Chat line for adolescents with type 1 diabetes: a useful tool to improve coping with diabetes: a 2-year follow-up study.

Abstract:

BACKGROUND:We evaluated the impact of a 2-year chat line involving adolescents with type 1 diabetes regarding quality of life and metabolic control. METHODS:We enrolled 193 children, 10-18 years of age (mean ± SD, 13.6 ± 2.7 years), with type 1 diabetes for 1.2-6 years (3.6 ± 2.4 years), body mass index of 23.2 ± 4.1 kg/m(2), insulin requirement of 0.7 ± 0.3 U/kg/day, and glycated hemoglobin (HbA1c) of 7.8 ± 1.1%, who participated in a weekly physician-moderated chat line for a 2-year follow-up period. Each patient completed the Diabetes Quality of Life for Youth Inventory (DQOLY) at baseline and after 1 and 2 years. A measure of glycemic control (HbA1c) was also collected. Data from 17 patients who discontinued using the chat line were not included in the analysis. As controls, 203 patients with type 1 diabetes, age- and sex-matched, with similar HbA1c at baseline and socioeconomic status, were randomly selected among 834 patients who refused to participate in the chat sessions. RESULTS:DQOLY responses from youth with type 1 diabetes showed a significant improvement (P = 0.0001) only in patients who participated in chat sessions. We observed a decrease of 0.4% in HbA1c in patients who participated in chat session (7.8 ± 1.1% vs. 7.4 ± 0.5%, P < 0.0001) compared with the 0.1% of the controls (7.9 ± 1.9% vs. 7.8 ± 1.8%, P = 0.668). No difference was observed in HbA1c between the two groups (P = 0.056). CONCLUSIONS:A chat line is also a cheap and effective tool that helps improve diabetes compliance. The chat line could help the diabetes team understand and treat their patients more comprehensively; moreover, it could help patients cope better with their daily life.

journal_name

Diabetes Technol Ther

authors

Iafusco D,Galderisi A,Nocerino I,Cocca A,Zuccotti G,Prisco F,Scaramuzza A

doi

10.1089/dia.2010.0188

subject

Has Abstract

pub_date

2011-05-01 00:00:00

pages

551-5

issue

5

eissn

1520-9156

issn

1557-8593

journal_volume

13

pub_type

杂志文章
  • Feasibility of a portable bihormonal closed-loop system to control glucose excursions at home under free-living conditions for 48 hours.

    abstract:BACKGROUND:This study assessed the feasibility of a portable bihormonal closed-loop system at home. SUBJECTS AND METHODS:Sixteen pump-treated patients with type 1 diabetes received 48 h of closed-loop therapy with a telemonitored insulin- and glucagon-delivering closed-loop system and 48 h of patient-managed open-loop...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2013.0166

    authors: van Bon AC,Luijf YM,Koebrugge R,Koops R,Hoekstra JB,DeVries JH

    更新日期:2014-03-01 00:00:00

  • Reduction in hemoglobin A1C with real-time continuous glucose monitoring: results from a 12-week observational study.

    abstract:BACKGROUND:Real-time continuous glucose monitoring (CGM) was studied in 140 adults with diabetes over a 12-week period of home use. Hemoglobin A(1c)(HbA1c) was measured on day 1 (baseline) and at weeks 6 and 12. METHODS:On day 1, participants received the CGM device (STS(R) System, DexCom, Inc., San Diego, CA) and und...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1089/dia.2007.0205

    authors: Bailey TS,Zisser HC,Garg SK

    更新日期:2007-06-01 00:00:00

  • Efficacy and Safety of Biosimilar SAR342434 Insulin Lispro in Adults with Type 1 Diabetes Also Using Insulin Glargine-SORELLA 1 Study.

