Differences in exhaled gas profiles between patients with type 2 diabetes and healthy controls.

Abstract:

AIMS:Recent advances in analytical technology allow the detection of several hundred volatile organic compounds (VOCs) in human exhaled air, many of which reflect unidentified endogenous pathways. This study was performed to determine whether a breath gas analysis using proton transfer reaction-mass spectrometry (PTR-MS) could serve as a noninvasive method to distinguish between patients with type 2 diabetes mellitus and healthy controls. METHODS:Breath and room air samples were measured from 21 patients with insulin-treated type 2 diabetes and 26 healthy controls. VOCs in the mass range of 20-200 atomic mass units were analyzed using PTR-MS. RESULTS:We identified eight masses characteristic of endogenous VOCs that showed significant differences in the gas profiles of patients with type 2 diabetes and healthy control subjects. Using these VOCs for linear discriminant analysis, the sensitivity and specificity were found to be 90% and 92%, respectively. CONCLUSIONS:These results suggest that it is possible to separate patients with diabetes mellitus type 2 from healthy controls by multivariate analysis of exhaled endogenous VOCs. This is a first step towards the development of a noninvasive test using breath gas of at-risk persons and making it an attractive option for large-scale testing of at-risk populations. However, the establishment of exhaled volatiles as metabolic markers requires additional confirmatory investigations.

journal_name

Diabetes Technol Ther

authors

Greiter MB,Keck L,Siegmund T,Hoeschen C,Oeh U,Paretzke HG

doi

10.1089/dia.2009.0181

subject

Has Abstract

pub_date

2010-06-01 00:00:00

pages

455-63

issue

6

eissn

1520-9156

issn

1557-8593

journal_volume

12

pub_type

杂志文章
  • Cutaneous blood perfusion as a perturbing factor for noninvasive glucose monitoring.

    abstract::It is widely accepted that noninvasive glucose monitoring (NIGM) has the potential to revolutionize diabetes therapy. However, current approaches to NIGM studied to date have not yet demonstrated a level of acceptable functionality to allow real-time use, beyond restricted fields of application. A number of reviews ha...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2009.0095

    authors: Caduff A,Talary MS,Zakharov P

    更新日期:2010-01-01 00:00:00

  • Can continuous subcutaneous insulin infusion improve health-related quality of life in patients with Shwachman-Bodian-Diamond syndrome and diabetes?

    abstract::We report the first case of the use of continuous subcutaneous insulin infusion (CSII) in a patient with Shwachman-Bodian-Diamond syndrome (SBDS) and diabetes. An Italian boy received diagnosis of SBDS at the age of 7 months (SBDS gene mutation: c.183-184TA → CT and c.258 + 2 T → C in compound heterozygous). The patie...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2014.0184

    authors: Terlizzi V,Zito E,Mozzillo E,Raia V,Franzese A

    更新日期:2015-01-01 00:00:00

  • A recent survey confirms the efficacy and the safety of implanted insulin pumps during long-term use in poorly controlled type 1 diabetes patients.

    abstract:BACKGROUND:This article reports a prolonged trial with insulin pumps implanted in patients with type 1 diabetes showing poor glucose control and a high rate of complications. METHODS:We reviewed data from 181 patients undergoing implanted insulin pump therapy. Analysis included hemoglobin A1c (HbA1c) values, body weig...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2010.0209

    authors: Schaepelynck P,Renard E,Jeandidier N,Hanaire H,Fermon C,Rudoni S,Catargi B,Riveline JP,Guerci B,Millot L,Martin JF,Sola A,EVADIAC Group.

