Abstract:
:There is a clear role for inflammation in the development of type 2 diabetes and its associated co-morbidities. Circulating inflammatory markers such as C-reactive protein, sialic acid, and interleukin- 6 are all significant independent predictors of disease. A number of nutritional components are hypothesized to modulate inflammation, and hence impact on disease risk. The most extensively studied nutrients are the long-chain n-3 polyunsaturated fatty acids. However, evidence is also emerging with respect to whole grain or low glycemic index foods and antioxidant vitamins. Obesity, resulting from long-term dietary energy excess, is also strongly linked to raised inflammatory status and type 2 diabetes. To date, much of the evidence for the effect of nutrients or foods on disease risk has been based on epidemiological associations. However, the links among diet, inflammation, and type 2 diabetes are supported by some data from human dietary intervention trials and/or mechanistic studies in animals. Further research is required to quantify the precise role and refine the evidence base. However, the proposed "anti-inflammatory" strategies to tackle type 2 diabetes are broadly consistent with current public health nutrition guidelines: to achieve and maintain a healthy weight, to reduce saturated fat, to increase the proportion of less refined forms of carbohydrate, and to increase intake of fruits and vegetables.
journal_name
Diabetes Technol Therjournal_title
Diabetes technology & therapeuticsauthors
Browning LM,Jebb SAdoi
10.1089/dia.2006.8.45keywords:
subject
Has Abstractpub_date
2006-02-01 00:00:00pages
45-54issue
1eissn
1520-9156issn
1557-8593journal_volume
8pub_type
杂志文章,评审abstract:BACKGROUND:Weight gain often occurs when insulin therapy is initiated. The long-acting insulin analog insulin detemir has been shown to be effective and well tolerated when used in basal-bolus regimens or as an add-on to oral antidiabetic drugs (OADs) and causes less weight gain than other insulins. The aim of this exp...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1089/dia.2008.0282
更新日期:2008-08-01 00:00:00
abstract:BACKGROUND:Continuous glucose monitoring (CGM) has been shown to be a valuable tool to improve glycemic control in patients with diabetes. The objective of this pilot study was to develop and implement CGM in an existing diabetes clinic for low-income patients on multiple daily injections. SUBJECTS AND METHODS:This wa...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2013.0072
更新日期:2013-10-01 00:00:00
abstract::This study was designed to determine plasma glucose and insulin levels after administration of three escalating doses of the oral insulin product hexyl-insulin monoconjugate 2 (HIM2) in fasting, insulin-deprived adult patients with type 1 diabetes. The study was also designed to assess the safety of the product. Sixte...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/152091502760306544
更新日期:2002-01-01 00:00:00
abstract:BACKGROUND:For patients with type 1 diabetes mellitus, a bihormonal artificial endocrine pancreas system utilizing glucagon and insulin has been found to stabilize glycemic control. However, commercially available formulations of glucagon cannot currently be used in such systems because of physical instability characte...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2014.0047
更新日期:2014-11-01 00:00:00
abstract:BACKGROUND:Glucose monitoring based on sampling skin interstitial fluid (ISF) is being developed as an alternative to fingerstick blood glucose monitoring. Time delays between rapidly changing levels of glucose in blood and interstitial fluid have been reported in the literature to be between 5 and 20 minutes. This stu...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/152091599317530
更新日期:1999-04-01 00:00:00
abstract:BACKGROUND:We aimed to assess the effect of continuous subcutaneous insulin infusion (CSII) therapy in patients with "recalcitrant diabetes" whose glycemia had not been controlled adequately with multiple daily injections of insulin or insulin plus oral hypoglycemic agents. PATIENTS AND METHODS:We retrospectively anal...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2009.0066
更新日期:2009-11-01 00:00:00
abstract:BACKGROUND:The management of hyperglycemia in the intensive care unit has been a controversial topic for more than a decade, with target ranges varying from 80-110 mg/dL to <200 mg/dL. Multiple insulin infusion protocols exist, including several computerized protocols, which have attempted to achieve these targets. Imp...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2016.0101
更新日期:2016-08-01 00:00:00
abstract::Basal insulin analogs are recognized as an effective method of achieving and maintaining glycemic control for patients with type 2 diabetes. However, the progressive nature of the disease means that some individuals may require additional ways to maintain their glycemic goals. Intensification in these circumstances ha...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2010.0250
更新日期:2011-09-01 00:00:00
