Duration of Infusion Set Survival in Lipohypertrophy Versus Nonlipohypertrophied Tissue in Patients with Type 1 Diabetes.

Abstract:

BACKGROUND:Improved insulin infusion set survival and faster insulin action are important issues for pump users and for the development of an artificial pancreas. The current recommendation is to change infusion sets every 3 days. Our objectives were to determine the effect of lipohypertrophy (LH) on infusion set survival and continuous glucose monitoring glucose levels. RESEARCH DESIGN AND METHODS:In this multicenter crossover trial, we recruited 20 subjects (age 28.1 ± 9.0 years) with type 1 diabetes (duration 17.5 ± 8.8 years) and an area of lipohypertrophied tissue >3 cm. Subjects alternated weekly wearing a Teflon infusion set in an area of either LH or non-LH for 4 weeks. Sets were changed after (a) failure or (b) surviving 7 days of use. RESULTS:The least-squares mean duration of infusion set survival for sets that lasted <7 days in lipohypertrophied tissue was 4.31 days compared with 4.12 days in nonlipohypertrophied tissue (P = 0.71). The average duration of set survival for individual subjects ranged from 2.2 to 7.0 days. Infusion sets in lipohypertrophied tissue failed due to hyperglycemia in 35% of subjects compared with 23% in nonlipohypertrophied tissue (P = 0.22). Both lipohypertrophied and nonlipohypertrophied tissues displayed a general increase in mean daily glucose after the third day of infusion set wear, but daily mean glucose did not differ by tissue type (P > 0.38 on each day). CONCLUSION:LH did not significantly affect infusion set survival or mean glucose. Achieving optimal infusion set performance requires research into factors affecting set survival. Additionally, the recommendation for duration of set change may need to be individualized.

journal_name

Diabetes Technol Ther

authors

Karlin AW,Ly TT,Pyle L,Forlenza GP,Messer L,Wadwa RP,DeSalvo DJ,Payne SL,Hanes S,Clinton P,Maahs DM,Buckingham B

doi

10.1089/dia.2015.0432

subject

Has Abstract

pub_date

2016-07-01 00:00:00

pages

429-35

issue

7

eissn

1520-9156

issn

1557-8593

journal_volume

18

pub_type

杂志文章,多中心研究,随机对照试验
  • Evaluating rate of change as an index of glycemic variability, using continuous glucose monitoring data.

    abstract:BACKGROUND:There is no consensus as to the best method to assess glycemic variability from continuous glucose monitoring (CGM) data. Rate of change has been suggested as a preferred method of assessing glycemic variability, but this assertion has not been validated. METHODS:Forty-eight hours of CGM data were analyzed ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究

    doi:10.1089/dia.2010.0215

    authors: Whitelaw BC,Choudhary P,Hopkins D

    更新日期:2011-06-01 00:00:00

  • Effectiveness of Automated Insulin Management Features of the MiniMed® 640G Sensor-Augmented Insulin Pump.

    abstract:BACKGROUND:Automated insulin management features of the MiniMed® 640G sensor-augmented pump system include suspension in response to predicted low sensor glucose (SG) values ("suspend before low"), suspension in response to existing low SG values ("suspend on low"), and automatic restarting of basal insulin delivery up...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2016.0216

    authors: Zhong A,Choudhary P,McMahon C,Agrawal P,Welsh JB,Cordero TL,Kaufman FR

    更新日期:2016-10-01 00:00:00

  • The impact of initiating biphasic human insulin 30 therapy in type 2 diabetes patients after failure of oral antidiabetes drugs.

    abstract:BACKGROUND:The present study evaluated the efficacy of biphasic human insulin 30 (BHI 30) in type 2 diabetes patients who had failed in therapy with two or more oral antidiabetes drugs (OADs). METHODS:This open-label, nonrandomized, 4-month, multicenter, clinical observational study was conducted in Shanghai, China. A...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究

    doi:10.1089/dia.2011.0168

    authors: Gu Y,Hou X,Zhang L,Pan J,Cai Q,Bao Y,Jia W

    更新日期:2012-03-01 00:00:00

  • Differences in exhaled gas profiles between patients with type 2 diabetes and healthy controls.

