Feasibility of continuous subcutaneous insulin infusion and daily supplemental insulin glargine injection in children with type 1 diabetes.

Abstract:

BACKGROUND:Continuous subcutaneous insulin infusion (CSII) is an effective method of insulin substitution with increased risk of hypoglycemia and diabetic ketoacidosis (DKA) in rare situations. The lack of subcutaneous long-acting insulin and short half-life of serum insulin increases the risk of ketosis and DKA following CSII failure. We evaluated the metabolic effects of CSII with and without daily supplemental long-acting insulin glargine in a group of young children switched to CSII from multiple daily insulin (premeal aspart + glargine) to either CSII plus daily glargine (CSII + G) or CSII therapy. METHODS:From retrospective clinic data, self-monitored blood glucose (SMBG), hemoglobin A1c (HbA(1c)), hypoglycemic episodes, and body mass index (BMI) were obtained from 12 patients (five girls, seven boys; 7.7 +/- 1.8 years) on CSII + G and 12 age- and gender-matched patients (five girls, seven boys; 7.7 +/- 2.1 years) on CSII with similar baseline HbA(1c) and BMI were reviewed over a 1.0-year period. RESULTS:The insulin glargine dose in the CSII + G group was 30.6 +/- 12.4% (range, 13.9-53.3%) of daily basal insulin dose. Both groups had similar total daily insulin and bolus:basal insulin at baseline and at 1.0 year. Glycemic control improved in the CSII + G (SMBG, 195.5 +/- 47.3 vs. 156.8 +/- 36.8 mg/dL, P < 0.05; HbA(1c), 8.1 +/- 0.9% vs. 7.4 +/- 0.4%, P < 0.02) and CSII (SMBG, 198.7 +/- 45.7 vs. 161.4 +/- 30.9 mg/dL, P < 0.05; HbA(1c), 8.2 +/- 0.4% vs. 7.7 +/- 0.5%, P < 0.01) groups without significant changes in hypoglycemic episodes and BMI. There were no DKA episodes despite three emergency room visits for hyperglycemia and ketosis due to catheter dislodgement only in the CSII group. CONCLUSIONS:CSII therapy with or without daily insulin glargine improved glycemic control without changes in the rate of hypoglycemia and DKA, suggesting that this treatment regimen is feasible and may also prevent development of hyperglycemia and ketosis or even DKA.

journal_name

Diabetes Technol Ther

authors

Alemzadeh R,Parton EA,Holzum MK

doi

10.1089/dia.2008.0124

subject

Has Abstract

pub_date

2009-08-01 00:00:00

pages

481-6

issue

8

eissn

1520-9156

issn

1557-8593

journal_volume

11

pub_type

杂志文章
  • Efficacy and Safety of Biosimilar SAR342434 Insulin Lispro in Adults with Type 1 Diabetes Also Using Insulin Glargine-SORELLA 1 Study.

    abstract:BACKGROUND:SAR342434 is a biosimilar follow-on of insulin lispro-Humalog®. This study aimed to show similar efficacy, safety, and immunogenicity of SAR342434 (SAR-Lis) versus insulin lispro-Humalog (Ly-Lis) in adult patients with type 1 diabetes (T1DM) treated with multiple daily injections while using basal insulin gl...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1089/dia.2017.0117

    authors: Garg SK,Wernicke-Panten K,Rojeski M,Pierre S,Kirchhein Y,Jedynasty K

    更新日期:2017-09-01 00:00:00

  • Attitudes towards insulin pump therapy among adolescents and young people.

    abstract:PURPOSE:This study investigated reasons for the rejection and discontinuation of insulin pump therapy and explored general attitudes towards this mode of therapy among young patients with type 1 diabetes. METHODS:A questionnaire was developed using a focus group of young people with diabetes. It was then used to surve...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2009.0080

    authors: Seereiner S,Neeser K,Weber C,Schreiber K,Habacher W,Rakovac I,Beck P,Schmidt L,Pieber TR

    更新日期:2010-01-01 00:00:00

  • A pilot study of the SPRINT protocol for tight glycemic control in critically Ill patients.

