Continuous subcutaneous insulin infusion and multiple dose of insulin regimen display similar patterns of blood glucose excursions in pediatric type 1 diabetes.

Abstract:

BACKGROUND:Continuous subcutaneous insulin infusion (CSII) is believed to decrease glycemic variability and clinical hypoglycemia compared with the multiple daily insulin (MDI) regimen. To compare the indices of glycemic instability between CSII and MDI, we analyzed the continuous glucose monitoring system (CGMS) (Medtronic MiniMed, Northridge, CA) profiles of a group of children with type 1 diabetes mellitus with history of frequent blood glucose (BG) fluctuations and hypoglycemia. PATIENTS AND METHODS:Data from 14 (nine girls, five boys) patients (3.9-16.8 years old) on CSII and 14 age- and sex-matched (nine girls, five boys) patients (3.9-16.0 years old) on MDI with similar glycemic control (hemoglobin A1c: 7.9 +/- 1.0% vs. 7.9 +/- 1.5%) and body mass index (BMI) (20.1 +/- 4.3 vs. 19.9 +/- 4.1 kg/m(2)) were evaluated by the CGMS. Mean BG (MBG), absolute means of daily differences (MODD), mean amplitude of glycemic excursion (MAGE), and number of hypoglycemic events (BG <60 mg/dL) for 48 h were calculated. RESULTS:The MBG, MODD, MAGE, and number and mean duration of hypoglycemia events in the CSII group were similar to those in the MDI group. The MAGE had an inverse correlation with age (CSII: r (2) = 0.52, P = 0.003; MDI: r (2) = 0.29, P < 0.04) and BMI (CSII: r (2) = 0.38, P < 0.02; MDI: r (2) = 0.71, P < 0.0002). However, there was a positive relationship between MAGE and bolus:basal insulin ratio in the CSII (r (2) = 0.28, P < 0.05) and MDI (r (2) = 0.33, P < 0.03) groups. Also, the MAGE had a positive correlation with frequency of hypoglycemic events in the CSII (r (2) = 0.44, P < 0.01) and MDI (r (2) = 0.35, P < 0.03) groups. CONCLUSIONS:The CSII and MDI regimens in children and adolescents with comparable glycemic control displayed similar patterns of glycemic excursions, implying that factors influencing glycemic instability in pediatric type 1 diabetes mellitus appear to be independent of treatment modality.

journal_name

Diabetes Technol Ther

authors

Alemzadeh R,Palma-Sisto P,Parton EA,Holzum MK

doi

10.1089/dia.2005.7.587

keywords:

subject

Has Abstract

pub_date

2005-08-01 00:00:00

pages

587-96

issue

4

eissn

1520-9156

issn

1557-8593

journal_volume

7

pub_type

临床试验,杂志文章
  • Physiological and therapeutic roles of peroxisome proliferator-activated receptors.

    abstract::The peroxisome proliferator-activated receptors (PPARs) are a group of nuclear receptor isoforms, including PPARgamma, PPARalpha, and PPARdelta, encoded by different genes. PPARs are ligand-regulated transcription factors that control gene expression by binding to specific response elements (PPREs) within promoters. P...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/15209150260007381

    authors: Berger J,Wagner JA

    更新日期:2002-01-01 00:00:00

  • Factors associated with persistence and resumption of insulin pen use for patients with type 2 diabetes.

    abstract:OBJECTIVE:this study assessed patient-related factors associated with persistence and resumption of using pens as insulin delivery devices. METHODS:patients (n = 549; 300 current pen users, 249 former pen users) were recruited from national panels to participate in computer-assisted telephone interviews. Measures incl...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2010.0128

    authors: Peyrot M,Rubin RR

    更新日期:2011-01-01 00:00:00

  • Self-Monitoring of Blood Glucose (SMBG) in insulin- and non-insulin-using adults with diabetes: consensus recommendations for improving SMBG accuracy, utilization, and research.

    abstract::Current clinical guidelines for diabetes care encourage self-monitoring of blood glucose (SMBG) to improve glycemic control. Specific protocols remain variable, however, particularly among non-insulin-using patients. This is due in part to efficacy studies that neglect to consider (1) the performance of monitoring equ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2008.0104

    authors: Hirsch IB,Bode BW,Childs BP,Close KL,Fisher WA,Gavin JR,Ginsberg BH,Raine CH,Verderese CA