    更新日期:2011-06-01 00:00:00

  • Poor agreement of computerized calculators for mean amplitude of glycemic excursions.

    abstract:BACKGROUND:Glucose variability has been identified as a predictor of hypoglycemia and has been associated with mortality in critically ill patients without diabetes. A popular metric to quantify glucose variability is the mean amplitude of glycemic excursions (MAGE). The "ruler and pencil" approach to calculate MAGE is...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2013.0138

    authors: Sechterberger MK,Luijf YM,Devries JH

    更新日期:2014-02-01 00:00:00

  • Psychosocial correlates of continuous glucose monitoring use in youth and adults with type 1 diabetes and parents of youth.

    abstract:BACKGROUND:Continuous glucose monitoring (CGM) has been shown to improve glycemic control and reduce hypoglycemia with consistent use. Youth, however, are unlikely to use CGM consistently. We compared psychological characteristics of youth with type 1 diabetes, their parents, and adults with type 1 diabetes randomized ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2011.0201

    authors: Markowitz JT,Pratt K,Aggarwal J,Volkening LK,Laffel LM

    更新日期:2012-06-01 00:00:00

  • Alternative delivery of insulin via eye drops.

    abstract:BACKGROUND:Various insulin delivery systems have been considered for systemic absorption other than injections. Although the ocular route has been suggested, its use is limited by the amount of insulin absorbed systemically via eyes. In order to improve the absorption rate of insulin into systemic circulations, the eff...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2005.7.695

    authors: Xuan B,McClellan DA,Moore R,Chiou GC

    更新日期:2005-10-01 00:00:00

  • Effectiveness of virtual reality using video gaming technology in elderly adults with diabetes mellitus.

    abstract:BACKGROUND:Diabetes in elderly adults is associated with an increased risk of fall. The aim of study was to determine whether a virtual reality exercise (VRE) program would improve balance, strength, gait, and falls efficacy in elderly adults with diabetes. SUBJECTS AND METHODS:Fifty-five subjects with diabetes mellit...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2013.0050

    authors: Lee S,Shin S

    更新日期:2013-06-01 00:00:00

  • High Glucose Variability in Hospitalized Patients with Type 1 Diabetes Mellitus.

    abstract:BACKGROUND:Glucose variability (GV) has been increasingly (or more extensively) studied in patients with type 1 diabetes (T1D) in the ambulatory setting; limited data exist on GV in hospitalized patients with T1D. MATERIALS AND METHODS:Retrospective single center cohort study, we analyzed in-hospital glucose measureme...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2017.0107

    authors: Dadlani V,Tamhane SU,Sun A,Sharma A,Delivanis DA,Thapa P,Carter RE,Kudva YC

    更新日期:2017-10-01 00:00:00

  • Defining High Glycemic Variability in Type 1 Diabetes: Comparison of Multiple Indexes to Identify Patients at Risk of Hypoglycemia.

    abstract:: Background: International consensus on the use of continuous glucose monitoring (CGM) recommends coefficient of variation (CV) as the metric of choice to express glycemic variability (GV) with a cutoff of 36% to define unstable diabetes. Even though, CV is associated with ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2019.0075

    authors: Gómez AM,Henao DC,Imitola Madero A,Taboada LB,Cruz V,Robledo Gómez MA,Rondón M,Muñoz-Velandia O,García-Jaramillo M,León Vargas FM

    更新日期:2019-08-01 00:00:00

  • System Accuracy Evaluation of Different Blood Glucose Monitoring Systems Following ISO 15197:2013 by Using Two Different Comparison Methods.

    abstract:BACKGROUND:Adherence to established standards (e.g., International Organization for Standardization [ISO] 15197) is important to ensure comparable and sufficient accuracy of systems for self-monitoring of blood glucose (SMBG). Accuracy evaluation was performed for different SMBG systems available in Europe with three r...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2015.0085

    authors: Freckmann G,Link M,Schmid C,Pleus S,Baumstark A,Haug C

    更新日期:2015-09-01 00:00:00

  • Reimbursement for Continuous Glucose Monitoring.

