Abstract:
:Background Glycated hemoglobin A1c (HbA1c) is a key biomarker in the glycemic management of individuals with diabetes but the relationship with glucose levels can be variable. A recent kinetic model has described a calculated HbA1c (cHbA1c) that is individual-specific. Our aim was to validate the routine clinical use of this glucose metric in younger individuals with diabetes under real life-settings. Materials and methods We retrieved HbA1c and glucose data from the German-Austrian-Swiss-Luxemburgian diabetes follow-up (DPV) registry, which covers pediatric individuals with type 1 diabetes. The new glycemic measure, cHbA1c, uses two individual parameters identified by data sections which contain continuous glucose data between two laboratory HbA1c measurements. The cHbA1c was prospectively validated using longitudinal HbA1c data. Results CGM data from 352 T1D individuals in 13 clinics were analyzed together with HbA1c that ranged between 4.9-10.6%. In the prospective analysis, absolute deviations of estimated HbA1c (eHbA1c), glucose management indicator (GMI) and cHbA1c compared with laboratory HbA1c were [median (IQR)]: 1.01 (0.50, 1.75), 0.46 (0.21, 084) and 0.26 (0.12, 0.46), giving an average bias of 0.6, 0.4 and 0.0, respectively in NGSP % unit. For eHbA1c and GMI, only 25% and 54% of subjects were within ±0.5% of laboratory HbA1c values, while 82% of cHbA1c were within ±0.5% of laboratory HbA1c results. Conclusions Our data show the superior performance of cHbA1c compared with eHbA1c and GMI at reflecting laboratory HbA1c. These data indicate that cHbA1c can be potentially used instead in laboratory HbA1c, at least in younger individuals with T1D.
journal_name
Diabetes Technol Therjournal_title
Diabetes technology & therapeuticsauthors
Xu Y,Grimsmann JM,Karges B,Hofer SE,Danne T,Holl RW,Ajjan RA,Dunn TDdoi
10.1089/dia.2020.0553subject
Has Abstractpub_date
2021-01-04 00:00:00eissn
1520-9156issn
1557-8593pub_type
杂志文章abstract:BACKGROUND:Lipohypertrophy (LH) is a complication of insulin therapy. We assessed LH prevalence, risk factors, insulin usage, and clinical and health economic effects in China. METHODS:In four cities, 401 adult patients injecting insulin ≥1 year were surveyed for diabetes/insulin injection history and practices, pen n...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2016.0334
更新日期:2017-01-01 00:00:00
abstract::Chronic hyperglycemia, as assessed by hemoglobin A1c (HbA1c) levels, has been associated with the development of microvascular and macrovascular complications of diabetes. Several studies have shown that acute hyperglycemia can add to the effect of chronic hyperglycemia in inducing tissue damage. Acute hyperglycemia c...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2010.0146
更新日期:2011-03-01 00:00:00
abstract::Existing standards of the management of the diabetic patients are not efficient enough, and further improvement is needed. The major objective of this paper is to present and discuss the therapeutic effectiveness of an intensive care telematic system designed and applied for intensive treatment of pregnant type 1 diab...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章
doi:10.1089/15209150152811207
更新日期:2001-01-01 00:00:00
abstract::There is a clear role for inflammation in the development of type 2 diabetes and its associated co-morbidities. Circulating inflammatory markers such as C-reactive protein, sialic acid, and interleukin- 6 are all significant independent predictors of disease. A number of nutritional components are hypothesized to modu...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2006.8.45
更新日期:2006-02-01 00:00:00
abstract:BACKGROUND:For patients with diabetes, the quality of outpatient glycemic control is readily assessed by hemoglobin A1c. In contrast, standardized measures for assessing the quality of blood glucose (BG) management in hospitalized patients are lacking. Because of recent studies demonstrating the benefits of strict glyc...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2006.8.560
更新日期:2006-10-01 00:00:00
abstract:OBJECTIVE:We sought to cross validate several metrics for quality of glycemic control, hypoglycemia, and hyperglycemia. RESEARCH DESIGN AND METHODS:We analyzed the mathematical properties of several metrics for overall glycemic control, and for hypo- and hyperglycemia, to evaluate their similarities, differences, and ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2017.0416
更新日期:2018-05-01 00:00:00
abstract:BACKGROUND:During the proteomic era, one of the most rapidly growing areas in biomedical research is biomarker discovery, particularly using proteomic technologies. The urinary proteome is known to be a valuable field of study and has become one of the most attractive subdisciplines in clinical proteomics for human dis...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2010.0078
