Basal plus basal-bolus approach in type 2 diabetes.

Abstract:

:Type 2 diabetes is characterized by insulin resistance and progressive β-cell deterioration. As β-cell function declines, most patients with type 2 diabetes treated with oral agents, in monotherapy or combination, will require insulin therapy. Addition of basal insulin (glargine, detemir, or NPH/neutral protamine lispro insulin) to previous treatment is accepted as the simplest way to start insulin therapy in those patients. But even when basal insulin is adequately titrated, some patients will also need prandial insulin to achieve or maintain individual glycemic targets over time. Starting with premixed insulin is an effective option, but it is frequently associated with increased hypoglycemia risk, fixed meal schedules, and weight gain. As an alternative, a novel approached known as "basal plus strategy" has been developed. This approach considers the addition of increasing injections of prandial insulin, beginning with the meal that has the major impact on postprandial glucose values. Finally, if this is not enough intensification to basal-bolus will be necessary. In reducing hyperglycemia, this modality still remains the most effective option, even in people with type 2 diabetes. This article will review the currently evidence on the basal plus strategy and also its progression to basal-bolus therapy. In addition, practical recommendations to start and adjust basal plus therapy will be provided.

journal_name

Diabetes Technol Ther

authors

Ampudia-Blasco FJ,Rossetti P,Ascaso JF

doi

10.1089/dia.2011.0001

subject

Has Abstract

pub_date

2011-06-01 00:00:00

pages

S75-83

eissn

1520-9156

issn

1557-8593

journal_volume

13 Suppl 1

pub_type

杂志文章,评审
  • Non-invasive glucose measurement technologies: an update from 1999 to the dawn of the new millennium.

    abstract::There are three main issues in non-invasive (NI) glucose measurements: namely, specificity, compartmentalization of glucose values, and calibration. There has been progress in the use of near-infrared and mid-infrared spectroscopy. Recently new glucose measurement methods have been developed, exploiting the effect of ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2004.6.660

    authors: Khalil OS

    更新日期:2004-10-01 00:00:00

  • Time is glucose, can't miss gestational diabetes.

    abstract:BACKGROUND:Gestational diabetes mellitus (GDM) is associated with adverse perinatal outcomes, if not treated. International guidelines recommend screening "all or high-risk women" at the initial prenatal visit, when a fasting plasma glucose (FPG) between 92 and 126 mg/dL is diagnostic for GDM. However, glucose testing ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2011.0225

    authors: Festa R,Carta M,Ceriello A,Testa R

    更新日期:2012-05-01 00:00:00

  • Efficacy and Safety of Biosimilar SAR342434 Insulin Lispro in Adults with Type 1 Diabetes Also Using Insulin Glargine-SORELLA 1 Study.

    abstract:BACKGROUND:SAR342434 is a biosimilar follow-on of insulin lispro-Humalog®. This study aimed to show similar efficacy, safety, and immunogenicity of SAR342434 (SAR-Lis) versus insulin lispro-Humalog (Ly-Lis) in adult patients with type 1 diabetes (T1DM) treated with multiple daily injections while using basal insulin gl...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1089/dia.2017.0117

    authors: Garg SK,Wernicke-Panten K,Rojeski M,Pierre S,Kirchhein Y,Jedynasty K

    更新日期:2017-09-01 00:00:00

  • Area of the diabetic ulcers estimated applying a foot scanner-based home telecare system and three reference methods.

    abstract:BACKGROUND:Diabetic foot ulcer area is a basic parameter used for monitoring the wound healing and effectiveness of the treatment applied. TeleDiaFoS (developed earlier in collaboration with the Department and Clinic of Gastroenterology and Metabolic Diseases, Medical University of Warsaw, Warsaw, Poland) is one of jus...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2011.0082

    authors: Ladyzynski P,Foltynski P,Molik M,Tarwacka J,Migalska-Musial K,Mlynarczuk M,Wojcicki JM,Krzymien J,Karnafel W