    abstract::Continuous glucose monitoring (CGM) systems have been available for more than 15 years by now. However, market uptake is relatively low in most countries; in other words, relatively few patients with diabetes use CGM systems regularly. One major reason for the reluctance of patients to use CGM systems is the costs ass...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2015.0296

    authors: Heinemann L,DeVries JH

    更新日期:2016-02-01 00:00:00

  • A dynamic risk measure from continuous glucose monitoring data.

    abstract:BACKGROUND:The quantitative analysis of glucose time-series can greatly help the management of diabetes. In particular, a static nonlinear transformation, which symmetrizes the distribution of glucose levels by bringing them in the so-called risk space, was proposed previously for both self-monitoring blood glucose and...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2011.0006

    authors: Guerra S,Sparacino G,Facchinetti A,Schiavon M,Man CD,Cobelli C

    更新日期:2011-08-01 00:00:00

  • Noninvasive continuous glucose monitoring using photoacoustic technology-results from the first 62 subjects.

    abstract:BACKGROUND:Continuous glucose monitoring is a useful tool for the achievement of improved glucose control in patients with diabetes. We tested the ability of a novel noninvasive continuous glucose monitor to track glucose excursions. METHODS:The novel noninvasive Aprise sensor (Glucon Inc., Boulder, CO) utilizes the p...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章

    doi:10.1089/dia.2006.0059

    authors: Weiss R,Yegorchikov Y,Shusterman A,Raz I

    更新日期:2007-02-01 00:00:00

  • The Impact of Short-Term Professional Continuous Glucose Monitoring on Glycemic Control Via Lifestyle Improvement.

    abstract:BACKGROUND:The efficacy of short-term professional continuous glucose monitoring (CGM) for glycemic control in patients with diabetes remains unclear. METHODS:We performed a 3-month study to evaluate the benefits of CGM in 64 patients. RESULTS:The overall glycemic control of patients who underwent CGM improved signif...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0164

    authors: Shibusawa R,Yamada E,Okada S,Nakajima Y,Bastie CC,Yamada M

    更新日期:2018-09-01 00:00:00

  • Analysis of continuous glucose monitoring data from non-diabetic and diabetic children: a tale of two algorithms.

    abstract::Use of the Medtronic MiniMed Continuous Glucose Monitoring System (CGMS) in non-diabetic children has revealed many low and high sensor glucose (SG) values, suggesting that the original analytical algorithm (Solutions 2.0) might be overreading glycemic excursions. A revised algorithm (Solutions 3.0) was introduced in ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/152091503765691866

    authors: Weinzimer SA,DeLucia MC,Boland EA,Steffen A,Tamborlane WV

    更新日期:2003-01-01 00:00:00

  • Metrics to Evaluate Quality of Glycemic Control: Comparison of Time in Target, Hypoglycemic, and Hyperglycemic Ranges with "Risk Indices".

    abstract:OBJECTIVE:We sought to cross validate several metrics for quality of glycemic control, hypoglycemia, and hyperglycemia. RESEARCH DESIGN AND METHODS:We analyzed the mathematical properties of several metrics for overall glycemic control, and for hypo- and hyperglycemia, to evaluate their similarities, differences, and ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2017.0416

    authors: Rodbard D

    更新日期:2018-05-01 00:00:00

  • The association of self-monitoring of blood glucose use with medication adherence and glycemic control in patients with type 2 diabetes initiating non-insulin treatment.

    abstract:BACKGROUND:The value of self-monitoring of blood glucose (SMBG) for persons with type 2 diabetes who do not use insulin remains controversial. This observational study compares the likelihood of medication adherence and change in glycated hemoglobin (A1C) for non-insulin-using patients using SMBG versus those not using...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2012.0047

    authors: Virdi N,Daskiran M,Nigam S,Kozma C,Raja P

    更新日期:2012-09-01 00:00:00

  • Accuracy and reliability of continuous glucose monitoring systems: a head-to-head comparison.

    abstract:OBJECTIVE:This study assessed the accuracy and reliability of three continuous glucose monitoring (CGM) systems. RESEARCH DESIGN AND METHODS:We studied the Animas® (West Chester, PA) Vibe™ with Dexcom® (San Diego, CA) G4™ version A sensor (G4A), the Abbott Diabetes Care (Alameda, CA) Freestyle® Navigator I (NAV), and ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1089/dia.2013.0049

    authors: Luijf YM,Mader JK,Doll W,Pieber T,Farret A,Place J,Renard E,Bruttomesso D,Filippi A,Avogaro A,Arnolds S,Benesch C,Heinemann L,DeVries JH,AP@home consortium.