    abstract:AIMS:Recent advances in analytical technology allow the detection of several hundred volatile organic compounds (VOCs) in human exhaled air, many of which reflect unidentified endogenous pathways. This study was performed to determine whether a breath gas analysis using proton transfer reaction-mass spectrometry (PTR-M...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2009.0181

    authors: Greiter MB,Keck L,Siegmund T,Hoeschen C,Oeh U,Paretzke HG

    更新日期:2010-06-01 00:00:00

  • Physiological and therapeutic roles of peroxisome proliferator-activated receptors.

    abstract::The peroxisome proliferator-activated receptors (PPARs) are a group of nuclear receptor isoforms, including PPARgamma, PPARalpha, and PPARdelta, encoded by different genes. PPARs are ligand-regulated transcription factors that control gene expression by binding to specific response elements (PPREs) within promoters. P...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/15209150260007381

    authors: Berger J,Wagner JA

    更新日期:2002-01-01 00:00:00

  • Cutaneous blood perfusion as a perturbing factor for noninvasive glucose monitoring.

    abstract::It is widely accepted that noninvasive glucose monitoring (NIGM) has the potential to revolutionize diabetes therapy. However, current approaches to NIGM studied to date have not yet demonstrated a level of acceptable functionality to allow real-time use, beyond restricted fields of application. A number of reviews ha...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2009.0095

    authors: Caduff A,Talary MS,Zakharov P

    更新日期:2010-01-01 00:00:00

  • Mitigating Reductions in Glucose During Exercise on Closed-Loop Insulin Delivery: The Ex-Snacks Study.

    abstract:OBJECTIVE:To assess whether snacking could be used with closed-loop (CL) insulin delivery to avoid exercise-induced reductions in plasma glucose (PG), as well as elevations in PG at the end of exercise. RESEARCH DESIGN AND METHODS:Twelve type 1 diabetes (T1D) subjects (age 13-36 years, duration 10.7 ± 8.4 years, A1c 7...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2016.0311

    authors: Patel NS,Van Name MA,Cengiz E,Carria LR,Tichy EM,Weyman K,Weinzimer SA,Tamborlane WV,Sherr JL

    更新日期:2016-12-01 00:00:00

  • Evaluation of a Nurse-Managed Insulin Infusion Protocol.

    abstract:BACKGROUND:The purpose of this study was to evaluate the performance of an insulin infusion protocol targeting a blood glucose (BG) level of 140-180 mg/dL and to characterize protocol adherence. MATERIALS AND METHODS:This was a retrospective observational cohort study including patients for whom the protocol was order...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2015.0046

    authors: Passarelli AJ,Gibbs H,Rowden AM,Efird L,Zink E,Mathioudakis N

    更新日期:2016-02-01 00:00:00

  • Lasers and diabetic retinopathy: the art of gentle destruction.

    abstract::Laser retinal photocoagulation represents the primary therapy for the potentially blinding manifestations of diabetic retinopathy. Advances in laser therapy for diabetic eye disease have arisen from the convergence of laser technology and clinical ophthalmology. In this review, the basis of laser therapy in diabetic r...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/152091599317396

    authors: Petrovic V,Bhisitkul RB

    更新日期:1999-07-01 00:00:00

  • Description and preliminary evaluation of a Multiagent Intelligent Dosing System (MAIDS) to manage combination insulin-oral agent therapy in type 2 diabetes.

    abstract:BACKGROUND:Computer decision support systems are potentially effective methods for adjusting insulin, but current models do not take into account simultaneous changes of more than one agent. We describe the development of the Multiagent Intelligent Dosing System (MAIDS, Dimensional Dosing Systems, Wexford, PA) for pred...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2005.7.937

    authors: Cook CB,McMichael JP,Dunbar VG,Lieberman R

    更新日期:2005-12-01 00:00:00

  • A Feasibility Study of Paired Continuous Glucose Monitoring Intrapartum and in the Newborn in Pregnancies Complicated by Type 1 Diabetes.

