Abstract:
BACKGROUND AND OBJECTIVE:Hyperglycemia occurs commonly in patients admitted to medical intensive care units (MICUs). Whether real-time (RT) continuous glucose monitoring (CGM) improves glycemic control and variability and reduces hypoglycemia in severely ill MICU patients with an Acute Physiology and Chronic Health Evaluation II (APACHE-II) score of ≥20 has not been studied. SUBJECTS AND METHODS:Thirty-five patients (66 ± 10 years of age; APACHE-II score, 28 ± 6) were randomly assigned to RT-CGM (n = 16) using the GlucoDay(®)S (A. Menarini Diagnostics, Florence, Italy) device or to blinded CGM. Insulin was infused using a modified Yale protocol targeting a blood glucose level between 80 and 120 mg/dL. Outcome measures were percentage of time in normoglycemia (80-110 mg/dL) and in hypoglycemia (<60 mg/dL), glycemic variability (SD, coefficient of variation, mean amplitude of glucose excursions, and mean of daily differences), and CGM accuracy (error grid analyses, Bland-Altman bias plot, and mean absolute relative deviation). RESULTS:During 96 h of monitoring, glycemia reached target (80-110 mg/dL) in 37 ± 15%, was between 70 and 180 mg/dL in 91 ± 10%, and <60 mg/dL in 2 ± 2% of the time. In the RT-CGM group glycemia averaged 119 ± 17 mg/dL versus 122 ± 11 mg/dL in the control group. Parameters of glucose variability and percentages of time at target glycemia and in hypoglycemia were similar between groups. GlucoDayS values and arterial glycemia correlated well, with 98.6% of data falling in Zones A and B of the error grid analysis. Mean absolute relative devation was 11.2%. CONCLUSIONS:RT-CGM did not ameliorate glucose control or variability; neither did it reduce the number of hypoglycemic events, but our insulin infusion protocol led to overall good glucose control without a significant hypoglycemia risk, making further improvement difficult.
journal_name
Diabetes Technol Therjournal_title
Diabetes technology & therapeuticsauthors
De Block CE,Gios J,Verheyen N,Manuel-y-Keenoy B,Rogiers P,Jorens PG,Scuffi C,Van Gaal LFdoi
10.1089/dia.2015.0151subject
Has Abstractpub_date
2015-12-01 00:00:00pages
889-98issue
12eissn
1520-9156issn
1557-8593journal_volume
17pub_type
杂志文章,多中心研究,随机对照试验abstract::Clustering of diseases has been appreciated by health insurers and epidemiologists for some time. Co-morbidity suggests shared pathways of disease. It is by now well agreed that common diseases have a strong genetic component. Here we present evidence that the angiotensin I-converting enzyme (ACE) deletion/deletion (D...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/152091502320798321
更新日期:2002-01-01 00:00:00
abstract::Insulin infusion pump therapy has dramatically improved over the past 20 years and can now address some of the specific challenges related to toddlers with diabetes. We discuss both the non-randomized and randomized controlled trials comparing continuous subcutaneous insulin infusion (CSII) and multiple daily injectio...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2009.0182
更新日期:2010-06-01 00:00:00
abstract:BACKGROUND:Long-term treatment is necessary to slow the progression of type 2 diabetes (T2D). Here, we examined the safety and efficacy of 6 years of treatment with exenatide once weekly (QW) among patients with T2D in the DURATION-1 trial. METHODS:The study enrolled patients aged ≥16 years with T2D treated primarily ...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章
doi:10.1089/dia.2016.0107
更新日期:2016-11-01 00:00:00
abstract::Background Glycated hemoglobin A1c (HbA1c) is a key biomarker in the glycemic management of individuals with diabetes but the relationship with glucose levels can be variable. A recent kinetic model has described a calculated HbA1c (cHbA1c) that is individual-specific. Our aim was to validate the routine clinical use ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2020.0553
更新日期:2021-01-04 00:00:00
abstract::By the year 2030, the diabetes pandemic will likely affect more than 10% of the world's population. The personal, public health, and economic crises implicit in this trend call for decisive action. Yet, escalating dilemmas thwart full realization of current therapies. First, controversial studies, such as the Action t...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2012.0132
更新日期:2012-11-01 00:00:00
abstract:BACKGROUND:The purpose of this study is to test the agreement between energy expenditure estimate of the SenseWear(®) Armband Pro3 (SWA) (BodyMedia, Pittsburgh, PA) and the Omron HJ-720 (Omron Healthcare, Kyoto, Japan) step counter with indirect calorimetry (IC) as a gold standard in older individuals with type 1 and t...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2012.0235
更新日期:2013-05-01 00:00:00