    更新日期:2008-12-01 00:00:00

  • Noninvasive continuous glucose monitoring using photoacoustic technology-results from the first 62 subjects.

    abstract:BACKGROUND:Continuous glucose monitoring is a useful tool for the achievement of improved glucose control in patients with diabetes. We tested the ability of a novel noninvasive continuous glucose monitor to track glucose excursions. METHODS:The novel noninvasive Aprise sensor (Glucon Inc., Boulder, CO) utilizes the p...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章

    doi:10.1089/dia.2006.0059

    authors: Weiss R,Yegorchikov Y,Shusterman A,Raz I

    更新日期:2007-02-01 00:00:00

  • Impact of glycemic control on heart rate variability in youth with type 1 diabetes: the SEARCH CVD study.

    abstract:AIM:This study explored the role of glycemic control on cardiac autonomic function, measured by heart rate variability (HRV), in youth with type 1 diabetes. PATIENTS AND METHODS:A retrospective cohort of 345 youth with type 1 diabetes (mean age, 18.5 years; duration, 10 years) participating in the SEARCH for Diabetes ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究

    doi:10.1089/dia.2013.0147

    authors: Jaiswal M,Fingerlin TE,Urbina EM,Wadwa RP,Talton JW,D'Agostino RB Jr,Hamman RF,Daniels SR,Marcovina SM,Dolan LM,Dabelea D

    更新日期:2013-12-01 00:00:00

  • A new imaging and data transmitting device for telemonitoring of diabetic foot syndrome patients.

    abstract:BACKGROUND:Proper healing of ulcers and wounds on the feet of diabetes patients is important in order to prevent amputation. If the wound area reduction during the first 4 weeks of the treatment is not 40% or more, reevaluation of the treatment is necessary. The wound area evaluation is not complicated when the patient...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2011.0004

    authors: Foltynski P,Ladyzynski P,Migalska-Musial K,Sabalinska S,Ciechanowska A,Wojcicki J

    更新日期:2011-08-01 00:00:00

  • Active assistance technology reduces glycosylated hemoglobin and weight in individuals with type 2 diabetes: results of a theory-based randomized trial.

    abstract:BACKGROUND:Type 2 diabetes is an individual health challenge requiring ongoing self-management. Remote patient reporting of relevant health parameters and linked automated feedback via mobile telephone have potential to strengthen self-management and improve outcomes. This research involved development and evaluation o...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2013.0056

    authors: Orsama AL,Lähteenmäki J,Harno K,Kulju M,Wintergerst E,Schachner H,Stenger P,Leppänen J,Kaijanranta H,Salaspuro V,Fisher WA

    更新日期:2013-08-01 00:00:00

  • Clinical Practice Recommendations on the Routine Use of Eversense, the First Long-Term Implantable Continuous Glucose Monitoring System.

    abstract:: Background: The use of real-time continuous glucose monitoring (rtCGM) systems has proved to positively impact the management of type 1 diabetes with the potential to lower HbA1c, reduce frequency and time spent in hypoglycemia, and lower glycemic variability. Nevertheless...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0397

    authors: Deiss D,Szadkowska A,Gordon D,Mallipedhi A,Schütz-Fuhrmann I,Aguilera E,Ringsell C,De Block C,Irace C

    更新日期:2019-05-01 00:00:00

  • A recent survey confirms the efficacy and the safety of implanted insulin pumps during long-term use in poorly controlled type 1 diabetes patients.

    abstract:BACKGROUND:This article reports a prolonged trial with insulin pumps implanted in patients with type 1 diabetes showing poor glucose control and a high rate of complications. METHODS:We reviewed data from 181 patients undergoing implanted insulin pump therapy. Analysis included hemoglobin A1c (HbA1c) values, body weig...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2010.0209

    authors: Schaepelynck P,Renard E,Jeandidier N,Hanaire H,Fermon C,Rudoni S,Catargi B,Riveline JP,Guerci B,Millot L,Martin JF,Sola A,EVADIAC Group.

