Insulin Pump Settings During Breastfeeding in Women with Type 1 Diabetes.

Abstract:

: Background: We aimed to explore insulin pump settings in breastfeeding women with type 1 diabetes. Methods: Thirteen unselected breastfeeding women with type 1 diabetes on insulin pump therapy were included consecutively from April 2016 to October 2017. Blinded continuous glucose monitoring (CGM) for 6 days was applied at 1, 2, and 6 months after delivery. Recommendations were intake of 210 g carbohydrate daily while aiming for glucose target range 4.0-10.0 mmol/L and avoiding hypoglycemia. Immediately after delivery a reduction of total insulin dose by 30% of the prepregnancy dose was recommended. Insulin pump target glucose was 5.8 mmol/L. Results: Median diabetes duration was 22 (range 13-36) years. At 1, 2, and 6 months, 13, 11, and 8 women, respectively, were breastfeeding and spent ≥70.8% (25%-99%) of time in the glucose target range and ≤3.8% (0%-15.5%) of time with CGM <4.0 mmol/L at night-time and for 24 h. None of the women experienced severe hypoglycemia. HbA1c was 58 (47-72) mmol/mol and 52 (44-60) at 6 months and prepregnancy, respectively, P = 0.18. At 1, 2, and 6 months, the insulin pump settings remained almost stable with basal insulin rates (at 03.00, 08.00, 12.00, and 18.00) 14% lower and the carbohydrate-to-insulin ratios 10% higher than the prepregnancy settings. Conclusions: In breastfeeding women with type 1 diabetes who consumed sufficient amounts of carbohydrates and obtained appropriate glycemic control, the basal insulin rates were 14% lower and carbohydrate-to-insulin ratios 10% higher than before pregnancy. These data are useful when recommending insulin pump settings after delivery.

journal_name

Diabetes Technol Ther

authors

Nørgaard SK,Nørgaard K,Roskjær AB,Mathiesen ER,Ringholm L

doi

10.1089/dia.2019.0280

subject

Has Abstract

pub_date

2020-04-01 00:00:00

pages

314-320

issue

4

eissn

1520-9156

issn

1557-8593

journal_volume

22

pub_type

杂志文章
  • Prevalence of Diabetic Neuropathy in Young Adults with Type 1 Diabetes and the Association with Insulin Pump Therapy.

    abstract:AIMS:The aim was to investigate the prevalence of diabetic sensorimotor polyneuropathy (DSPN) and cardiovascular autonomic neuropathy (CAN) in a Danish population of young adults with type 1 diabetes (T1D) using both established and novel measuring modalities. Furthermore, to investigate the association between continu...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0249

    authors: Christensen MMB,Hommel EE,Jørgensen ME,von Scholten BJ,Fleischer J,Hansen CS

    更新日期:2018-11-21 00:00:00

  • Peripheral leptin levels in narcoleptic patients.

    abstract:BACKGROUND:Narcolepsy is a severe sleep disorder that in most patients is characterized by the deficiency of central orexin. Clinically, narcolepsy is associated with obesity. Currently, there is a literature controversy about the potential alteration of leptin levels in narcoleptic patients. Theoretically, diminished ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2006.0037

    authors: Dahmen N,Engel A,Helfrich J,Manderscheid N,Löbig M,Forst T,Pfützner A,Tonn P

    更新日期:2007-08-01 00:00:00

  • Development of optimal kids insulin dosing system formulas for young children with type 1 diabetes mellitus.

    abstract:OBJECTIVE:This study was designed to develop predictive formulas for precise insulin dosing in young children with type 1 diabetes (T1DM). RESEARCH DESIGN AND METHODS:Consecutive 1-year data from a group of 14 young patients (eight girls, six boys) 3.9 ± 0.8 years old with diabetes duration of 2.0 ± 0.8 years, transit...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2011.0184

    authors: Alemzadeh R,Hoffmann RG,Dasgupta M,Parton E

    更新日期:2012-05-01 00:00:00

  • Family perceptions of insulin pump adverse events in children and adolescents.