    更新日期:2011-11-01 00:00:00

  • The impact of initiating biphasic human insulin 30 therapy in type 2 diabetes patients after failure of oral antidiabetes drugs.

    abstract:BACKGROUND:The present study evaluated the efficacy of biphasic human insulin 30 (BHI 30) in type 2 diabetes patients who had failed in therapy with two or more oral antidiabetes drugs (OADs). METHODS:This open-label, nonrandomized, 4-month, multicenter, clinical observational study was conducted in Shanghai, China. A...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究

    doi:10.1089/dia.2011.0168

    authors: Gu Y,Hou X,Zhang L,Pan J,Cai Q,Bao Y,Jia W

    更新日期:2012-03-01 00:00:00

  • High glycemic variability assessed by continuous glucose monitoring after surgical treatment of obesity by gastric bypass.

    abstract:BACKGROUND:Obesity surgery elicits complex changes in glucose metabolism that are difficult to observe with discontinuous glucose measurements. We aimed to evaluate glucose variability after gastric bypass by continuous glucose monitoring (CGM) in a real-life setting. METHODS:CGM was performed for 4.2 ± 1.3 days in th...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2010.0203

    authors: Hanaire H,Bertrand M,Guerci B,Anduze Y,Guillaume E,Ritz P

    更新日期:2011-06-01 00:00:00

  • Reference values of skin autofluorescence.

    abstract:BACKGROUND:Skin autofluorescence (AF) as measured with the AGE Reader (DiagnOptics Technologies, Groningen, The Netherlands) is a noninvasive prognostic marker in diabetes mellitus and other diseases with increased cardiovascular risk. This study provides reference values of healthy Caucasian control subjects as a func...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2009.0113

    authors: Koetsier M,Lutgers HL,de Jonge C,Links TP,Smit AJ,Graaff R

    更新日期:2010-05-01 00:00:00

  • Determining clinical and psychological benefits and barriers with continuous glucose monitoring therapy.

    abstract:BACKGROUND:Preventing the complications of diabetes requires tight control and minimizing blood glucose fluctuation. Pursuing these goals increases the risk of severe hypoglycemia. The authors hoped to identify if using continuous glucose monitoring (CGM) decreased the incidence of severe hypoglycemia, resulted in less...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2009.0121

    authors: Halford J,Harris C

    更新日期:2010-03-01 00:00:00

  • Accuracy of continuous glucose monitoring during exercise in type 1 diabetes pregnancy.

    abstract:BACKGROUND:Performance of continuous glucose monitors (CGMs) may be lower when glucose levels are changing rapidly, such as occurs during physical activity. Our aim was to evaluate accuracy of a current-generation CGM during moderate-intensity exercise in type 1 diabetes (T1D) pregnancy. SUBJECTS AND METHODS:As part o...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2012.0292

    authors: Kumareswaran K,Elleri D,Allen JM,Caldwell K,Nodale M,Wilinska ME,Amiel SA,Hovorka R,Murphy HR

    更新日期:2013-03-01 00:00:00

  • Role of continuous subcutaneous insulin infusion in patients with recalcitrant diabetes in South India.

    abstract:BACKGROUND:We aimed to assess the effect of continuous subcutaneous insulin infusion (CSII) therapy in patients with "recalcitrant diabetes" whose glycemia had not been controlled adequately with multiple daily injections of insulin or insulin plus oral hypoglycemic agents. PATIENTS AND METHODS:We retrospectively anal...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2009.0066

    authors: Sudhakaran C,Anjana RM,Rao K,Unnikrishnan R 1st,Suresh T,Mohan V

    更新日期:2009-11-01 00:00:00

  • Fluorescein kinetics in interstitial fluid harvested from diabetic skin during fluorescein angiography: implications for glucose monitoring.