    更新日期:2011-06-01 00:00:00

  • Role of continuous subcutaneous insulin infusion in patients with recalcitrant diabetes in South India.

    abstract:BACKGROUND:We aimed to assess the effect of continuous subcutaneous insulin infusion (CSII) therapy in patients with "recalcitrant diabetes" whose glycemia had not been controlled adequately with multiple daily injections of insulin or insulin plus oral hypoglycemic agents. PATIENTS AND METHODS:We retrospectively anal...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2009.0066

    authors: Sudhakaran C,Anjana RM,Rao K,Unnikrishnan R 1st,Suresh T,Mohan V

    更新日期:2009-11-01 00:00:00

  • Development of a Collaborative Algorithm for the Management of Type 2 Diabetes during Ramadan: An Anchor on Empowerment.

    abstract::Empowerment plays significant roles in the complex management of type 2 diabetes. International guidelines have provided recommendations on management of Muslims who fast during Ramadan. However, there remains a lack of patient-centered epistemic tool to empower healthcare providers and patients in managing diabetes d...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2018.0159

    authors: Lum ZK,See Toh WY,Lim SM,Rusli KDB,Abdul Shakoor SAKK,Tsou KYK,Chew DEK,Dalan R,Kwek SC,Othman N,Lian JX,Lee JY

    更新日期:2018-10-01 00:00:00

  • Lipoprotein-associated phospholipase A₂ activity predicts progression of subclinical coronary atherosclerosis.

    abstract:BACKGROUND:Lipoprotein-associated phospholipase A₂ (Lp-PLA₂) is a lipoprotein-associated enzyme that cleaves oxidized phosphatidylcholines, generating pro-atherosclerotic lysophosphatidylcholine and oxidized free fatty acids. Lp-PLA₂ is independently associated with cardiovascular disease (CVD) in a variety of populati...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2010.0175

    authors: Kinney GL,Snell-Bergeon JK,Maahs DM,Eckel RH,Ehrlich J,Rewers M,Hokanson JE

    更新日期:2011-03-01 00:00:00

  • Venous, Arterialized-Venous, or Capillary Glucose Reference Measurements for the Accuracy Assessment of a Continuous Glucose Monitoring System.

    abstract:BACKGROUND:Different reference methods are used for the accuracy assessment of continuous glucose monitoring (CGM) systems. The effect of using venous, arterialized-venous, or capillary reference measurements on CGM accuracy is unclear. METHODS:We evaluated 21 individuals with type 1 diabetes using a capillary calibra...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2017.0189

    authors: Kropff J,van Steen SC,deGraaff P,Chan MW,van Amstel RBE,DeVries JH

    更新日期:2017-11-01 00:00:00

  • Evaluating the accuracy, reliability, and clinical applicability of continuous glucose monitoring (CGM): Is CGM ready for real time?

    abstract:BACKGROUND:This study was designed to assess the accuracy, reliability, and contribution to clinical decision-making of two commercially available continuous glucose monitoring (CGM) devices using a novel analytical approach. STUDY DESIGN:Eleven individuals with type 1 diabetes and five with type 2 diabetes wore a Gua...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2008.0041

    authors: Mazze RS,Strock E,Borgman S,Wesley D,Stout P,Racchini J

    更新日期:2009-01-01 00:00:00

  • Differences in exhaled gas profiles between patients with type 2 diabetes and healthy controls.

    abstract:AIMS:Recent advances in analytical technology allow the detection of several hundred volatile organic compounds (VOCs) in human exhaled air, many of which reflect unidentified endogenous pathways. This study was performed to determine whether a breath gas analysis using proton transfer reaction-mass spectrometry (PTR-M...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2009.0181

    authors: Greiter MB,Keck L,Siegmund T,Hoeschen C,Oeh U,Paretzke HG

    更新日期:2010-06-01 00:00:00

  • Evaluation of a new blood glucose monitoring system with auto-calibration.

