Abstract:
BACKGROUND:To examine trimester-specific associations among glycemic variability, fetal growth, and birthweight in pregnancies with type 1 diabetes mellitus (Type 1 DM). METHODS:In this retrospective cohort study of 41 pregnant women with Type 1 DM, we used continuous glucose monitoring (CGM) data to calculate glycemic variability (coefficient of variation of glucose) over a 7-day interval in each trimester. Clinical data, including fetal biometry, birthweight, and perinatal complications, were extracted from medical records. RESULTS:Women maintained good glycemic control during pregnancy, with mean HbA1c in the first, second, and third trimester 6.5%, 6.1%, and 6.4%, respectively. Sixty-three percent of infants were large for gestational age (LGA). Estimated fetal weight percentile (EFW%ile) and abdominal circumference percentile (AC%ile) increased during pregnancy, consistent with accelerated prenatal growth. Correlations between trimester-specific glycemic variability and EFW, AC, and birthweight were not statistically significant. After maternal age adjustment, glycemic variability was not associated with birthweight for any trimester (adj. β for first trimester: -38.46, 95% CI: -98.58 to 21.66; adj. β for second trimester: -12.20, 95% CI: -51.47 to 27.06; adj. β for third trimester: -26.26, 95% CI: -79.52 to 27.00). CONCLUSIONS:The occurrence of LGA remains very high in contemporary U.S. women with Type 1 DM, despite the use of CGM and overall good glycemic control. Neither HbA1c nor glycemic variability predicted fetal overgrowth or birthweight. Since LGA is a key driver of maternal and newborn complications in pregnancies with Type 1 DM, our data emphasize the importance of investigating both glucose-dependent and glucose-independent underlying mechanisms.
journal_name
Diabetes Technol Therjournal_title
Diabetes technology & therapeuticsauthors
Mulla BM,Noor N,James-Todd T,Isganaitis E,Takoudes TC,Curran A,Warren CE,O'Brien KE,Brown FMdoi
10.1089/dia.2017.0443subject
Has Abstractpub_date
2018-06-01 00:00:00pages
413-419issue
6eissn
1520-9156issn
1557-8593journal_volume
20pub_type
杂志文章abstract:BACKGROUND:The objective of this investigation was to evaluate the test-retest repeatability of insulin sensitivity and secretion indices derived from liquid meal tolerance tests (MTTs) in subjects with normal fasting glucose (NFG) (n = 20), impaired fasting glucose (IFG) (n = 20), or type 2 diabetes mellitus (n = 38)....
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2010.0083
更新日期:2010-11-01 00:00:00
abstract:BACKGROUND:The present study evaluated the efficacy of biphasic human insulin 30 (BHI 30) in type 2 diabetes patients who had failed in therapy with two or more oral antidiabetes drugs (OADs). METHODS:This open-label, nonrandomized, 4-month, multicenter, clinical observational study was conducted in Shanghai, China. A...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究
doi:10.1089/dia.2011.0168
更新日期:2012-03-01 00:00:00
abstract:OBJECTIVE:This study assessed the accuracy and reliability of three continuous glucose monitoring (CGM) systems. RESEARCH DESIGN AND METHODS:We studied the Animas® (West Chester, PA) Vibe™ with Dexcom® (San Diego, CA) G4™ version A sensor (G4A), the Abbott Diabetes Care (Alameda, CA) Freestyle® Navigator I (NAV), and ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1089/dia.2013.0049
更新日期:2013-08-01 00:00:00
abstract:BACKGROUND:Continuous glucose monitoring (CGM) has been shown to improve glycemic control and reduce hypoglycemia with consistent use. Youth, however, are unlikely to use CGM consistently. We compared psychological characteristics of youth with type 1 diabetes, their parents, and adults with type 1 diabetes randomized ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2011.0201
更新日期:2012-06-01 00:00:00
abstract::Glucagon-like peptide 1 receptor agonists (GLP-1 RAs) are highly effective at lowering hemoglobin A1c (HbA1c) and facilitating weight loss. Four agents in the GLP-1 RA class, albiglutide, liraglutide, dulaglutide, and semaglutide, also have cardioprotective effects. However, subcutaneous administration of these agents...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2019.0185
更新日期:2020-01-01 00:00:00
abstract:OBJECTIVES:We evaluated patterns of meal intake, insulin bolus delivery, and fingerstick glucose measurements during hybrid closed-loop and sensor-augmented pump (SAP) therapy, including associations with glucose control. METHODS:Data were retrospectively analyzed from pump-treated adults with type 1 diabetes who unde...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2016.0307
更新日期:2017-07-01 00:00:00
abstract:BACKGROUND:Type 1 diabetic patients have high instability of daily glucose levels. The aim of this study was to evaluate the long-term effects of continuous subcutaneous insulin infusion (CSII) therapy, compared with multiple daily injections of insulin (MDI), on glucose variability, in young type 1 diabetic patients t...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2017.0334
