Abstract:
BACKGROUND:Continuous subcutaneous insulin infusion (CSII) is an effective method of insulin substitution with increased risk of hypoglycemia and diabetic ketoacidosis (DKA) in rare situations. The lack of subcutaneous long-acting insulin and short half-life of serum insulin increases the risk of ketosis and DKA following CSII failure. We evaluated the metabolic effects of CSII with and without daily supplemental long-acting insulin glargine in a group of young children switched to CSII from multiple daily insulin (premeal aspart + glargine) to either CSII plus daily glargine (CSII + G) or CSII therapy. METHODS:From retrospective clinic data, self-monitored blood glucose (SMBG), hemoglobin A1c (HbA(1c)), hypoglycemic episodes, and body mass index (BMI) were obtained from 12 patients (five girls, seven boys; 7.7 +/- 1.8 years) on CSII + G and 12 age- and gender-matched patients (five girls, seven boys; 7.7 +/- 2.1 years) on CSII with similar baseline HbA(1c) and BMI were reviewed over a 1.0-year period. RESULTS:The insulin glargine dose in the CSII + G group was 30.6 +/- 12.4% (range, 13.9-53.3%) of daily basal insulin dose. Both groups had similar total daily insulin and bolus:basal insulin at baseline and at 1.0 year. Glycemic control improved in the CSII + G (SMBG, 195.5 +/- 47.3 vs. 156.8 +/- 36.8 mg/dL, P < 0.05; HbA(1c), 8.1 +/- 0.9% vs. 7.4 +/- 0.4%, P < 0.02) and CSII (SMBG, 198.7 +/- 45.7 vs. 161.4 +/- 30.9 mg/dL, P < 0.05; HbA(1c), 8.2 +/- 0.4% vs. 7.7 +/- 0.5%, P < 0.01) groups without significant changes in hypoglycemic episodes and BMI. There were no DKA episodes despite three emergency room visits for hyperglycemia and ketosis due to catheter dislodgement only in the CSII group. CONCLUSIONS:CSII therapy with or without daily insulin glargine improved glycemic control without changes in the rate of hypoglycemia and DKA, suggesting that this treatment regimen is feasible and may also prevent development of hyperglycemia and ketosis or even DKA.
journal_name
Diabetes Technol Therjournal_title
Diabetes technology & therapeuticsauthors
Alemzadeh R,Parton EA,Holzum MKdoi
10.1089/dia.2008.0124subject
Has Abstractpub_date
2009-08-01 00:00:00pages
481-6issue
8eissn
1520-9156issn
1557-8593journal_volume
11pub_type
杂志文章abstract:BACKGROUND:SAR342434 is a biosimilar follow-on of insulin lispro-Humalog®. This study aimed to show similar efficacy, safety, and immunogenicity of SAR342434 (SAR-Lis) versus insulin lispro-Humalog (Ly-Lis) in adult patients with type 1 diabetes (T1DM) treated with multiple daily injections while using basal insulin gl...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1089/dia.2017.0117
更新日期:2017-09-01 00:00:00
abstract:PURPOSE:This study investigated reasons for the rejection and discontinuation of insulin pump therapy and explored general attitudes towards this mode of therapy among young patients with type 1 diabetes. METHODS:A questionnaire was developed using a focus group of young people with diabetes. It was then used to surve...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2009.0080
更新日期:2010-01-01 00:00:00
abstract:BACKGROUND:Stress-induced hyperglycemia is prevalent in critical care, even in patients with no history of diabetes. Increased counter-regulatory hormone response increases gluconeogenesis and effective insulin resistance, which can be exacerbated by drug therapy. Control of blood glucose levels to the 4.0-6.1 mmol/L r...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2006.8.449
更新日期:2006-08-01 00:00:00
abstract:BACKGROUND:The aim of this investigation was to assess clinical predictors of the glycosylated hemoglobin (HbA1C) response after the addition of a thiazolidinedione (TZD) to a biguanide, a sulfonylurea, or both in subjects with type 2 diabetes. METHODS:Chart review (n = 68 physicians) was used to identify consecutive ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2007.0248
更新日期:2007-12-01 00:00:00
abstract::This paper presents a critical review of continuous glucose monitoring studies that address accuracy, utility in assessing glucose variability, detection of hypoglycemia for improved metabolic control or reduced glucose variability, impact on quality of life, reduced fear of hypoglycemia, and applicability in helping ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2007.0261
更新日期:2008-04-01 00:00:00
