Evaluation of a new blood glucose monitoring system with auto-calibration.

Abstract:

BACKGROUND:The Ascensia CONTOUR System (Bayer HealthCare LLC, Elkhart, IN) is a new blood glucose (BG) monitoring system (BGMS) that uses glucose dehydrogenase chemistry and that combines low sample volume, fast response time, an auto-control marking feature, and an auto-calibration function in a small package. METHODS:The system was evaluated at four diabetes clinics with ambulatory subjects who had diabetes. The BGMS was tested by both health care professionals (HCPs) and lay users. It was also evaluated at high altitude (10,200 feet) and, in conjunction with the Ascensia MICROLET VACULANCE (Bayer), for use with samples obtained from four alternative anatomical sites. RESULTS:When the system was used with blood from fingersticks, both lay users and HCPs obtained results that fulfilled the International Organization for Standardization (ISO) 15197:2003 accuracy criteria, which advocate that 95% of BG measurements should fall within +/-15 mg/dL (for BG concentrations <75 mg/dL) or +/-20% (for BG concentrations > or = 75 mg/dL) of the laboratory value. Lay users obtained 96.9% of glucose results, and HCPs obtained 96.4% of glucose results, within ISO accuracy criteria. People with diabetes who had no prior experience using the system also obtained acceptable results (97.0%), as did the HCP using fingerstick samples from subjects in the high altitude study (97.0%). Among the alternative anatomical sites tested, only the results from the palm met the ISO criteria (97.5%), although the results from all four sites (palm, thigh, abdomen, and forearm) were clinically acceptable when assessed using error grid analysis. Most subjects rated the BGMS as either excellent or very good in a questionnaire, and were able to use it properly without training. CONCLUSIONS:These findings indicate that the Ascensia CONTOUR System, which does not require calibration by the user, is a convenient and accurate instrument with useful features for people who routinely monitor BG.

journal_name

Diabetes Technol Ther

authors

Kilo C,Pinson M,Joynes JO,Joseph H,Monhaut N,Parkes JL,Baum J

doi

10.1089/dia.2005.7.283

keywords:

subject

Has Abstract

pub_date

2005-04-01 00:00:00

pages

283-94

issue

2

eissn

1520-9156

issn

1557-8593

journal_volume

7

pub_type

杂志文章,多中心研究
  • Incidence and Predictors of Dysglycemia and Regression to Normoglycemia in Indian Adolescents and Young Adults: 10-Year Follow-Up of the ORANGE Study.

    abstract:: Background: The prevalence of diabetes in youth is increasing worldwide in parallel with the obesity epidemic. This study aimed to determine the incidence rates of dysglycemia (diabetes or prediabetes) and evaluate the predictors of its progression or regression to normal ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2020.0109

    authors: Mehreen TS,Kamalesh R,Pandiyan D,Kumar DS,Anjana RM,Mohan V,Ranjani H

    更新日期:2020-12-01 00:00:00

  • Reduction in hemoglobin A1C with real-time continuous glucose monitoring: results from a 12-week observational study.

    abstract:BACKGROUND:Real-time continuous glucose monitoring (CGM) was studied in 140 adults with diabetes over a 12-week period of home use. Hemoglobin A(1c)(HbA1c) was measured on day 1 (baseline) and at weeks 6 and 12. METHODS:On day 1, participants received the CGM device (STS(R) System, DexCom, Inc., San Diego, CA) and und...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1089/dia.2007.0205

    authors: Bailey TS,Zisser HC,Garg SK

    更新日期:2007-06-01 00:00:00

  • Enzymatic fluorescent microsphere glucose sensors:evaluation of response under dynamic conditions.

    abstract::Most previous attempts at the development of a "smart tattoo" for glucose monitoring in diabetes--implantable fluorescent microspheres that can be implanted intradermally and interrogated transdermally using light--have focused on the encapsulation of a competitive binding assay for glucose within hydrogel microsphere...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2006.8.288

    authors: Brown JQ,Srivastava R,Zhu H,McShane MJ

    更新日期:2006-06-01 00:00:00

  • Evaluating rate of change as an index of glycemic variability, using continuous glucose monitoring data.

