Improved glycemic control after long-term insulin pump use in pediatric patients with type 1 diabetes.

Abstract:

BACKGROUND:There are currently few data available on the long-term use of continuous subcutaneous insulin infusion (CSII) (insulin pump) therapy in children. METHODS:Charts from 291 youth with type 1 diabetes (T1D) who were treated with CSII therapy for at least 1 year were reviewed. Data analysis included hemoglobin A(1c)(HbA(1c)) values, body mass index (BMI) values, and the occurrence of severe hypoglycemia (SH) or diabetic ketoacidosis (DKA) events. RESULTS:For the 291 patients, the mean age (+/-SD) for beginning CSII therapy was 13.3 +/- 3.7 years. The mean duration of CSII was 3.7 +/- 1.9 years (range 1-9 years). The baseline HbA(1c) value was 8.7 +/- 1.0%, compared to 8.2 +/- 0.9% after 1 year (P < 0.0001). The most recent value for all patients was 8.3 +/- 1.3% (P < 0.0001 compared to the baseline values for the same subjects). There was no advantage in glycemic control in the teen years as a result of initiating CSII in the pre-teen years compared to the teen years. SH events decreased from 9.06 events per 100 patient-years before CSII therapy to 7.96 events per 100 patient-years while on CSII therapy. The incidence of DKA increased from 1.39 events pre-CSII to 3.98 events per 100 patient-years while on CSII therapy. BMI z-scores showed a nonsignificant increase. CONCLUSIONS:The long-term use of CSII in pediatric patients is beneficial in lowering mean HbA(1c) levels and the number of SH events. However, there was an increase in the number of DKA episodes.

journal_name

Diabetes Technol Ther

authors

Scrimgeour L,Cobry E,McFann K,Burdick P,Weimer C,Slover R,Chase HP

doi

10.1089/dia.2007.0214

subject

Has Abstract

pub_date

2007-10-01 00:00:00

pages

421-8

issue

5

eissn

1520-9156

issn

1557-8593

journal_volume

9

pub_type

杂志文章
  • Human factors research applied: the development of a personal touch screen insulin pump and users' perceptions of actual use.

    abstract:BACKGROUND:A brief history of the field of human factors research is covered, along with how this discipline is leveraged within medical device companies, to eliminate design flaws in products, in order to make them safe and effective for human use. The way in which human factors research was used to develop the t:slim...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究

    doi:10.1089/dia.2013.0098

    authors: Schaeffer NE

    更新日期:2013-10-01 00:00:00

  • Combination antihypertensive therapy in the treatment of diabetic nephropathy.

    abstract::Diabetic nephropathy is one of the major causes of end-stage renal disease and is often associated with other macrovascular complications such as ischemic heart disease and peripheral vascular disease. Angiotensin converting enzyme inhibitors (ACE-I) and angiotensin II receptor blockers (AIIR) have both been shown to ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/152091502760098456

    authors: Boner G,Cao Z,Cooper ME

    更新日期:2002-01-01 00:00:00

  • Basal plus basal-bolus approach in type 2 diabetes.

    abstract::Type 2 diabetes is characterized by insulin resistance and progressive β-cell deterioration. As β-cell function declines, most patients with type 2 diabetes treated with oral agents, in monotherapy or combination, will require insulin therapy. Addition of basal insulin (glargine, detemir, or NPH/neutral protamine lisp...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2011.0001

    authors: Ampudia-Blasco FJ,Rossetti P,Ascaso JF

    更新日期:2011-06-01 00:00:00

  • Evaluation of a new blood glucose monitoring system with auto-calibration.