    abstract:BACKGROUND:SAR342434 is a biosimilar follow-on of insulin lispro-Humalog®. This study aimed to show similar efficacy, safety, and immunogenicity of SAR342434 (SAR-Lis) versus insulin lispro-Humalog (Ly-Lis) in adult patients with type 1 diabetes (T1DM) treated with multiple daily injections while using basal insulin gl...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1089/dia.2017.0117

    authors: Garg SK,Wernicke-Panten K,Rojeski M,Pierre S,Kirchhein Y,Jedynasty K

    更新日期:2017-09-01 00:00:00

  • Preserving Skin Integrity with Chronic Device Use in Diabetes.

    abstract::Skin integrity and diabetes device placement are ongoing concerns for people with diabetes who utilize continuous glucose monitors (CGMs) and continuous subcutaneous insulin infusion pumps. This is especially significant for individuals with skin sensitivities, pediatric patients, and those who use devices chronically...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0080

    authors: Messer LH,Berget C,Beatson C,Polsky S,Forlenza GP

    更新日期:2018-06-01 00:00:00

  • Continuous glucose monitoring health outcomes.

    abstract::Continuous glucose monitoring (CGM) is a new tool that has recently become available to people with diabetes. Properly designing and conducting trials in order to answer important questions regarding the clinical usefulness of CGM is very difficult and fraught with many confounding variables and unique challenges. Ini...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2009.0012

    authors: Edelman SV,Bailey TS

    更新日期:2009-06-01 00:00:00

  • Continuous Glucose Monitoring, Glycemic Variability, and Excessive Fetal Growth in Pregnancies Complicated by Type 1 Diabetes.

    abstract:BACKGROUND:To examine trimester-specific associations among glycemic variability, fetal growth, and birthweight in pregnancies with type 1 diabetes mellitus (Type 1 DM). METHODS:In this retrospective cohort study of 41 pregnant women with Type 1 DM, we used continuous glucose monitoring (CGM) data to calculate glycemi...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2017.0443

    authors: Mulla BM,Noor N,James-Todd T,Isganaitis E,Takoudes TC,Curran A,Warren CE,O'Brien KE,Brown FM

    更新日期:2018-06-01 00:00:00

  • Predicting the effectiveness of insulin pump therapy on glycemic control in clinical practice: a retrospective study of patients with type 1 diabetes from 10 outpatient diabetes clinics in Sweden over 5 years.

    abstract:BACKGROUND:Multicenter long-term studies of predictors for the effectiveness of continuous subcutaneous insulin infusion (CSII) in clinical practice are lacking. We hypothesized that there are substantially greater reductions in hemoglobin A1c (HbA1c) in patients with poor glycemic control and that other predictors may...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2014.0139

    authors: Clements M,Matuleviciene V,Attvall S,Ekelund M,Pivodic A,Dahlqvist S,Fahlén M,Haraldsson B,Lind M

    更新日期:2015-01-01 00:00:00

  • Evaluation of Blood Glucose Meter Efficacy in an Antenatal Diabetes Clinic.

    abstract:BACKGROUND:The optimal treatment of diabetes in pregnancy requires accurate measurement of blood glucose levels, in order to minimize adverse outcomes for both mother and neonate. Self-monitoring of blood glucose is routinely used to measure glycemic control and to assess whether treatment targets are being met; howeve...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,收录出版

    doi:10.1089/dia.2015.0104

    authors: McGrath RT,Donnelly VC,Glastras SJ,Preda VA,Sheriff N,Ward P,Hocking SL,Fulcher GR

    更新日期:2016-02-01 00:00:00

  • Patient perceptions of using the OmniPod system compared with conventional insulin pumps in young adults with type 1 diabetes.

    abstract:AIMS:This study evaluated treatment satisfaction, comfort, and function using the wireless OmniPod™ Insulin Management System (Insulet Corp., Bedford, MA) compared with conventional (infusion set) insulin pumps in young adults with type 1 diabetes. RESEARCH DESIGN AND METHODS:Twenty-nine patients (age, 24.0 ± 5.1 year...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2011.0228

    authors: Lebenthal Y,Lazar L,Benzaquen H,Shalitin S,Phillip M

    更新日期:2012-05-01 00:00:00

  • A Feasibility Study of Paired Continuous Glucose Monitoring Intrapartum and in the Newborn in Pregnancies Complicated by Type 1 Diabetes.

