Abstract:
:Self-monitoring of blood glucose was described as one of the most important advancements in diabetes management since the invention of insulin in 1920. Recent advances in glucose sensor technology for measuring interstitial glucose concentrations have challenged the dominance of glucose meters in diabetes management, while raising questions about the relationships between interstitial and blood glucose levels. This article will review the differences between interstitial and blood glucose and some of the challenges in measuring interstitial glucose levels accurately.
journal_name
Diabetes Technol Therjournal_title
Diabetes technology & therapeuticsauthors
Cengiz E,Tamborlane WVdoi
10.1089/dia.2009.0002subject
Has Abstractpub_date
2009-06-01 00:00:00pages
S11-6eissn
1520-9156issn
1557-8593journal_volume
11 Suppl 1pub_type
杂志文章,评审abstract:BACKGROUND:Continuous glucose monitoring (CGM) technologies report measurements of interstitial glucose concentration every 5 min. CGM technologies have the potential to be utilized for prediction of prospective glucose concentrations with subsequent optimization of glycemic control. This article outlines a feed-forwar...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2010.0104
更新日期:2011-02-01 00:00:00
abstract:BACKGROUND:Continuous glucose monitoring (CGM) has been shown to improve glycemic control and reduce hypoglycemia with consistent use. Youth, however, are unlikely to use CGM consistently. We compared psychological characteristics of youth with type 1 diabetes, their parents, and adults with type 1 diabetes randomized ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2011.0201
更新日期:2012-06-01 00:00:00
abstract:OBJECTIVE:Hemoglobin A1c (A1C) has recently been recommended for diagnosing diabetes mellitus and diabetes risk (prediabetes). Its performance compared with fasting plasma glucose (FPG) and 2-h post-glucose load (2HPG) is not well delineated. We compared the performance of A1C with that of FPG and 2HPG in preoperative ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2011.0074
更新日期:2011-12-01 00:00:00
abstract:BACKGROUND:This study explored the relationships between exogenous insulin requirements and endogenous variables in elderly patients with type 2 diabetes (T2D). SUBJECTS AND METHODS:Patients with T2D 65 years of age or older were enrolled for a short hospitalization period in order to start or change their basal-bolus...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2015.0044
更新日期:2016-05-01 00:00:00
abstract::Continuous glucose monitoring (CGM) systems have been available for more than 15 years by now. However, market uptake is relatively low in most countries; in other words, relatively few patients with diabetes use CGM systems regularly. One major reason for the reluctance of patients to use CGM systems is the costs ass...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2015.0296
更新日期:2016-02-01 00:00:00
abstract:BACKGROUND:The quantitative analysis of glucose time-series can greatly help the management of diabetes. In particular, a static nonlinear transformation, which symmetrizes the distribution of glucose levels by bringing them in the so-called risk space, was proposed previously for both self-monitoring blood glucose and...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2011.0006
更新日期:2011-08-01 00:00:00
abstract::Insulin infusion pump therapy has dramatically improved over the past 20 years and can now address some of the specific challenges related to toddlers with diabetes. We discuss both the non-randomized and randomized controlled trials comparing continuous subcutaneous insulin infusion (CSII) and multiple daily injectio...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2009.0182
更新日期:2010-06-01 00:00:00
abstract:: Background: The financial strain of type 1 diabetes on the United States health care system, patients, and employers underscores the importance of developing novel treatments for the disease. This study estimated the lifetime economic burden attributable to type 1 diabetes...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2019.0398
更新日期:2020-02-01 00:00:00
abstract:BACKGROUND:Computer decision support systems are potentially effective methods for adjusting insulin, but current models do not take into account simultaneous changes of more than one agent. We describe the development of the Multiagent Intelligent Dosing System (MAIDS, Dimensional Dosing Systems, Wexford, PA) for pred...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2005.7.937