    abstract:BACKGROUND:Insulin pumps (for continuous subcutaneous insulin infusion [CSII]) are used widely in type 1 diabetes mellitus. Although there has been considerable study of outcomes, there are few recent data on CSII-associated adverse events and no data on family perceptions of adverse events and their confidence in deal...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2013.0315

    authors: Wheeler BJ,Donaghue KC,Heels K,Ambler GR

    更新日期:2014-04-01 00:00:00

  • Perioperative Characteristics of the Accuracy of Subcutaneous Continuous Glucose Monitoring: Pilot Study in Neurosurgery and Cardiac Surgery.

    abstract:BACKGROUND:The aim of this study was to elucidate the characteristics of accuracy of subcutaneous continuous glucose monitoring (SCGM) in the perioperative period for neurosurgical and cardiac surgery patients. METHODS:Forty-five subjects, including healthy volunteers (n = 15), neurosurgical patients (n = 15), and car...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0140

    authors: Sugiyama Y,Wakabayashi R,Urasawa M,Maruyama Y,Shimizu S,Kawamata M

    更新日期:2018-10-01 00:00:00

  • Factors Affecting Recruitment of Participants for Studies of Diabetes Technology in Newly Diagnosed Youth with Type 1 Diabetes: A Qualitative Focus Group Study with Parents and Children.

    abstract:BACKGROUND:Relatively little is known about parents' or children's attitudes toward recruitment for, and participation in, studies of new diabetes technologies immediately after diagnosis. This study investigated factors affecting recruitment of participants for studies in newly diagnosed youth with type 1 diabetes. M...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2016.0157

    authors: Farrington C,Allen J,Tauschmann M,Randell T,Trevelyan N,Hovorka R

    更新日期:2016-09-01 00:00:00

  • Differences in exhaled gas profiles between patients with type 2 diabetes and healthy controls.

    abstract:AIMS:Recent advances in analytical technology allow the detection of several hundred volatile organic compounds (VOCs) in human exhaled air, many of which reflect unidentified endogenous pathways. This study was performed to determine whether a breath gas analysis using proton transfer reaction-mass spectrometry (PTR-M...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2009.0181

    authors: Greiter MB,Keck L,Siegmund T,Hoeschen C,Oeh U,Paretzke HG

    更新日期:2010-06-01 00:00:00

  • An intelligent diabetes software prototype: predicting blood glucose levels and recommending regimen changes.

    abstract::Maintaining optimal blood glucose (BG) control is difficult for type 1 diabetes mellitus (T1DM) patients when typical daily regimens of food, insulin and exercise are altered. Artificial intelligence (AI) systems consisting of treatment algorithms calibrated through large datasets of patient specific information may o...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/15209150050501989

    authors: Otto E,Semotok C,Andrysek J,Basir O

    更新日期:2000-01-01 00:00:00

  • Effects of sleep apnea severity on glycemic control in patients with type 2 diabetes prior to continuous positive airway pressure treatment.

    abstract:BACKGROUND:Obstructive sleep apnea (OSA), a highly prevalent condition, is independently associated with increased risks of developing type 2 diabetes mellitus (T2D) and metabolic syndrome. It is unclear, however, if the severity of OSA has any impact on glycemic control among patients with T2D. We therefore aimed to d...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2011.0005

    authors: Pillai A,Warren G,Gunathilake W,Idris I

    更新日期:2011-09-01 00:00:00

  • Safety of drugs commonly used to treat hypertension, dyslipidemia, and Type 2 diabetes (the metabolic syndrome): part 2.

    abstract::It is becoming increasingly acknowledged that people with Type 2 Diabetes represent what can be termed "an enriched population": a group that has the greatest risk of morbidity and mortality from cardiovascular diseases such as myocardial infarcts and strokes. Due to the tremendous toll, both human and financial, that...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/15209150050025258

    authors: Marcus AO

    更新日期:2000-07-01 00:00:00

  • Wear and biomechanical characteristics of a novel shear-reducing insole with implications for high-risk persons with diabetes.

