Abstract:
BACKGROUND:We assessed the impact of using an automated bolus advisor integrated into a blood glucose meter on the timing and frequency of adjusting insulin therapy parameter settings and whether the availability of this technology would increase blood glucose test strip utilization in diabetes patients treated with multiple daily insulin injection (MDI) therapy. SUBJECTS AND METHODS:The Automated Bolus Advisor Control and Usability Study (ABACUS) trial, a 26-week, prospective, randomized, controlled, multinational study that enrolled 218 type 1 and type 2 diabetes patients, demonstrated that use of an automated insulin bolus advisor helps improve glycemic control in suboptimally controlled, MDI-treated patients. Patient data were assessed to determine when and how often changes in insulin parameter settings occurred during the study. Patient meters were downloaded to determine blood glucose monitoring frequency. RESULTS:One hundred ninety-three patients completed the study: 93 control arm (CNL) and 100 intervention (experimental) arm (EXP). Significantly more EXP (47.5%) than CNL (30.7%) patients received one or more changes in their insulin sensitivity factor (ISF) settings during the study (P=0.0191). Changes in ISF settings occurred earlier and more frequently in EXP than CNL patients throughout the study. A similar trend was seen in changes in insulin-to-carbohydrate ratios. There were no differences in daily self-monitoring of blood glucose frequency [mean (SD)] between CNL and EXP patients: 4.7 (1.5) versus 4.6 (1.3) (P=0.4085). CONCLUSIONS:Use of an automated bolus advisor was associated with earlier, more frequent changes in key insulin parameters, which may have contributed to subsequent improvements in glycemic control but without increased glucose test strip utilization.
journal_name
Diabetes Technol Therjournal_title
Diabetes technology & therapeuticsauthors
Cavan DA,Ziegler R,Cranston I,Barnard K,Ryder J,Vogel C,Parkin CG,Koehler W,Vesper I,Petersen B,Schweitzer MA,Wagner RSdoi
10.1089/dia.2013.0280subject
Has Abstractpub_date
2014-05-01 00:00:00pages
310-6issue
5eissn
1520-9156issn
1557-8593journal_volume
16pub_type
杂志文章,多中心研究,随机对照试验abstract::Laser retinal photocoagulation represents the primary therapy for the potentially blinding manifestations of diabetic retinopathy. Advances in laser therapy for diabetic eye disease have arisen from the convergence of laser technology and clinical ophthalmology. In this review, the basis of laser therapy in diabetic r...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/152091599317396
更新日期:1999-07-01 00:00:00
abstract:BACKGROUND:Insulin pumps (for continuous subcutaneous insulin infusion [CSII]) are used widely in type 1 diabetes mellitus. Although there has been considerable study of outcomes, there are few recent data on CSII-associated adverse events and no data on family perceptions of adverse events and their confidence in deal...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2013.0315
更新日期:2014-04-01 00:00:00
abstract:BACKGROUND:Balance is sensed through peripheral and central receptors and mediated by central control through the brain and spinal cord. Although some evidence exists as to the areas of the brain involved and how processing of data occurs in young individuals, nothing has been published on people with diabetes. The pur...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2012.0152
更新日期:2012-11-01 00:00:00
abstract:: Background: Continuous glucose monitoring (CGM) systems are widely and increasingly used in diabetes self-management and in the context of clinic visits. However, access to CGM data during visits can be challenging. Clinic inefficiencies can restrict the time available for...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2019.0377
更新日期:2020-08-01 00:00:00
abstract:: Objective: To assess the degree, duration, mean absolute relative difference (MARD), and error analysis of discrepant values per continuous glucose monitoring (CGM) systems after hydroxyurea (HU) administration. Research Design and Methods: ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2020.0490
更新日期:2020-12-30 00:00:00
abstract::There are three main issues in non-invasive (NI) glucose measurements: namely, specificity, compartmentalization of glucose values, and calibration. There has been progress in the use of near-infrared and mid-infrared spectroscopy. Recently new glucose measurement methods have been developed, exploiting the effect of ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2004.6.660
更新日期:2004-10-01 00:00:00
abstract:BACKGROUND:Lipohypertrophy (LH) is a complication of insulin therapy. We assessed LH prevalence, risk factors, insulin usage, and clinical and health economic effects in China. METHODS:In four cities, 401 adult patients injecting insulin ≥1 year were surveyed for diabetes/insulin injection history and practices, pen n...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2016.0334