更新日期:2018-02-01 00:00:00
abstract:PURPOSE:This study investigated reasons for the rejection and discontinuation of insulin pump therapy and explored general attitudes towards this mode of therapy among young patients with type 1 diabetes. METHODS:A questionnaire was developed using a focus group of young people with diabetes. It was then used to surve...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2009.0080
更新日期:2010-01-01 00:00:00
abstract:: Background: We aimed to explore insulin pump settings in breastfeeding women with type 1 diabetes. Methods: Thirteen unselected breastfeeding women with type 1 diabetes on insulin pump therapy were included consecutively from A...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2019.0280
更新日期:2020-04-01 00:00:00
abstract:BACKGROUND:SAR342434 is a biosimilar follow-on of insulin lispro-Humalog®. This study aimed to show similar efficacy, safety, and immunogenicity of SAR342434 (SAR-Lis) versus insulin lispro-Humalog (Ly-Lis) in adult patients with type 1 diabetes (T1DM) treated with multiple daily injections while using basal insulin gl...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1089/dia.2017.0117
更新日期:2017-09-01 00:00:00
abstract:BACKGROUND:The quantitative analysis of glucose time-series can greatly help the management of diabetes. In particular, a static nonlinear transformation, which symmetrizes the distribution of glucose levels by bringing them in the so-called risk space, was proposed previously for both self-monitoring blood glucose and...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2011.0006
更新日期:2011-08-01 00:00:00
abstract::We report the first case of the use of continuous subcutaneous insulin infusion (CSII) in a patient with Shwachman-Bodian-Diamond syndrome (SBDS) and diabetes. An Italian boy received diagnosis of SBDS at the age of 7 months (SBDS gene mutation: c.183-184TA → CT and c.258 + 2 T → C in compound heterozygous). The patie...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2014.0184
更新日期:2015-01-01 00:00:00
abstract:BACKGROUND:Obesity surgery elicits complex changes in glucose metabolism that are difficult to observe with discontinuous glucose measurements. We aimed to evaluate glucose variability after gastric bypass by continuous glucose monitoring (CGM) in a real-life setting. METHODS:CGM was performed for 4.2 ± 1.3 days in th...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2010.0203
更新日期:2011-06-01 00:00:00
abstract:AIMS:Recent advances in analytical technology allow the detection of several hundred volatile organic compounds (VOCs) in human exhaled air, many of which reflect unidentified endogenous pathways. This study was performed to determine whether a breath gas analysis using proton transfer reaction-mass spectrometry (PTR-M...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2009.0181
更新日期:2010-06-01 00:00:00
abstract:BACKGROUND:Currently, it is still unknown whether differences in glycemic control have any effect on glucose and insulin kinetics after vildagliptin administration. The aim of this study was to evaluate the effect of vildagliptin on glucose and insulin concentrations during a 24-h period in type 2 diabetes patients wit...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2013.0020
更新日期:2013-07-01 00:00:00
abstract:BACKGROUND:Glucose monitoring based on sampling skin interstitial fluid (ISF) is being developed as an alternative to fingerstick blood glucose monitoring. Time delays between rapidly changing levels of glucose in blood and interstitial fluid have been reported in the literature to be between 5 and 20 minutes. This stu...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/152091599317530
更新日期:1999-04-01 00:00:00
abstract:BACKGROUND:To protect against ischemia, pressure-induced vasodilation (PIV) causes an increase in skin blood flow. Endothelial dysfunction, which is commonly found in older patients and those with diabetes, and global temperatures can affect the resting blood flow in skin, which may reduce the blood flow during and aft...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2009.0097
更新日期:2009-12-01 00:00:00
abstract:AIMS:This study assessed patient-reported outcomes in a multicenter study of adults with type 2 diabetes taking mealtime Technosphere(®) inhaled insulin (MannKind Corp., Valencia, CA) and basal insulin (insulin glargine) or premixed aspart insulin 70/30. METHODS:Subjects were 618 non-smoking adults with starting hemog...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章,多中心研究,随机对照试验
doi:10.1089/dia.2011.0037
更新日期:2011-12-01 00:00:00