    abstract:BACKGROUND:Glucose monitoring based on sampling skin interstitial fluid (ISF) is being developed as an alternative to fingerstick blood glucose monitoring. Time delays between rapidly changing levels of glucose in blood and interstitial fluid have been reported in the literature to be between 5 and 20 minutes. This stu...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/152091599317530

    authors: Smith A,Yang D,Delcher H,Eppstein J,Williams D,Wilkes S

    更新日期:1999-04-01 00:00:00

  • Can continuous subcutaneous insulin infusion improve health-related quality of life in patients with Shwachman-Bodian-Diamond syndrome and diabetes?

    abstract::We report the first case of the use of continuous subcutaneous insulin infusion (CSII) in a patient with Shwachman-Bodian-Diamond syndrome (SBDS) and diabetes. An Italian boy received diagnosis of SBDS at the age of 7 months (SBDS gene mutation: c.183-184TA → CT and c.258 + 2 T → C in compound heterozygous). The patie...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2014.0184

    authors: Terlizzi V,Zito E,Mozzillo E,Raia V,Franzese A

    更新日期:2015-01-01 00:00:00

  • Validation of the SoloSTAR insulin pen.

    abstract:BACKGROUND:This study was designed to validate the use of SoloSTAR (sanofi-aventis Deutschland GmbH, Frankfurt, Germany), a new disposable pen developed for use with insulin glargine by patients with type 1 or type 2 diabetes. METHODS:This single-center, open-label, single-arm, sequential trial enrolled subjects with ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章

    doi:10.1089/dia.2008.0079

    authors: Schwartz S,Vlajnic A

    更新日期:2008-10-01 00:00:00

  • A new imaging and data transmitting device for telemonitoring of diabetic foot syndrome patients.

    abstract:BACKGROUND:Proper healing of ulcers and wounds on the feet of diabetes patients is important in order to prevent amputation. If the wound area reduction during the first 4 weeks of the treatment is not 40% or more, reevaluation of the treatment is necessary. The wound area evaluation is not complicated when the patient...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2011.0004

    authors: Foltynski P,Ladyzynski P,Migalska-Musial K,Sabalinska S,Ciechanowska A,Wojcicki J

    更新日期:2011-08-01 00:00:00

  • Variability of insulin absorption and insulin action.

    abstract::Subcutaneous (s.c.) injections of identical insulin doses may lead to considerable intra- and inter-individual differences in the current metabolic control of patients with diabetes mellitus. This well-known variability of the metabolic effect of insulin hampers practical insulin therapy considerably. The aim of this ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/152091502320798312

    authors: Heinemann L

    更新日期:2002-01-01 00:00:00

  • Estimated Lifetime Economic Burden of Type 1 Diabetes.

    abstract:: Background: The financial strain of type 1 diabetes on the United States health care system, patients, and employers underscores the importance of developing novel treatments for the disease. This study estimated the lifetime economic burden attributable to type 1 diabetes...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2019.0398

    authors: Sussman M,Benner J,Haller MJ,Rewers M,Griffiths R

    更新日期:2020-02-01 00:00:00

  • Venous, Arterialized-Venous, or Capillary Glucose Reference Measurements for the Accuracy Assessment of a Continuous Glucose Monitoring System.

    abstract:BACKGROUND:Different reference methods are used for the accuracy assessment of continuous glucose monitoring (CGM) systems. The effect of using venous, arterialized-venous, or capillary reference measurements on CGM accuracy is unclear. METHODS:We evaluated 21 individuals with type 1 diabetes using a capillary calibra...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2017.0189

    authors: Kropff J,van Steen SC,deGraaff P,Chan MW,van Amstel RBE,DeVries JH

    更新日期:2017-11-01 00:00:00

  • Safety and Performance of the Omnipod Hybrid Closed-Loop System in Adults, Adolescents, and Children with Type 1 Diabetes Over 5 Days Under Free-Living Conditions.