    abstract:BACKGROUND:There is no consensus as to the best method to assess glycemic variability from continuous glucose monitoring (CGM) data. Rate of change has been suggested as a preferred method of assessing glycemic variability, but this assertion has not been validated. METHODS:Forty-eight hours of CGM data were analyzed ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究

    doi:10.1089/dia.2010.0215

    authors: Whitelaw BC,Choudhary P,Hopkins D

    更新日期:2011-06-01 00:00:00

  • Feasibility of continuous subcutaneous insulin infusion and daily supplemental insulin glargine injection in children with type 1 diabetes.

    abstract:BACKGROUND:Continuous subcutaneous insulin infusion (CSII) is an effective method of insulin substitution with increased risk of hypoglycemia and diabetic ketoacidosis (DKA) in rare situations. The lack of subcutaneous long-acting insulin and short half-life of serum insulin increases the risk of ketosis and DKA follow...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2008.0124

    authors: Alemzadeh R,Parton EA,Holzum MK

    更新日期:2009-08-01 00:00:00

  • Oral insulin product hexyl-insulin monoconjugate 2 (HIM2) in type 1 diabetes mellitus: the glucose stabilization effects of HIM2.

    abstract::This study was designed to determine plasma glucose and insulin levels after administration of three escalating doses of the oral insulin product hexyl-insulin monoconjugate 2 (HIM2) in fasting, insulin-deprived adult patients with type 1 diabetes. The study was also designed to assess the safety of the product. Sixte...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/152091502760306544

    authors: Clement S,Still JG,Kosutic G,McAllister RG

    更新日期:2002-01-01 00:00:00

  • ROSSO-in-praxi: a self-monitoring of blood glucose-structured 12-week lifestyle intervention significantly improves glucometabolic control of patients with type 2 diabetes mellitus.

    abstract:BACKGROUND:As healthy diet and physical activity can improve glucometabolic control in patients with type 2 diabetes, lifestyle changes should be the basis for each therapy. The only tool to visualize immediate effects of food pattern and exercise on blood glucose levels is self-monitoring of blood glucose (SMBG). Ther...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2010.0008

    authors: Kempf K,Kruse J,Martin S

    更新日期:2010-07-01 00:00:00

  • Perioperative Characteristics of the Accuracy of Subcutaneous Continuous Glucose Monitoring: Pilot Study in Neurosurgery and Cardiac Surgery.

    abstract:BACKGROUND:The aim of this study was to elucidate the characteristics of accuracy of subcutaneous continuous glucose monitoring (SCGM) in the perioperative period for neurosurgical and cardiac surgery patients. METHODS:Forty-five subjects, including healthy volunteers (n = 15), neurosurgical patients (n = 15), and car...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0140

    authors: Sugiyama Y,Wakabayashi R,Urasawa M,Maruyama Y,Shimizu S,Kawamata M

    更新日期:2018-10-01 00:00:00

  • Nocturnal continuous glucose monitoring: accuracy and reliability of hypoglycemia detection in patients with type 1 diabetes at high risk of severe hypoglycemia.

    abstract:BACKGROUND:A reliable method to detect biochemical nocturnal hypoglycemia is highly needed, especially in patients with recurrent severe hypoglycemia. We evaluated reliability of nocturnal continuous glucose monitoring (CGM) in patients with type 1 diabetes at high risk of severe hypoglycemia. PATIENTS AND METHODS:Sev...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1089/dia.2013.0004

    authors: Bay C,Kristensen PL,Pedersen-Bjergaard U,Tarnow L,Thorsteinsson B

    更新日期:2013-05-01 00:00:00

  • Efficacy and Safety of Biosimilar SAR342434 Insulin Lispro in Adults with Type 1 Diabetes Also Using Insulin Glargine-SORELLA 1 Study.