abstract:BACKGROUND:Continuous glucose monitoring (CGM) provides glucose trend information that can be used to guide treatment and motivate patients with diabetes. Currently, the evidence on effectiveness of CGM in patients with type 2 diabetes is debatable. We aim to provide a systematic review and meta-analysis to synthesize ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,meta分析
doi:10.1089/dia.2018.0177
更新日期:2018-09-01 00:00:00
abstract:BACKGROUND:There are currently few data available on the long-term use of continuous subcutaneous insulin infusion (CSII) (insulin pump) therapy in children. METHODS:Charts from 291 youth with type 1 diabetes (T1D) who were treated with CSII therapy for at least 1 year were reviewed. Data analysis included hemoglobin ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2007.0214
更新日期:2007-10-01 00:00:00
abstract:BACKGROUND:Programmable and fixed auditory and/or vibratory threshold alerts are essential features of real-time continuous glucose monitoring (rtCGM) systems that provide users time to intervene before the onset of clinical hypoglycemia or hyperglycemia. A sixth-generation rtCGM system from Dexcom, Inc. (G6) includes ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2018.0359
更新日期:2019-04-01 00:00:00
abstract:BACKGROUND:The junction of telemedicine home monitoring with multifaceted disease management programs seems nowadays a promising direction to combine the need for an intensive approach to deal with diabetes and the pressure to contain the costs of the interventions. Several projects in the European Union and the United...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2004.6.567
更新日期:2004-10-01 00:00:00
abstract:BACKGROUND:Patients undergoing intensive insulin therapy may have blood glucose (BG) samples drawn from arterial, capillary, or venous sources. This study compared capillary and venous BG across a range of glucose concentrations and under conditions of rapid change in BG. METHODS:Following a 10-h fast, 40 adult patien...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章
doi:10.1089/dia.2009.0023
更新日期:2009-10-01 00:00:00
abstract:BACKGROUND:The Optimizing Control in Diabetes (OPTIMIZE) survey was conducted to understand the patients' perspective to achieving good glycemic control and to determine how patients' perceptions of insulin may affect their decisions to initiate or intensify their insulin therapy. METHODS:A total of 1,444 subjects wit...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究
doi:10.1089/dia.2008.0249
更新日期:2008-02-01 00:00:00
abstract::Continuous glucose monitoring (CGM) systems have been available for more than 15 years by now. However, market uptake is relatively low in most countries; in other words, relatively few patients with diabetes use CGM systems regularly. One major reason for the reluctance of patients to use CGM systems is the costs ass...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2015.0296
更新日期:2016-02-01 00:00:00
abstract:BACKGROUND:The efficacy of short-term professional continuous glucose monitoring (CGM) for glycemic control in patients with diabetes remains unclear. METHODS:We performed a 3-month study to evaluate the benefits of CGM in 64 patients. RESULTS:The overall glycemic control of patients who underwent CGM improved signif...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2018.0164
更新日期:2018-09-01 00:00:00
abstract:BACKGROUND:This study was designed to assess the accuracy, reliability, and contribution to clinical decision-making of two commercially available continuous glucose monitoring (CGM) devices using a novel analytical approach. STUDY DESIGN:Eleven individuals with type 1 diabetes and five with type 2 diabetes wore a Gua...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2008.0041
更新日期:2009-01-01 00:00:00
abstract:BACKGROUND:Type 2 diabetes is an individual health challenge requiring ongoing self-management. Remote patient reporting of relevant health parameters and linked automated feedback via mobile telephone have potential to strengthen self-management and improve outcomes. This research involved development and evaluation o...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2013.0056
更新日期:2013-08-01 00:00:00
abstract:BACKGROUND:Accurate and economic detection of nerve damage in diabetes is key to more widespread diagnosis of patients with diabetic peripheral neuropathy (DPN) and painful diabetic neuropathy. This study examined the diagnostic performance of NerveCheck, an inexpensive ($500) quantitative sensory testing (QST) device....