abstract:BACKGROUND:This study explored the relationships between exogenous insulin requirements and endogenous variables in elderly patients with type 2 diabetes (T2D). SUBJECTS AND METHODS:Patients with T2D 65 years of age or older were enrolled for a short hospitalization period in order to start or change their basal-bolus...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2015.0044
更新日期:2016-05-01 00:00:00
abstract::Laser retinal photocoagulation represents the primary therapy for the potentially blinding manifestations of diabetic retinopathy. Advances in laser therapy for diabetic eye disease have arisen from the convergence of laser technology and clinical ophthalmology. In this review, the basis of laser therapy in diabetic r...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/152091599317396
更新日期:1999-07-01 00:00:00
abstract::The World Wide Web now hosts a multitude of diabetes educational materials in various formats. Of particular interest is the diabetes/insulin tutorial available at the AIDA Website (accessible directly at: www.2aida.info). The tutorial combines textual or "static" information with an interactive diabetes simulator-AID...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2006.8.126
更新日期:2006-02-01 00:00:00
abstract::Self-monitoring of blood glucose was described as one of the most important advancements in diabetes management since the invention of insulin in 1920. Recent advances in glucose sensor technology for measuring interstitial glucose concentrations have challenged the dominance of glucose meters in diabetes management, ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2009.0002
更新日期:2009-06-01 00:00:00
abstract:BACKGROUND:SAR342434 is a biosimilar follow-on of insulin lispro-Humalog®. This study aimed to show similar efficacy, safety, and immunogenicity of SAR342434 (SAR-Lis) versus insulin lispro-Humalog (Ly-Lis) in adult patients with type 1 diabetes (T1DM) treated with multiple daily injections while using basal insulin gl...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1089/dia.2017.0117
更新日期:2017-09-01 00:00:00
abstract:BACKGROUND:We evaluated the impact of a 2-year chat line involving adolescents with type 1 diabetes regarding quality of life and metabolic control. METHODS:We enrolled 193 children, 10-18 years of age (mean ± SD, 13.6 ± 2.7 years), with type 1 diabetes for 1.2-6 years (3.6 ± 2.4 years), body mass index of 23.2 ± 4.1 ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2010.0188
更新日期:2011-05-01 00:00:00
abstract:BACKGROUND:There is no consensus as to the best method to assess glycemic variability from continuous glucose monitoring (CGM) data. Rate of change has been suggested as a preferred method of assessing glycemic variability, but this assertion has not been validated. METHODS:Forty-eight hours of CGM data were analyzed ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究
doi:10.1089/dia.2010.0215
更新日期:2011-06-01 00:00:00
abstract:OBJECTIVE:Exercise is a cornerstone of diabetes therapy in type 1 diabetes mellitus (DMT1) patients. The type of exercise is important in determining the propensity to hypoglycemia. We assessed, by continuous glucose monitoring (CGM), the glucose profiles during and in the following 20h after a session of two different...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1089/dia.2010.0038
更新日期:2010-10-01 00:00:00
abstract:BACKGROUND:Real-time continuous glucose monitoring (CGM) was studied in 140 adults with diabetes over a 12-week period of home use. Hemoglobin A(1c)(HbA1c) was measured on day 1 (baseline) and at weeks 6 and 12. METHODS:On day 1, participants received the CGM device (STS(R) System, DexCom, Inc., San Diego, CA) and und...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章,多中心研究
doi:10.1089/dia.2007.0205
更新日期:2007-06-01 00:00:00
abstract:INTRODUCTION:The ProAct study has shown that a pump switch to the Accu-Chek(®) Combo system (Roche Diagnostics Deutschland GmbH, Mannheim, Germany) in type 1 diabetes patients results in stable glycemic control with significant improvements in glycated hemoglobin (HbA1c) in patients with unsatisfactory baseline HbA1c a...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章,多中心研究
doi:10.1089/dia.2014.0278
更新日期:2015-06-01 00:00:00
abstract:BACKGROUND:Gestational diabetes mellitus (GDM) is associated with adverse perinatal outcomes, if not treated. International guidelines recommend screening "all or high-risk women" at the initial prenatal visit, when a fasting plasma glucose (FPG) between 92 and 126 mg/dL is diagnostic for GDM. However, glucose testing ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2011.0225
更新日期:2012-05-01 00:00:00
abstract::Insulin infusion pump therapy has dramatically improved over the past 20 years and can now address some of the specific challenges related to toddlers with diabetes. We discuss both the non-randomized and randomized controlled trials comparing continuous subcutaneous insulin infusion (CSII) and multiple daily injectio...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2009.0182
更新日期:2010-06-01 00:00:00
abstract:BACKGROUND:The objective of this investigation was to evaluate the test-retest repeatability of insulin sensitivity and secretion indices derived from liquid meal tolerance tests (MTTs) in subjects with normal fasting glucose (NFG) (n = 20), impaired fasting glucose (IFG) (n = 20), or type 2 diabetes mellitus (n = 38)....