    abstract:BACKGROUND:Stress-induced hyperglycemia is prevalent in critical care, even in patients with no history of diabetes. Increased counter-regulatory hormone response increases gluconeogenesis and effective insulin resistance, which can be exacerbated by drug therapy. Control of blood glucose levels to the 4.0-6.1 mmol/L r...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2006.8.449

    authors: Lonergan T,Compte AL,Willacy M,Chase JG,Shaw GM,Hann CE,Lotz T,Lin J,Wong XW

    更新日期:2006-08-01 00:00:00

  • Clinical predictors of glycosylated hemoglobin response to thiazolidinedione therapy.

    abstract:BACKGROUND:The aim of this investigation was to assess clinical predictors of the glycosylated hemoglobin (HbA1C) response after the addition of a thiazolidinedione (TZD) to a biguanide, a sulfonylurea, or both in subjects with type 2 diabetes. METHODS:Chart review (n = 68 physicians) was used to identify consecutive ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2007.0248

    authors: Izumi R,Hurt J,Maki KC,Bell M,Zavras AI,McCamish M

    更新日期:2007-12-01 00:00:00

  • Continuous glucose monitoring and diabetes health outcomes: a critical appraisal.

    abstract::This paper presents a critical review of continuous glucose monitoring studies that address accuracy, utility in assessing glucose variability, detection of hypoglycemia for improved metabolic control or reduced glucose variability, impact on quality of life, reduced fear of hypoglycemia, and applicability in helping ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2007.0261

    authors: Reach G

    更新日期:2008-04-01 00:00:00

  • The Effectiveness of Continuous Glucose Monitoring in Patients with Type 2 Diabetes: A Systematic Review of Literature and Meta-analysis.

    abstract:BACKGROUND:Continuous glucose monitoring (CGM) provides glucose trend information that can be used to guide treatment and motivate patients with diabetes. Currently, the evidence on effectiveness of CGM in patients with type 2 diabetes is debatable. We aim to provide a systematic review and meta-analysis to synthesize ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,meta分析

    doi:10.1089/dia.2018.0177

    authors: Park C,Le QA

    更新日期:2018-09-01 00:00:00

  • Improved glycemic control after long-term insulin pump use in pediatric patients with type 1 diabetes.

    abstract:BACKGROUND:There are currently few data available on the long-term use of continuous subcutaneous insulin infusion (CSII) (insulin pump) therapy in children. METHODS:Charts from 291 youth with type 1 diabetes (T1D) who were treated with CSII therapy for at least 1 year were reviewed. Data analysis included hemoglobin ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2007.0214

    authors: Scrimgeour L,Cobry E,McFann K,Burdick P,Weimer C,Slover R,Chase HP

    更新日期:2007-10-01 00:00:00

  • Real-World Hypoglycemia Avoidance with a Continuous Glucose Monitoring System's Predictive Low Glucose Alert.

    abstract:BACKGROUND:Programmable and fixed auditory and/or vibratory threshold alerts are essential features of real-time continuous glucose monitoring (rtCGM) systems that provide users time to intervene before the onset of clinical hypoglycemia or hyperglycemia. A sixth-generation rtCGM system from Dexcom, Inc. (G6) includes ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0359

    authors: Puhr S,Derdzinski M,Welsh JB,Parker AS,Walker T,Price DA

    更新日期:2019-04-01 00:00:00

  • Management of patients with diabetes through information technology: tools for monitoring and control of the patients' metabolic behavior.

    abstract:BACKGROUND:The junction of telemedicine home monitoring with multifaceted disease management programs seems nowadays a promising direction to combine the need for an intensive approach to deal with diabetes and the pressure to contain the costs of the interventions. Several projects in the European Union and the United...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2004.6.567

    authors: Bellazzi R,Arcelloni M,Ferrari P,Decata P,Hernando ME,García A,Gazzaruso C,Gómez EJ,Larizza C,Fratino P,Stefanelli M

    更新日期:2004-10-01 00:00:00

  • Capillary and venous blood glucose concentrations measured during intravenous insulin and glucose infusion: a comparison of steady and dynamic states.