    abstract:BACKGROUND:The Ascensia CONTOUR System (Bayer HealthCare LLC, Elkhart, IN) is a new blood glucose (BG) monitoring system (BGMS) that uses glucose dehydrogenase chemistry and that combines low sample volume, fast response time, an auto-control marking feature, and an auto-calibration function in a small package. METHOD...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究

    doi:10.1089/dia.2005.7.283

    authors: Kilo C,Pinson M,Joynes JO,Joseph H,Monhaut N,Parkes JL,Baum J

    更新日期:2005-04-01 00:00:00

  • Analysis of continuous glucose monitoring data from non-diabetic and diabetic children: a tale of two algorithms.

    abstract::Use of the Medtronic MiniMed Continuous Glucose Monitoring System (CGMS) in non-diabetic children has revealed many low and high sensor glucose (SG) values, suggesting that the original analytical algorithm (Solutions 2.0) might be overreading glycemic excursions. A revised algorithm (Solutions 3.0) was introduced in ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/152091503765691866

    authors: Weinzimer SA,DeLucia MC,Boland EA,Steffen A,Tamborlane WV

    更新日期:2003-01-01 00:00:00

  • Proteomic identification of human urinary biomarkers in diabetes mellitus type 2.

    abstract:BACKGROUND:During the proteomic era, one of the most rapidly growing areas in biomedical research is biomarker discovery, particularly using proteomic technologies. The urinary proteome is known to be a valuable field of study and has become one of the most attractive subdisciplines in clinical proteomics for human dis...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2010.0078

    authors: Riaz S,Alam SS,Srai SK,Skinner V,Riaz A,Akhtar MW

    更新日期:2010-12-01 00:00:00

  • Continuous Glucose Monitoring, Glycemic Variability, and Excessive Fetal Growth in Pregnancies Complicated by Type 1 Diabetes.

    abstract:BACKGROUND:To examine trimester-specific associations among glycemic variability, fetal growth, and birthweight in pregnancies with type 1 diabetes mellitus (Type 1 DM). METHODS:In this retrospective cohort study of 41 pregnant women with Type 1 DM, we used continuous glucose monitoring (CGM) data to calculate glycemi...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2017.0443

    authors: Mulla BM,Noor N,James-Todd T,Isganaitis E,Takoudes TC,Curran A,Warren CE,O'Brien KE,Brown FM

    更新日期:2018-06-01 00:00:00

  • Incidence and Predictors of Dysglycemia and Regression to Normoglycemia in Indian Adolescents and Young Adults: 10-Year Follow-Up of the ORANGE Study.

    abstract:: Background: The prevalence of diabetes in youth is increasing worldwide in parallel with the obesity epidemic. This study aimed to determine the incidence rates of dysglycemia (diabetes or prediabetes) and evaluate the predictors of its progression or regression to normal ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2020.0109

    authors: Mehreen TS,Kamalesh R,Pandiyan D,Kumar DS,Anjana RM,Mohan V,Ranjani H

    更新日期:2020-12-01 00:00:00

  • Recovery of β-cell functions with low-dose insulin therapy: study in newly diagnosed type 2 diabetes mellitus patients.

    abstract:AIM:Insulin therapy induces remission in subjects with newly diagnosed type 2 diabetes mellitus (T2DM). This study assessed the insulin and C-peptide levels in newly diagnosed T2DM subjects during low-dose insulin therapy. SUBJECTS AND METHODS:Twenty newly diagnosed, drug-naive, T2DM patients without acute or chronic ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2010.0187

    authors: Bhattacharya S,Ammini AC,Jyotsna V,Gupta N,Dwivedi S

    更新日期:2011-04-01 00:00:00

  • Daily glucose profiles in Japanese people with normal glucose tolerance as assessed by continuous glucose monitoring.

    abstract:BACKGROUND:Little information is available regarding glucose fluctuations in postprandial states and during the oral glucose tolerance test (OGTT) in Japanese people with normal glucose tolerance (NGT). METHODS:Glucose profiles of 27 Japanese people were measured for 4 days by using continuous glucose monitoring. A 75...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2008.0083

    authors: Tsujino D,Nishimura R,Taki K,Miyashita Y,Morimoto A,Tajima N

    更新日期:2009-07-01 00:00:00

  • Skin autofluorescence and complications of diabetes: does ethnic background or skin color matter?