abstract:BACKGROUND:Little information is available regarding glucose fluctuations in postprandial states and during the oral glucose tolerance test (OGTT) in Japanese people with normal glucose tolerance (NGT). METHODS:Glucose profiles of 27 Japanese people were measured for 4 days by using continuous glucose monitoring. A 75...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2008.0083
更新日期:2009-07-01 00:00:00
abstract::Disease registries are a searchable list of all patients with a particular chronic condition that often interface with an electronic medical record. The well-designed registry links all members of the patient's health team and provides key information for patients and physicians. The critical impact of a registry is t...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2008.0057
更新日期:2009-04-01 00:00:00
abstract::Laser retinal photocoagulation represents the primary therapy for the potentially blinding manifestations of diabetic retinopathy. Advances in laser therapy for diabetic eye disease have arisen from the convergence of laser technology and clinical ophthalmology. In this review, the basis of laser therapy in diabetic r...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/152091599317396
更新日期:1999-07-01 00:00:00
abstract::This study was designed to determine plasma glucose and insulin levels after administration of three escalating doses of the oral insulin product hexyl-insulin monoconjugate 2 (HIM2) in fasting, insulin-deprived adult patients with type 1 diabetes. The study was also designed to assess the safety of the product. Sixte...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/152091502760306544
更新日期:2002-01-01 00:00:00
abstract:BACKGROUND:To examine trimester-specific associations among glycemic variability, fetal growth, and birthweight in pregnancies with type 1 diabetes mellitus (Type 1 DM). METHODS:In this retrospective cohort study of 41 pregnant women with Type 1 DM, we used continuous glucose monitoring (CGM) data to calculate glycemi...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2017.0443
更新日期:2018-06-01 00:00:00
abstract:BACKGROUND:Pregnancy and early motherhood are extraordinarily demanding periods for women with type 1 diabetes, who therefore need optimal support. This article describes the process of developing person-centered Web-based support for women with type 1 diabetes during the period of pregnancy through early motherhood. I...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2012.0217
更新日期:2013-01-01 00:00:00
abstract:OBJECTIVE:This study assessed the association of serum adiponectin with carotid intimal medial thickness (IMT) in Asian Indians with different grades of glucose intolerance. METHODS:Subjects with normal glucose tolerance (NGT) (n = 520), impaired glucose tolerance (IGT) (n = 115), and type 2 diabetes mellitus (T2DM) (...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2009.0100
更新日期:2010-02-01 00:00:00
abstract:: Background: Glycemic variability (GV) is an important component of glycemic control for patients with type 1 diabetes (T1D). The inadequacy of existing measurements lies in the fact that they view the variability from different aspects, so that no consensus has been reache...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2019.0250
更新日期:2020-04-01 00:00:00
abstract:UNLABELLED:Abstract Objective: Controlled inpatient studies on the effects of food, physical activity (PA), and insulin dosing on glucose excursions exist, but such outpatient data are limited. We report here outpatient data on glucose excursions and its key determinants over 5 days in 30 adolescents with type 1 diab...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2012.0053
更新日期:2012-08-01 00:00:00
abstract:BACKGROUND:There are currently few data available on the long-term use of continuous subcutaneous insulin infusion (CSII) (insulin pump) therapy in children. METHODS:Charts from 291 youth with type 1 diabetes (T1D) who were treated with CSII therapy for at least 1 year were reviewed. Data analysis included hemoglobin ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2007.0214
更新日期:2007-10-01 00:00:00
abstract:OBJECTIVES:Hyperglycemia is a prominent feature among patients exposed to major stress such as in cardiac surgery. The implementation of a continuous glucose monitoring system (CGMS) for glucose monitoring during cardiac surgery was assessed. SUBJECTS AND METHODS:Fifty-nine consecutive patients who underwent cardiac s...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2011.0154
更新日期:2012-03-01 00:00:00
abstract::Diabetic nephropathy is one of the major causes of end-stage renal disease and is often associated with other macrovascular complications such as ischemic heart disease and peripheral vascular disease. Angiotensin converting enzyme inhibitors (ACE-I) and angiotensin II receptor blockers (AIIR) have both been shown to ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/152091502760098456
更新日期:2002-01-01 00:00:00