abstract:: Background: The prevalence of diabetes in youth is increasing worldwide in parallel with the obesity epidemic. This study aimed to determine the incidence rates of dysglycemia (diabetes or prediabetes) and evaluate the predictors of its progression or regression to normal ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2020.0109
更新日期:2020-12-01 00:00:00
abstract::Background Glycated hemoglobin A1c (HbA1c) is a key biomarker in the glycemic management of individuals with diabetes but the relationship with glucose levels can be variable. A recent kinetic model has described a calculated HbA1c (cHbA1c) that is individual-specific. Our aim was to validate the routine clinical use ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2020.0553
更新日期:2021-01-04 00:00:00
abstract::Patients with diabetes play with a double-edged sword when it comes to deciding glucose and A1c target levels. On the one side, tight control has been shown to be crucial in avoiding long-term complications; on the other, tighter control leads to an increased risk of iatrogenic hypoglycemia, which is compounded when h...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2005.7.3
更新日期:2005-02-01 00:00:00
abstract:BACKGROUND:Weight gain often occurs when insulin therapy is initiated. The long-acting insulin analog insulin detemir has been shown to be effective and well tolerated when used in basal-bolus regimens or as an add-on to oral antidiabetic drugs (OADs) and causes less weight gain than other insulins. The aim of this exp...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1089/dia.2008.0282
更新日期:2008-08-01 00:00:00
abstract:BACKGROUND:The recent availability of a continuous glucose monitor offers the opportunity to match the demands of intensive diabetes management with a period of equally intensive blood glucose monitoring. The present study evaluates the performance of the MiniMed continuous glucose monitoring system (CGMS) in patients ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/152091500316737
更新日期:2000-04-01 00:00:00
abstract:BACKGROUND:Adherence to established standards (e.g., International Organization for Standardization [ISO] 15197) is important to ensure comparable and sufficient accuracy of systems for self-monitoring of blood glucose (SMBG). Accuracy evaluation was performed for different SMBG systems available in Europe with three r...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2015.0085
更新日期:2015-09-01 00:00:00
abstract::Since the late 1970s, self-monitoring of blood glucose has been the standard for assessing daily glycemic control. The first continuous glucose monitor became available in 1999. Numerous clinical trials have documented the benefits of continuous glucose monitoring (CGM) in patients with type 1 diabetes mellitus (DM). ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2011.0086
更新日期:2012-02-01 00:00:00
abstract::The Editor of Diabetes Technology & Therapeutics is officially retracting the article entitled, "No Deleterious Effect of Lockdown Due to COVID-19 Pandemic on Glycaemic Control, Measured by Glucose Monitoring, in Adults with Type 1 Diabetes," by Beato-Vibora PI. Diabetes Technol Ther 2020; epub DOI: 10.1089/dia.2020.0...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,收录出版
doi:10.1089/dia.2020.0184
更新日期:2020-05-12 00:00:00
abstract::Glucose oxidase has had a central role in previous glucose sensing methods and is key to the development of certain new glucose sensors. The immobilized enzyme is specific for glucose and sufficiently long-lived for many sensor applications, but new glucose sensing applications may place increased demands on the enzym...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/15209150050194242
更新日期:2000-10-01 00:00:00
abstract:BACKGROUND:There is no consensus as to the best method to assess glycemic variability from continuous glucose monitoring (CGM) data. Rate of change has been suggested as a preferred method of assessing glycemic variability, but this assertion has not been validated. METHODS:Forty-eight hours of CGM data were analyzed ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究
doi:10.1089/dia.2010.0215
更新日期:2011-06-01 00:00:00
abstract:AIM:Insulin therapy induces remission in subjects with newly diagnosed type 2 diabetes mellitus (T2DM). This study assessed the insulin and C-peptide levels in newly diagnosed T2DM subjects during low-dose insulin therapy. SUBJECTS AND METHODS:Twenty newly diagnosed, drug-naive, T2DM patients without acute or chronic ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2010.0187
更新日期:2011-04-01 00:00:00
abstract:BACKGROUND:The management of hyperglycemia in the intensive care unit has been a controversial topic for more than a decade, with target ranges varying from 80-110 mg/dL to <200 mg/dL. Multiple insulin infusion protocols exist, including several computerized protocols, which have attempted to achieve these targets. Imp...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2016.0101
更新日期:2016-08-01 00:00:00