Abstract:
BACKGROUND:Preventing the complications of diabetes requires tight control and minimizing blood glucose fluctuation. Pursuing these goals increases the risk of severe hypoglycemia. The authors hoped to identify if using continuous glucose monitoring (CGM) decreased the incidence of severe hypoglycemia, resulted in less fear of hypoglycemia, and improved patient empowerment and what impact CCM had on quality of life (QOL) issues. METHODS:Questionnaires were used to gather demographic data, to measure educational experiences with CGM, QOL issues concerning fear of hypoglycemia and severe hypoglycemia, confidence to make changes to insulin regimens before and after using CGM, and the incidence of severe hypoglycemia before and while using CGM, and to assess the impact of CGM on QOL. RESULTS:The data and answers reported suggest significantly less fear of hypoglycemia and severe hypoglycemia and increased patient empowerment with CGM. Further shown is a reduced incidence of acute complications as evidenced by significantly decreased incidence of severe hypoglycemia. CGM appears to have a significant, positive impact on the stress associated with having and managing diabetes. CONCLUSIONS:Using CGM as part of the diabetes self-management plan offers the potential to significantly improve user outcomes as measured by QOL, reduction of fear, and patient empowerment. Using CGM can allow patients to achieve tighter control of their blood glucose values with reduced fear of hypoglycemia, reduced incidence of severe hypoglycemia, and a decreased sense of burden from having diabetes.
journal_name
Diabetes Technol Therjournal_title
Diabetes technology & therapeuticsauthors
Halford J,Harris Cdoi
10.1089/dia.2009.0121subject
Has Abstractpub_date
2010-03-01 00:00:00pages
201-5issue
3eissn
1520-9156issn
1557-8593journal_volume
12pub_type
杂志文章abstract::The microdialysis technique allows extraction of substances (e.g., glucose) from fluids in the human body for quantitative measurements ex vivo. The microdialysis catheter can be inserted in many different tissues; for continuous glucose monitoring it is most often implanted in the subcutaneous fat tissue in the abdom...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/152091503322250578
更新日期:2003-01-01 00:00:00
abstract:AIMS:This study compared glycemic control and maternal and fetal outcomes in pregnant women with type 1 diabetes mellitus (T1DM) treated with multiple daily injections (MDI) or continuous subcutaneous insulin infusion (CSII) using regular (RI) or lispro (LP) insulin. METHODS:Three hundred fifteen consecutive singleton...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2010.0111
更新日期:2010-12-01 00:00:00
abstract:: Background: Glycemic variability (GV) is an important component of glycemic control for patients with type 1 diabetes (T1D). The inadequacy of existing measurements lies in the fact that they view the variability from different aspects, so that no consensus has been reache...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2019.0250
更新日期:2020-04-01 00:00:00
abstract::Self-monitoring of blood glucose was described as one of the most important advancements in diabetes management since the invention of insulin in 1920. Recent advances in glucose sensor technology for measuring interstitial glucose concentrations have challenged the dominance of glucose meters in diabetes management, ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2009.0002
更新日期:2009-06-01 00:00:00
abstract:BACKGROUND:Applying real-time learning into an artificial pancreas system could effectively track the unpredictable behavior of glucose-insulin dynamics and adjust insulin treatment accordingly. We describe a novel learning algorithm and its performance when integrated into the MD-Logic Artificial Pancreas (MDLAP) syst...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2010.0216
更新日期:2011-10-01 00:00:00
abstract:AIM:Insulin therapy induces remission in subjects with newly diagnosed type 2 diabetes mellitus (T2DM). This study assessed the insulin and C-peptide levels in newly diagnosed T2DM subjects during low-dose insulin therapy. SUBJECTS AND METHODS:Twenty newly diagnosed, drug-naive, T2DM patients without acute or chronic ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2010.0187
更新日期:2011-04-01 00:00:00
abstract:BACKGROUND:The value of self-monitoring of blood glucose (SMBG) for persons with type 2 diabetes who do not use insulin remains controversial. This observational study compares the likelihood of medication adherence and change in glycated hemoglobin (A1C) for non-insulin-using patients using SMBG versus those not using...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2012.0047
更新日期:2012-09-01 00:00:00
