Abstract:
BACKGROUND:Weight gain often occurs when insulin therapy is initiated. The long-acting insulin analog insulin detemir has been shown to be effective and well tolerated when used in basal-bolus regimens or as an add-on to oral antidiabetic drugs (OADs) and causes less weight gain than other insulins. The aim of this exploratory analysis was to investigate any correlations between weight change and occurrence of hypoglycemia with NPH insulin and insulin detemir. METHODS:The analysis was based on a 26-week, randomized, multicenter, open-label, parallel-group trial in which glycemic control, hypoglycemia, and weight change were compared between insulin detemir and NPH insulin. A total of 476 insulin-naive patients with type 2 diabetes treated with one or two OADs added insulin detemir (n=237) or NPH insulin (n=239) morning and evening to their current oral treatment. Weight gain data from this study were analyzed as a function of hypoglycemia frequency. RESULTS:Both groups achieved excellent glycosylated hemoglobin control (insulin detemir, 6.6%; NPH insulin, 6.5% [difference not significant]). Weight gain with insulin detemir was less than half that of NPH insulin (1.2 vs. 2.8 kg, respectively [P<0.001]), and the overall risk of hypoglycemia was 47% lower with insulin detemir (P<0.001). No significant relationship between hypoglycemia and weight gain was seen with insulin detemir (P=0.2), while a statistically significant correlation was found for NPH insulin (P=0.003). CONCLUSIONS:Hypoglycemia is predictive of weight gain with NPH insulin, but the same relationship is not seen with insulin detemir. It is therefore likely that the weight-sparing effect of insulin detemir involves other mechanisms.
journal_name
Diabetes Technol Therjournal_title
Diabetes technology & therapeuticsauthors
Davies MJ,Derezinski T,Pedersen CB,Clauson Pdoi
10.1089/dia.2008.0282subject
Has Abstractpub_date
2008-08-01 00:00:00pages
273-7issue
4eissn
1520-9156issn
1557-8593journal_volume
10pub_type
杂志文章,多中心研究,随机对照试验abstract::The transplantation of microencapsulated islets may allow reversal of hyperglycemia in the absence of immunosuppression. Poly-L-lysine (PLL) on capsules may potentiate the fibrotic reaction against implanted capsules. The aims of this study were to investigate how the biocompatibility of such capsules affects their fu...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/152091503322250677
更新日期:2003-01-01 00:00:00
abstract:OBJECTIVE:This study was designed to measure pressure and shear reduction of a novel insole design. METHODS:We compared three multilayer viscoelastic insoles to a novel insole design (Glide-Soft, Xilas Medical, Inc., San Antonio, TX). The bottom pad of each insole was fabricated from firm-density Plastazote [Apex Foot...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2005.7.638
更新日期:2005-08-01 00:00:00
abstract:BACKGROUND:To protect against ischemia, pressure-induced vasodilation (PIV) causes an increase in skin blood flow. Endothelial dysfunction, which is commonly found in older patients and those with diabetes, and global temperatures can affect the resting blood flow in skin, which may reduce the blood flow during and aft...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2009.0097
更新日期:2009-12-01 00:00:00
abstract::Current clinical guidelines for diabetes care encourage self-monitoring of blood glucose (SMBG) to improve glycemic control. Specific protocols remain variable, however, particularly among non-insulin-using patients. This is due in part to efficacy studies that neglect to consider (1) the performance of monitoring equ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2008.0104
更新日期:2008-12-01 00:00:00
abstract::There is a clear role for inflammation in the development of type 2 diabetes and its associated co-morbidities. Circulating inflammatory markers such as C-reactive protein, sialic acid, and interleukin- 6 are all significant independent predictors of disease. A number of nutritional components are hypothesized to modu...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2006.8.45
更新日期:2006-02-01 00:00:00
abstract::Type 2 diabetes is thought to develop as a result of progressive beta-cell dysfunction in the setting of insulin resistance, leading to increased risks of microvascular and macrovascular complications. Type 2 diabetes is currently treated with diet and exercise, followed by oral drug therapy, and finally exogenous ins...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2006.8.385
更新日期:2006-06-01 00:00:00
abstract:BACKGROUND:Relatively little is known about parents' or children's attitudes toward recruitment for, and participation in, studies of new diabetes technologies immediately after diagnosis. This study investigated factors affecting recruitment of participants for studies in newly diagnosed youth with type 1 diabetes. M...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2016.0157
