Abstract:
BACKGROUND:Proper healing of ulcers and wounds on the feet of diabetes patients is important in order to prevent amputation. If the wound area reduction during the first 4 weeks of the treatment is not 40% or more, reevaluation of the treatment is necessary. The wound area evaluation is not complicated when the patient stays at a hospital, but when he or she goes home the physician does not have a tool allowing monitoring of the wound area. METHODS AND RESULTS:The aim of the present article is to present a new device able to take a wound picture and send it automatically to the database. This device, called the Patient's Module (PM), is also able to download data from the memories of blood pressure and blood glucose meters and send the data to the database. The PM is able to operate within the TeleDiaFoS system (developed earlier in collaboration with the Department and Clinic of Gastroenterology and Metabolic Diseases, Medical University of Warsaw, Warsaw, Poland) aimed at monitoring of treatment of patients with diabetic foot syndrome. The PM was tested on 10 type 2 diabetes patients during a 3-month period. CONCLUSIONS:The study revealed that the PM can be used as a home telemonitoring device, and the analysis of the data sent from patient's home enables the assessment of wound healing progress, giving the physician the possibility for earlier change of the treatment if the wound area reduction is not satisfactory.
journal_name
Diabetes Technol Therjournal_title
Diabetes technology & therapeuticsauthors
Foltynski P,Ladyzynski P,Migalska-Musial K,Sabalinska S,Ciechanowska A,Wojcicki Jdoi
10.1089/dia.2011.0004subject
Has Abstractpub_date
2011-08-01 00:00:00pages
861-7issue
8eissn
1520-9156issn
1557-8593journal_volume
13pub_type
杂志文章abstract:: Background: Current manual diabetic retinopathy (DR) screening using eye care experts cannot scale to screen the growing population of diabetes patients who are at risk for vision loss. EyeArt system is an automated, cloud-based artificial intelligence (AI) eye screening t...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2019.0164
更新日期:2019-11-01 00:00:00
abstract:BACKGROUND:Diabetes mellitus is rare in young infants and neonates. Continuous subcutaneous insulin infusion (CSII) is used most frequently for insulin treatment in this age group. However, the individual doctor's experience is scarce because of the low prevalence of diabetes in this age. For this study patients treate...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究
doi:10.1089/dia.2015.0030
更新日期:2015-12-01 00:00:00
abstract:BACKGROUND:Obstructive sleep apnea (OSA), a highly prevalent condition, is independently associated with increased risks of developing type 2 diabetes mellitus (T2D) and metabolic syndrome. It is unclear, however, if the severity of OSA has any impact on glycemic control among patients with T2D. We therefore aimed to d...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2011.0005
更新日期:2011-09-01 00:00:00
abstract:OBJECTIVE:this study assessed patient-related factors associated with persistence and resumption of using pens as insulin delivery devices. METHODS:patients (n = 549; 300 current pen users, 249 former pen users) were recruited from national panels to participate in computer-assisted telephone interviews. Measures incl...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2010.0128
更新日期:2011-01-01 00:00:00
abstract:BACKGROUND:Obesity surgery elicits complex changes in glucose metabolism that are difficult to observe with discontinuous glucose measurements. We aimed to evaluate glucose variability after gastric bypass by continuous glucose monitoring (CGM) in a real-life setting. METHODS:CGM was performed for 4.2 ± 1.3 days in th...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2010.0203
更新日期:2011-06-01 00:00:00
abstract::Thanks to significant improvements in the precision, accuracy, and usability of continuous glucose monitoring (CGM), its relevance in both ambulatory diabetes care and clinical research is increasing. In this study, we address the latter perspective and derive provisional reporting recommendations. CGM systems have be...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2017.0054
更新日期:2017-07-01 00:00:00
abstract:BACKGROUND:Skin autofluorescence (AF) as measured with the AGE Reader (DiagnOptics Technologies, Groningen, The Netherlands) is a noninvasive prognostic marker in diabetes mellitus and other diseases with increased cardiovascular risk. This study provides reference values of healthy Caucasian control subjects as a func...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2009.0113
更新日期:2010-05-01 00:00:00