更新日期:2005-12-01 00:00:00
abstract:BACKGROUND:Lipohypertrophy (LH) is a complication of insulin therapy. We assessed LH prevalence, risk factors, insulin usage, and clinical and health economic effects in China. METHODS:In four cities, 401 adult patients injecting insulin ≥1 year were surveyed for diabetes/insulin injection history and practices, pen n...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2016.0334
更新日期:2017-01-01 00:00:00
abstract:OBJECTIVE:We sought to cross validate several metrics for quality of glycemic control, hypoglycemia, and hyperglycemia. RESEARCH DESIGN AND METHODS:We analyzed the mathematical properties of several metrics for overall glycemic control, and for hypo- and hyperglycemia, to evaluate their similarities, differences, and ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2017.0416
更新日期:2018-05-01 00:00:00
abstract:BACKGROUND:Patients undergoing intensive insulin therapy may have blood glucose (BG) samples drawn from arterial, capillary, or venous sources. This study compared capillary and venous BG across a range of glucose concentrations and under conditions of rapid change in BG. METHODS:Following a 10-h fast, 40 adult patien...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章
doi:10.1089/dia.2009.0023
更新日期:2009-10-01 00:00:00
abstract:BACKGROUND:The management of hyperglycemia in the intensive care unit has been a controversial topic for more than a decade, with target ranges varying from 80-110 mg/dL to <200 mg/dL. Multiple insulin infusion protocols exist, including several computerized protocols, which have attempted to achieve these targets. Imp...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2016.0101
更新日期:2016-08-01 00:00:00
abstract:INTRODUCTION:The ProAct study has shown that a pump switch to the Accu-Chek(®) Combo system (Roche Diagnostics Deutschland GmbH, Mannheim, Germany) in type 1 diabetes patients results in stable glycemic control with significant improvements in glycated hemoglobin (HbA1c) in patients with unsatisfactory baseline HbA1c a...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章,多中心研究
doi:10.1089/dia.2014.0278
更新日期:2015-06-01 00:00:00
abstract::Chromium (Cr) picolinate (CrPic) is a widely used nutritional supplement for optimal insulin function. A relationship among Cr status, diabetes, and associated pathologies has been established. Virtually all trials using CrPic supplementation for subjects with diabetes have demonstrated beneficial effects. Thirteen of...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2006.8.677
更新日期:2006-12-01 00:00:00
abstract:BACKGROUND:Diabetic foot ulcer area is a basic parameter used for monitoring the wound healing and effectiveness of the treatment applied. TeleDiaFoS (developed earlier in collaboration with the Department and Clinic of Gastroenterology and Metabolic Diseases, Medical University of Warsaw, Warsaw, Poland) is one of jus...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2011.0082
更新日期:2011-11-01 00:00:00
abstract:BACKGROUND:Continuous glucose monitoring (CGM) provides glucose trend information that can be used to guide treatment and motivate patients with diabetes. Currently, the evidence on effectiveness of CGM in patients with type 2 diabetes is debatable. We aim to provide a systematic review and meta-analysis to synthesize ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,meta分析
doi:10.1089/dia.2018.0177
更新日期:2018-09-01 00:00:00
abstract:BACKGROUND:The present study evaluated the efficacy of biphasic human insulin 30 (BHI 30) in type 2 diabetes patients who had failed in therapy with two or more oral antidiabetes drugs (OADs). METHODS:This open-label, nonrandomized, 4-month, multicenter, clinical observational study was conducted in Shanghai, China. A...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究
doi:10.1089/dia.2011.0168
更新日期:2012-03-01 00:00:00
abstract:BACKGROUND:Performance of continuous glucose monitors (CGMs) may be lower when glucose levels are changing rapidly, such as occurs during physical activity. Our aim was to evaluate accuracy of a current-generation CGM during moderate-intensity exercise in type 1 diabetes (T1D) pregnancy. SUBJECTS AND METHODS:As part o...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2012.0292
更新日期:2013-03-01 00:00:00