    abstract:AIM:To describe the continuous glucose monitoring (CGM) profiles of type 1 diabetes (T1D) offspring in the early neonatal period and its association with maternal intrapartum glucose control. METHODS:A prospective observational study of T1D pregnant women and their neonatal offspring. Women had a CGM sensor inserted 2...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0221

    authors: Stewart ZA,Thomson L,Murphy HR,Beardsall K

    更新日期:2019-01-01 00:00:00

  • Development and Validation of the Continuous Subcutaneous Insulin Infusion-Related Quality-of-Life (CSII-QOL) Scale.

    abstract:: Background: Continuous subcutaneous insulin infusion (CSII) is associated with improved glycemic control, a reduced incidence of hypoglycemia, and improved quality of life (QOL). To date, however, there has been no QOL scale specific to CSII. The objective of this study wa...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2019.0216

    authors: Sakane N,Murata T,Tone A,Kato K,Kimura M,Kawashima S,Sawaki H,Hirota Y,Okada A,Kuroda A,Matsuhisa M,Watanabe T,Suganuma A,Nirengi S,Toyoda M

    更新日期:2020-03-01 00:00:00

  • Home blood glucose prediction: validation, safety, and efficacy testing in clinical diabetes.

    abstract:BACKGROUND:Patients with diabetes do daily self-monitoring of blood glucose (SMBG). For such patients, we devised an engine that predicts not only the expected blood glucose level at the next meal but also the pending risks of hypoglycemia. The purpose of this study was to validate the predictions and provide evidence ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2005.7.487

    authors: Albisser AM,Sakkal S,Wright C

    更新日期:2005-06-01 00:00:00

  • Continuous glucose monitoring in patients undergoing cardiac surgery.

    abstract:OBJECTIVES:Hyperglycemia is a prominent feature among patients exposed to major stress such as in cardiac surgery. The implementation of a continuous glucose monitoring system (CGMS) for glucose monitoring during cardiac surgery was assessed. SUBJECTS AND METHODS:Fifty-nine consecutive patients who underwent cardiac s...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2011.0154

    authors: Kalmovich B,Bar-Dayan Y,Boaz M,Wainstein J

    更新日期:2012-03-01 00:00:00

  • Active assistance technology reduces glycosylated hemoglobin and weight in individuals with type 2 diabetes: results of a theory-based randomized trial.

    abstract:BACKGROUND:Type 2 diabetes is an individual health challenge requiring ongoing self-management. Remote patient reporting of relevant health parameters and linked automated feedback via mobile telephone have potential to strengthen self-management and improve outcomes. This research involved development and evaluation o...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2013.0056

    authors: Orsama AL,Lähteenmäki J,Harno K,Kulju M,Wintergerst E,Schachner H,Stenger P,Leppänen J,Kaijanranta H,Salaspuro V,Fisher WA

    更新日期:2013-08-01 00:00:00

  • Basal plus basal-bolus approach in type 2 diabetes.

    abstract::Type 2 diabetes is characterized by insulin resistance and progressive β-cell deterioration. As β-cell function declines, most patients with type 2 diabetes treated with oral agents, in monotherapy or combination, will require insulin therapy. Addition of basal insulin (glargine, detemir, or NPH/neutral protamine lisp...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2011.0001

    authors: Ampudia-Blasco FJ,Rossetti P,Ascaso JF

    更新日期:2011-06-01 00:00:00

  • Can continuous subcutaneous insulin infusion improve health-related quality of life in patients with Shwachman-Bodian-Diamond syndrome and diabetes?