    abstract:BACKGROUND:The Ascensia CONTOUR System (Bayer HealthCare LLC, Elkhart, IN) is a new blood glucose (BG) monitoring system (BGMS) that uses glucose dehydrogenase chemistry and that combines low sample volume, fast response time, an auto-control marking feature, and an auto-calibration function in a small package. METHOD...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究

    doi:10.1089/dia.2005.7.283

    authors: Kilo C,Pinson M,Joynes JO,Joseph H,Monhaut N,Parkes JL,Baum J

    更新日期:2005-04-01 00:00:00

  • Personal glycation factors and calculated HbA1c for diabetes management: Real-world data from the DPV registry.

    abstract::Background Glycated hemoglobin A1c (HbA1c) is a key biomarker in the glycemic management of individuals with diabetes but the relationship with glucose levels can be variable. A recent kinetic model has described a calculated HbA1c (cHbA1c) that is individual-specific. Our aim was to validate the routine clinical use ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2020.0553

    authors: Xu Y,Grimsmann JM,Karges B,Hofer SE,Danne T,Holl RW,Ajjan RA,Dunn TD

    更新日期:2021-01-04 00:00:00

  • Can continuous subcutaneous insulin infusion improve health-related quality of life in patients with Shwachman-Bodian-Diamond syndrome and diabetes?

    abstract::We report the first case of the use of continuous subcutaneous insulin infusion (CSII) in a patient with Shwachman-Bodian-Diamond syndrome (SBDS) and diabetes. An Italian boy received diagnosis of SBDS at the age of 7 months (SBDS gene mutation: c.183-184TA → CT and c.258 + 2 T → C in compound heterozygous). The patie...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2014.0184

    authors: Terlizzi V,Zito E,Mozzillo E,Raia V,Franzese A

    更新日期:2015-01-01 00:00:00

  • Accuracy of glycemic measurements in the critically ill.

    abstract:BACKGROUND:Recent evidence emphasizes the importance of maintaining normoglycemia in critically ill patients to reduce morbidity and mortality. Different analytical methods of varying accuracy exist for obtaining and measuring blood glucose in critically ill patients. The purpose of this study was to determine if there...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2008.0263

    authors: Slater-MacLean L,Cembrowski G,Chin D,Shalapay C,Binette T,Hegadoren K,Newburn-Cook C

    更新日期:2008-06-01 00:00:00

  • Clinical predictors of glycosylated hemoglobin response to thiazolidinedione therapy.

    abstract:BACKGROUND:The aim of this investigation was to assess clinical predictors of the glycosylated hemoglobin (HbA1C) response after the addition of a thiazolidinedione (TZD) to a biguanide, a sulfonylurea, or both in subjects with type 2 diabetes. METHODS:Chart review (n = 68 physicians) was used to identify consecutive ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2007.0248

    authors: Izumi R,Hurt J,Maki KC,Bell M,Zavras AI,McCamish M

    更新日期:2007-12-01 00:00:00

  • Immobilized glucose oxidase in implantable glucose sensor technology.

    abstract::Glucose oxidase has had a central role in previous glucose sensing methods and is key to the development of certain new glucose sensors. The immobilized enzyme is specific for glucose and sufficiently long-lived for many sensor applications, but new glucose sensing applications may place increased demands on the enzym...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/15209150050194242

    authors: Gough DA,Bremer T

    更新日期:2000-10-01 00:00:00

  • Effectiveness of virtual reality using video gaming technology in elderly adults with diabetes mellitus.

    abstract:BACKGROUND:Diabetes in elderly adults is associated with an increased risk of fall. The aim of study was to determine whether a virtual reality exercise (VRE) program would improve balance, strength, gait, and falls efficacy in elderly adults with diabetes. SUBJECTS AND METHODS:Fifty-five subjects with diabetes mellit...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2013.0050

    authors: Lee S,Shin S

    更新日期:2013-06-01 00:00:00

  • Defining High Glycemic Variability in Type 1 Diabetes: Comparison of Multiple Indexes to Identify Patients at Risk of Hypoglycemia.

    abstract:: Background: International consensus on the use of continuous glucose monitoring (CGM) recommends coefficient of variation (CV) as the metric of choice to express glycemic variability (GV) with a cutoff of 36% to define unstable diabetes. Even though, CV is associated with ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2019.0075

    authors: Gómez AM,Henao DC,Imitola Madero A,Taboada LB,Cruz V,Robledo Gómez MA,Rondón M,Muñoz-Velandia O,García-Jaramillo M,León Vargas FM