    更新日期:2013-08-01 00:00:00

  • Prevalence of Diabetic Neuropathy in Young Adults with Type 1 Diabetes and the Association with Insulin Pump Therapy.

    abstract:AIMS:The aim was to investigate the prevalence of diabetic sensorimotor polyneuropathy (DSPN) and cardiovascular autonomic neuropathy (CAN) in a Danish population of young adults with type 1 diabetes (T1D) using both established and novel measuring modalities. Furthermore, to investigate the association between continu...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0249

    authors: Christensen MMB,Hommel EE,Jørgensen ME,von Scholten BJ,Fleischer J,Hansen CS

    更新日期:2018-11-21 00:00:00

  • Mitigating Reductions in Glucose During Exercise on Closed-Loop Insulin Delivery: The Ex-Snacks Study.

    abstract:OBJECTIVE:To assess whether snacking could be used with closed-loop (CL) insulin delivery to avoid exercise-induced reductions in plasma glucose (PG), as well as elevations in PG at the end of exercise. RESEARCH DESIGN AND METHODS:Twelve type 1 diabetes (T1D) subjects (age 13-36 years, duration 10.7 ± 8.4 years, A1c 7...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2016.0311

    authors: Patel NS,Van Name MA,Cengiz E,Carria LR,Tichy EM,Weyman K,Weinzimer SA,Tamborlane WV,Sherr JL

    更新日期:2016-12-01 00:00:00

  • Virtual Coaching to Enhance Diabetes Care.

    abstract::Rates of diabetes are increasing worldwide and there is not a sufficient clinical workforce to care for these patients. Diabetes-related apps are a feasible way to provide diabetes education to large numbers of people with diabetes but attrition rates are high. Apps enhanced by virtual coaching may be a way to circumn...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2019.0016

    authors: Ramchandani N

    更新日期:2019-06-01 00:00:00

  • Glycemic Variability Is Associated with Frequency of Blood Glucose Testing and Bolus: Post Hoc Analysis Results from the ProAct Study.

    abstract:INTRODUCTION:The ProAct study has shown that a pump switch to the Accu-Chek(®) Combo system (Roche Diagnostics Deutschland GmbH, Mannheim, Germany) in type 1 diabetes patients results in stable glycemic control with significant improvements in glycated hemoglobin (HbA1c) in patients with unsatisfactory baseline HbA1c a...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1089/dia.2014.0278

    authors: Pfützner A,Weissmann J,Mougiakakou S,Daskalaki E,Weis N,Ziegler R

    更新日期:2015-06-01 00:00:00

  • Feasibility of continuous subcutaneous insulin infusion and daily supplemental insulin glargine injection in children with type 1 diabetes.

    abstract:BACKGROUND:Continuous subcutaneous insulin infusion (CSII) is an effective method of insulin substitution with increased risk of hypoglycemia and diabetic ketoacidosis (DKA) in rare situations. The lack of subcutaneous long-acting insulin and short half-life of serum insulin increases the risk of ketosis and DKA follow...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2008.0124

    authors: Alemzadeh R,Parton EA,Holzum MK

    更新日期:2009-08-01 00:00:00

  • Automatic learning algorithm for the MD-logic artificial pancreas system.

