Abstract:
: Background: The financial strain of type 1 diabetes on the United States health care system, patients, and employers underscores the importance of developing novel treatments for the disease. This study estimated the lifetime economic burden attributable to type 1 diabetes in the United States. Methods: A patient-level, Markov state/transition simulation model was developed to compare cumulative societal costs among patients with and without type 1 diabetes. For each patient type, 1 prevalent and 10 incident cohorts were constructed and followed annually over a lifetime horizon. The 1 prevalent cohort with type 1 diabetes entered in the first year of the model and at the current age of each patient, whereas the 10 incident cohorts entered in each of 10 subsequent years and at the age of diagnosis of each patient. Patients were assigned age-specific annual medical expenditures and lost wages. Model outputs included the total cumulative medical and lost productivity costs attributable to type 1 diabetes, defined as the difference in costs between patients with and without type 1 diabetes. Results: The model consisted of 1,630,317 patients with type 1 diabetes and an equal number of patients without type 1 diabetes. The difference in lifetime costs was $813 billion (95% confidence interval: $682-$1037 billion), representing a high burden of illness compared with patients without type 1 diabetes. Sensitivity analyses demonstrated robustness in model results. Conclusions: Our findings suggest significant investment in research and development of novel treatments for type 1 diabetes is justified, given the high burden of illness associated with the disease.
journal_name
Diabetes Technol Therjournal_title
Diabetes technology & therapeuticsauthors
Sussman M,Benner J,Haller MJ,Rewers M,Griffiths Rdoi
10.1089/dia.2019.0398subject
Has Abstractpub_date
2020-02-01 00:00:00pages
121-130issue
2eissn
1520-9156issn
1557-8593journal_volume
22pub_type
杂志文章abstract:AIMS:This study compared glycemic control and maternal and fetal outcomes in pregnant women with type 1 diabetes mellitus (T1DM) treated with multiple daily injections (MDI) or continuous subcutaneous insulin infusion (CSII) using regular (RI) or lispro (LP) insulin. METHODS:Three hundred fifteen consecutive singleton...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2010.0111
更新日期:2010-12-01 00:00:00
abstract::Since the late 1970s, self-monitoring of blood glucose has been the standard for assessing daily glycemic control. The first continuous glucose monitor became available in 1999. Numerous clinical trials have documented the benefits of continuous glucose monitoring (CGM) in patients with type 1 diabetes mellitus (DM). ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2011.0086
更新日期:2012-02-01 00:00:00
abstract:BACKGROUND:We evaluated the impact of a 2-year chat line involving adolescents with type 1 diabetes regarding quality of life and metabolic control. METHODS:We enrolled 193 children, 10-18 years of age (mean ± SD, 13.6 ± 2.7 years), with type 1 diabetes for 1.2-6 years (3.6 ± 2.4 years), body mass index of 23.2 ± 4.1 ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2010.0188
更新日期:2011-05-01 00:00:00
abstract::On May 26, 1976, the Food and Drug Administration (FDA) began implementing the Medical Device Amendments to the Federal Food Drug and Cosmetic Act. These amendments give FDA specific authority to regulate "medical devices." Additional authority was provided in the Safe Medical Devices Act of 1990. The pathways to get ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/152091502321118784
更新日期:2002-01-01 00:00:00
abstract:AIMS:This study evaluated treatment satisfaction, comfort, and function using the wireless OmniPod™ Insulin Management System (Insulet Corp., Bedford, MA) compared with conventional (infusion set) insulin pumps in young adults with type 1 diabetes. RESEARCH DESIGN AND METHODS:Twenty-nine patients (age, 24.0 ± 5.1 year...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2011.0228
更新日期:2012-05-01 00:00:00
abstract:BACKGROUND:Long-term treatment is necessary to slow the progression of type 2 diabetes (T2D). Here, we examined the safety and efficacy of 6 years of treatment with exenatide once weekly (QW) among patients with T2D in the DURATION-1 trial. METHODS:The study enrolled patients aged ≥16 years with T2D treated primarily ...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章
doi:10.1089/dia.2016.0107
更新日期:2016-11-01 00:00:00
abstract:AIMS:Recent advances in analytical technology allow the detection of several hundred volatile organic compounds (VOCs) in human exhaled air, many of which reflect unidentified endogenous pathways. This study was performed to determine whether a breath gas analysis using proton transfer reaction-mass spectrometry (PTR-M...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2009.0181