更新日期:2010-12-01 00:00:00
abstract:OBJECTIVES:We evaluated patterns of meal intake, insulin bolus delivery, and fingerstick glucose measurements during hybrid closed-loop and sensor-augmented pump (SAP) therapy, including associations with glucose control. METHODS:Data were retrospectively analyzed from pump-treated adults with type 1 diabetes who unde...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2016.0307
更新日期:2017-07-01 00:00:00
abstract:OBJECTIVE:Over the past 35 years considerable research has been performed toward the investigation of noninvasive and minimally invasive glucose monitoring techniques. Optical polarimetry is one noninvasive technique that has shown promise as a means to ascertain blood glucose levels through measuring the glucose conce...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2012.0070
更新日期:2012-09-01 00:00:00
abstract:BACKGROUND:There are currently few data available on the long-term use of continuous subcutaneous insulin infusion (CSII) (insulin pump) therapy in children. METHODS:Charts from 291 youth with type 1 diabetes (T1D) who were treated with CSII therapy for at least 1 year were reviewed. Data analysis included hemoglobin ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2007.0214
更新日期:2007-10-01 00:00:00
abstract:OBJECTIVE:This study assessed the accuracy and reliability of three continuous glucose monitoring (CGM) systems. RESEARCH DESIGN AND METHODS:We studied the Animas® (West Chester, PA) Vibe™ with Dexcom® (San Diego, CA) G4™ version A sensor (G4A), the Abbott Diabetes Care (Alameda, CA) Freestyle® Navigator I (NAV), and ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1089/dia.2013.0049
更新日期:2013-08-01 00:00:00
abstract:BACKGROUND:Recent evidence emphasizes the importance of maintaining normoglycemia in critically ill patients to reduce morbidity and mortality. Different analytical methods of varying accuracy exist for obtaining and measuring blood glucose in critically ill patients. The purpose of this study was to determine if there...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2008.0263
更新日期:2008-06-01 00:00:00
abstract::Subcutaneous (s.c.) injections of identical insulin doses may lead to considerable intra- and inter-individual differences in the current metabolic control of patients with diabetes mellitus. This well-known variability of the metabolic effect of insulin hampers practical insulin therapy considerably. The aim of this ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/152091502320798312
更新日期:2002-01-01 00:00:00
abstract:BACKGROUND:Continuous subcutaneous insulin infusion (CSII) is an effective method of insulin substitution with increased risk of hypoglycemia and diabetic ketoacidosis (DKA) in rare situations. The lack of subcutaneous long-acting insulin and short half-life of serum insulin increases the risk of ketosis and DKA follow...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2008.0124
更新日期:2009-08-01 00:00:00
abstract::This study was designed to determine plasma glucose and insulin levels after administration of three escalating doses of the oral insulin product hexyl-insulin monoconjugate 2 (HIM2) in fasting, insulin-deprived adult patients with type 1 diabetes. The study was also designed to assess the safety of the product. Sixte...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/152091502760306544
更新日期:2002-01-01 00:00:00
abstract:BACKGROUND:The quantitative analysis of glucose time-series can greatly help the management of diabetes. In particular, a static nonlinear transformation, which symmetrizes the distribution of glucose levels by bringing them in the so-called risk space, was proposed previously for both self-monitoring blood glucose and...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2011.0006
更新日期:2011-08-01 00:00:00
abstract:BACKGROUND:As healthy diet and physical activity can improve glucometabolic control in patients with type 2 diabetes, lifestyle changes should be the basis for each therapy. The only tool to visualize immediate effects of food pattern and exercise on blood glucose levels is self-monitoring of blood glucose (SMBG). Ther...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2010.0008
更新日期:2010-07-01 00:00:00
abstract:BACKGROUND:Continuous glucose monitoring (CGM) and sensor-augmented pump (SAP) therapy improve glucose control provided good adherence. In France, not only diabetologists, nurses, and dieticians but also nurses employed by homecare providers (HCPNs) are together involved in the initiation and/or follow-up of continuous...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究
doi:10.1089/dia.2015.0240
更新日期:2016-03-01 00:00:00