abstract:BACKGROUND:Diabetes in elderly adults is associated with an increased risk of fall. The aim of study was to determine whether a virtual reality exercise (VRE) program would improve balance, strength, gait, and falls efficacy in elderly adults with diabetes. SUBJECTS AND METHODS:Fifty-five subjects with diabetes mellit...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2013.0050
更新日期:2013-06-01 00:00:00
abstract::Thanks to significant improvements in the precision, accuracy, and usability of continuous glucose monitoring (CGM), its relevance in both ambulatory diabetes care and clinical research is increasing. In this study, we address the latter perspective and derive provisional reporting recommendations. CGM systems have be...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2017.0054
更新日期:2017-07-01 00:00:00
abstract:BACKGROUND:Microneedles have previously been used to deliver insulin to animal models, but not in human subjects. This study tested the hypothesis that hollow microneedles can deliver insulin to modulate blood glucose levels in subjects with type 1 diabetes in a minimally invasive manner. METHODS:This study was carrie...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2008.0103
更新日期:2009-06-01 00:00:00
abstract::There are three main issues in non-invasive (NI) glucose measurements: namely, specificity, compartmentalization of glucose values, and calibration. There has been progress in the use of near-infrared and mid-infrared spectroscopy. Recently new glucose measurement methods have been developed, exploiting the effect of ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2004.6.660
更新日期:2004-10-01 00:00:00
abstract:BACKGROUND:The present study evaluated the efficacy of biphasic human insulin 30 (BHI 30) in type 2 diabetes patients who had failed in therapy with two or more oral antidiabetes drugs (OADs). METHODS:This open-label, nonrandomized, 4-month, multicenter, clinical observational study was conducted in Shanghai, China. A...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究
doi:10.1089/dia.2011.0168
更新日期:2012-03-01 00:00:00
abstract:: Objective: To assess the safety and efficacy of a simplified initialization for the Tandem t:slim X2 Control-IQ hybrid closed-loop system, using parameters based on total daily insulin ("MyTDI") in adolescents with type 1 diabetes under usual activity and during periods of...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2019.0471
更新日期:2020-08-01 00:00:00
abstract:: Background: The use of real-time continuous glucose monitoring (rtCGM) systems has proved to positively impact the management of type 1 diabetes with the potential to lower HbA1c, reduce frequency and time spent in hypoglycemia, and lower glycemic variability. Nevertheless...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2018.0397
更新日期:2019-05-01 00:00:00
abstract:: Background: Continuous glucose monitoring (CGM) systems are widely and increasingly used in diabetes self-management and in the context of clinic visits. However, access to CGM data during visits can be challenging. Clinic inefficiencies can restrict the time available for...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2019.0377
更新日期:2020-08-01 00:00:00
abstract:BACKGROUND:Glucose variability (GV) has been increasingly (or more extensively) studied in patients with type 1 diabetes (T1D) in the ambulatory setting; limited data exist on GV in hospitalized patients with T1D. MATERIALS AND METHODS:Retrospective single center cohort study, we analyzed in-hospital glucose measureme...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2017.0107
更新日期:2017-10-01 00:00:00
abstract:BACKGROUND:To examine trimester-specific associations among glycemic variability, fetal growth, and birthweight in pregnancies with type 1 diabetes mellitus (Type 1 DM). METHODS:In this retrospective cohort study of 41 pregnant women with Type 1 DM, we used continuous glucose monitoring (CGM) data to calculate glycemi...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2017.0443
更新日期:2018-06-01 00:00:00
abstract:BACKGROUND:There are currently few data available on the long-term use of continuous subcutaneous insulin infusion (CSII) (insulin pump) therapy in children. METHODS:Charts from 291 youth with type 1 diabetes (T1D) who were treated with CSII therapy for at least 1 year were reviewed. Data analysis included hemoglobin ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2007.0214
更新日期:2007-10-01 00:00:00
abstract:BACKGROUND:Recent evidence emphasizes the importance of maintaining normoglycemia in critically ill patients to reduce morbidity and mortality. Different analytical methods of varying accuracy exist for obtaining and measuring blood glucose in critically ill patients. The purpose of this study was to determine if there...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2008.0263