更新日期:2010-06-01 00:00:00
abstract:BACKGROUND:This article reports a prolonged trial with insulin pumps implanted in patients with type 1 diabetes showing poor glucose control and a high rate of complications. METHODS:We reviewed data from 181 patients undergoing implanted insulin pump therapy. Analysis included hemoglobin A1c (HbA1c) values, body weig...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2010.0209
更新日期:2011-06-01 00:00:00
abstract:BACKGROUND:Continuous glucose monitoring is a useful tool for the achievement of improved glucose control in patients with diabetes. We tested the ability of a novel noninvasive continuous glucose monitor to track glucose excursions. METHODS:The novel noninvasive Aprise sensor (Glucon Inc., Boulder, CO) utilizes the p...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章
doi:10.1089/dia.2006.0059
更新日期:2007-02-01 00:00:00
abstract:BACKGROUND:Multicenter long-term studies of predictors for the effectiveness of continuous subcutaneous insulin infusion (CSII) in clinical practice are lacking. We hypothesized that there are substantially greater reductions in hemoglobin A1c (HbA1c) in patients with poor glycemic control and that other predictors may...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2014.0139
更新日期:2015-01-01 00:00:00
abstract:BACKGROUND:Insulin pumps (for continuous subcutaneous insulin infusion [CSII]) are used widely in type 1 diabetes mellitus. Although there has been considerable study of outcomes, there are few recent data on CSII-associated adverse events and no data on family perceptions of adverse events and their confidence in deal...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2013.0315
更新日期:2014-04-01 00:00:00
abstract:BACKGROUND:The masked continuous glucose monitoring system (Masked-CGMS) differs from standard CGMSs in three ways: (1) there is no feedback to the user so that no immediate regimen changes can be made; (2) it can only be worn for up to 5 days; and (3) there are no alarms to warn of hyperglycemia or hypoglycemia. Since...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2013.0297
更新日期:2014-05-01 00:00:00
abstract::Self-monitoring of blood glucose was described as one of the most important advancements in diabetes management since the invention of insulin in 1920. Recent advances in glucose sensor technology for measuring interstitial glucose concentrations have challenged the dominance of glucose meters in diabetes management, ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2009.0002
更新日期:2009-06-01 00:00:00
abstract:BACKGROUND:Different reference methods are used for the accuracy assessment of continuous glucose monitoring (CGM) systems. The effect of using venous, arterialized-venous, or capillary reference measurements on CGM accuracy is unclear. METHODS:We evaluated 21 individuals with type 1 diabetes using a capillary calibra...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2017.0189
更新日期:2017-11-01 00:00:00
abstract:BACKGROUND:Accurate and economic detection of nerve damage in diabetes is key to more widespread diagnosis of patients with diabetic peripheral neuropathy (DPN) and painful diabetic neuropathy. This study examined the diagnostic performance of NerveCheck, an inexpensive ($500) quantitative sensory testing (QST) device....
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2016.0279
更新日期:2016-12-01 00:00:00
abstract::Continuous glucose monitoring (CGM) is a new tool that has recently become available to people with diabetes. Properly designing and conducting trials in order to answer important questions regarding the clinical usefulness of CGM is very difficult and fraught with many confounding variables and unique challenges. Ini...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2009.0012
更新日期:2009-06-01 00:00:00
abstract:BACKGROUND:Implanted insulin pumps using the peritoneal route provide long-term improvement of glucose control compared with subcutaneous insulin therapy in type 1 diabetes (T1D) patients. The stability of insulin preparation is critical for a safe use in implanted pumps. Insuman implantable(®) (400 IU/mL) (Sanofi-Aven...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1089/dia.2013.0369
更新日期:2014-09-01 00:00:00
abstract:OBJECTIVE:Hemoglobin A1c (A1C) has recently been recommended for diagnosing diabetes mellitus and diabetes risk (prediabetes). Its performance compared with fasting plasma glucose (FPG) and 2-h post-glucose load (2HPG) is not well delineated. We compared the performance of A1C with that of FPG and 2HPG in preoperative ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2011.0074
更新日期:2011-12-01 00:00:00
abstract::The transplantation of microencapsulated islets may allow reversal of hyperglycemia in the absence of immunosuppression. Poly-L-lysine (PLL) on capsules may potentiate the fibrotic reaction against implanted capsules. The aims of this study were to investigate how the biocompatibility of such capsules affects their fu...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/152091503322250677
