Using multiple measures of glycemia to support individualized diabetes management: recommendations for clinicians, patients, and payers.

Abstract:

:By the year 2030, the diabetes pandemic will likely affect more than 10% of the world's population. The personal, public health, and economic crises implicit in this trend call for decisive action. Yet, escalating dilemmas thwart full realization of current therapies. First, controversial studies, such as the Action to Control Cardiovascular Risk in Diabetes (ACCORD) Trial, have amplified calls to individualize glycated hemoglobin (A1C) targets in the absence of adequate infrastructures for supporting personalized care. Second, costlier medications and technologies addressing more nuanced aspects of metabolic dysfunction are expanding options for diabetes management amidst growing disparities between "affordable" and "best" care. Third, common clinical quandaries, such as discrepancies between A1C and self-monitoring of blood glucose data, as well as misconceptions about long-term glycemic assessment, compound entrenched cycles of inadequate self-care, delayed intervention, and suboptimal glycemic outcomes. Because individual, clinical, and public policy responses to these conflicting forces are based largely on methodologies for glucose measurement, a panel of clinical experts from Europe and North America was convened to reexamine our glucose measuring tools and determine ways in which they can be better applied toward more purposeful processes of glycemic management. Among the main issues addressed were the need for caution in interpreting A1C for individual patients, the role of alternative biomarkers in identifying aspects of glycemic dysregulation not captured by A1C, and the value of using patients' own glucose data to consolidate therapeutic, educational, and behavior-change objectives.

journal_name

Diabetes Technol Ther

authors

Hirsch IB,Amiel SA,Blumer IR,Bode BW,Edelman SV,Seley JJ,Verderese CA,Kilpatrick ES

doi

10.1089/dia.2012.0132

subject

Has Abstract

pub_date

2012-11-01 00:00:00

pages

973-83; quiz 983

issue

11

eissn

1520-9156

issn

1557-8593

journal_volume

14

pub_type

杂志文章,评审
  • A dynamic risk measure from continuous glucose monitoring data.

    abstract:BACKGROUND:The quantitative analysis of glucose time-series can greatly help the management of diabetes. In particular, a static nonlinear transformation, which symmetrizes the distribution of glucose levels by bringing them in the so-called risk space, was proposed previously for both self-monitoring blood glucose and...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2011.0006

    authors: Guerra S,Sparacino G,Facchinetti A,Schiavon M,Man CD,Cobelli C

    更新日期:2011-08-01 00:00:00

  • Mitigating Reductions in Glucose During Exercise on Closed-Loop Insulin Delivery: The Ex-Snacks Study.

    abstract:OBJECTIVE:To assess whether snacking could be used with closed-loop (CL) insulin delivery to avoid exercise-induced reductions in plasma glucose (PG), as well as elevations in PG at the end of exercise. RESEARCH DESIGN AND METHODS:Twelve type 1 diabetes (T1D) subjects (age 13-36 years, duration 10.7 ± 8.4 years, A1c 7...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2016.0311

    authors: Patel NS,Van Name MA,Cengiz E,Carria LR,Tichy EM,Weyman K,Weinzimer SA,Tamborlane WV,Sherr JL

    更新日期:2016-12-01 00:00:00

  • Effect of vildagliptin on glucose and insulin concentrations during a 24-hour period in type 2 diabetes patients with different ranges of baseline hemoglobin A1c levels.

    abstract:BACKGROUND:Currently, it is still unknown whether differences in glycemic control have any effect on glucose and insulin kinetics after vildagliptin administration. The aim of this study was to evaluate the effect of vildagliptin on glucose and insulin concentrations during a 24-h period in type 2 diabetes patients wit...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2013.0020

    authors: González-Ortiz M,Sánchez-Peña MJ,González-Ortiz LJ,Robles-Cervantes JA,García-Ortega YE,Gómez-Gaitán EA,Pérez-Rubio KG,Martínez-Abundis E

    更新日期:2013-07-01 00:00:00

  • Design and Clinical Evaluation of the Interoperable Artificial Pancreas System (iAPS) Smartphone App: Interoperable Components with Modular Design for Progressive Artificial Pancreas Research and Development.

    abstract:BACKGROUND:There is an unmet need for a modular artificial pancreas (AP) system for clinical trials within the existing regulatory framework to further AP research projects from both academia and industry. We designed, developed, and tested the interoperable artificial pancreas system (iAPS) smartphone app that can int...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0278

    authors: Deshpande S,Pinsker JE,Zavitsanou S,Shi D,Tompot R,Church MM,Andre C,Doyle FJ 3rd,Dassau E