    更新日期:2019-08-01 00:00:00

  • Measurement Performance of Two Continuous Tissue Glucose Monitoring Systems Intended for Replacement of Blood Glucose Monitoring.

    abstract:BACKGROUND:Currently, two systems for continuous tissue glucose monitoring (CGM) (Dexcom® G5 [DG5] and FreeStyle Libre [FL]) are intended to replace blood glucose monitoring (BGM) and, according to manufacturer labeling, are distributed as such in some jurisdictions, including the United States and the European Union. ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0105

    authors: Freckmann G,Link M,Pleus S,Westhoff A,Kamecke U,Haug C

    更新日期:2018-08-01 00:00:00

  • Intervention trials for prevention of metabolic syndrome and type 2 diabetes: focus on Asian Indians.

    abstract::Prevalence of diabetes continues to increase in urban areas, and escalation is discernible in semi-urban and rural areas. It is reported to affect Asian Indians a decade earlier compared with other populations, and complications (e.g., nephropathy) occur earlier and are severe and more prevalent than in other races. B...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2013.0373

    authors: Shrivastava U,Misra A

    更新日期:2014-08-01 00:00:00

  • Effect of vildagliptin on glucose and insulin concentrations during a 24-hour period in type 2 diabetes patients with different ranges of baseline hemoglobin A1c levels.

    abstract:BACKGROUND:Currently, it is still unknown whether differences in glycemic control have any effect on glucose and insulin kinetics after vildagliptin administration. The aim of this study was to evaluate the effect of vildagliptin on glucose and insulin concentrations during a 24-h period in type 2 diabetes patients wit...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2013.0020

    authors: González-Ortiz M,Sánchez-Peña MJ,González-Ortiz LJ,Robles-Cervantes JA,García-Ortega YE,Gómez-Gaitán EA,Pérez-Rubio KG,Martínez-Abundis E

    更新日期:2013-07-01 00:00:00

  • Feasibility Study of a Hybrid Closed-Loop System with Automated Insulin Correction Boluses.

    abstract:: Background: The Medtronic MiniMed™ 670G system adjusts basal insulin delivery in response to continuous glucose monitoring levels and is already in use in clinical practice. We tested the home-based feasibility of the new MiniMed advanced hybrid closed-loop (AHCL) system, ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2020.0448

    authors: Nimri R,Grosman B,Roy A,Nir J,Fisch Shvalb N,Kurtz N,Loewenthal N,Gillon-Keren M,Muller I,Atlas E,Phillip M

    更新日期:2020-12-08 00:00:00

  • Using multiple measures of glycemia to support individualized diabetes management: recommendations for clinicians, patients, and payers.

    abstract::By the year 2030, the diabetes pandemic will likely affect more than 10% of the world's population. The personal, public health, and economic crises implicit in this trend call for decisive action. Yet, escalating dilemmas thwart full realization of current therapies. First, controversial studies, such as the Action t...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2012.0132

    authors: Hirsch IB,Amiel SA,Blumer IR,Bode BW,Edelman SV,Seley JJ,Verderese CA,Kilpatrick ES

    更新日期:2012-11-01 00:00:00

  • Combining basal insulin analogs with glucagon-like peptide-1 mimetics.

    abstract::Basal insulin analogs are recognized as an effective method of achieving and maintaining glycemic control for patients with type 2 diabetes. However, the progressive nature of the disease means that some individuals may require additional ways to maintain their glycemic goals. Intensification in these circumstances ha...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2010.0250

    authors: Perfetti R

    更新日期:2011-09-01 00:00:00

  • Psychosocial correlates of continuous glucose monitoring use in youth and adults with type 1 diabetes and parents of youth.

    abstract:BACKGROUND:Continuous glucose monitoring (CGM) has been shown to improve glycemic control and reduce hypoglycemia with consistent use. Youth, however, are unlikely to use CGM consistently. We compared psychological characteristics of youth with type 1 diabetes, their parents, and adults with type 1 diabetes randomized ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2011.0201

    authors: Markowitz JT,Pratt K,Aggarwal J,Volkening LK,Laffel LM

    更新日期:2012-06-01 00:00:00