    abstract:AIMS:Skin autofluorescence (AF) has been associated with complications of diabetes. We evaluated the influence of skin color and ethnicity on the association between skin AF and the presence of diabetes-related complications. MATERIALS AND METHODS:In a multiethnic type 2 diabetes cohort we investigated all patients wi...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2013.0374

    authors: Ahdi M,Gerdes VE,Graaff R,Kuipers S,Smit AJ,Meesters EW

    更新日期:2015-02-01 00:00:00

  • Continuous glucose monitoring and diabetes health outcomes: a critical appraisal.

    abstract::This paper presents a critical review of continuous glucose monitoring studies that address accuracy, utility in assessing glucose variability, detection of hypoglycemia for improved metabolic control or reduced glucose variability, impact on quality of life, reduced fear of hypoglycemia, and applicability in helping ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2007.0261

    authors: Reach G

    更新日期:2008-04-01 00:00:00

  • Evaluating rate of change as an index of glycemic variability, using continuous glucose monitoring data.

    abstract:BACKGROUND:There is no consensus as to the best method to assess glycemic variability from continuous glucose monitoring (CGM) data. Rate of change has been suggested as a preferred method of assessing glycemic variability, but this assertion has not been validated. METHODS:Forty-eight hours of CGM data were analyzed ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究

    doi:10.1089/dia.2010.0215

    authors: Whitelaw BC,Choudhary P,Hopkins D

    更新日期:2011-06-01 00:00:00

  • Efficacy and Safety of SGLT2 Inhibitors in Type 1 Diabetes After the Introduction of an Off-Label Use Protocol for Clinical Practice.

    abstract:: Aims: We evaluated the real-life efficacy and safety of empagliflozin in combination with optimized insulin therapy in patients with type 1 diabetes (T1D). Methods: This was a prospective study, including 27 patients with T1D t...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2019.0316

    authors: Bayona Cebada A,Nattero-Chávez L,Alonso Díaz S,Escobar-Morreale HF,Luque-Ramírez M

    更新日期:2020-03-01 00:00:00

  • Waist circumference identifies primary school children with metabolic syndrome abnormalities.

    abstract:OBJECTIVE:This study was designed to assess whether waist circumference can predict metabolic syndrome abnormalities in primary schoolchildren. RESEARCH DESIGN AND METHODS:Of 5,103 children (2,526 males) 4-13 years old who underwent anthropometric measurements, 530 had more extensive testing. Body mass index (BMI), wa...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究

    doi:10.1089/dia.2006.0017

    authors: Hirschler V,Maccallini G,Calcagno M,Aranda C,Jadzinsky M

    更新日期:2007-04-01 00:00:00

  • Poor agreement of computerized calculators for mean amplitude of glycemic excursions.

    abstract:BACKGROUND:Glucose variability has been identified as a predictor of hypoglycemia and has been associated with mortality in critically ill patients without diabetes. A popular metric to quantify glucose variability is the mean amplitude of glycemic excursions (MAGE). The "ruler and pencil" approach to calculate MAGE is...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2013.0138

    authors: Sechterberger MK,Luijf YM,Devries JH

    更新日期:2014-02-01 00:00:00

  • Immobilized glucose oxidase in implantable glucose sensor technology.

    abstract::Glucose oxidase has had a central role in previous glucose sensing methods and is key to the development of certain new glucose sensors. The immobilized enzyme is specific for glucose and sufficiently long-lived for many sensor applications, but new glucose sensing applications may place increased demands on the enzym...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/15209150050194242

    authors: Gough DA,Bremer T

    更新日期:2000-10-01 00:00:00

  • Nocturnal Glucose Metabolism in Type 1 Diabetes: A Study Comparing Single Versus Dual Tracer Approaches.