    abstract:OBJECTIVE:This study was designed to measure pressure and shear reduction of a novel insole design. METHODS:We compared three multilayer viscoelastic insoles to a novel insole design (Glide-Soft, Xilas Medical, Inc., San Antonio, TX). The bottom pad of each insole was fabricated from firm-density Plastazote [Apex Foot...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2005.7.638

    authors: Lavery LA,Lanctot DR,Constantinides G,Zamorano RG,Athanasiou KA,Agrawal CM

    更新日期:2005-08-01 00:00:00

  • Lasers and diabetic retinopathy: the art of gentle destruction.

    abstract::Laser retinal photocoagulation represents the primary therapy for the potentially blinding manifestations of diabetic retinopathy. Advances in laser therapy for diabetic eye disease have arisen from the convergence of laser technology and clinical ophthalmology. In this review, the basis of laser therapy in diabetic r...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/152091599317396

    authors: Petrovic V,Bhisitkul RB

    更新日期:1999-07-01 00:00:00

  • The association of serum vascular endothelial growth factor and ferritin in diabetic microvascular disease.

    abstract:BACKGROUND:Vascular endothelial growth factor (VEGF) is involved in the pathogenesis of diabetic microvascular disease. Most diabetes patients have higher serum levels of ferritin that may participate in diabetic vascular complications through high oxidative stress induced by iron. However, the mechanistic link between...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2013.0181

    authors: Guo L,Jiang F,Tang YT,Si MY,Jiao XY

    更新日期:2014-04-01 00:00:00

  • Minimization of Hypoglycemia as an Adverse Event During Insulin Infusion: Further Refinement of the Yale Protocol.

    abstract:BACKGROUND:The management of hyperglycemia in the intensive care unit has been a controversial topic for more than a decade, with target ranges varying from 80-110 mg/dL to <200 mg/dL. Multiple insulin infusion protocols exist, including several computerized protocols, which have attempted to achieve these targets. Imp...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2016.0101

    authors: Marvin MR,Inzucchi SE,Besterman BJ

    更新日期:2016-08-01 00:00:00

  • The association of self-monitoring of blood glucose use with medication adherence and glycemic control in patients with type 2 diabetes initiating non-insulin treatment.

    abstract:BACKGROUND:The value of self-monitoring of blood glucose (SMBG) for persons with type 2 diabetes who do not use insulin remains controversial. This observational study compares the likelihood of medication adherence and change in glycated hemoglobin (A1C) for non-insulin-using patients using SMBG versus those not using...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2012.0047

    authors: Virdi N,Daskiran M,Nigam S,Kozma C,Raja P

    更新日期:2012-09-01 00:00:00

  • Development of a Collaborative Algorithm for the Management of Type 2 Diabetes during Ramadan: An Anchor on Empowerment.

    abstract::Empowerment plays significant roles in the complex management of type 2 diabetes. International guidelines have provided recommendations on management of Muslims who fast during Ramadan. However, there remains a lack of patient-centered epistemic tool to empower healthcare providers and patients in managing diabetes d...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2018.0159

    authors: Lum ZK,See Toh WY,Lim SM,Rusli KDB,Abdul Shakoor SAKK,Tsou KYK,Chew DEK,Dalan R,Kwek SC,Othman N,Lian JX,Lee JY

    更新日期:2018-10-01 00:00:00

  • Nocturnal continuous glucose monitoring: accuracy and reliability of hypoglycemia detection in patients with type 1 diabetes at high risk of severe hypoglycemia.

    abstract:BACKGROUND:A reliable method to detect biochemical nocturnal hypoglycemia is highly needed, especially in patients with recurrent severe hypoglycemia. We evaluated reliability of nocturnal continuous glucose monitoring (CGM) in patients with type 1 diabetes at high risk of severe hypoglycemia. PATIENTS AND METHODS:Sev...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1089/dia.2013.0004

    authors: Bay C,Kristensen PL,Pedersen-Bjergaard U,Tarnow L,Thorsteinsson B

    更新日期:2013-05-01 00:00:00

  • Active assistance technology reduces glycosylated hemoglobin and weight in individuals with type 2 diabetes: results of a theory-based randomized trial.