更新日期:2017-01-01 00:00:00
abstract:BACKGROUND:Previous studies of aerobic exercise have found lower sensor accuracy during exercise. Whether or not resistance exercise would also be associated with lower sensor accuracy has not yet been examined. This study sought to investigate the accuracy of continuous glucose monitoring sensor values at rest, during...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2012.0182
更新日期:2013-01-01 00:00:00
abstract:BACKGROUND:Weight gain often occurs when insulin therapy is initiated. The long-acting insulin analog insulin detemir has been shown to be effective and well tolerated when used in basal-bolus regimens or as an add-on to oral antidiabetic drugs (OADs) and causes less weight gain than other insulins. The aim of this exp...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1089/dia.2008.0282
更新日期:2008-08-01 00:00:00
abstract:BACKGROUND:This exploratory study examined the pharmacokinetics and pharmacodynamics of a Bentley Pharmaceuticals, Inc. (North Hampton, NH) proprietary insulin formulation utilizing CPE-215 technology designed for intranasal administration. METHODS:Eight fasting healthy volunteers (four men, four women; body mass inde...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章
doi:10.1089/dia.2005.7.124
更新日期:2005-02-01 00:00:00
abstract:BACKGROUND:Type 1 diabetic patients have high instability of daily glucose levels. The aim of this study was to evaluate the long-term effects of continuous subcutaneous insulin infusion (CSII) therapy, compared with multiple daily injections of insulin (MDI), on glucose variability, in young type 1 diabetic patients t...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2017.0334
更新日期:2018-02-01 00:00:00
abstract:BACKGROUND:For patients with type 1 diabetes mellitus, a bihormonal artificial endocrine pancreas system utilizing glucagon and insulin has been found to stabilize glycemic control. However, commercially available formulations of glucagon cannot currently be used in such systems because of physical instability characte...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2014.0047
更新日期:2014-11-01 00:00:00
abstract::Empowerment plays significant roles in the complex management of type 2 diabetes. International guidelines have provided recommendations on management of Muslims who fast during Ramadan. However, there remains a lack of patient-centered epistemic tool to empower healthcare providers and patients in managing diabetes d...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2018.0159
更新日期:2018-10-01 00:00:00
abstract::It is widely accepted that noninvasive glucose monitoring (NIGM) has the potential to revolutionize diabetes therapy. However, current approaches to NIGM studied to date have not yet demonstrated a level of acceptable functionality to allow real-time use, beyond restricted fields of application. A number of reviews ha...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2009.0095
更新日期:2010-01-01 00:00:00
abstract:BACKGROUND:We aimed to assess the effect of continuous subcutaneous insulin infusion (CSII) therapy in patients with "recalcitrant diabetes" whose glycemia had not been controlled adequately with multiple daily injections of insulin or insulin plus oral hypoglycemic agents. PATIENTS AND METHODS:We retrospectively anal...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2009.0066
更新日期:2009-11-01 00:00:00
abstract:BACKGROUND:Applying real-time learning into an artificial pancreas system could effectively track the unpredictable behavior of glucose-insulin dynamics and adjust insulin treatment accordingly. We describe a novel learning algorithm and its performance when integrated into the MD-Logic Artificial Pancreas (MDLAP) syst...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2010.0216
更新日期:2011-10-01 00:00:00
abstract:: Background: Continuous subcutaneous insulin infusion (CSII) is associated with improved glycemic control, a reduced incidence of hypoglycemia, and improved quality of life (QOL). To date, however, there has been no QOL scale specific to CSII. The objective of this study wa...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2019.0216
更新日期:2020-03-01 00:00:00
abstract:BACKGROUND:Different reference methods are used for the accuracy assessment of continuous glucose monitoring (CGM) systems. The effect of using venous, arterialized-venous, or capillary reference measurements on CGM accuracy is unclear. METHODS:We evaluated 21 individuals with type 1 diabetes using a capillary calibra...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2017.0189
更新日期:2017-11-01 00:00:00