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2010.0083
更新日期:2010-11-01 00:00:00
abstract:BACKGROUND:Children with positive islet autoantibodies monitored prospectively avoid metabolic decompensation at type 1 diabetes (T1D) diagnosis. However, the effects of early diagnosis and treatment on preservation of insulin secretion and long-term metabolic control are unknown. We compared characteristics of childre...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2015.0029
更新日期:2015-09-01 00:00:00
abstract:: Background: Glycemic variability (GV) is an important component of glycemic control for patients with type 1 diabetes (T1D). The inadequacy of existing measurements lies in the fact that they view the variability from different aspects, so that no consensus has been reache...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2019.0250
更新日期:2020-04-01 00:00:00
abstract::Maintaining optimal blood glucose (BG) control is difficult for type 1 diabetes mellitus (T1DM) patients when typical daily regimens of food, insulin and exercise are altered. Artificial intelligence (AI) systems consisting of treatment algorithms calibrated through large datasets of patient specific information may o...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/15209150050501989
更新日期:2000-01-01 00:00:00
abstract:BACKGROUND:Applying real-time learning into an artificial pancreas system could effectively track the unpredictable behavior of glucose-insulin dynamics and adjust insulin treatment accordingly. We describe a novel learning algorithm and its performance when integrated into the MD-Logic Artificial Pancreas (MDLAP) syst...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2010.0216
更新日期:2011-10-01 00:00:00
abstract:BACKGROUND:This study evaluated whether education and use of the advanced meter features of the CONTOUR(®) (Bayer HealthCare LLC, Diabetes Care, Tarrytown, NY) blood glucose monitoring system (BGMS) affect the frequency and pattern of blood glucose testing in insulin-using subjects with diabetes who routinely perform s...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1089/dia.2012.0051
更新日期:2012-10-01 00:00:00
abstract:BACKGROUND:During the proteomic era, one of the most rapidly growing areas in biomedical research is biomarker discovery, particularly using proteomic technologies. The urinary proteome is known to be a valuable field of study and has become one of the most attractive subdisciplines in clinical proteomics for human dis...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2010.0078
更新日期:2010-12-01 00:00:00
abstract:BACKGROUND:Continuous glucose monitoring is a useful tool for the achievement of improved glucose control in patients with diabetes. We tested the ability of a novel noninvasive continuous glucose monitor to track glucose excursions. METHODS:The novel noninvasive Aprise sensor (Glucon Inc., Boulder, CO) utilizes the p...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章
doi:10.1089/dia.2006.0059
更新日期:2007-02-01 00:00:00
abstract:BACKGROUND:We assessed the impact of using an automated bolus advisor integrated into a blood glucose meter on the timing and frequency of adjusting insulin therapy parameter settings and whether the availability of this technology would increase blood glucose test strip utilization in diabetes patients treated with mu...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1089/dia.2013.0280
更新日期:2014-05-01 00:00:00
abstract:BACKGROUND:Prediction of glycemic profile is an important task for both early recognition of hypoglycemia and enhancement of the control algorithms for optimization of insulin infusion rate. Adaptive models for glucose prediction and recognition of hypoglycemia based on statistical and artificial intelligence technique...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2011.0093
更新日期:2012-02-01 00:00:00