    abstract:BACKGROUND:Type 2 diabetes is an individual health challenge requiring ongoing self-management. Remote patient reporting of relevant health parameters and linked automated feedback via mobile telephone have potential to strengthen self-management and improve outcomes. This research involved development and evaluation o...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2013.0056

    authors: Orsama AL,Lähteenmäki J,Harno K,Kulju M,Wintergerst E,Schachner H,Stenger P,Leppänen J,Kaijanranta H,Salaspuro V,Fisher WA

    更新日期:2013-08-01 00:00:00

  • Diabetes registries: where we are and where are we headed?

    abstract::Disease registries are a searchable list of all patients with a particular chronic condition that often interface with an electronic medical record. The well-designed registry links all members of the patient's health team and provides key information for patients and physicians. The critical impact of a registry is t...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2008.0057

    authors: Khan L,Mincemoyer S,Gabbay RA

    更新日期:2009-04-01 00:00:00

  • Determining clinical and psychological benefits and barriers with continuous glucose monitoring therapy.

    abstract:BACKGROUND:Preventing the complications of diabetes requires tight control and minimizing blood glucose fluctuation. Pursuing these goals increases the risk of severe hypoglycemia. The authors hoped to identify if using continuous glucose monitoring (CGM) decreased the incidence of severe hypoglycemia, resulted in less...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2009.0121

    authors: Halford J,Harris C

    更新日期:2010-03-01 00:00:00

  • Minimally invasive insulin delivery in subjects with type 1 diabetes using hollow microneedles.

    abstract:BACKGROUND:Microneedles have previously been used to deliver insulin to animal models, but not in human subjects. This study tested the hypothesis that hollow microneedles can deliver insulin to modulate blood glucose levels in subjects with type 1 diabetes in a minimally invasive manner. METHODS:This study was carrie...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2008.0103

    authors: Gupta J,Felner EI,Prausnitz MR

    更新日期:2009-06-01 00:00:00

  • Glycemic Variability Is Associated with Frequency of Blood Glucose Testing and Bolus: Post Hoc Analysis Results from the ProAct Study.

    abstract:INTRODUCTION:The ProAct study has shown that a pump switch to the Accu-Chek(®) Combo system (Roche Diagnostics Deutschland GmbH, Mannheim, Germany) in type 1 diabetes patients results in stable glycemic control with significant improvements in glycated hemoglobin (HbA1c) in patients with unsatisfactory baseline HbA1c a...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1089/dia.2014.0278

    authors: Pfützner A,Weissmann J,Mougiakakou S,Daskalaki E,Weis N,Ziegler R

    更新日期:2015-06-01 00:00:00

  • Patient perceptions of using the OmniPod system compared with conventional insulin pumps in young adults with type 1 diabetes.

    abstract:AIMS:This study evaluated treatment satisfaction, comfort, and function using the wireless OmniPod™ Insulin Management System (Insulet Corp., Bedford, MA) compared with conventional (infusion set) insulin pumps in young adults with type 1 diabetes. RESEARCH DESIGN AND METHODS:Twenty-nine patients (age, 24.0 ± 5.1 year...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2011.0228

    authors: Lebenthal Y,Lazar L,Benzaquen H,Shalitin S,Phillip M

    更新日期:2012-05-01 00:00:00

  • Clinical studies on chromium picolinate supplementation in diabetes mellitus--a review.

    abstract::Chromium (Cr) picolinate (CrPic) is a widely used nutritional supplement for optimal insulin function. A relationship among Cr status, diabetes, and associated pathologies has been established. Virtually all trials using CrPic supplementation for subjects with diabetes have demonstrated beneficial effects. Thirteen of...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2006.8.677

    authors: Broadhurst CL,Domenico P

    更新日期:2006-12-01 00:00:00

  • Evaluating the accuracy, reliability, and clinical applicability of continuous glucose monitoring (CGM): Is CGM ready for real time?

