undergoing cardiac PET/CT and single-photon emission computed tomography/computed tomography (SPECT/CT). METHODS:One PET/CT and one SPECT...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000679

    authors: Yang CC,Yang BH,Tu CY,Wu TH,Liu SH

    更新日期:2017-06-01 00:00:00

  • Improving radiopharmaceutical supply chain safety by implementing bar code technology.

    abstract::The aim of this study was to describe and evaluate an approach for improving radiopharmaceutical supply chain safety by implementing bar code technology. We first evaluated the current situation of our radiopharmaceutical supply chain and, by means of the ALARM protocol, analysed two dispensing errors that occurred in...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000177

    authors: Matanza D,Hallouard F,Rioufol C,Fessi H,Fraysse M

    更新日期:2014-11-01 00:00:00

  • Radiation alarm at an airport after radioiodine therapy.

    abstract:BACKGROUND:Screening for radioactive material at borders may become more widely introduced in order to prevent illegal transport. All the alarms at Vienna airport so far have been due to recent applications of radionuclides for medical reasons. METHODS:We report a patient who unexpectedly experienced this problem afte...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200501000-00011

    authors: Sinzinger H,Aiginger P,Neumann I,Havlik E

    更新日期:2005-01-01 00:00:00

  • Quantifying the value of diagnostic tests.

    abstract::This paper considers the different statistics that can be derived from studies on the value of diagnostic tests. Well-accepted quantities, such as sensitivity and specificity, are reviewed and the value of the likelihood ratio in communicating particular test results is highlighted. A new quantity, the 'diagnostic val...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章,评审

    doi:10.1097/00006231-199810000-00010

    authors: Lloyd JJ,Talbot PR,Lawson RS

    更新日期:1998-10-01 00:00:00

  • The relation between striatal dopamine D2/D3 receptor availability and sleep quality in healthy adults.

    abstract:PURPOSE:Increasing evidence, primarily from animal studies and patients with compromised neurotransmitter systems, indicates a possibly important role for dopamine in modulating sleep. We therefore conducted this study to explore the relation between sleep and dopamine in healthy adults. METHODS:We used the Pittsburgh...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e3280bad8b6

    authors: Lee BF,Chiu NT,Kuang Yang Y,Lin Chu C

    更新日期:2007-05-01 00:00:00

  • 99Tcm-MAG3 for quantitation of differential renal function.

    abstract::We studied two different methods for the evaluation of differential renal function in a group of 100 patients with various kidney disorders whose effective renal plasma flow (ERPF) had been calculated previously by single 125I-orthoiodohippurate (OIH) injection and multiple blood sampling. Patients were divided into t...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198910000-00008

    authors: Llamas-Elvira JM,Martinez-Paredes M,Jimenez-Heffernan A,Sopena R,Requena MJ,Gonzalez FM,Torres M,Mateo A

    更新日期:1989-10-01 00:00:00

  • Accuracy of 18F-FDG PET-CT in triaging lung cancer patients with suspected brain metastases for MRI.

    abstract:OBJECTIVE:Brain metastases are common in lung cancer. Whole-body 2-deoxy-2-[fluorine-18]fluoro-D-glucose ([F]FDG) PET/computed tomography (CT) is used for general staging, but MRI is the best modality for characterizing brain abnormalities. We aimed to determine whether PET/CT is suitable for selecting patients for MRI...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000371

    authors: Hjorthaug K,Højbjerg JA,Knap MM,Tietze A,Haraldsen A,Zacho HD,Kramer SM,Borghammer P

    更新日期:2015-11-01 00:00:00

  • Estimation of ascitic fluid volume using 99Tcm labelled macroaggregated albumin.

    abstract::We have assessed the usefulness of a radionuclide dilution method for estimation of ascitic fluid volume. 99Tc(m) macroaggregated albumin (10 MBq) was injected into the peritoneal fluid. Multiple samples were taken using a trocath peritoneal dialysis catheter over a 4-h period. Blood samples were taken at the same tim...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/00006231-200012000-00009

    authors: Notghi A,Williams NR,Kehoe S,Smith NB,Harding LK

    更新日期:2000-12-01 00:00:00

  • Deficiencies in product labelling instructions and quality control directions for 99mTc radiopharmaceuticals.

    abstract:OBJECTIVE:The aim of the study was to identify deficiencies in product labelling instructions for reconstitution and in the quality control directions detailed in the technical leaflets (TLs) or summary product characteristic (SPC) sheets of commonly used technetium labelling cold kits. MATERIALS AND METHODS:The recon...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000030

    authors: Buroni FE,Lodola L,Persico MG,Aprile C

    更新日期:2014-02-01 00:00:00

  • The appearance of the pyramidal lobe on thyroid scintigraphy.

    abstract::The standard nuclear medicine textbooks describe the pyramidal lobe of the thyroid as arising from the upper part of the thyroid lobes. Anatomy and surgical texts however describe it as a thyroglossal tract remnant and state that it arises from the isthmus. Review of 150 thyroid scintigrams confirms that on scintigrap...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198403000-00006

    authors: Savage PE,Khan O,Grover S,Ott R,McCready VR

    更新日期:1984-03-01 00:00:00

  • An assessment of wall motion, perfusion and glucose metabolism in recent myocardial infarction: a comparison in patients with and without revascularization.

    abstract::The aim of this study was to compare the extent and severity of wall motion abnormalities, perfusion and glucose metabolism, in recent myocardial infarction in patients with and without revascularization. Forty-nine patients were studied (82% men; mean age 58 years) by using echocardiography, 201Tl single photon emiss...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/00006231-200311000-00006

    authors: González P,Massardo T,Coll C,Redondo F,Yovanovich J,Jofré J,Chamorro H,Humeres P,Sierralta P,Ramírez A,Kunstmann S,López H,Aramburú I,Brugère S

    更新日期:2003-11-01 00:00:00

  • The use of 18F-fluoromethylcholine PET/CT in differentiating focal nodular hyperplasia from hepatocellular adenoma: a prospective study of diagnostic accuracy.

    abstract:INTRODUCTION:Diagnosis of focal nodular hyperplasia (FNH) and hepatocellular adenoma (HCA) using conventional imaging techniques can be difficult; however, it is important to differentiate between them as these benign liver tumors require different therapeutic strategies. The aim of our study was to prospectively evalu...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/MNM.0b013e32835afe62

    authors: Bieze M,Bennink RJ,El-Massoudi Y,Phoa SS,Verheij J,Beuers U,van Gulik TM

    更新日期:2013-02-01 00:00:00

  • Aspirin renography in the diagnosis of renovascular hypertension: a comparative study with captopril renography.

    abstract::Captopril renography is used for the non-invasive diagnosis of renovascular hypertension, but suffers from the drawbacks of lower sensitivity and false-positive tests due to a fall in blood pressure. Aspirin renography has been proposed as a useful test for evaluation of unilateral renal artery stenoses of moderate de...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200004000-00006

    authors: Maini A,Gambhir S,Singhal M,Kher V

    更新日期:2000-04-01 00:00:00