    abstract:BACKGROUND:SAR342434 is a biosimilar follow-on of insulin lispro-Humalog®. This study aimed to show similar efficacy, safety, and immunogenicity of SAR342434 (SAR-Lis) versus insulin lispro-Humalog (Ly-Lis) in adult patients with type 1 diabetes (T1DM) treated with multiple daily injections while using basal insulin gl...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1089/dia.2017.0117

    authors: Garg SK,Wernicke-Panten K,Rojeski M,Pierre S,Kirchhein Y,Jedynasty K

    更新日期:2017-09-01 00:00:00

  • Capillary and venous blood glucose concentrations measured during intravenous insulin and glucose infusion: a comparison of steady and dynamic states.

    abstract:BACKGROUND:Patients undergoing intensive insulin therapy may have blood glucose (BG) samples drawn from arterial, capillary, or venous sources. This study compared capillary and venous BG across a range of glucose concentrations and under conditions of rapid change in BG. METHODS:Following a 10-h fast, 40 adult patien...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章

    doi:10.1089/dia.2009.0023

    authors: Kempe K,Price D,Ellison J,Marhoul J,Morrow L,Win K,Kuschma K,Hompesch M

    更新日期:2009-10-01 00:00:00

  • A dynamic risk measure from continuous glucose monitoring data.

    abstract:BACKGROUND:The quantitative analysis of glucose time-series can greatly help the management of diabetes. In particular, a static nonlinear transformation, which symmetrizes the distribution of glucose levels by bringing them in the so-called risk space, was proposed previously for both self-monitoring blood glucose and...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2011.0006

    authors: Guerra S,Sparacino G,Facchinetti A,Schiavon M,Man CD,Cobelli C

    更新日期:2011-08-01 00:00:00

  • Prevalence of Diabetic Neuropathy in Young Adults with Type 1 Diabetes and the Association with Insulin Pump Therapy.

    abstract:AIMS:The aim was to investigate the prevalence of diabetic sensorimotor polyneuropathy (DSPN) and cardiovascular autonomic neuropathy (CAN) in a Danish population of young adults with type 1 diabetes (T1D) using both established and novel measuring modalities. Furthermore, to investigate the association between continu...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0249

    authors: Christensen MMB,Hommel EE,Jørgensen ME,von Scholten BJ,Fleischer J,Hansen CS

    更新日期:2018-11-21 00:00:00

  • Poor agreement of computerized calculators for mean amplitude of glycemic excursions.

    abstract:BACKGROUND:Glucose variability has been identified as a predictor of hypoglycemia and has been associated with mortality in critically ill patients without diabetes. A popular metric to quantify glucose variability is the mean amplitude of glycemic excursions (MAGE). The "ruler and pencil" approach to calculate MAGE is...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2013.0138

    authors: Sechterberger MK,Luijf YM,Devries JH

    更新日期:2014-02-01 00:00:00

  • Can continuous subcutaneous insulin infusion improve health-related quality of life in patients with Shwachman-Bodian-Diamond syndrome and diabetes?

    abstract::We report the first case of the use of continuous subcutaneous insulin infusion (CSII) in a patient with Shwachman-Bodian-Diamond syndrome (SBDS) and diabetes. An Italian boy received diagnosis of SBDS at the age of 7 months (SBDS gene mutation: c.183-184TA → CT and c.258 + 2 T → C in compound heterozygous). The patie...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2014.0184

    authors: Terlizzi V,Zito E,Mozzillo E,Raia V,Franzese A

    更新日期:2015-01-01 00:00:00

  • Personal glycation factors and calculated HbA1c for diabetes management: Real-world data from the DPV registry.

    abstract::Background Glycated hemoglobin A1c (HbA1c) is a key biomarker in the glycemic management of individuals with diabetes but the relationship with glucose levels can be variable. A recent kinetic model has described a calculated HbA1c (cHbA1c) that is individual-specific. Our aim was to validate the routine clinical use ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2020.0553

    authors: Xu Y,Grimsmann JM,Karges B,Hofer SE,Danne T,Holl RW,Ajjan RA,Dunn TD

    更新日期:2021-01-04 00:00:00

  • The Impact of Insulin Pump Therapy on Glycemic Profiles in Patients with Type 2 Diabetes: Data from the OpT2mise Study.