    abstract:AIM:To describe the continuous glucose monitoring (CGM) profiles of type 1 diabetes (T1D) offspring in the early neonatal period and its association with maternal intrapartum glucose control. METHODS:A prospective observational study of T1D pregnant women and their neonatal offspring. Women had a CGM sensor inserted 2...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0221

    authors: Stewart ZA,Thomson L,Murphy HR,Beardsall K

    更新日期:2019-01-01 00:00:00

  • Nocturnal continuous glucose monitoring: accuracy and reliability of hypoglycemia detection in patients with type 1 diabetes at high risk of severe hypoglycemia.

    abstract:BACKGROUND:A reliable method to detect biochemical nocturnal hypoglycemia is highly needed, especially in patients with recurrent severe hypoglycemia. We evaluated reliability of nocturnal continuous glucose monitoring (CGM) in patients with type 1 diabetes at high risk of severe hypoglycemia. PATIENTS AND METHODS:Sev...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1089/dia.2013.0004

    authors: Bay C,Kristensen PL,Pedersen-Bjergaard U,Tarnow L,Thorsteinsson B

    更新日期:2013-05-01 00:00:00

  • Interactive educational diabetes/insulin tutorial at www.2aida.info.

    abstract::The World Wide Web now hosts a multitude of diabetes educational materials in various formats. Of particular interest is the diabetes/insulin tutorial available at the AIDA Website (accessible directly at: www.2aida.info). The tutorial combines textual or "static" information with an interactive diabetes simulator-AID...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2006.8.126

    authors: Reed K,Lehmann ED

    更新日期:2006-02-01 00:00:00

  • Estimated Lifetime Economic Burden of Type 1 Diabetes.

    abstract:: Background: The financial strain of type 1 diabetes on the United States health care system, patients, and employers underscores the importance of developing novel treatments for the disease. This study estimated the lifetime economic burden attributable to type 1 diabetes...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2019.0398

    authors: Sussman M,Benner J,Haller MJ,Rewers M,Griffiths R

    更新日期:2020-02-01 00:00:00

  • Continuous subcutaneous insulin infusion and multiple dose of insulin regimen display similar patterns of blood glucose excursions in pediatric type 1 diabetes.

    abstract:BACKGROUND:Continuous subcutaneous insulin infusion (CSII) is believed to decrease glycemic variability and clinical hypoglycemia compared with the multiple daily insulin (MDI) regimen. To compare the indices of glycemic instability between CSII and MDI, we analyzed the continuous glucose monitoring system (CGMS) (Medt...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章

    doi:10.1089/dia.2005.7.587

    authors: Alemzadeh R,Palma-Sisto P,Parton EA,Holzum MK

    更新日期:2005-08-01 00:00:00

  • Safety Evaluation of the MiniMed 670G System in Children 7-13 Years of Age with Type 1 Diabetes.

    abstract:OBJECTIVE:To evaluate the safety of in-home use of the MiniMed™ 670G system with SmartGuard™ technology in children with type 1 diabetes (T1D). METHODS:Participants (N = 105, ages 7-13 years, mean age 10.8 ± 1.8 years) were enrolled at nine centers (eight in the United States and one in Israel) and completed a 2-week ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0264

    authors: Forlenza GP,Pinhas-Hamiel O,Liljenquist DR,Shulman DI,Bailey TS,Bode BW,Wood MA,Buckingham BA,Kaiserman KB,Shin J,Huang S,Lee SW,Kaufman FR

    更新日期:2019-01-01 00:00:00

  • Personal glycation factors and calculated HbA1c for diabetes management: Real-world data from the DPV registry.

    abstract::Background Glycated hemoglobin A1c (HbA1c) is a key biomarker in the glycemic management of individuals with diabetes but the relationship with glucose levels can be variable. A recent kinetic model has described a calculated HbA1c (cHbA1c) that is individual-specific. Our aim was to validate the routine clinical use ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2020.0553

    authors: Xu Y,Grimsmann JM,Karges B,Hofer SE,Danne T,Holl RW,Ajjan RA,Dunn TD

    更新日期:2021-01-04 00:00:00

  • In vivo glucose monitoring using dual-wavelength polarimetry to overcome corneal birefringence in the presence of motion.