abstract::This paper presents a critical review of continuous glucose monitoring studies that address accuracy, utility in assessing glucose variability, detection of hypoglycemia for improved metabolic control or reduced glucose variability, impact on quality of life, reduced fear of hypoglycemia, and applicability in helping ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2007.0261
更新日期:2008-04-01 00:00:00
abstract:BACKGROUND:The hyperinsulinemic euglycemic clamp is the gold standard for assessment of insulin resistance and requires frequent, accurate measurements of blood glucose concentrations, typically utilizing the YSI 2300 STAT Plus™ glucose analyzer (YSI, Inc., Yellow Springs, OH). Despite its accuracy, the YSI has several...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2013.0288
更新日期:2014-05-01 00:00:00
abstract:: Background: The objective of this study was to assess the safety and performance of the Omnipod® personalized model predictive control (MPC) algorithm in adults, adolescents, and children aged ≥6 years with type 1 diabetes (T1D) under free-living conditions using an invest...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章,多中心研究
doi:10.1089/dia.2019.0286
更新日期:2020-03-01 00:00:00
abstract:BACKGROUND:Automated insulin management features of the MiniMed® 640G sensor-augmented pump system include suspension in response to predicted low sensor glucose (SG) values ("suspend before low"), suspension in response to existing low SG values ("suspend on low"), and automatic restarting of basal insulin delivery up...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2016.0216
更新日期:2016-10-01 00:00:00
abstract:BACKGROUND:The recent availability of a continuous glucose monitor offers the opportunity to match the demands of intensive diabetes management with a period of equally intensive blood glucose monitoring. The present study evaluates the performance of the MiniMed continuous glucose monitoring system (CGMS) in patients ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/152091500316737
更新日期:2000-04-01 00:00:00
abstract::Empowerment plays significant roles in the complex management of type 2 diabetes. International guidelines have provided recommendations on management of Muslims who fast during Ramadan. However, there remains a lack of patient-centered epistemic tool to empower healthcare providers and patients in managing diabetes d...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2018.0159
更新日期:2018-10-01 00:00:00
abstract:BACKGROUND:The purpose of this study is to test the agreement between energy expenditure estimate of the SenseWear(®) Armband Pro3 (SWA) (BodyMedia, Pittsburgh, PA) and the Omron HJ-720 (Omron Healthcare, Kyoto, Japan) step counter with indirect calorimetry (IC) as a gold standard in older individuals with type 1 and t...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2012.0235
更新日期:2013-05-01 00:00:00
abstract:BACKGROUND:Continuous glucose monitoring (CGM) has been shown to improve glycemic control and reduce hypoglycemia with consistent use. Youth, however, are unlikely to use CGM consistently. We compared psychological characteristics of youth with type 1 diabetes, their parents, and adults with type 1 diabetes randomized ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2011.0201
更新日期:2012-06-01 00:00:00
abstract::The peroxisome proliferator-activated receptors (PPARs) are a group of nuclear receptor isoforms, including PPARgamma, PPARalpha, and PPARdelta, encoded by different genes. PPARs are ligand-regulated transcription factors that control gene expression by binding to specific response elements (PPREs) within promoters. P...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/15209150260007381
更新日期:2002-01-01 00:00:00
abstract::By the year 2030, the diabetes pandemic will likely affect more than 10% of the world's population. The personal, public health, and economic crises implicit in this trend call for decisive action. Yet, escalating dilemmas thwart full realization of current therapies. First, controversial studies, such as the Action t...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2012.0132
更新日期:2012-11-01 00:00:00
abstract:BACKGROUND:We assessed the impact of using an automated bolus advisor integrated into a blood glucose meter on the timing and frequency of adjusting insulin therapy parameter settings and whether the availability of this technology would increase blood glucose test strip utilization in diabetes patients treated with mu...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1089/dia.2013.0280
更新日期:2014-05-01 00:00:00
abstract:BACKGROUND:Continuous glucose monitoring (CGM) has been shown to be a valuable tool to improve glycemic control in patients with diabetes. The objective of this pilot study was to develop and implement CGM in an existing diabetes clinic for low-income patients on multiple daily injections. SUBJECTS AND METHODS:This wa...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2013.0072
更新日期:2013-10-01 00:00:00