Advanced meter features improve postprandial and paired self-monitoring of blood glucose in individuals with diabetes: results of the Actions with the CONTOUR Blood Glucose Meter and Behaviors in Frequent Testers (ACT) study.

Abstract:

BACKGROUND:This study evaluated whether education and use of the advanced meter features of the CONTOUR(®) (Bayer HealthCare LLC, Diabetes Care, Tarrytown, NY) blood glucose monitoring system (BGMS) affect the frequency and pattern of blood glucose testing in insulin-using subjects with diabetes who routinely perform self-monitoring of blood glucose (SMBG). SUBJECTS AND METHODS:Insulin-using subjects with type 1 or type 2 diabetes were enrolled in this 6-month, multicenter, prospective study and randomized to one of two groups. The basic meter features group (BMF group) received basic instruction in the use of the BGMS, whereas the advanced meter features group (AMF group) also received training in the use of advanced features, including the meal marker and audible reminder, and were instructed to use these features. Both groups received education on the importance of postprandial testing. RESULTS:The AMF group (n=105) had significantly greater average weekly postprandial blood glucose testing than the BMF group (n=106) at each follow-up visit (P<0.001) and significantly increased the frequency of paired blood glucose testing (P<0.001) as well. In both groups, glycated hemoglobin decreased significantly as postprandial testing frequency increased (P<0.05). Subject reports indicated that use of advanced features made postmeal SMBG considerably easier to remember, helped them better understand how to make decisions on their own, and increased their confidence in meal choices. CONCLUSIONS:Study findings showed that advanced features of the CONTOUR BGMS increased structured testing as measured by postprandial and paired SMBG and were perceived as useful by patients.

journal_name

Diabetes Technol Ther

authors

Bergenstal RM,Bode BW,Tamler R,Trence DL,Stenger P,Schachner HC,Fullam J,Pardo S,Kohut T,Fisher WA

doi

10.1089/dia.2012.0051

subject

Has Abstract

pub_date

2012-10-01 00:00:00

pages

851-7

issue

10

eissn

1520-9156

issn

1557-8593

journal_volume

14

pub_type

杂志文章,多中心研究,随机对照试验
  • Continuous glucose monitoring and diabetes health outcomes: a critical appraisal.

    abstract::This paper presents a critical review of continuous glucose monitoring studies that address accuracy, utility in assessing glucose variability, detection of hypoglycemia for improved metabolic control or reduced glucose variability, impact on quality of life, reduced fear of hypoglycemia, and applicability in helping ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2007.0261

    authors: Reach G

    更新日期:2008-04-01 00:00:00

  • Reduction in hemoglobin A1C with real-time continuous glucose monitoring: results from a 12-week observational study.

    abstract:BACKGROUND:Real-time continuous glucose monitoring (CGM) was studied in 140 adults with diabetes over a 12-week period of home use. Hemoglobin A(1c)(HbA1c) was measured on day 1 (baseline) and at weeks 6 and 12. METHODS:On day 1, participants received the CGM device (STS(R) System, DexCom, Inc., San Diego, CA) and und...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1089/dia.2007.0205

    authors: Bailey TS,Zisser HC,Garg SK

    更新日期:2007-06-01 00:00:00

  • Self-monitoring of blood glucose in diabetes: from evidence to clinical reality in Central and Eastern Europe--recommendations from the international Central-Eastern European expert group.

    abstract::Self-monitoring of blood glucose (SMBG) is universally considered to be an integral part of type 1 diabetes management and crucial for optimizing the safety and efficacy of complex insulin regimens. This extends to type 2 diabetes patients on intensive insulin therapy, and there is also a growing body of evidence sugg...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2013.0302

    authors: Czupryniak L,Barkai L,Bolgarska S,Bronisz A,Broz J,Cypryk K,Honka M,Janez A,Krnic M,Lalic N,Martinka E,Rahelic D,Roman G,Tankova T,Várkonyi T,Wolnik B,Zherdova N

    更新日期:2014-07-01 00:00:00

  • A pilot study of the SPRINT protocol for tight glycemic control in critically Ill patients.