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2016.0279
更新日期:2016-12-01 00:00:00
abstract::Self-monitoring of blood glucose (SMBG) is universally considered to be an integral part of type 1 diabetes management and crucial for optimizing the safety and efficacy of complex insulin regimens. This extends to type 2 diabetes patients on intensive insulin therapy, and there is also a growing body of evidence sugg...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2013.0302
更新日期:2014-07-01 00:00:00
abstract::The foreign body capsule that forms around implanted devices such as glucose sensors is hypovascular and has limited permeability to glucose. Such a capsule may function better if well vascularized. We hypothesized that capsular vascularization achieved by local release of vascular endothelial growth factor (VEGF) wou...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/152091504773731320
更新日期:2004-04-01 00:00:00
abstract:OBJECTIVES:Hyperglycemia is a prominent feature among patients exposed to major stress such as in cardiac surgery. The implementation of a continuous glucose monitoring system (CGMS) for glucose monitoring during cardiac surgery was assessed. SUBJECTS AND METHODS:Fifty-nine consecutive patients who underwent cardiac s...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2011.0154
更新日期:2012-03-01 00:00:00
abstract:AIM:Insulin therapy induces remission in subjects with newly diagnosed type 2 diabetes mellitus (T2DM). This study assessed the insulin and C-peptide levels in newly diagnosed T2DM subjects during low-dose insulin therapy. SUBJECTS AND METHODS:Twenty newly diagnosed, drug-naive, T2DM patients without acute or chronic ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2010.0187
更新日期:2011-04-01 00:00:00
abstract:OBJECTIVE:This study assessed the association of serum adiponectin with carotid intimal medial thickness (IMT) in Asian Indians with different grades of glucose intolerance. METHODS:Subjects with normal glucose tolerance (NGT) (n = 520), impaired glucose tolerance (IGT) (n = 115), and type 2 diabetes mellitus (T2DM) (...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2009.0100
更新日期:2010-02-01 00:00:00
abstract:BACKGROUND:Lipoprotein-associated phospholipase A₂ (Lp-PLA₂) is a lipoprotein-associated enzyme that cleaves oxidized phosphatidylcholines, generating pro-atherosclerotic lysophosphatidylcholine and oxidized free fatty acids. Lp-PLA₂ is independently associated with cardiovascular disease (CVD) in a variety of populati...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2010.0175
更新日期:2011-03-01 00:00:00
abstract::Clustering of diseases has been appreciated by health insurers and epidemiologists for some time. Co-morbidity suggests shared pathways of disease. It is by now well agreed that common diseases have a strong genetic component. Here we present evidence that the angiotensin I-converting enzyme (ACE) deletion/deletion (D...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/152091502320798321
更新日期:2002-01-01 00:00:00
abstract:BACKGROUND:The present study evaluated the efficacy of biphasic human insulin 30 (BHI 30) in type 2 diabetes patients who had failed in therapy with two or more oral antidiabetes drugs (OADs). METHODS:This open-label, nonrandomized, 4-month, multicenter, clinical observational study was conducted in Shanghai, China. A...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究
doi:10.1089/dia.2011.0168
更新日期:2012-03-01 00:00:00
abstract:OBJECTIVE:This study was designed to develop predictive formulas for precise insulin dosing in young children with type 1 diabetes (T1DM). RESEARCH DESIGN AND METHODS:Consecutive 1-year data from a group of 14 young patients (eight girls, six boys) 3.9 ± 0.8 years old with diabetes duration of 2.0 ± 0.8 years, transit...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2011.0184
更新日期:2012-05-01 00:00:00
abstract:BACKGROUND:The purpose of this study was to evaluate the performance of an insulin infusion protocol targeting a blood glucose (BG) level of 140-180 mg/dL and to characterize protocol adherence. MATERIALS AND METHODS:This was a retrospective observational cohort study including patients for whom the protocol was order...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2015.0046
更新日期:2016-02-01 00:00:00
abstract::Existing standards of the management of the diabetic patients are not efficient enough, and further improvement is needed. The major objective of this paper is to present and discuss the therapeutic effectiveness of an intensive care telematic system designed and applied for intensive treatment of pregnant type 1 diab...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章
doi:10.1089/15209150152811207
更新日期:2001-01-01 00:00:00
abstract::Innovo (Novo Nordisk A/S, Hillerød, Denmark) is a new insulin injection system that offers built-in memory and a large, clear display to provide patients with more control during insulin injections. The aim of this trial was to compare the efficacy and safety of Innovo and NovoPen 3 (Novo Nordisk A/S) in patients expe...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章,多中心研究,随机对照试验
doi:10.1089/152091504322783413
更新日期:2004-02-01 00:00:00
abstract:BACKGROUND:Performance of continuous glucose monitors (CGMs) may be lower when glucose levels are changing rapidly, such as occurs during physical activity. Our aim was to evaluate accuracy of a current-generation CGM during moderate-intensity exercise in type 1 diabetes (T1D) pregnancy. SUBJECTS AND METHODS:As part o...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2012.0292
更新日期:2013-03-01 00:00:00
abstract::Rates of diabetes are increasing worldwide and there is not a sufficient clinical workforce to care for these patients. Diabetes-related apps are a feasible way to provide diabetes education to large numbers of people with diabetes but attrition rates are high. Apps enhanced by virtual coaching may be a way to circumn...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2019.0016
更新日期:2019-06-01 00:00:00