abstract::Existing standards of the management of the diabetic patients are not efficient enough, and further improvement is needed. The major objective of this paper is to present and discuss the therapeutic effectiveness of an intensive care telematic system designed and applied for intensive treatment of pregnant type 1 diab...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章
doi:10.1089/15209150152811207
更新日期:2001-01-01 00:00:00
abstract:BACKGROUND AND OBJECTIVE:Hyperglycemia occurs commonly in patients admitted to medical intensive care units (MICUs). Whether real-time (RT) continuous glucose monitoring (CGM) improves glycemic control and variability and reduces hypoglycemia in severely ill MICU patients with an Acute Physiology and Chronic Health Eva...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1089/dia.2015.0151
更新日期:2015-12-01 00:00:00
abstract:BACKGROUND:Computer simulation environments have been used in the development of many artificial pancreas systems. A glucose sensor model is an essential part of these environments, and different models have been proposed. However, not one of these models accounts for drop-outs of sensor readings, a well-known phenomen...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2014.0309
更新日期:2015-06-01 00:00:00
abstract:BACKGROUND:Relatively little is known about parents' or children's attitudes toward recruitment for, and participation in, studies of new diabetes technologies immediately after diagnosis. This study investigated factors affecting recruitment of participants for studies in newly diagnosed youth with type 1 diabetes. M...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2016.0157
更新日期:2016-09-01 00:00:00
abstract::Type 2 diabetes is thought to develop as a result of progressive beta-cell dysfunction in the setting of insulin resistance, leading to increased risks of microvascular and macrovascular complications. Type 2 diabetes is currently treated with diet and exercise, followed by oral drug therapy, and finally exogenous ins...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2006.8.385
更新日期:2006-06-01 00:00:00
abstract::Skin integrity and diabetes device placement are ongoing concerns for people with diabetes who utilize continuous glucose monitors (CGMs) and continuous subcutaneous insulin infusion pumps. This is especially significant for individuals with skin sensitivities, pediatric patients, and those who use devices chronically...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2018.0080
更新日期:2018-06-01 00:00:00
abstract:BACKGROUND:This exploratory study examined the pharmacokinetics and pharmacodynamics of a Bentley Pharmaceuticals, Inc. (North Hampton, NH) proprietary insulin formulation utilizing CPE-215 technology designed for intranasal administration. METHODS:Eight fasting healthy volunteers (four men, four women; body mass inde...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章
doi:10.1089/dia.2005.7.124
更新日期:2005-02-01 00:00:00
abstract::Glucagon-like peptide 1 receptor agonists (GLP-1 RAs) are highly effective at lowering hemoglobin A1c (HbA1c) and facilitating weight loss. Four agents in the GLP-1 RA class, albiglutide, liraglutide, dulaglutide, and semaglutide, also have cardioprotective effects. However, subcutaneous administration of these agents...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2019.0185
更新日期:2020-01-01 00:00:00
abstract::The microdialysis technique allows extraction of substances (e.g., glucose) from fluids in the human body for quantitative measurements ex vivo. The microdialysis catheter can be inserted in many different tissues; for continuous glucose monitoring it is most often implanted in the subcutaneous fat tissue in the abdom...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/152091503322250578
更新日期:2003-01-01 00:00:00
abstract:BACKGROUND:Balance is sensed through peripheral and central receptors and mediated by central control through the brain and spinal cord. Although some evidence exists as to the areas of the brain involved and how processing of data occurs in young individuals, nothing has been published on people with diabetes. The pur...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2012.0152
更新日期:2012-11-01 00:00:00
abstract::The World Wide Web has become remarkably quickly an alternative source of information for patients and their relatives, as well as students and health-care professionals. A whole plethora of websites and Internet-based applications related to diabetes have appeared in recent years. In this column, selected issues surr...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2005.7.225
更新日期:2005-02-01 00:00:00
abstract:OBJECTIVE:Over the past 35 years considerable research has been performed toward the investigation of noninvasive and minimally invasive glucose monitoring techniques. Optical polarimetry is one noninvasive technique that has shown promise as a means to ascertain blood glucose levels through measuring the glucose conce...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2012.0070