    abstract:BACKGROUND:Stress-induced hyperglycemia is prevalent in critical care, even in patients with no history of diabetes. Increased counter-regulatory hormone response increases gluconeogenesis and effective insulin resistance, which can be exacerbated by drug therapy. Control of blood glucose levels to the 4.0-6.1 mmol/L r...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2006.8.449

    authors: Lonergan T,Compte AL,Willacy M,Chase JG,Shaw GM,Hann CE,Lotz T,Lin J,Wong XW

    更新日期:2006-08-01 00:00:00

  • Efficacy and Safety of Biosimilar SAR342434 Insulin Lispro in Adults with Type 1 Diabetes Also Using Insulin Glargine-SORELLA 1 Study.

    abstract:BACKGROUND:SAR342434 is a biosimilar follow-on of insulin lispro-Humalog®. This study aimed to show similar efficacy, safety, and immunogenicity of SAR342434 (SAR-Lis) versus insulin lispro-Humalog (Ly-Lis) in adult patients with type 1 diabetes (T1DM) treated with multiple daily injections while using basal insulin gl...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1089/dia.2017.0117

    authors: Garg SK,Wernicke-Panten K,Rojeski M,Pierre S,Kirchhein Y,Jedynasty K

    更新日期:2017-09-01 00:00:00

  • A Feasibility Study of Paired Continuous Glucose Monitoring Intrapartum and in the Newborn in Pregnancies Complicated by Type 1 Diabetes.

    abstract:AIM:To describe the continuous glucose monitoring (CGM) profiles of type 1 diabetes (T1D) offspring in the early neonatal period and its association with maternal intrapartum glucose control. METHODS:A prospective observational study of T1D pregnant women and their neonatal offspring. Women had a CGM sensor inserted 2...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0221

    authors: Stewart ZA,Thomson L,Murphy HR,Beardsall K

    更新日期:2019-01-01 00:00:00

  • Continuous glucose monitoring in patients undergoing cardiac surgery.

    abstract:OBJECTIVES:Hyperglycemia is a prominent feature among patients exposed to major stress such as in cardiac surgery. The implementation of a continuous glucose monitoring system (CGMS) for glucose monitoring during cardiac surgery was assessed. SUBJECTS AND METHODS:Fifty-nine consecutive patients who underwent cardiac s...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2011.0154

    authors: Kalmovich B,Bar-Dayan Y,Boaz M,Wainstein J

    更新日期:2012-03-01 00:00:00

  • Family perceptions of insulin pump adverse events in children and adolescents.

    abstract:BACKGROUND:Insulin pumps (for continuous subcutaneous insulin infusion [CSII]) are used widely in type 1 diabetes mellitus. Although there has been considerable study of outcomes, there are few recent data on CSII-associated adverse events and no data on family perceptions of adverse events and their confidence in deal...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2013.0315

    authors: Wheeler BJ,Donaghue KC,Heels K,Ambler GR

    更新日期:2014-04-01 00:00:00

  • Inaccurate Glucose Sensor Values After Hydroxyurea Administration.

    abstract:: Objective: To assess the degree, duration, mean absolute relative difference (MARD), and error analysis of discrepant values per continuous glucose monitoring (CGM) systems after hydroxyurea (HU) administration. Research Design and Methods: ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2020.0490

    authors: Tellez SE,Hornung LN,Courter JD,Abu-El-Haija M,Nathan JD,Lawson SA,Elder DA

    更新日期:2020-12-30 00:00:00

  • Incidence and Predictors of Dysglycemia and Regression to Normoglycemia in Indian Adolescents and Young Adults: 10-Year Follow-Up of the ORANGE Study.

    abstract:: Background: The prevalence of diabetes in youth is increasing worldwide in parallel with the obesity epidemic. This study aimed to determine the incidence rates of dysglycemia (diabetes or prediabetes) and evaluate the predictors of its progression or regression to normal ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2020.0109

    authors: Mehreen TS,Kamalesh R,Pandiyan D,Kumar DS,Anjana RM,Mohan V,Ranjani H

    更新日期:2020-12-01 00:00:00

  • The influence of environmental temperature on the response of the skin to local pressure: the impact of aging and diabetes.