    abstract:BACKGROUND:This study was designed to assess the accuracy, reliability, and contribution to clinical decision-making of two commercially available continuous glucose monitoring (CGM) devices using a novel analytical approach. STUDY DESIGN:Eleven individuals with type 1 diabetes and five with type 2 diabetes wore a Gua...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2008.0041

    authors: Mazze RS,Strock E,Borgman S,Wesley D,Stout P,Racchini J

    更新日期:2009-01-01 00:00:00

  • Fluorescein kinetics in interstitial fluid harvested from diabetic skin during fluorescein angiography: implications for glucose monitoring.

    abstract:BACKGROUND:Glucose monitoring based on sampling skin interstitial fluid (ISF) is being developed as an alternative to fingerstick blood glucose monitoring. Time delays between rapidly changing levels of glucose in blood and interstitial fluid have been reported in the literature to be between 5 and 20 minutes. This stu...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/152091599317530

    authors: Smith A,Yang D,Delcher H,Eppstein J,Williams D,Wilkes S

    更新日期:1999-04-01 00:00:00

  • Nocturnal Glucose Metabolism in Type 1 Diabetes: A Study Comparing Single Versus Dual Tracer Approaches.

    abstract:BACKGROUND:Understanding the effect size, variability, and underlying physiology of the dawn phenomenon is important for next-generation closed-loop control algorithms for type 1 diabetes (T1D). SUBJECTS AND METHODS:We used an iterative protocol design to study 16 subjects with T1D on individualized insulin pump thera...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2015.0011

    authors: Mallad A,Hinshaw L,Dalla Man C,Cobelli C,Basu R,Lingineni R,Carter RE,Kudva YC,Basu A

    更新日期:2015-08-01 00:00:00

  • Patient-reported outcomes in adults with type 2 diabetes using mealtime inhaled technosphere insulin and basal insulin versus premixed insulin.

    abstract:AIMS:This study assessed patient-reported outcomes in a multicenter study of adults with type 2 diabetes taking mealtime Technosphere(®) inhaled insulin (MannKind Corp., Valencia, CA) and basal insulin (insulin glargine) or premixed aspart insulin 70/30. METHODS:Subjects were 618 non-smoking adults with starting hemog...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1089/dia.2011.0037

    authors: Peyrot M,Rubin RR

    更新日期:2011-12-01 00:00:00

  • Continuous glucose monitoring reveals delayed nocturnal hypoglycemia after intermittent high-intensity exercise in nontrained patients with type 1 diabetes.

    abstract:OBJECTIVE:Exercise is a cornerstone of diabetes therapy in type 1 diabetes mellitus (DMT1) patients. The type of exercise is important in determining the propensity to hypoglycemia. We assessed, by continuous glucose monitoring (CGM), the glucose profiles during and in the following 20h after a session of two different...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1089/dia.2010.0038

    authors: Maran A,Pavan P,Bonsembiante B,Brugin E,Ermolao A,Avogaro A,Zaccaria M

    更新日期:2010-10-01 00:00:00

  • A Real-World Prospective Study of the Safety and Effectiveness of the Loop Open Source Automated Insulin Delivery System.

    abstract:OBJECTIVE:To evaluate the safety and effectiveness of the Loop Do-It-Yourself (DIY) automated insulin delivery system. RESEARCH DESIGN AND METHODS:A prospective real-world observational study was conducted, which included 558 adults and children (age range 1 to 71 years, mean HbA1c 6.8±1.0%) who initiated Loop either ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2020.0535

    authors: Lum J,Bailey R,Barnes-Lomen V,Naranjo D,Hood K,Lal RA,Arbiter B,Brown A,DeSalvo DJ,Pettus J,Calhoun P,Beck RW

    更新日期:2020-11-23 00:00:00