    abstract:: Background: The objective of this study was to assess the safety and performance of the Omnipod® personalized model predictive control (MPC) algorithm in adults, adolescents, and children aged ≥6 years with type 1 diabetes (T1D) under free-living conditions using an invest...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1089/dia.2019.0286

    authors: Sherr JL,Buckingham BA,Forlenza GP,Galderisi A,Ekhlaspour L,Wadwa RP,Carria L,Hsu L,Berget C,Peyser TA,Lee JB,O'Connor J,Dumais B,Huyett LM,Layne JE,Ly TT

    更新日期:2020-03-01 00:00:00

  • Waist circumference identifies primary school children with metabolic syndrome abnormalities.

    abstract:OBJECTIVE:This study was designed to assess whether waist circumference can predict metabolic syndrome abnormalities in primary schoolchildren. RESEARCH DESIGN AND METHODS:Of 5,103 children (2,526 males) 4-13 years old who underwent anthropometric measurements, 530 had more extensive testing. Body mass index (BMI), wa...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究

    doi:10.1089/dia.2006.0017

    authors: Hirschler V,Maccallini G,Calcagno M,Aranda C,Jadzinsky M

    更新日期:2007-04-01 00:00:00

  • The Impact of Short-Term Professional Continuous Glucose Monitoring on Glycemic Control Via Lifestyle Improvement.

    abstract:BACKGROUND:The efficacy of short-term professional continuous glucose monitoring (CGM) for glycemic control in patients with diabetes remains unclear. METHODS:We performed a 3-month study to evaluate the benefits of CGM in 64 patients. RESULTS:The overall glycemic control of patients who underwent CGM improved signif...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0164

    authors: Shibusawa R,Yamada E,Okada S,Nakajima Y,Bastie CC,Yamada M

    更新日期:2018-09-01 00:00:00

  • "Glucometrics"--assessing the quality of inpatient glucose management.

    abstract:BACKGROUND:For patients with diabetes, the quality of outpatient glycemic control is readily assessed by hemoglobin A1c. In contrast, standardized measures for assessing the quality of blood glucose (BG) management in hospitalized patients are lacking. Because of recent studies demonstrating the benefits of strict glyc...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2006.8.560

    authors: Goldberg PA,Bozzo JE,Thomas PG,Mesmer MM,Sakharova OV,Radford MJ,Inzucchi SE

    更新日期:2006-10-01 00:00:00

  • Use of an insulin bolus advisor facilitates earlier and more frequent changes in insulin therapy parameters in suboptimally controlled patients with diabetes treated with multiple daily insulin injection therapy: results of the ABACUS trial.

    abstract:BACKGROUND:We assessed the impact of using an automated bolus advisor integrated into a blood glucose meter on the timing and frequency of adjusting insulin therapy parameter settings and whether the availability of this technology would increase blood glucose test strip utilization in diabetes patients treated with mu...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1089/dia.2013.0280

    authors: Cavan DA,Ziegler R,Cranston I,Barnard K,Ryder J,Vogel C,Parkin CG,Koehler W,Vesper I,Petersen B,Schweitzer MA,Wagner RS

    更新日期:2014-05-01 00:00:00

  • Continuous glucose monitoring by means of the microdialysis technique: underlying fundamental aspects.

    abstract::The microdialysis technique allows extraction of substances (e.g., glucose) from fluids in the human body for quantitative measurements ex vivo. The microdialysis catheter can be inserted in many different tissues; for continuous glucose monitoring it is most often implanted in the subcutaneous fat tissue in the abdom...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/152091503322250578

    authors: Heinemann L,Glucose Monitoring Study Group.