    abstract:BACKGROUND:To protect against ischemia, pressure-induced vasodilation (PIV) causes an increase in skin blood flow. Endothelial dysfunction, which is commonly found in older patients and those with diabetes, and global temperatures can affect the resting blood flow in skin, which may reduce the blood flow during and aft...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2009.0097

    authors: McLellan K,Petrofsky JS,Zimmerman G,Lohman E,Prowse M,Schwab E,Lee S

    更新日期:2009-12-01 00:00:00

  • Poor agreement of computerized calculators for mean amplitude of glycemic excursions.

    abstract:BACKGROUND:Glucose variability has been identified as a predictor of hypoglycemia and has been associated with mortality in critically ill patients without diabetes. A popular metric to quantify glucose variability is the mean amplitude of glycemic excursions (MAGE). The "ruler and pencil" approach to calculate MAGE is...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2013.0138

    authors: Sechterberger MK,Luijf YM,Devries JH

    更新日期:2014-02-01 00:00:00

  • Can continuous subcutaneous insulin infusion improve health-related quality of life in patients with Shwachman-Bodian-Diamond syndrome and diabetes?

    abstract::We report the first case of the use of continuous subcutaneous insulin infusion (CSII) in a patient with Shwachman-Bodian-Diamond syndrome (SBDS) and diabetes. An Italian boy received diagnosis of SBDS at the age of 7 months (SBDS gene mutation: c.183-184TA → CT and c.258 + 2 T → C in compound heterozygous). The patie...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2014.0184

    authors: Terlizzi V,Zito E,Mozzillo E,Raia V,Franzese A

    更新日期:2015-01-01 00:00:00

  • Self-Monitoring of Blood Glucose (SMBG) in insulin- and non-insulin-using adults with diabetes: consensus recommendations for improving SMBG accuracy, utilization, and research.

    abstract::Current clinical guidelines for diabetes care encourage self-monitoring of blood glucose (SMBG) to improve glycemic control. Specific protocols remain variable, however, particularly among non-insulin-using patients. This is due in part to efficacy studies that neglect to consider (1) the performance of monitoring equ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2008.0104

    authors: Hirsch IB,Bode BW,Childs BP,Close KL,Fisher WA,Gavin JR,Ginsberg BH,Raine CH,Verderese CA

    更新日期:2008-12-01 00:00:00

  • Evaluating the accuracy, reliability, and clinical applicability of continuous glucose monitoring (CGM): Is CGM ready for real time?

    abstract:BACKGROUND:This study was designed to assess the accuracy, reliability, and contribution to clinical decision-making of two commercially available continuous glucose monitoring (CGM) devices using a novel analytical approach. STUDY DESIGN:Eleven individuals with type 1 diabetes and five with type 2 diabetes wore a Gua...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2008.0041

    authors: Mazze RS,Strock E,Borgman S,Wesley D,Stout P,Racchini J

    更新日期:2009-01-01 00:00:00

  • Factors associated with persistence and resumption of insulin pen use for patients with type 2 diabetes.

    abstract:OBJECTIVE:this study assessed patient-related factors associated with persistence and resumption of using pens as insulin delivery devices. METHODS:patients (n = 549; 300 current pen users, 249 former pen users) were recruited from national panels to participate in computer-assisted telephone interviews. Measures incl...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2010.0128

    authors: Peyrot M,Rubin RR

    更新日期:2011-01-01 00:00:00

  • Role of Continuous Glucose Monitoring in Clinical Trials: Recommendations on Reporting.

    abstract::Thanks to significant improvements in the precision, accuracy, and usability of continuous glucose monitoring (CGM), its relevance in both ambulatory diabetes care and clinical research is increasing. In this study, we address the latter perspective and derive provisional reporting recommendations. CGM systems have be...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2017.0054

    authors: Schnell O,Barnard K,Bergenstal R,Bosi E,Garg S,Guerci B,Haak T,Hirsch IB,Ji L,Joshi SR,Kamp M,Laffel L,Mathieu C,Polonsky WH,Snoek F,Home P