    abstract:BACKGROUND:Understanding the effect size, variability, and underlying physiology of the dawn phenomenon is important for next-generation closed-loop control algorithms for type 1 diabetes (T1D). SUBJECTS AND METHODS:We used an iterative protocol design to study 16 subjects with T1D on individualized insulin pump thera...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2015.0011

    authors: Mallad A,Hinshaw L,Dalla Man C,Cobelli C,Basu R,Lingineni R,Carter RE,Kudva YC,Basu A

    更新日期:2015-08-01 00:00:00

  • Study of Insulin Requirement Modeling in Hospitalized Elderly Patients with Type 2 Diabetes at a Late Stage of Stepwise Escalation Therapy.

    abstract:BACKGROUND:This study explored the relationships between exogenous insulin requirements and endogenous variables in elderly patients with type 2 diabetes (T2D). SUBJECTS AND METHODS:Patients with T2D 65 years of age or older were enrolled for a short hospitalization period in order to start or change their basal-bolus...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2015.0044

    authors: Nourizadeh-Sedaghati A,Herbin M,Lukas-Croisier C,Novella JL,Delemer B

    更新日期:2016-05-01 00:00:00

  • The association of self-monitoring of blood glucose use with medication adherence and glycemic control in patients with type 2 diabetes initiating non-insulin treatment.

    abstract:BACKGROUND:The value of self-monitoring of blood glucose (SMBG) for persons with type 2 diabetes who do not use insulin remains controversial. This observational study compares the likelihood of medication adherence and change in glycated hemoglobin (A1C) for non-insulin-using patients using SMBG versus those not using...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2012.0047

    authors: Virdi N,Daskiran M,Nigam S,Kozma C,Raja P

    更新日期:2012-09-01 00:00:00

  • Obesity and diabetes: newer concepts in imaging.

    abstract::Quantifying body fat is currently an area of active research. Recent studies have shown that the quantity and location of fat in different compartments have varying clinical significance. This information can now be obtained from computed tomography (CT) or magnetic resonance (MR), and it can inform clinical decision ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2013.0039

    authors: Garg K,Chang S,Scherzinger A

    更新日期:2013-05-01 00:00:00

  • Estimated Lifetime Economic Burden of Type 1 Diabetes.

    abstract:: Background: The financial strain of type 1 diabetes on the United States health care system, patients, and employers underscores the importance of developing novel treatments for the disease. This study estimated the lifetime economic burden attributable to type 1 diabetes...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2019.0398

    authors: Sussman M,Benner J,Haller MJ,Rewers M,Griffiths R

    更新日期:2020-02-01 00:00:00

  • Advanced meter features improve postprandial and paired self-monitoring of blood glucose in individuals with diabetes: results of the Actions with the CONTOUR Blood Glucose Meter and Behaviors in Frequent Testers (ACT) study.

    abstract:BACKGROUND:This study evaluated whether education and use of the advanced meter features of the CONTOUR(®) (Bayer HealthCare LLC, Diabetes Care, Tarrytown, NY) blood glucose monitoring system (BGMS) affect the frequency and pattern of blood glucose testing in insulin-using subjects with diabetes who routinely perform s...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1089/dia.2012.0051

    authors: Bergenstal RM,Bode BW,Tamler R,Trence DL,Stenger P,Schachner HC,Fullam J,Pardo S,Kohut T,Fisher WA

    更新日期:2012-10-01 00:00:00

  • Patient-reported outcomes in adults with type 2 diabetes using mealtime inhaled technosphere insulin and basal insulin versus premixed insulin.