更新日期:2016-09-01 00:00:00
abstract:BACKGROUND:For patients with diabetes, the quality of outpatient glycemic control is readily assessed by hemoglobin A1c. In contrast, standardized measures for assessing the quality of blood glucose (BG) management in hospitalized patients are lacking. Because of recent studies demonstrating the benefits of strict glyc...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2006.8.560
更新日期:2006-10-01 00:00:00
abstract:BACKGROUND:We aimed to assess the effect of continuous subcutaneous insulin infusion (CSII) therapy in patients with "recalcitrant diabetes" whose glycemia had not been controlled adequately with multiple daily injections of insulin or insulin plus oral hypoglycemic agents. PATIENTS AND METHODS:We retrospectively anal...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2009.0066
更新日期:2009-11-01 00:00:00
abstract:BACKGROUND:We assessed the impact of using an automated bolus advisor integrated into a blood glucose meter on the timing and frequency of adjusting insulin therapy parameter settings and whether the availability of this technology would increase blood glucose test strip utilization in diabetes patients treated with mu...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1089/dia.2013.0280
更新日期:2014-05-01 00:00:00
abstract:BACKGROUND:Little information is available regarding glucose fluctuations in postprandial states and during the oral glucose tolerance test (OGTT) in Japanese people with normal glucose tolerance (NGT). METHODS:Glucose profiles of 27 Japanese people were measured for 4 days by using continuous glucose monitoring. A 75...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2008.0083
更新日期:2009-07-01 00:00:00
abstract:BACKGROUND:Accurate and economic detection of nerve damage in diabetes is key to more widespread diagnosis of patients with diabetic peripheral neuropathy (DPN) and painful diabetic neuropathy. This study examined the diagnostic performance of NerveCheck, an inexpensive ($500) quantitative sensory testing (QST) device....
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2016.0279
更新日期:2016-12-01 00:00:00
abstract:BACKGROUND:For patients with type 1 diabetes mellitus, a bihormonal artificial endocrine pancreas system utilizing glucagon and insulin has been found to stabilize glycemic control. However, commercially available formulations of glucagon cannot currently be used in such systems because of physical instability characte...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2014.0047
更新日期:2014-11-01 00:00:00
abstract:BACKGROUND:The optimal treatment of diabetes in pregnancy requires accurate measurement of blood glucose levels, in order to minimize adverse outcomes for both mother and neonate. Self-monitoring of blood glucose is routinely used to measure glycemic control and to assess whether treatment targets are being met; howeve...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,收录出版
doi:10.1089/dia.2015.0104
更新日期:2016-02-01 00:00:00
abstract:: Background: We aimed to explore insulin pump settings in breastfeeding women with type 1 diabetes. Methods: Thirteen unselected breastfeeding women with type 1 diabetes on insulin pump therapy were included consecutively from A...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2019.0280
更新日期:2020-04-01 00:00:00
abstract:BACKGROUND:Diabetes in elderly adults is associated with an increased risk of fall. The aim of study was to determine whether a virtual reality exercise (VRE) program would improve balance, strength, gait, and falls efficacy in elderly adults with diabetes. SUBJECTS AND METHODS:Fifty-five subjects with diabetes mellit...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2013.0050
更新日期:2013-06-01 00:00:00
abstract:BACKGROUND:Continuous glucose monitoring (CGM) has been shown to be a valuable tool to improve glycemic control in patients with diabetes. The objective of this pilot study was to develop and implement CGM in an existing diabetes clinic for low-income patients on multiple daily injections. SUBJECTS AND METHODS:This wa...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2013.0072
更新日期:2013-10-01 00:00:00
abstract:BACKGROUND:Previous studies of aerobic exercise have found lower sensor accuracy during exercise. Whether or not resistance exercise would also be associated with lower sensor accuracy has not yet been examined. This study sought to investigate the accuracy of continuous glucose monitoring sensor values at rest, during...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2012.0182
更新日期:2013-01-01 00:00:00