    更新日期:2017-07-01 00:00:00

  • Description and preliminary evaluation of a Multiagent Intelligent Dosing System (MAIDS) to manage combination insulin-oral agent therapy in type 2 diabetes.

    abstract:BACKGROUND:Computer decision support systems are potentially effective methods for adjusting insulin, but current models do not take into account simultaneous changes of more than one agent. We describe the development of the Multiagent Intelligent Dosing System (MAIDS, Dimensional Dosing Systems, Wexford, PA) for pred...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2005.7.937

    authors: Cook CB,McMichael JP,Dunbar VG,Lieberman R

    更新日期:2005-12-01 00:00:00

  • A recent survey confirms the efficacy and the safety of implanted insulin pumps during long-term use in poorly controlled type 1 diabetes patients.

    abstract:BACKGROUND:This article reports a prolonged trial with insulin pumps implanted in patients with type 1 diabetes showing poor glucose control and a high rate of complications. METHODS:We reviewed data from 181 patients undergoing implanted insulin pump therapy. Analysis included hemoglobin A1c (HbA1c) values, body weig...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2010.0209

    authors: Schaepelynck P,Renard E,Jeandidier N,Hanaire H,Fermon C,Rudoni S,Catargi B,Riveline JP,Guerci B,Millot L,Martin JF,Sola A,EVADIAC Group.

    更新日期:2011-06-01 00:00:00

  • Psychosocial correlates of continuous glucose monitoring use in youth and adults with type 1 diabetes and parents of youth.

    abstract:BACKGROUND:Continuous glucose monitoring (CGM) has been shown to improve glycemic control and reduce hypoglycemia with consistent use. Youth, however, are unlikely to use CGM consistently. We compared psychological characteristics of youth with type 1 diabetes, their parents, and adults with type 1 diabetes randomized ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2011.0201

    authors: Markowitz JT,Pratt K,Aggarwal J,Volkening LK,Laffel LM

    更新日期:2012-06-01 00:00:00

  • Clinical predictors of glycosylated hemoglobin response to thiazolidinedione therapy.

    abstract:BACKGROUND:The aim of this investigation was to assess clinical predictors of the glycosylated hemoglobin (HbA1C) response after the addition of a thiazolidinedione (TZD) to a biguanide, a sulfonylurea, or both in subjects with type 2 diabetes. METHODS:Chart review (n = 68 physicians) was used to identify consecutive ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2007.0248

    authors: Izumi R,Hurt J,Maki KC,Bell M,Zavras AI,McCamish M

    更新日期:2007-12-01 00:00:00

  • Determining clinical and psychological benefits and barriers with continuous glucose monitoring therapy.

    abstract:BACKGROUND:Preventing the complications of diabetes requires tight control and minimizing blood glucose fluctuation. Pursuing these goals increases the risk of severe hypoglycemia. The authors hoped to identify if using continuous glucose monitoring (CGM) decreased the incidence of severe hypoglycemia, resulted in less...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2009.0121

    authors: Halford J,Harris C

    更新日期:2010-03-01 00:00:00

  • Assessment of a new insulin preparation for implanted pumps used in the treatment of type 1 diabetes.

    abstract:BACKGROUND:Implanted insulin pumps using the peritoneal route provide long-term improvement of glucose control compared with subcutaneous insulin therapy in type 1 diabetes (T1D) patients. The stability of insulin preparation is critical for a safe use in implanted pumps. Insuman implantable(®) (400 IU/mL) (Sanofi-Aven...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1089/dia.2013.0369

    authors: Schaepelynck P,Riveline JP,Renard E,Hanaire H,Guerci B,Baillot-Rudoni S,Sola-Gazagnes A,Catargi B,Fontaine P,Millot L,Martin JF,Tachouaft H,Jeandidier N,EVADIAC Group.