更新日期:2003-01-01 00:00:00
abstract:BACKGROUND:This exploratory study examined the pharmacokinetics and pharmacodynamics of a Bentley Pharmaceuticals, Inc. (North Hampton, NH) proprietary insulin formulation utilizing CPE-215 technology designed for intranasal administration. METHODS:Eight fasting healthy volunteers (four men, four women; body mass inde...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章
doi:10.1089/dia.2005.7.124
更新日期:2005-02-01 00:00:00
abstract:BACKGROUND:Obesity surgery elicits complex changes in glucose metabolism that are difficult to observe with discontinuous glucose measurements. We aimed to evaluate glucose variability after gastric bypass by continuous glucose monitoring (CGM) in a real-life setting. METHODS:CGM was performed for 4.2 ± 1.3 days in th...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2010.0203
更新日期:2011-06-01 00:00:00
abstract:: Background: Continuous subcutaneous insulin infusion (CSII) is associated with improved glycemic control, a reduced incidence of hypoglycemia, and improved quality of life (QOL). To date, however, there has been no QOL scale specific to CSII. The objective of this study wa...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2019.0216
更新日期:2020-03-01 00:00:00
abstract:BACKGROUND:The optimal treatment of diabetes in pregnancy requires accurate measurement of blood glucose levels, in order to minimize adverse outcomes for both mother and neonate. Self-monitoring of blood glucose is routinely used to measure glycemic control and to assess whether treatment targets are being met; howeve...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,收录出版
doi:10.1089/dia.2015.0104
更新日期:2016-02-01 00:00:00
abstract:BACKGROUND:The objective of this investigation was to evaluate the test-retest repeatability of insulin sensitivity and secretion indices derived from liquid meal tolerance tests (MTTs) in subjects with normal fasting glucose (NFG) (n = 20), impaired fasting glucose (IFG) (n = 20), or type 2 diabetes mellitus (n = 38)....
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2010.0083
更新日期:2010-11-01 00:00:00
abstract::Continuous glucose monitoring (CGM) systems have been available for more than 15 years by now. However, market uptake is relatively low in most countries; in other words, relatively few patients with diabetes use CGM systems regularly. One major reason for the reluctance of patients to use CGM systems is the costs ass...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2015.0296
更新日期:2016-02-01 00:00:00
abstract:BACKGROUND:Weight gain often occurs when insulin therapy is initiated. The long-acting insulin analog insulin detemir has been shown to be effective and well tolerated when used in basal-bolus regimens or as an add-on to oral antidiabetic drugs (OADs) and causes less weight gain than other insulins. The aim of this exp...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1089/dia.2008.0282
更新日期:2008-08-01 00:00:00
abstract::The Editor of Diabetes Technology & Therapeutics is officially retracting the article entitled, "No Deleterious Effect of Lockdown Due to COVID-19 Pandemic on Glycaemic Control, Measured by Glucose Monitoring, in Adults with Type 1 Diabetes," by Beato-Vibora PI. Diabetes Technol Ther 2020; epub DOI: 10.1089/dia.2020.0...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,收录出版
doi:10.1089/dia.2020.0184
更新日期:2020-05-12 00:00:00
abstract:BACKGROUND:Applying real-time learning into an artificial pancreas system could effectively track the unpredictable behavior of glucose-insulin dynamics and adjust insulin treatment accordingly. We describe a novel learning algorithm and its performance when integrated into the MD-Logic Artificial Pancreas (MDLAP) syst...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2010.0216
更新日期:2011-10-01 00:00:00
abstract:BACKGROUND:The present study evaluated the efficacy of biphasic human insulin 30 (BHI 30) in type 2 diabetes patients who had failed in therapy with two or more oral antidiabetes drugs (OADs). METHODS:This open-label, nonrandomized, 4-month, multicenter, clinical observational study was conducted in Shanghai, China. A...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究
doi:10.1089/dia.2011.0168
更新日期:2012-03-01 00:00:00
abstract::AIDA is a diabetes-computing program freely available from www.2aida.org on the Web. The software is intended to serve as an educational support tool, and can be used by anyone who has an interest in diabetes, whether they be patients, relatives, health-care professionals, or students. In previous "Diabetes Informatio...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/152091503763816490
更新日期:2003-01-01 00:00:00