    abstract:AIMS:This study assessed patient-reported outcomes in a multicenter study of adults with type 2 diabetes taking mealtime Technosphere(®) inhaled insulin (MannKind Corp., Valencia, CA) and basal insulin (insulin glargine) or premixed aspart insulin 70/30. METHODS:Subjects were 618 non-smoking adults with starting hemog...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1089/dia.2011.0037

    authors: Peyrot M,Rubin RR

    更新日期:2011-12-01 00:00:00

  • Nocturnal continuous glucose monitoring: accuracy and reliability of hypoglycemia detection in patients with type 1 diabetes at high risk of severe hypoglycemia.

    abstract:BACKGROUND:A reliable method to detect biochemical nocturnal hypoglycemia is highly needed, especially in patients with recurrent severe hypoglycemia. We evaluated reliability of nocturnal continuous glucose monitoring (CGM) in patients with type 1 diabetes at high risk of severe hypoglycemia. PATIENTS AND METHODS:Sev...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1089/dia.2013.0004

    authors: Bay C,Kristensen PL,Pedersen-Bjergaard U,Tarnow L,Thorsteinsson B

    更新日期:2013-05-01 00:00:00

  • Home blood glucose prediction: validation, safety, and efficacy testing in clinical diabetes.

    abstract:BACKGROUND:Patients with diabetes do daily self-monitoring of blood glucose (SMBG). For such patients, we devised an engine that predicts not only the expected blood glucose level at the next meal but also the pending risks of hypoglycemia. The purpose of this study was to validate the predictions and provide evidence ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2005.7.487

    authors: Albisser AM,Sakkal S,Wright C

    更新日期:2005-06-01 00:00:00

  • Glycemic Variability Is Associated with Frequency of Blood Glucose Testing and Bolus: Post Hoc Analysis Results from the ProAct Study.

    abstract:INTRODUCTION:The ProAct study has shown that a pump switch to the Accu-Chek(®) Combo system (Roche Diagnostics Deutschland GmbH, Mannheim, Germany) in type 1 diabetes patients results in stable glycemic control with significant improvements in glycated hemoglobin (HbA1c) in patients with unsatisfactory baseline HbA1c a...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1089/dia.2014.0278

    authors: Pfützner A,Weissmann J,Mougiakakou S,Daskalaki E,Weis N,Ziegler R

    更新日期:2015-06-01 00:00:00

  • Safety of drugs commonly used to treat hypertension, dyslipidemia, and Type 2 diabetes (the metabolic syndrome): part 2.

    abstract::It is becoming increasingly acknowledged that people with Type 2 Diabetes represent what can be termed "an enriched population": a group that has the greatest risk of morbidity and mortality from cardiovascular diseases such as myocardial infarcts and strokes. Due to the tremendous toll, both human and financial, that...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/15209150050025258

    authors: Marcus AO

    更新日期:2000-07-01 00:00:00

  • Adiponectin and carotid intimal medial thickness in subjects with and without glucose intolerance (CURES-82).

    abstract:OBJECTIVE:This study assessed the association of serum adiponectin with carotid intimal medial thickness (IMT) in Asian Indians with different grades of glucose intolerance. METHODS:Subjects with normal glucose tolerance (NGT) (n = 520), impaired glucose tolerance (IGT) (n = 115), and type 2 diabetes mellitus (T2DM) (...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2009.0100

    authors: Gokulakrishnan K,Indulekha K,Ganesan S,Anuradha S,Mohan V

    更新日期:2010-02-01 00:00:00

  • Capillary and venous blood glucose concentrations measured during intravenous insulin and glucose infusion: a comparison of steady and dynamic states.

    abstract:BACKGROUND:Patients undergoing intensive insulin therapy may have blood glucose (BG) samples drawn from arterial, capillary, or venous sources. This study compared capillary and venous BG across a range of glucose concentrations and under conditions of rapid change in BG. METHODS:Following a 10-h fast, 40 adult patien...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章

    doi:10.1089/dia.2009.0023

    authors: Kempe K,Price D,Ellison J,Marhoul J,Morrow L,Win K,Kuschma K,Hompesch M

    更新日期:2009-10-01 00:00:00