    abstract:BACKGROUND:Patients undergoing intensive insulin therapy may have blood glucose (BG) samples drawn from arterial, capillary, or venous sources. This study compared capillary and venous BG across a range of glucose concentrations and under conditions of rapid change in BG. METHODS:Following a 10-h fast, 40 adult patien...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章

    doi:10.1089/dia.2009.0023

    authors: Kempe K,Price D,Ellison J,Marhoul J,Morrow L,Win K,Kuschma K,Hompesch M

    更新日期:2009-10-01 00:00:00

  • Patients' perceptions of subcutaneous insulin in the OPTIMIZE study: a multicenter follow-up study.

    abstract:BACKGROUND:The Optimizing Control in Diabetes (OPTIMIZE) survey was conducted to understand the patients' perspective to achieving good glycemic control and to determine how patients' perceptions of insulin may affect their decisions to initiate or intensify their insulin therapy. METHODS:A total of 1,444 subjects wit...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究

    doi:10.1089/dia.2008.0249

    authors: Cefalu WT,Mathieu C,Davidson J,Freemantle N,Gough S,Canovatchel W,OPTIMIZE Coalition.

    更新日期:2008-02-01 00:00:00

  • Reimbursement for Continuous Glucose Monitoring.

    abstract::Continuous glucose monitoring (CGM) systems have been available for more than 15 years by now. However, market uptake is relatively low in most countries; in other words, relatively few patients with diabetes use CGM systems regularly. One major reason for the reluctance of patients to use CGM systems is the costs ass...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2015.0296

    authors: Heinemann L,DeVries JH

    更新日期:2016-02-01 00:00:00

  • The Impact of Short-Term Professional Continuous Glucose Monitoring on Glycemic Control Via Lifestyle Improvement.

    abstract:BACKGROUND:The efficacy of short-term professional continuous glucose monitoring (CGM) for glycemic control in patients with diabetes remains unclear. METHODS:We performed a 3-month study to evaluate the benefits of CGM in 64 patients. RESULTS:The overall glycemic control of patients who underwent CGM improved signif...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0164

    authors: Shibusawa R,Yamada E,Okada S,Nakajima Y,Bastie CC,Yamada M

    更新日期:2018-09-01 00:00:00

  • Evaluating the accuracy, reliability, and clinical applicability of continuous glucose monitoring (CGM): Is CGM ready for real time?

    abstract:BACKGROUND:This study was designed to assess the accuracy, reliability, and contribution to clinical decision-making of two commercially available continuous glucose monitoring (CGM) devices using a novel analytical approach. STUDY DESIGN:Eleven individuals with type 1 diabetes and five with type 2 diabetes wore a Gua...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2008.0041

    authors: Mazze RS,Strock E,Borgman S,Wesley D,Stout P,Racchini J

    更新日期:2009-01-01 00:00:00

  • Active assistance technology reduces glycosylated hemoglobin and weight in individuals with type 2 diabetes: results of a theory-based randomized trial.

    abstract:BACKGROUND:Type 2 diabetes is an individual health challenge requiring ongoing self-management. Remote patient reporting of relevant health parameters and linked automated feedback via mobile telephone have potential to strengthen self-management and improve outcomes. This research involved development and evaluation o...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2013.0056

    authors: Orsama AL,Lähteenmäki J,Harno K,Kulju M,Wintergerst E,Schachner H,Stenger P,Leppänen J,Kaijanranta H,Salaspuro V,Fisher WA

    更新日期:2013-08-01 00:00:00

  • NerveCheck for the Detection of Sensory Loss and Neuropathic Pain in Diabetes.

    abstract:BACKGROUND:Accurate and economic detection of nerve damage in diabetes is key to more widespread diagnosis of patients with diabetic peripheral neuropathy (DPN) and painful diabetic neuropathy. This study examined the diagnostic performance of NerveCheck, an inexpensive ($500) quantitative sensory testing (QST) device....