abstract:BACKGROUND:A reliable method to detect biochemical nocturnal hypoglycemia is highly needed, especially in patients with recurrent severe hypoglycemia. We evaluated reliability of nocturnal continuous glucose monitoring (CGM) in patients with type 1 diabetes at high risk of severe hypoglycemia. PATIENTS AND METHODS:Sev...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1089/dia.2013.0004
更新日期:2013-05-01 00:00:00
abstract::Glucagon-like peptide 1 receptor agonists (GLP-1 RAs) are highly effective at lowering hemoglobin A1c (HbA1c) and facilitating weight loss. Four agents in the GLP-1 RA class, albiglutide, liraglutide, dulaglutide, and semaglutide, also have cardioprotective effects. However, subcutaneous administration of these agents...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2019.0185
更新日期:2020-01-01 00:00:00
abstract:BACKGROUND:Faster aspart is insulin aspart (IAsp) in a new formulation, which in continuous subcutaneous insulin infusion (CSII) in subjects with type 1 diabetes has shown a faster onset and offset of glucose-lowering effect than IAsp. METHODS:This double-blind, randomized, crossover active-controlled trial compared 2...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2016.0350
更新日期:2017-01-01 00:00:00
abstract:BACKGROUND:Insulin pumps (for continuous subcutaneous insulin infusion [CSII]) are used widely in type 1 diabetes mellitus. Although there has been considerable study of outcomes, there are few recent data on CSII-associated adverse events and no data on family perceptions of adverse events and their confidence in deal...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2013.0315
更新日期:2014-04-01 00:00:00
abstract:BACKGROUND:For patients with type 1 diabetes mellitus, a bihormonal artificial endocrine pancreas system utilizing glucagon and insulin has been found to stabilize glycemic control. However, commercially available formulations of glucagon cannot currently be used in such systems because of physical instability characte...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2014.0047
更新日期:2014-11-01 00:00:00
abstract:PURPOSE:This study investigated reasons for the rejection and discontinuation of insulin pump therapy and explored general attitudes towards this mode of therapy among young patients with type 1 diabetes. METHODS:A questionnaire was developed using a focus group of young people with diabetes. It was then used to surve...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2009.0080
更新日期:2010-01-01 00:00:00
abstract::The increasing prevalence of type 1 and type 2 diabetes mellitus combined with advancement in early detection of cardiovascular disease (CVD) has placed CVD as a significant concern for preventative pediatric medicine. The public health burden of type 2 diabetes is predicted to parallel increasing obesity in children ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2012.0018
更新日期:2012-06-01 00:00:00
abstract::Use of the Medtronic MiniMed Continuous Glucose Monitoring System (CGMS) in non-diabetic children has revealed many low and high sensor glucose (SG) values, suggesting that the original analytical algorithm (Solutions 2.0) might be overreading glycemic excursions. A revised algorithm (Solutions 3.0) was introduced in ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/152091503765691866
更新日期:2003-01-01 00:00:00
abstract::Disease registries are a searchable list of all patients with a particular chronic condition that often interface with an electronic medical record. The well-designed registry links all members of the patient's health team and provides key information for patients and physicians. The critical impact of a registry is t...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2008.0057
更新日期:2009-04-01 00:00:00
abstract:: Background: Continuous glucose monitoring (CGM) is a method of estimating blood glucose values from those recorded in the interstitial fluid. Because increasingly longer CGM measurements are possible, errors and data loss become more and more likely and potentially more da...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2018.0247
更新日期:2018-12-01 00:00:00
abstract:OBJECTIVE:To assess whether snacking could be used with closed-loop (CL) insulin delivery to avoid exercise-induced reductions in plasma glucose (PG), as well as elevations in PG at the end of exercise. RESEARCH DESIGN AND METHODS:Twelve type 1 diabetes (T1D) subjects (age 13-36 years, duration 10.7 ± 8.4 years, A1c 7...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2016.0311
更新日期:2016-12-01 00:00:00