    abstract:OBJECTIVE:Over the past 35 years considerable research has been performed toward the investigation of noninvasive and minimally invasive glucose monitoring techniques. Optical polarimetry is one noninvasive technique that has shown promise as a means to ascertain blood glucose levels through measuring the glucose conce...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2012.0070

    authors: Pirnstill CW,Malik BH,Gresham VC,Coté GL

    更新日期:2012-09-01 00:00:00

  • Noninvasive continuous glucose monitoring using photoacoustic technology-results from the first 62 subjects.

    abstract:BACKGROUND:Continuous glucose monitoring is a useful tool for the achievement of improved glucose control in patients with diabetes. We tested the ability of a novel noninvasive continuous glucose monitor to track glucose excursions. METHODS:The novel noninvasive Aprise sensor (Glucon Inc., Boulder, CO) utilizes the p...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章

    doi:10.1089/dia.2006.0059

    authors: Weiss R,Yegorchikov Y,Shusterman A,Raz I

    更新日期:2007-02-01 00:00:00

  • Clinical studies on chromium picolinate supplementation in diabetes mellitus--a review.

    abstract::Chromium (Cr) picolinate (CrPic) is a widely used nutritional supplement for optimal insulin function. A relationship among Cr status, diabetes, and associated pathologies has been established. Virtually all trials using CrPic supplementation for subjects with diabetes have demonstrated beneficial effects. Thirteen of...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2006.8.677

    authors: Broadhurst CL,Domenico P

    更新日期:2006-12-01 00:00:00

  • Randomized Evaluation of Glycemic Control in the Medical Intensive Care Unit Using Real-Time Continuous Glucose Monitoring (REGIMEN Trial).

    abstract:BACKGROUND AND OBJECTIVE:Hyperglycemia occurs commonly in patients admitted to medical intensive care units (MICUs). Whether real-time (RT) continuous glucose monitoring (CGM) improves glycemic control and variability and reduces hypoglycemia in severely ill MICU patients with an Acute Physiology and Chronic Health Eva...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1089/dia.2015.0151

    authors: De Block CE,Gios J,Verheyen N,Manuel-y-Keenoy B,Rogiers P,Jorens PG,Scuffi C,Van Gaal LF

    更新日期:2015-12-01 00:00:00

  • A tale of two compartments: interstitial versus blood glucose monitoring.

    abstract::Self-monitoring of blood glucose was described as one of the most important advancements in diabetes management since the invention of insulin in 1920. Recent advances in glucose sensor technology for measuring interstitial glucose concentrations have challenged the dominance of glucose meters in diabetes management, ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2009.0002

    authors: Cengiz E,Tamborlane WV

    更新日期:2009-06-01 00:00:00

  • Continuous glucose monitoring pilot in low-income type 1 diabetes patients.

    abstract:BACKGROUND:Continuous glucose monitoring (CGM) has been shown to be a valuable tool to improve glycemic control in patients with diabetes. The objective of this pilot study was to develop and implement CGM in an existing diabetes clinic for low-income patients on multiple daily injections. SUBJECTS AND METHODS:This wa...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2013.0072

    authors: Sequeira PA,Montoya L,Ruelas V,Xing D,Chen V,Beck R,Peters AL

    更新日期:2013-10-01 00:00:00

  • The design and performance of the exubera pulmonary insulin delivery system.

    abstract::The Exubera system (Pfizer, New York, NY/Nektar Therapeutics, San Carlos, CA) is an integration of five major new technologies: protein formulation, powder processing, powder filling, drug packaging, and delivery device. The product provides a simple interface, where the patient interacts only with the delivery device...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2007.0222

    authors: Harper NJ,Gray S,De Groot J,Parker JM,Sadrzadeh N,Schuler C,Schumacher JD,Seshadri S,Smith AE,Steeno GS,Stevenson CL,Taniere R,Wang M,Bennett DB