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2016.0279

    authors: Ponirakis G,Odriozola MN,Odriozola S,Petropoulos IN,Azmi S,Ferdousi M,Fadavi H,Alam U,Marshall A,Jeziorska M,Miro A,Kheyami A,Tavakoli M,Al-Ahmar A,Odriozola MB,Odriozola A,Malik RA

    更新日期:2016-12-01 00:00:00

  • Self-monitoring of blood glucose in diabetes: from evidence to clinical reality in Central and Eastern Europe--recommendations from the international Central-Eastern European expert group.

    abstract::Self-monitoring of blood glucose (SMBG) is universally considered to be an integral part of type 1 diabetes management and crucial for optimizing the safety and efficacy of complex insulin regimens. This extends to type 2 diabetes patients on intensive insulin therapy, and there is also a growing body of evidence sugg...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2013.0302

    authors: Czupryniak L,Barkai L,Bolgarska S,Bronisz A,Broz J,Cypryk K,Honka M,Janez A,Krnic M,Lalic N,Martinka E,Rahelic D,Roman G,Tankova T,Várkonyi T,Wolnik B,Zherdova N

    更新日期:2014-07-01 00:00:00

  • The effect of local subcutaneous delivery of vascular endothelial growth factor on the function of a chronically implanted amperometric glucose sensor.

    abstract::The foreign body capsule that forms around implanted devices such as glucose sensors is hypovascular and has limited permeability to glucose. Such a capsule may function better if well vascularized. We hypothesized that capsular vascularization achieved by local release of vascular endothelial growth factor (VEGF) wou...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/152091504773731320

    authors: Ward WK,Wood MD,Casey HM,Quinn MJ,Federiuk IF

    更新日期:2004-04-01 00:00:00

  • Continuous glucose monitoring in patients undergoing cardiac surgery.

    abstract:OBJECTIVES:Hyperglycemia is a prominent feature among patients exposed to major stress such as in cardiac surgery. The implementation of a continuous glucose monitoring system (CGMS) for glucose monitoring during cardiac surgery was assessed. SUBJECTS AND METHODS:Fifty-nine consecutive patients who underwent cardiac s...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2011.0154

    authors: Kalmovich B,Bar-Dayan Y,Boaz M,Wainstein J

    更新日期:2012-03-01 00:00:00

  • Recovery of β-cell functions with low-dose insulin therapy: study in newly diagnosed type 2 diabetes mellitus patients.

    abstract:AIM:Insulin therapy induces remission in subjects with newly diagnosed type 2 diabetes mellitus (T2DM). This study assessed the insulin and C-peptide levels in newly diagnosed T2DM subjects during low-dose insulin therapy. SUBJECTS AND METHODS:Twenty newly diagnosed, drug-naive, T2DM patients without acute or chronic ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2010.0187

    authors: Bhattacharya S,Ammini AC,Jyotsna V,Gupta N,Dwivedi S

    更新日期:2011-04-01 00:00:00

  • Adiponectin and carotid intimal medial thickness in subjects with and without glucose intolerance (CURES-82).

    abstract:OBJECTIVE:This study assessed the association of serum adiponectin with carotid intimal medial thickness (IMT) in Asian Indians with different grades of glucose intolerance. METHODS:Subjects with normal glucose tolerance (NGT) (n = 520), impaired glucose tolerance (IGT) (n = 115), and type 2 diabetes mellitus (T2DM) (...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2009.0100

    authors: Gokulakrishnan K,Indulekha K,Ganesan S,Anuradha S,Mohan V

    更新日期:2010-02-01 00:00:00

  • Lipoprotein-associated phospholipase A₂ activity predicts progression of subclinical coronary atherosclerosis.

    abstract:BACKGROUND:Lipoprotein-associated phospholipase A₂ (Lp-PLA₂) is a lipoprotein-associated enzyme that cleaves oxidized phosphatidylcholines, generating pro-atherosclerotic lysophosphatidylcholine and oxidized free fatty acids. Lp-PLA₂ is independently associated with cardiovascular disease (CVD) in a variety of populati...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2010.0175

    authors: Kinney GL,Snell-Bergeon JK,Maahs DM,Eckel RH,Ehrlich J,Rewers M,Hokanson JE

    更新日期:2011-03-01 00:00:00

  • Is angiotensin I-converting enzyme a "master" disease gene?

    abstract::Clustering of diseases has been appreciated by health insurers and epidemiologists for some time. Co-morbidity suggests shared pathways of disease. It is by now well agreed that common diseases have a strong genetic component. Here we present evidence that the angiotensin I-converting enzyme (ACE) deletion/deletion (D...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/152091502320798321

    authors: Moskowitz DW

    更新日期:2002-01-01 00:00:00

  • The impact of initiating biphasic human insulin 30 therapy in type 2 diabetes patients after failure of oral antidiabetes drugs.