更新日期:2008-06-01 00:00:00
abstract:BACKGROUND:Lipoprotein-associated phospholipase A₂ (Lp-PLA₂) is a lipoprotein-associated enzyme that cleaves oxidized phosphatidylcholines, generating pro-atherosclerotic lysophosphatidylcholine and oxidized free fatty acids. Lp-PLA₂ is independently associated with cardiovascular disease (CVD) in a variety of populati...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2010.0175
更新日期:2011-03-01 00:00:00
abstract:BACKGROUND:Long-term treatment is necessary to slow the progression of type 2 diabetes (T2D). Here, we examined the safety and efficacy of 6 years of treatment with exenatide once weekly (QW) among patients with T2D in the DURATION-1 trial. METHODS:The study enrolled patients aged ≥16 years with T2D treated primarily ...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章
doi:10.1089/dia.2016.0107
更新日期:2016-11-01 00:00:00
abstract:: Background: Continuous glucose monitoring (CGM) is a method of estimating blood glucose values from those recorded in the interstitial fluid. Because increasingly longer CGM measurements are possible, errors and data loss become more and more likely and potentially more da...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2018.0247
更新日期:2018-12-01 00:00:00
abstract::Current clinical guidelines for diabetes care encourage self-monitoring of blood glucose (SMBG) to improve glycemic control. Specific protocols remain variable, however, particularly among non-insulin-using patients. This is due in part to efficacy studies that neglect to consider (1) the performance of monitoring equ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2008.0104
更新日期:2008-12-01 00:00:00
abstract:BACKGROUND:Vascular endothelial growth factor (VEGF) is involved in the pathogenesis of diabetic microvascular disease. Most diabetes patients have higher serum levels of ferritin that may participate in diabetic vascular complications through high oxidative stress induced by iron. However, the mechanistic link between...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2013.0181
更新日期:2014-04-01 00:00:00
abstract::Continuous glucose monitoring (CGM) systems have been available for more than 15 years by now. However, market uptake is relatively low in most countries; in other words, relatively few patients with diabetes use CGM systems regularly. One major reason for the reluctance of patients to use CGM systems is the costs ass...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2015.0296
更新日期:2016-02-01 00:00:00
abstract:BACKGROUND:Real-time continuous glucose monitoring (CGM) was studied in 140 adults with diabetes over a 12-week period of home use. Hemoglobin A(1c)(HbA1c) was measured on day 1 (baseline) and at weeks 6 and 12. METHODS:On day 1, participants received the CGM device (STS(R) System, DexCom, Inc., San Diego, CA) and und...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章,多中心研究
doi:10.1089/dia.2007.0205
更新日期:2007-06-01 00:00:00
abstract:OBJECTIVE:This study assessed the association of serum adiponectin with carotid intimal medial thickness (IMT) in Asian Indians with different grades of glucose intolerance. METHODS:Subjects with normal glucose tolerance (NGT) (n = 520), impaired glucose tolerance (IGT) (n = 115), and type 2 diabetes mellitus (T2DM) (...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2009.0100
更新日期:2010-02-01 00:00:00
abstract:AIMS:Recent advances in analytical technology allow the detection of several hundred volatile organic compounds (VOCs) in human exhaled air, many of which reflect unidentified endogenous pathways. This study was performed to determine whether a breath gas analysis using proton transfer reaction-mass spectrometry (PTR-M...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2009.0181
更新日期:2010-06-01 00:00:00
abstract::The World Wide Web has become remarkably quickly an alternative source of information for patients and their relatives, as well as students and health-care professionals. A whole plethora of websites and Internet-based applications related to diabetes have appeared in recent years. In this column, selected issues surr...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2005.7.225
更新日期:2005-02-01 00:00:00
abstract::Diabetic nephropathy is one of the major causes of end-stage renal disease and is often associated with other macrovascular complications such as ischemic heart disease and peripheral vascular disease. Angiotensin converting enzyme inhibitors (ACE-I) and angiotensin II receptor blockers (AIIR) have both been shown to ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/152091502760098456
更新日期:2002-01-01 00:00:00