    abstract:BACKGROUND:The OpT2mise randomized trial was designed to compare the effects of continuous subcutaneous insulin infusion (CSII) and multiple daily injections (MDI) on glucose profiles in patients with type 2 diabetes. RESEARCH DESIGN AND METHODS:Patients with glycated hemoglobin (HbA1c) levels of ≥8% (64 mmol/mol) and...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2015.0159

    authors: Conget I,Castaneda J,Petrovski G,Guerci B,Racault AS,Reznik Y,Cohen O,Runzis S,de Portu S,Aronson R,OpT2mise Study Group.

    更新日期:2016-01-01 00:00:00

  • Active assistance technology reduces glycosylated hemoglobin and weight in individuals with type 2 diabetes: results of a theory-based randomized trial.

    abstract:BACKGROUND:Type 2 diabetes is an individual health challenge requiring ongoing self-management. Remote patient reporting of relevant health parameters and linked automated feedback via mobile telephone have potential to strengthen self-management and improve outcomes. This research involved development and evaluation o...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2013.0056

    authors: Orsama AL,Lähteenmäki J,Harno K,Kulju M,Wintergerst E,Schachner H,Stenger P,Leppänen J,Kaijanranta H,Salaspuro V,Fisher WA

    更新日期:2013-08-01 00:00:00

  • Recovery of β-cell functions with low-dose insulin therapy: study in newly diagnosed type 2 diabetes mellitus patients.

    abstract:AIM:Insulin therapy induces remission in subjects with newly diagnosed type 2 diabetes mellitus (T2DM). This study assessed the insulin and C-peptide levels in newly diagnosed T2DM subjects during low-dose insulin therapy. SUBJECTS AND METHODS:Twenty newly diagnosed, drug-naive, T2DM patients without acute or chronic ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2010.0187

    authors: Bhattacharya S,Ammini AC,Jyotsna V,Gupta N,Dwivedi S

    更新日期:2011-04-01 00:00:00

  • The Effectiveness of Continuous Glucose Monitoring in Patients with Type 2 Diabetes: A Systematic Review of Literature and Meta-analysis.

    abstract:BACKGROUND:Continuous glucose monitoring (CGM) provides glucose trend information that can be used to guide treatment and motivate patients with diabetes. Currently, the evidence on effectiveness of CGM in patients with type 2 diabetes is debatable. We aim to provide a systematic review and meta-analysis to synthesize ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,meta分析

    doi:10.1089/dia.2018.0177

    authors: Park C,Le QA

    更新日期:2018-09-01 00:00:00

  • Attitudes towards insulin pump therapy among adolescents and young people.

    abstract:PURPOSE:This study investigated reasons for the rejection and discontinuation of insulin pump therapy and explored general attitudes towards this mode of therapy among young patients with type 1 diabetes. METHODS:A questionnaire was developed using a focus group of young people with diabetes. It was then used to surve...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2009.0080

    authors: Seereiner S,Neeser K,Weber C,Schreiber K,Habacher W,Rakovac I,Beck P,Schmidt L,Pieber TR

    更新日期:2010-01-01 00:00:00

  • Insulin pumps in young children.

    abstract::Insulin infusion pump therapy has dramatically improved over the past 20 years and can now address some of the specific challenges related to toddlers with diabetes. We discuss both the non-randomized and randomized controlled trials comparing continuous subcutaneous insulin infusion (CSII) and multiple daily injectio...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2009.0182

    authors: Fuld K,Conrad B,Buckingham B,Wilson DM

    更新日期:2010-06-01 00:00:00

  • Increased Time in Range and Fewer Missed Bolus Injections After Introduction of a Smart Connected Insulin Pen.