    abstract:BACKGROUND:The present study evaluated the efficacy of biphasic human insulin 30 (BHI 30) in type 2 diabetes patients who had failed in therapy with two or more oral antidiabetes drugs (OADs). METHODS:This open-label, nonrandomized, 4-month, multicenter, clinical observational study was conducted in Shanghai, China. A...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究

    doi:10.1089/dia.2011.0168

    authors: Gu Y,Hou X,Zhang L,Pan J,Cai Q,Bao Y,Jia W

    更新日期:2012-03-01 00:00:00

  • Development of optimal kids insulin dosing system formulas for young children with type 1 diabetes mellitus.

    abstract:OBJECTIVE:This study was designed to develop predictive formulas for precise insulin dosing in young children with type 1 diabetes (T1DM). RESEARCH DESIGN AND METHODS:Consecutive 1-year data from a group of 14 young patients (eight girls, six boys) 3.9 ± 0.8 years old with diabetes duration of 2.0 ± 0.8 years, transit...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2011.0184

    authors: Alemzadeh R,Hoffmann RG,Dasgupta M,Parton E

    更新日期:2012-05-01 00:00:00

  • Evaluation of a Nurse-Managed Insulin Infusion Protocol.

    abstract:BACKGROUND:The purpose of this study was to evaluate the performance of an insulin infusion protocol targeting a blood glucose (BG) level of 140-180 mg/dL and to characterize protocol adherence. MATERIALS AND METHODS:This was a retrospective observational cohort study including patients for whom the protocol was order...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2015.0046

    authors: Passarelli AJ,Gibbs H,Rowden AM,Efird L,Zink E,Mathioudakis N

    更新日期:2016-02-01 00:00:00

  • What we can really expect from telemedicine in intensive diabetes treatment: results from 3-year study on type 1 pregnant diabetic women.

    abstract::Existing standards of the management of the diabetic patients are not efficient enough, and further improvement is needed. The major objective of this paper is to present and discuss the therapeutic effectiveness of an intensive care telematic system designed and applied for intensive treatment of pregnant type 1 diab...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章

    doi:10.1089/15209150152811207

    authors: Wojcicki JM,Ladyzynski P,Krzymien J,Jozwicka E,Blachowicz J,Janczewska E,Czajkowski K,Karnafel W

    更新日期:2001-01-01 00:00:00

  • Efficacy and safety performance of the Innovo insulin doser.

    abstract::Innovo (Novo Nordisk A/S, Hillerød, Denmark) is a new insulin injection system that offers built-in memory and a large, clear display to provide patients with more control during insulin injections. The aim of this trial was to compare the efficacy and safety of Innovo and NovoPen 3 (Novo Nordisk A/S) in patients expe...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1089/152091504322783413

    authors: Valk NK,Cerny G,Sieber J,Lytzen L,Berg B

    更新日期:2004-02-01 00:00:00

  • Accuracy of continuous glucose monitoring during exercise in type 1 diabetes pregnancy.

    abstract:BACKGROUND:Performance of continuous glucose monitors (CGMs) may be lower when glucose levels are changing rapidly, such as occurs during physical activity. Our aim was to evaluate accuracy of a current-generation CGM during moderate-intensity exercise in type 1 diabetes (T1D) pregnancy. SUBJECTS AND METHODS:As part o...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2012.0292

    authors: Kumareswaran K,Elleri D,Allen JM,Caldwell K,Nodale M,Wilinska ME,Amiel SA,Hovorka R,Murphy HR

    更新日期:2013-03-01 00:00:00

  • Virtual Coaching to Enhance Diabetes Care.

    abstract::Rates of diabetes are increasing worldwide and there is not a sufficient clinical workforce to care for these patients. Diabetes-related apps are a feasible way to provide diabetes education to large numbers of people with diabetes but attrition rates are high. Apps enhanced by virtual coaching may be a way to circumn...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2019.0016

    authors: Ramchandani N

    更新日期:2019-06-01 00:00:00