abstract:BACKGROUND:Persistent use of real-time continuous glucose monitoring (CGM) improves diabetes control in individuals with type 1 diabetes (T1D) and type 2 diabetes (T2D). METHODS:PRECISE II was a nonrandomized, blinded, prospective, single-arm, multicenter study that evaluated the accuracy and safety of the implantable...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究
doi:10.1089/dia.2017.0142
更新日期:2018-03-01 00:00:00
abstract::Thanks to significant improvements in the precision, accuracy, and usability of continuous glucose monitoring (CGM), its relevance in both ambulatory diabetes care and clinical research is increasing. In this study, we address the latter perspective and derive provisional reporting recommendations. CGM systems have be...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2017.0054
更新日期:2017-07-01 00:00:00
abstract:BACKGROUND:The recent availability of a continuous glucose monitor offers the opportunity to match the demands of intensive diabetes management with a period of equally intensive blood glucose monitoring. The present study evaluates the performance of the MiniMed continuous glucose monitoring system (CGMS) in patients ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/152091500316737
更新日期:2000-04-01 00:00:00
abstract::Patients with diabetes play with a double-edged sword when it comes to deciding glucose and A1c target levels. On the one side, tight control has been shown to be crucial in avoiding long-term complications; on the other, tighter control leads to an increased risk of iatrogenic hypoglycemia, which is compounded when h...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2005.7.3
更新日期:2005-02-01 00:00:00
abstract:AIM:To describe the continuous glucose monitoring (CGM) profiles of type 1 diabetes (T1D) offspring in the early neonatal period and its association with maternal intrapartum glucose control. METHODS:A prospective observational study of T1D pregnant women and their neonatal offspring. Women had a CGM sensor inserted 2...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2018.0221
更新日期:2019-01-01 00:00:00
abstract:: Background: Continuous glucose monitoring (CGM) is a method of estimating blood glucose values from those recorded in the interstitial fluid. Because increasingly longer CGM measurements are possible, errors and data loss become more and more likely and potentially more da...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2018.0247
更新日期:2018-12-01 00:00:00
abstract:INTRODUCTION:The ProAct study has shown that a pump switch to the Accu-Chek(®) Combo system (Roche Diagnostics Deutschland GmbH, Mannheim, Germany) in type 1 diabetes patients results in stable glycemic control with significant improvements in glycated hemoglobin (HbA1c) in patients with unsatisfactory baseline HbA1c a...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章,多中心研究
doi:10.1089/dia.2014.0278
更新日期:2015-06-01 00:00:00
abstract::On May 26, 1976, the Food and Drug Administration (FDA) began implementing the Medical Device Amendments to the Federal Food Drug and Cosmetic Act. These amendments give FDA specific authority to regulate "medical devices." Additional authority was provided in the Safe Medical Devices Act of 1990. The pathways to get ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/152091502321118784
更新日期:2002-01-01 00:00:00
abstract:BACKGROUND:Because strict glucose control is important for reducing the complications of diabetes, the self-monitoring of blood glucose is one of the fundamental treatment modalities. Many glucometers have been developed. In the present study, we evaluated a new glucometer: GlucoDr Plus (Allmedicus, Anyang, Gyeonggi-do...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2009.0134
更新日期:2010-04-01 00:00:00
abstract:BACKGROUND:Visual disabilities due to diabetes are on the rise, especially in urban areas of developing countries. Proper health planning will need evidence-based information. STUDY DESIGN AND METHODS:We estimated the prevalence and identified the determinants of eye complications among persons with diabetes screened ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2009.0033
更新日期:2009-09-01 00:00:00
abstract::Diabetic nephropathy is one of the major causes of end-stage renal disease and is often associated with other macrovascular complications such as ischemic heart disease and peripheral vascular disease. Angiotensin converting enzyme inhibitors (ACE-I) and angiotensin II receptor blockers (AIIR) have both been shown to ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/152091502760098456
更新日期:2002-01-01 00:00:00
abstract:BACKGROUND:Computer simulation environments have been used in the development of many artificial pancreas systems. A glucose sensor model is an essential part of these environments, and different models have been proposed. However, not one of these models accounts for drop-outs of sensor readings, a well-known phenomen...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2014.0309
更新日期:2015-06-01 00:00:00