    更新日期:2003-01-01 00:00:00

  • The Effectiveness of Continuous Glucose Monitoring in Patients with Type 2 Diabetes: A Systematic Review of Literature and Meta-analysis.

    abstract:BACKGROUND:Continuous glucose monitoring (CGM) provides glucose trend information that can be used to guide treatment and motivate patients with diabetes. Currently, the evidence on effectiveness of CGM in patients with type 2 diabetes is debatable. We aim to provide a systematic review and meta-analysis to synthesize ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,meta分析

    doi:10.1089/dia.2018.0177

    authors: Park C,Le QA

    更新日期:2018-09-01 00:00:00

  • Feasibility Study of a Hybrid Closed-Loop System with Automated Insulin Correction Boluses.

    abstract:: Background: The Medtronic MiniMed™ 670G system adjusts basal insulin delivery in response to continuous glucose monitoring levels and is already in use in clinical practice. We tested the home-based feasibility of the new MiniMed advanced hybrid closed-loop (AHCL) system, ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2020.0448

    authors: Nimri R,Grosman B,Roy A,Nir J,Fisch Shvalb N,Kurtz N,Loewenthal N,Gillon-Keren M,Muller I,Atlas E,Phillip M

    更新日期:2020-12-08 00:00:00

  • Patients' perceptions of subcutaneous insulin in the OPTIMIZE study: a multicenter follow-up study.

    abstract:BACKGROUND:The Optimizing Control in Diabetes (OPTIMIZE) survey was conducted to understand the patients' perspective to achieving good glycemic control and to determine how patients' perceptions of insulin may affect their decisions to initiate or intensify their insulin therapy. METHODS:A total of 1,444 subjects wit...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究

    doi:10.1089/dia.2008.0249

    authors: Cefalu WT,Mathieu C,Davidson J,Freemantle N,Gough S,Canovatchel W,OPTIMIZE Coalition.

    更新日期:2008-02-01 00:00:00

  • Intervention trials for prevention of metabolic syndrome and type 2 diabetes: focus on Asian Indians.

    abstract::Prevalence of diabetes continues to increase in urban areas, and escalation is discernible in semi-urban and rural areas. It is reported to affect Asian Indians a decade earlier compared with other populations, and complications (e.g., nephropathy) occur earlier and are severe and more prevalent than in other races. B...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2013.0373

    authors: Shrivastava U,Misra A

    更新日期:2014-08-01 00:00:00

  • Perioperative Characteristics of the Accuracy of Subcutaneous Continuous Glucose Monitoring: Pilot Study in Neurosurgery and Cardiac Surgery.

    abstract:BACKGROUND:The aim of this study was to elucidate the characteristics of accuracy of subcutaneous continuous glucose monitoring (SCGM) in the perioperative period for neurosurgical and cardiac surgery patients. METHODS:Forty-five subjects, including healthy volunteers (n = 15), neurosurgical patients (n = 15), and car...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0140

    authors: Sugiyama Y,Wakabayashi R,Urasawa M,Maruyama Y,Shimizu S,Kawamata M

    更新日期:2018-10-01 00:00:00

  • Mitigating Reductions in Glucose During Exercise on Closed-Loop Insulin Delivery: The Ex-Snacks Study.

    abstract:OBJECTIVE:To assess whether snacking could be used with closed-loop (CL) insulin delivery to avoid exercise-induced reductions in plasma glucose (PG), as well as elevations in PG at the end of exercise. RESEARCH DESIGN AND METHODS:Twelve type 1 diabetes (T1D) subjects (age 13-36 years, duration 10.7 ± 8.4 years, A1c 7...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2016.0311

    authors: Patel NS,Van Name MA,Cengiz E,Carria LR,Tichy EM,Weyman K,Weinzimer SA,Tamborlane WV,Sherr JL

    更新日期:2016-12-01 00:00:00

  • Adiponectin and carotid intimal medial thickness in subjects with and without glucose intolerance (CURES-82).

    abstract:OBJECTIVE:This study assessed the association of serum adiponectin with carotid intimal medial thickness (IMT) in Asian Indians with different grades of glucose intolerance. METHODS:Subjects with normal glucose tolerance (NGT) (n = 520), impaired glucose tolerance (IGT) (n = 115), and type 2 diabetes mellitus (T2DM) (...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2009.0100

    authors: Gokulakrishnan K,Indulekha K,Ganesan S,Anuradha S,Mohan V

    更新日期:2010-02-01 00:00:00