abstract:AIM:The aim of this study was to assess the associations of six single nucleotide polymorphisms (SNPs) of three genes (DRD3, COMT, and SCL6A4) with type 2 diabetes mellitus (T2DM) in Southern Chinese. SUBJECTS AND METHODS:Five hundred ninety-five cases with T2DM and 725 healthy controls of Han origin were recruited fr...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2014.0344
更新日期:2015-08-01 00:00:00
abstract::Empowerment plays significant roles in the complex management of type 2 diabetes. International guidelines have provided recommendations on management of Muslims who fast during Ramadan. However, there remains a lack of patient-centered epistemic tool to empower healthcare providers and patients in managing diabetes d...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2018.0159
更新日期:2018-10-01 00:00:00
abstract::We report the first case of the use of continuous subcutaneous insulin infusion (CSII) in a patient with Shwachman-Bodian-Diamond syndrome (SBDS) and diabetes. An Italian boy received diagnosis of SBDS at the age of 7 months (SBDS gene mutation: c.183-184TA → CT and c.258 + 2 T → C in compound heterozygous). The patie...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2014.0184
更新日期:2015-01-01 00:00:00
abstract:AIMS:This study compared glycemic control and maternal and fetal outcomes in pregnant women with type 1 diabetes mellitus (T1DM) treated with multiple daily injections (MDI) or continuous subcutaneous insulin infusion (CSII) using regular (RI) or lispro (LP) insulin. METHODS:Three hundred fifteen consecutive singleton...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2010.0111
更新日期:2010-12-01 00:00:00
abstract:BACKGROUND:This article reports a prolonged trial with insulin pumps implanted in patients with type 1 diabetes showing poor glucose control and a high rate of complications. METHODS:We reviewed data from 181 patients undergoing implanted insulin pump therapy. Analysis included hemoglobin A1c (HbA1c) values, body weig...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2010.0209
更新日期:2011-06-01 00:00:00
abstract:BACKGROUND:The value of self-monitoring of blood glucose (SMBG) for persons with type 2 diabetes who do not use insulin remains controversial. This observational study compares the likelihood of medication adherence and change in glycated hemoglobin (A1C) for non-insulin-using patients using SMBG versus those not using...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2012.0047
更新日期:2012-09-01 00:00:00
abstract:PURPOSE:This study investigated reasons for the rejection and discontinuation of insulin pump therapy and explored general attitudes towards this mode of therapy among young patients with type 1 diabetes. METHODS:A questionnaire was developed using a focus group of young people with diabetes. It was then used to surve...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2009.0080
更新日期:2010-01-01 00:00:00
abstract:BACKGROUND:Implanted insulin pumps using the peritoneal route provide long-term improvement of glucose control compared with subcutaneous insulin therapy in type 1 diabetes (T1D) patients. The stability of insulin preparation is critical for a safe use in implanted pumps. Insuman implantable(®) (400 IU/mL) (Sanofi-Aven...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1089/dia.2013.0369
更新日期:2014-09-01 00:00:00
abstract:BACKGROUND:The Ascensia CONTOUR System (Bayer HealthCare LLC, Elkhart, IN) is a new blood glucose (BG) monitoring system (BGMS) that uses glucose dehydrogenase chemistry and that combines low sample volume, fast response time, an auto-control marking feature, and an auto-calibration function in a small package. METHOD...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究
doi:10.1089/dia.2005.7.283
更新日期:2005-04-01 00:00:00
abstract:BACKGROUND:The purpose of this study was to evaluate the performance of an insulin infusion protocol targeting a blood glucose (BG) level of 140-180 mg/dL and to characterize protocol adherence. MATERIALS AND METHODS:This was a retrospective observational cohort study including patients for whom the protocol was order...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2015.0046
更新日期:2016-02-01 00:00:00
abstract::Maintaining optimal blood glucose (BG) control is difficult for type 1 diabetes mellitus (T1DM) patients when typical daily regimens of food, insulin and exercise are altered. Artificial intelligence (AI) systems consisting of treatment algorithms calibrated through large datasets of patient specific information may o...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/15209150050501989
更新日期:2000-01-01 00:00:00
abstract::Type 2 diabetes is characterized by insulin resistance and progressive β-cell deterioration. As β-cell function declines, most patients with type 2 diabetes treated with oral agents, in monotherapy or combination, will require insulin therapy. Addition of basal insulin (glargine, detemir, or NPH/neutral protamine lisp...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2011.0001
更新日期:2011-06-01 00:00:00