    更新日期:2007-06-01 00:00:00

  • A recent survey confirms the efficacy and the safety of implanted insulin pumps during long-term use in poorly controlled type 1 diabetes patients.

    abstract:BACKGROUND:This article reports a prolonged trial with insulin pumps implanted in patients with type 1 diabetes showing poor glucose control and a high rate of complications. METHODS:We reviewed data from 181 patients undergoing implanted insulin pump therapy. Analysis included hemoglobin A1c (HbA1c) values, body weig...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2010.0209

    authors: Schaepelynck P,Renard E,Jeandidier N,Hanaire H,Fermon C,Rudoni S,Catargi B,Riveline JP,Guerci B,Millot L,Martin JF,Sola A,EVADIAC Group.

    更新日期:2011-06-01 00:00:00

  • Electroencephalography to assess motor control during balance tasks in people with diabetes.

    abstract:BACKGROUND:Balance is sensed through peripheral and central receptors and mediated by central control through the brain and spinal cord. Although some evidence exists as to the areas of the brain involved and how processing of data occurs in young individuals, nothing has been published on people with diabetes. The pur...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2012.0152

    authors: Petrofsky JS,Alshammari F,Lee H,Yim JE,Bains G,Khowailed IA,Deshpande PP,Potnis P,Tse F,Cavalcanti P

    更新日期:2012-11-01 00:00:00

  • Reduced weight gain with insulin detemir compared to NPH insulin is not explained by a reduction in hypoglycemia.

    abstract:BACKGROUND:Weight gain often occurs when insulin therapy is initiated. The long-acting insulin analog insulin detemir has been shown to be effective and well tolerated when used in basal-bolus regimens or as an add-on to oral antidiabetic drugs (OADs) and causes less weight gain than other insulins. The aim of this exp...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1089/dia.2008.0282

    authors: Davies MJ,Derezinski T,Pedersen CB,Clauson P

    更新日期:2008-08-01 00:00:00

  • Design and Clinical Evaluation of the Interoperable Artificial Pancreas System (iAPS) Smartphone App: Interoperable Components with Modular Design for Progressive Artificial Pancreas Research and Development.

    abstract:BACKGROUND:There is an unmet need for a modular artificial pancreas (AP) system for clinical trials within the existing regulatory framework to further AP research projects from both academia and industry. We designed, developed, and tested the interoperable artificial pancreas system (iAPS) smartphone app that can int...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0278

    authors: Deshpande S,Pinsker JE,Zavitsanou S,Shi D,Tompot R,Church MM,Andre C,Doyle FJ 3rd,Dassau E

    更新日期:2019-01-01 00:00:00

  • Accuracy of continuous glucose monitoring during exercise in type 1 diabetes pregnancy.

    abstract:BACKGROUND:Performance of continuous glucose monitors (CGMs) may be lower when glucose levels are changing rapidly, such as occurs during physical activity. Our aim was to evaluate accuracy of a current-generation CGM during moderate-intensity exercise in type 1 diabetes (T1D) pregnancy. SUBJECTS AND METHODS:As part o...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2012.0292

    authors: Kumareswaran K,Elleri D,Allen JM,Caldwell K,Nodale M,Wilinska ME,Amiel SA,Hovorka R,Murphy HR

    更新日期:2013-03-01 00:00:00

  • Behavioral Patterns and Associations with Glucose Control During 12-Week Randomized Free-Living Clinical Trial of Day and Night Hybrid Closed-Loop Insulin Delivery in Adults with Type 1 Diabetes.

    abstract:OBJECTIVES:We evaluated patterns of meal intake, insulin bolus delivery, and fingerstick glucose measurements during hybrid closed-loop and sensor-augmented pump (SAP) therapy, including associations with glucose control. METHODS:Data were retrospectively analyzed from pump-treated adults with type 1 diabetes who unde...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2016.0307

    authors: Emami A,Willinska ME,Thabit H,Leelarathna L,Hartnell S,Dellweg S,Benesch C,Mader JK,Holzer M,Kojzar H,Pieber TR,Arnolds S,Evans ML,Hovorka R

    更新日期:2017-07-01 00:00:00