    更新日期:2014-09-01 00:00:00

  • Glycemic Variability Is Associated with Frequency of Blood Glucose Testing and Bolus: Post Hoc Analysis Results from the ProAct Study.

    abstract:INTRODUCTION:The ProAct study has shown that a pump switch to the Accu-Chek(®) Combo system (Roche Diagnostics Deutschland GmbH, Mannheim, Germany) in type 1 diabetes patients results in stable glycemic control with significant improvements in glycated hemoglobin (HbA1c) in patients with unsatisfactory baseline HbA1c a...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1089/dia.2014.0278

    authors: Pfützner A,Weissmann J,Mougiakakou S,Daskalaki E,Weis N,Ziegler R

    更新日期:2015-06-01 00:00:00

  • Resistance to Data Loss of Glycemic Variability Measurements in Long-Term Continuous Glucose Monitoring.

    abstract:: Background: Continuous glucose monitoring (CGM) is a method of estimating blood glucose values from those recorded in the interstitial fluid. Because increasingly longer CGM measurements are possible, errors and data loss become more and more likely and potentially more da...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0247

    authors: Kucharski P,Pagacz K,Szadkowska A,Młynarski W,Romanowski A,Fendler W

    更新日期:2018-12-01 00:00:00

  • Combination antihypertensive therapy in the treatment of diabetic nephropathy.

    abstract::Diabetic nephropathy is one of the major causes of end-stage renal disease and is often associated with other macrovascular complications such as ischemic heart disease and peripheral vascular disease. Angiotensin converting enzyme inhibitors (ACE-I) and angiotensin II receptor blockers (AIIR) have both been shown to ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/152091502760098456

    authors: Boner G,Cao Z,Cooper ME

    更新日期:2002-01-01 00:00:00

  • Performance evaluation of the MiniMed continuous glucose monitoring system during patient home use.

    abstract:BACKGROUND:The recent availability of a continuous glucose monitor offers the opportunity to match the demands of intensive diabetes management with a period of equally intensive blood glucose monitoring. The present study evaluates the performance of the MiniMed continuous glucose monitoring system (CGMS) in patients ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/152091500316737

    authors: Gross TM,Bode BW,Einhorn D,Kayne DM,Reed JH,White NH,Mastrototaro JJ

    更新日期:2000-04-01 00:00:00

  • A comparison between simplified and intensive dose-titration algorithms using AIR inhaled insulin for insulin-naive patients with type 2 diabetes in a randomized noninferiority trial.

    abstract:BACKGROUND:Insulin initiation and optimization is a challenge for patients with type 2 diabetes. Our objective was to determine whether safety and efficacy of AIR inhaled insulin (Eli Lilly and Co., Indianapolis, IN) (AIR is a registered trademark of Alkermes, Inc., Cambridge, MA) using a simplified regimen was noninfe...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2009.0036

    authors: Mathieu C,Cuddihy R,Arakaki RF,Belin RM,Planquois JM,Lyons JN,Heilmann CR

    更新日期:2009-09-01 00:00:00

  • Accuracy of continuous glucose monitoring during exercise in type 1 diabetes pregnancy.

    abstract:BACKGROUND:Performance of continuous glucose monitors (CGMs) may be lower when glucose levels are changing rapidly, such as occurs during physical activity. Our aim was to evaluate accuracy of a current-generation CGM during moderate-intensity exercise in type 1 diabetes (T1D) pregnancy. SUBJECTS AND METHODS:As part o...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2012.0292

    authors: Kumareswaran K,Elleri D,Allen JM,Caldwell K,Nodale M,Wilinska ME,Amiel SA,Hovorka R,Murphy HR

    更新日期:2013-03-01 00:00:00

  • Non-invasive glucose measurement technologies: an update from 1999 to the dawn of the new millennium.

    abstract::There are three main issues in non-invasive (NI) glucose measurements: namely, specificity, compartmentalization of glucose values, and calibration. There has been progress in the use of near-infrared and mid-infrared spectroscopy. Recently new glucose measurement methods have been developed, exploiting the effect of ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2004.6.660

    authors: Khalil OS

    更新日期:2004-10-01 00:00:00