    abstract:BACKGROUND:Applying real-time learning into an artificial pancreas system could effectively track the unpredictable behavior of glucose-insulin dynamics and adjust insulin treatment accordingly. We describe a novel learning algorithm and its performance when integrated into the MD-Logic Artificial Pancreas (MDLAP) syst...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2010.0216

    authors: Miller S,Nimri R,Atlas E,Grunberg EA,Phillip M

    更新日期:2011-10-01 00:00:00

  • A Feasibility Study of Paired Continuous Glucose Monitoring Intrapartum and in the Newborn in Pregnancies Complicated by Type 1 Diabetes.

    abstract:AIM:To describe the continuous glucose monitoring (CGM) profiles of type 1 diabetes (T1D) offspring in the early neonatal period and its association with maternal intrapartum glucose control. METHODS:A prospective observational study of T1D pregnant women and their neonatal offspring. Women had a CGM sensor inserted 2...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0221

    authors: Stewart ZA,Thomson L,Murphy HR,Beardsall K

    更新日期:2019-01-01 00:00:00

  • Inaccurate Glucose Sensor Values After Hydroxyurea Administration.

    abstract:: Objective: To assess the degree, duration, mean absolute relative difference (MARD), and error analysis of discrepant values per continuous glucose monitoring (CGM) systems after hydroxyurea (HU) administration. Research Design and Methods: ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2020.0490

    authors: Tellez SE,Hornung LN,Courter JD,Abu-El-Haija M,Nathan JD,Lawson SA,Elder DA

    更新日期:2020-12-30 00:00:00

  • Wear and biomechanical characteristics of a novel shear-reducing insole with implications for high-risk persons with diabetes.

    abstract:OBJECTIVE:This study was designed to measure pressure and shear reduction of a novel insole design. METHODS:We compared three multilayer viscoelastic insoles to a novel insole design (Glide-Soft, Xilas Medical, Inc., San Antonio, TX). The bottom pad of each insole was fabricated from firm-density Plastazote [Apex Foot...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2005.7.638

    authors: Lavery LA,Lanctot DR,Constantinides G,Zamorano RG,Athanasiou KA,Agrawal CM

    更新日期:2005-08-01 00:00:00

  • Minimization of Hypoglycemia as an Adverse Event During Insulin Infusion: Further Refinement of the Yale Protocol.

    abstract:BACKGROUND:The management of hyperglycemia in the intensive care unit has been a controversial topic for more than a decade, with target ranges varying from 80-110 mg/dL to <200 mg/dL. Multiple insulin infusion protocols exist, including several computerized protocols, which have attempted to achieve these targets. Imp...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2016.0101

    authors: Marvin MR,Inzucchi SE,Besterman BJ

    更新日期:2016-08-01 00:00:00

  • Association of DRD3, COMT, and SLC6A4 Gene Polymorphisms with Type 2 Diabetes in Southern Chinese: A Hospital-Based Case-Control Study.

    abstract:AIM:The aim of this study was to assess the associations of six single nucleotide polymorphisms (SNPs) of three genes (DRD3, COMT, and SCL6A4) with type 2 diabetes mellitus (T2DM) in Southern Chinese. SUBJECTS AND METHODS:Five hundred ninety-five cases with T2DM and 725 healthy controls of Han origin were recruited fr...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2014.0344

    authors: Xiu L,Lin M,Liu W,Kong D,Liu Z,Zhang Y,Ouyang P,Liang Y,Zhong S,Chen C,Jin X,Fan X,Qin J,Zhao X,Rao S,Ding Y

    更新日期:2015-08-01 00:00:00

  • Enzymatic fluorescent microsphere glucose sensors:evaluation of response under dynamic conditions.

    abstract::Most previous attempts at the development of a "smart tattoo" for glucose monitoring in diabetes--implantable fluorescent microspheres that can be implanted intradermally and interrogated transdermally using light--have focused on the encapsulation of a competitive binding assay for glucose within hydrogel microsphere...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2006.8.288

    authors: Brown JQ,Srivastava R,Zhu H,McShane MJ

    更新日期:2006-06-01 00:00:00