abstract:BACKGROUND:The Optimizing Control in Diabetes (OPTIMIZE) survey was conducted to understand the patients' perspective to achieving good glycemic control and to determine how patients' perceptions of insulin may affect their decisions to initiate or intensify their insulin therapy. METHODS:A total of 1,444 subjects wit...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究
doi:10.1089/dia.2008.0249
更新日期:2008-02-01 00:00:00
abstract:OBJECTIVE:We sought to cross validate several metrics for quality of glycemic control, hypoglycemia, and hyperglycemia. RESEARCH DESIGN AND METHODS:We analyzed the mathematical properties of several metrics for overall glycemic control, and for hypo- and hyperglycemia, to evaluate their similarities, differences, and ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2017.0416
更新日期:2018-05-01 00:00:00
abstract:BACKGROUND:Glucose monitoring based on sampling skin interstitial fluid (ISF) is being developed as an alternative to fingerstick blood glucose monitoring. Time delays between rapidly changing levels of glucose in blood and interstitial fluid have been reported in the literature to be between 5 and 20 minutes. This stu...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/152091599317530
更新日期:1999-04-01 00:00:00
abstract:BACKGROUND:This article reports a prolonged trial with insulin pumps implanted in patients with type 1 diabetes showing poor glucose control and a high rate of complications. METHODS:We reviewed data from 181 patients undergoing implanted insulin pump therapy. Analysis included hemoglobin A1c (HbA1c) values, body weig...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2010.0209
更新日期:2011-06-01 00:00:00
abstract:BACKGROUND:Computer simulation environments have been used in the development of many artificial pancreas systems. A glucose sensor model is an essential part of these environments, and different models have been proposed. However, not one of these models accounts for drop-outs of sensor readings, a well-known phenomen...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2014.0309
更新日期:2015-06-01 00:00:00
abstract:OBJECTIVE:This study was designed to assess whether waist circumference can predict metabolic syndrome abnormalities in primary schoolchildren. RESEARCH DESIGN AND METHODS:Of 5,103 children (2,526 males) 4-13 years old who underwent anthropometric measurements, 530 had more extensive testing. Body mass index (BMI), wa...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究
doi:10.1089/dia.2006.0017
更新日期:2007-04-01 00:00:00
abstract:OBJECTIVE:Exercise is a cornerstone of diabetes therapy in type 1 diabetes mellitus (DMT1) patients. The type of exercise is important in determining the propensity to hypoglycemia. We assessed, by continuous glucose monitoring (CGM), the glucose profiles during and in the following 20h after a session of two different...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1089/dia.2010.0038
更新日期:2010-10-01 00:00:00
abstract:BACKGROUND:Glucose variability has been identified as a predictor of hypoglycemia and has been associated with mortality in critically ill patients without diabetes. A popular metric to quantify glucose variability is the mean amplitude of glycemic excursions (MAGE). The "ruler and pencil" approach to calculate MAGE is...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2013.0138
更新日期:2014-02-01 00:00:00
abstract:: Aims: We evaluated the real-life efficacy and safety of empagliflozin in combination with optimized insulin therapy in patients with type 1 diabetes (T1D). Methods: This was a prospective study, including 27 patients with T1D t...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2019.0316
更新日期:2020-03-01 00:00:00
abstract:BACKGROUND AND OBJECTIVE:Hyperglycemia occurs commonly in patients admitted to medical intensive care units (MICUs). Whether real-time (RT) continuous glucose monitoring (CGM) improves glycemic control and variability and reduces hypoglycemia in severely ill MICU patients with an Acute Physiology and Chronic Health Eva...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1089/dia.2015.0151
更新日期:2015-12-01 00:00:00
abstract:: Background: International consensus on the use of continuous glucose monitoring (CGM) recommends coefficient of variation (CV) as the metric of choice to express glycemic variability (GV) with a cutoff of 36% to define unstable diabetes. Even though, CV is associated with ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2019.0075
更新日期:2019-08-01 00:00:00
abstract::This study was designed to assess the frequency of the dawn phenomenon in patients with type 2 diabetes. A secondary aim was to examine the influence of varying treatment regimens on the frequency of the dawn phenomenon. The dawn phenomenon was defined as a rise in plasma glucose levels of > or = 0.5 mmol/L (10 mg/dL)...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章
doi:10.1089/152091502320798213
更新日期:2002-01-01 00:00:00