    abstract:: Background: This observational study investigated whether the connected NovoPen® 6 could influence insulin regimen management and glycemic control in people with type 1 diabetes (T1D) using a basal-bolus insulin regimen and continuous glucose monitoring in a real-world set...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2019.0411

    authors: Adolfsson P,Hartvig NV,Kaas A,Møller JB,Hellman J

    更新日期:2020-10-01 00:00:00

  • Where Do We Stand with Closed-Loop Systems and Their Challenges?

    abstract::Treatments for type 1 diabetes have advanced significantly over recent years. There are now multiple hybrid closed-loop systems commercially available and additional systems are in development. Challenges remain, however. This review outlines the recent advances in closed-loop systems and outlines the remaining challe...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2019.0469

    authors: Jackson M,Castle JR

    更新日期:2020-07-01 00:00:00

  • The design and performance of the exubera pulmonary insulin delivery system.

    abstract::The Exubera system (Pfizer, New York, NY/Nektar Therapeutics, San Carlos, CA) is an integration of five major new technologies: protein formulation, powder processing, powder filling, drug packaging, and delivery device. The product provides a simple interface, where the patient interacts only with the delivery device...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2007.0222

    authors: Harper NJ,Gray S,De Groot J,Parker JM,Sadrzadeh N,Schuler C,Schumacher JD,Seshadri S,Smith AE,Steeno GS,Stevenson CL,Taniere R,Wang M,Bennett DB

    更新日期:2007-06-01 00:00:00

  • "Glucometrics"--assessing the quality of inpatient glucose management.

    abstract:BACKGROUND:For patients with diabetes, the quality of outpatient glycemic control is readily assessed by hemoglobin A1c. In contrast, standardized measures for assessing the quality of blood glucose (BG) management in hospitalized patients are lacking. Because of recent studies demonstrating the benefits of strict glyc...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2006.8.560

    authors: Goldberg PA,Bozzo JE,Thomas PG,Mesmer MM,Sakharova OV,Radford MJ,Inzucchi SE

    更新日期:2006-10-01 00:00:00

  • The emergence of biosimilar insulin preparations--a cause for concern?

    abstract::Several biopharmaceuticals, including insulin and insulin analogs, are, or shortly will be, off-patent, thereby providing an opportunity for companies to attempt to manufacture "copies" commonly referred to as biosimilars and also known as follow-on biologics. Reassurance that such copy biologics are equally safe and ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2012.0105

    authors: Owens DR,Landgraf W,Schmidt A,Bretzel RG,Kuhlmann MK

    更新日期:2012-11-01 00:00:00

  • Validation of the SoloSTAR insulin pen.

    abstract:BACKGROUND:This study was designed to validate the use of SoloSTAR (sanofi-aventis Deutschland GmbH, Frankfurt, Germany), a new disposable pen developed for use with insulin glargine by patients with type 1 or type 2 diabetes. METHODS:This single-center, open-label, single-arm, sequential trial enrolled subjects with ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章

    doi:10.1089/dia.2008.0079

    authors: Schwartz S,Vlajnic A

    更新日期:2008-10-01 00:00:00

  • Patient perceptions of using the OmniPod system compared with conventional insulin pumps in young adults with type 1 diabetes.

    abstract:AIMS:This study evaluated treatment satisfaction, comfort, and function using the wireless OmniPod™ Insulin Management System (Insulet Corp., Bedford, MA) compared with conventional (infusion set) insulin pumps in young adults with type 1 diabetes. RESEARCH DESIGN AND METHODS:Twenty-nine patients (age, 24.0 ± 5.1 year...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2011.0228

    authors: Lebenthal Y,Lazar L,Benzaquen H,Shalitin S,Phillip M

    更新日期:2012-05-01 00:00:00

  • Integrating Continuous Glucose Monitor Data Directly into the Electronic Health Record: Proof of Concept.

    abstract:: Background: Continuous glucose monitoring (CGM) systems are widely and increasingly used in diabetes self-management and in the context of clinic visits. However, access to CGM data during visits can be challenging. Clinic inefficiencies can restrict the time available for...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2019.0377

    authors: Espinoza J,Shah P,Raymond J

    更新日期:2020-08-01 00:00:00