    abstract::We report the first case of the use of continuous subcutaneous insulin infusion (CSII) in a patient with Shwachman-Bodian-Diamond syndrome (SBDS) and diabetes. An Italian boy received diagnosis of SBDS at the age of 7 months (SBDS gene mutation: c.183-184TA → CT and c.258 + 2 T → C in compound heterozygous). The patie...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2014.0184

    authors: Terlizzi V,Zito E,Mozzillo E,Raia V,Franzese A

    更新日期:2015-01-01 00:00:00

  • Incidence and Predictors of Dysglycemia and Regression to Normoglycemia in Indian Adolescents and Young Adults: 10-Year Follow-Up of the ORANGE Study.

    abstract:: Background: The prevalence of diabetes in youth is increasing worldwide in parallel with the obesity epidemic. This study aimed to determine the incidence rates of dysglycemia (diabetes or prediabetes) and evaluate the predictors of its progression or regression to normal ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2020.0109

    authors: Mehreen TS,Kamalesh R,Pandiyan D,Kumar DS,Anjana RM,Mohan V,Ranjani H

    更新日期:2020-12-01 00:00:00

  • Human factors research applied: the development of a personal touch screen insulin pump and users' perceptions of actual use.

    abstract:BACKGROUND:A brief history of the field of human factors research is covered, along with how this discipline is leveraged within medical device companies, to eliminate design flaws in products, in order to make them safe and effective for human use. The way in which human factors research was used to develop the t:slim...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究

    doi:10.1089/dia.2013.0098

    authors: Schaeffer NE

    更新日期:2013-10-01 00:00:00

  • Evaluation of a Nurse-Managed Insulin Infusion Protocol.

    abstract:BACKGROUND:The purpose of this study was to evaluate the performance of an insulin infusion protocol targeting a blood glucose (BG) level of 140-180 mg/dL and to characterize protocol adherence. MATERIALS AND METHODS:This was a retrospective observational cohort study including patients for whom the protocol was order...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2015.0046

    authors: Passarelli AJ,Gibbs H,Rowden AM,Efird L,Zink E,Mathioudakis N

    更新日期:2016-02-01 00:00:00

  • A new imaging and data transmitting device for telemonitoring of diabetic foot syndrome patients.

    abstract:BACKGROUND:Proper healing of ulcers and wounds on the feet of diabetes patients is important in order to prevent amputation. If the wound area reduction during the first 4 weeks of the treatment is not 40% or more, reevaluation of the treatment is necessary. The wound area evaluation is not complicated when the patient...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2011.0004

    authors: Foltynski P,Ladyzynski P,Migalska-Musial K,Sabalinska S,Ciechanowska A,Wojcicki J

    更新日期:2011-08-01 00:00:00

  • The influence of environmental temperature on the response of the skin to local pressure: the impact of aging and diabetes.

    abstract:BACKGROUND:To protect against ischemia, pressure-induced vasodilation (PIV) causes an increase in skin blood flow. Endothelial dysfunction, which is commonly found in older patients and those with diabetes, and global temperatures can affect the resting blood flow in skin, which may reduce the blood flow during and aft...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2009.0097

    authors: McLellan K,Petrofsky JS,Zimmerman G,Lohman E,Prowse M,Schwab E,Lee S

    更新日期:2009-12-01 00:00:00

  • Continuous glucose monitoring pilot in low-income type 1 diabetes patients.

    abstract:BACKGROUND:Continuous glucose monitoring (CGM) has been shown to be a valuable tool to improve glycemic control in patients with diabetes. The objective of this pilot study was to develop and implement CGM in an existing diabetes clinic for low-income patients on multiple daily injections. SUBJECTS AND METHODS:This wa...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2013.0072

    authors: Sequeira PA,Montoya L,Ruelas V,Xing D,Chen V,Beck R,Peters AL

    更新日期:2013-10-01 00:00:00

  • A tale of two compartments: interstitial versus blood glucose monitoring.

    abstract::Self-monitoring of blood glucose was described as one of the most important advancements in diabetes management since the invention of insulin in 1920. Recent advances in glucose sensor technology for measuring interstitial glucose concentrations have challenged the dominance of glucose meters in diabetes management, ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2009.0002

    authors: Cengiz E,Tamborlane WV

    更新日期:2009-06-01 00:00:00

  • Validation of physical activity monitors in individuals with diabetes: energy expenditure estimation by the multisensor SenseWear Armband Pro3 and the step counter Omron HJ-720 against indirect calorimetry during walking.