更新日期:2012-09-01 00:00:00
abstract:BACKGROUND:Continuous glucose monitoring (CGM) time-series are often analyzed, retrospectively, to investigate glucose variability (GV), a risk factor for the development of complications in type 1 diabetes (T1D). In the literature, several tens of different indices for GV quantification have been proposed, but many of...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,meta分析
doi:10.1089/dia.2013.0252
更新日期:2014-10-01 00:00:00
abstract::It is becoming increasingly acknowledged that people with Type 2 Diabetes represent what can be termed "an enriched population": a group that has the greatest risk of morbidity and mortality from cardiovascular diseases such as myocardial infarcts and strokes. Due to the tremendous toll, both human and financial, that...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/15209150050025258
更新日期:2000-07-01 00:00:00
abstract:: Background: Continuous glucose monitoring (CGM) systems are widely and increasingly used in diabetes self-management and in the context of clinic visits. However, access to CGM data during visits can be challenging. Clinic inefficiencies can restrict the time available for...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2019.0377
更新日期:2020-08-01 00:00:00
abstract:BACKGROUND:This study evaluated whether education and use of the advanced meter features of the CONTOUR(®) (Bayer HealthCare LLC, Diabetes Care, Tarrytown, NY) blood glucose monitoring system (BGMS) affect the frequency and pattern of blood glucose testing in insulin-using subjects with diabetes who routinely perform s...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1089/dia.2012.0051
更新日期:2012-10-01 00:00:00
abstract:BACKGROUND:Vascular endothelial growth factor (VEGF) is involved in the pathogenesis of diabetic microvascular disease. Most diabetes patients have higher serum levels of ferritin that may participate in diabetic vascular complications through high oxidative stress induced by iron. However, the mechanistic link between...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2013.0181
更新日期:2014-04-01 00:00:00
abstract:BACKGROUND:Glutamic acid decarboxylase-65 (GAD65) is a major autoantigen in autoimmune diabetes and is discharged from injured islet beta cells. GAD65 may also be released by transplanted islets undergoing immunological rejection. To test hypotheses regarding the utility of GAD65 as a biomarker for transplant rejection...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2006.8.207
更新日期:2006-04-01 00:00:00
abstract::This study was designed to determine plasma glucose and insulin levels after administration of three escalating doses of the oral insulin product hexyl-insulin monoconjugate 2 (HIM2) in fasting, insulin-deprived adult patients with type 1 diabetes. The study was also designed to assess the safety of the product. Sixte...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/152091502760306544
更新日期:2002-01-01 00:00:00
abstract:BACKGROUND:Narcolepsy is a severe sleep disorder that in most patients is characterized by the deficiency of central orexin. Clinically, narcolepsy is associated with obesity. Currently, there is a literature controversy about the potential alteration of leptin levels in narcoleptic patients. Theoretically, diminished ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2006.0037
更新日期:2007-08-01 00:00:00
abstract::Chromium (Cr) picolinate (CrPic) is a widely used nutritional supplement for optimal insulin function. A relationship among Cr status, diabetes, and associated pathologies has been established. Virtually all trials using CrPic supplementation for subjects with diabetes have demonstrated beneficial effects. Thirteen of...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2006.8.677
更新日期:2006-12-01 00:00:00
abstract:BACKGROUND:Previous studies of aerobic exercise have found lower sensor accuracy during exercise. Whether or not resistance exercise would also be associated with lower sensor accuracy has not yet been examined. This study sought to investigate the accuracy of continuous glucose monitoring sensor values at rest, during...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2012.0182
更新日期:2013-01-01 00:00:00
abstract:AIMS:Recent advances in analytical technology allow the detection of several hundred volatile organic compounds (VOCs) in human exhaled air, many of which reflect unidentified endogenous pathways. This study was performed to determine whether a breath gas analysis using proton transfer reaction-mass spectrometry (PTR-M...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2009.0181
更新日期:2010-06-01 00:00:00