    abstract:BACKGROUND:The purpose of this study is to test the agreement between energy expenditure estimate of the SenseWear(®) Armband Pro3 (SWA) (BodyMedia, Pittsburgh, PA) and the Omron HJ-720 (Omron Healthcare, Kyoto, Japan) step counter with indirect calorimetry (IC) as a gold standard in older individuals with type 1 and t...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2012.0235

    authors: Machač S,Procházka M,Radvanský J,Slabý K

    更新日期:2013-05-01 00:00:00

  • Reviewing U.S. Connected Diabetes Care: The Newest Member of the Team.

    abstract::Recent years have brought about an explosion in the number of companies offering connected diabetes care products, defined as digital diabetes management systems based around (1) smartphone apps, (2) devices with built-in connectivity, and (3) remote human and automated coaching and support. These nascent models aim t...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2019.0273

    authors: Levine BJ,Close KL,Gabbay RA

    更新日期:2020-01-01 00:00:00

  • Role of Continuous Glucose Monitoring in Clinical Trials: Recommendations on Reporting.

    abstract::Thanks to significant improvements in the precision, accuracy, and usability of continuous glucose monitoring (CGM), its relevance in both ambulatory diabetes care and clinical research is increasing. In this study, we address the latter perspective and derive provisional reporting recommendations. CGM systems have be...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2017.0054

    authors: Schnell O,Barnard K,Bergenstal R,Bosi E,Garg S,Guerci B,Haak T,Hirsch IB,Ji L,Joshi SR,Kamp M,Laffel L,Mathieu C,Polonsky WH,Snoek F,Home P

    更新日期:2017-07-01 00:00:00

  • Benchmark data from the literature for evaluation of new glucose sensing technologies.

    abstract::New glucose sensors based on various technologies are being developed to provide information for improved therapy in diabetes. There is a need to establish rational performance standards for these sensors. Frequently sampled, direct blood glucose recordings representative of blood glucose excursions in diabetes are th...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/15209150152607196

    authors: Bremer TM,Edelman SV,Gough DA

    更新日期:2001-10-01 00:00:00

  • Attitudes towards insulin pump therapy among adolescents and young people.

    abstract:PURPOSE:This study investigated reasons for the rejection and discontinuation of insulin pump therapy and explored general attitudes towards this mode of therapy among young patients with type 1 diabetes. METHODS:A questionnaire was developed using a focus group of young people with diabetes. It was then used to surve...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2009.0080

    authors: Seereiner S,Neeser K,Weber C,Schreiber K,Habacher W,Rakovac I,Beck P,Schmidt L,Pieber TR

    更新日期:2010-01-01 00:00:00

  • Combining basal insulin analogs with glucagon-like peptide-1 mimetics.

    abstract::Basal insulin analogs are recognized as an effective method of achieving and maintaining glycemic control for patients with type 2 diabetes. However, the progressive nature of the disease means that some individuals may require additional ways to maintain their glycemic goals. Intensification in these circumstances ha...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2010.0250

    authors: Perfetti R

    更新日期:2011-09-01 00:00:00

  • Efficacy and Tolerability of Exenatide Once Weekly Over 6 Years in Patients with Type 2 Diabetes: An Uncontrolled Open-Label Extension of the DURATION-1 Study.

    abstract:BACKGROUND:Long-term treatment is necessary to slow the progression of type 2 diabetes (T2D). Here, we examined the safety and efficacy of 6 years of treatment with exenatide once weekly (QW) among patients with T2D in the DURATION-1 trial. METHODS:The study enrolled patients aged ≥16 years with T2D treated primarily ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章

    doi:10.1089/dia.2016.0107

    authors: Henry RR,Klein EJ,Han J,Iqbal N