    更新日期:2019-01-01 00:00:00

  • Evaluating rate of change as an index of glycemic variability, using continuous glucose monitoring data.

    abstract:BACKGROUND:There is no consensus as to the best method to assess glycemic variability from continuous glucose monitoring (CGM) data. Rate of change has been suggested as a preferred method of assessing glycemic variability, but this assertion has not been validated. METHODS:Forty-eight hours of CGM data were analyzed ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究

    doi:10.1089/dia.2010.0215

    authors: Whitelaw BC,Choudhary P,Hopkins D

    更新日期:2011-06-01 00:00:00

  • Noninvasive continuous glucose monitoring using photoacoustic technology-results from the first 62 subjects.

    abstract:BACKGROUND:Continuous glucose monitoring is a useful tool for the achievement of improved glucose control in patients with diabetes. We tested the ability of a novel noninvasive continuous glucose monitor to track glucose excursions. METHODS:The novel noninvasive Aprise sensor (Glucon Inc., Boulder, CO) utilizes the p...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章

    doi:10.1089/dia.2006.0059

    authors: Weiss R,Yegorchikov Y,Shusterman A,Raz I

    更新日期:2007-02-01 00:00:00

  • Management of patients with diabetes through information technology: tools for monitoring and control of the patients' metabolic behavior.

    abstract:BACKGROUND:The junction of telemedicine home monitoring with multifaceted disease management programs seems nowadays a promising direction to combine the need for an intensive approach to deal with diabetes and the pressure to contain the costs of the interventions. Several projects in the European Union and the United...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2004.6.567

    authors: Bellazzi R,Arcelloni M,Ferrari P,Decata P,Hernando ME,García A,Gazzaruso C,Gómez EJ,Larizza C,Fratino P,Stefanelli M

    更新日期:2004-10-01 00:00:00

  • Validation of physical activity monitors in individuals with diabetes: energy expenditure estimation by the multisensor SenseWear Armband Pro3 and the step counter Omron HJ-720 against indirect calorimetry during walking.

    abstract:BACKGROUND:The purpose of this study is to test the agreement between energy expenditure estimate of the SenseWear(®) Armband Pro3 (SWA) (BodyMedia, Pittsburgh, PA) and the Omron HJ-720 (Omron Healthcare, Kyoto, Japan) step counter with indirect calorimetry (IC) as a gold standard in older individuals with type 1 and t...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2012.0235

    authors: Machač S,Procházka M,Radvanský J,Slabý K

    更新日期:2013-05-01 00:00:00

  • Measurement Performance of Two Continuous Tissue Glucose Monitoring Systems Intended for Replacement of Blood Glucose Monitoring.

    abstract:BACKGROUND:Currently, two systems for continuous tissue glucose monitoring (CGM) (Dexcom® G5 [DG5] and FreeStyle Libre [FL]) are intended to replace blood glucose monitoring (BGM) and, according to manufacturer labeling, are distributed as such in some jurisdictions, including the United States and the European Union. ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0105

    authors: Freckmann G,Link M,Pleus S,Westhoff A,Kamecke U,Haug C

    更新日期:2018-08-01 00:00:00

  • NerveCheck for the Detection of Sensory Loss and Neuropathic Pain in Diabetes.

    abstract:BACKGROUND:Accurate and economic detection of nerve damage in diabetes is key to more widespread diagnosis of patients with diabetic peripheral neuropathy (DPN) and painful diabetic neuropathy. This study examined the diagnostic performance of NerveCheck, an inexpensive ($500) quantitative sensory testing (QST) device....

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2016.0279

    authors: Ponirakis G,Odriozola MN,Odriozola S,Petropoulos IN,Azmi S,Ferdousi M,Fadavi H,Alam U,Marshall A,Jeziorska M,Miro A,Kheyami A,Tavakoli M,Al-Ahmar A,Odriozola MB,Odriozola A,Malik RA

    更新日期:2016-12-01 00:00:00

  • Feasibility of a portable bihormonal closed-loop system to control glucose excursions at home under free-living conditions for 48 hours.

    abstract:BACKGROUND:This study assessed the feasibility of a portable bihormonal closed-loop system at home. SUBJECTS AND METHODS:Sixteen pump-treated patients with type 1 diabetes received 48 h of closed-loop therapy with a telemonitored insulin- and glucagon-delivering closed-loop system and 48 h of patient-managed open-loop...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2013.0166

    authors: van Bon AC,Luijf YM,Koebrugge R,Koops R,Hoekstra JB,DeVries JH

    更新日期:2014-03-01 00:00:00

  • Diabetes and the World Wide Web.

    abstract::The World Wide Web has become remarkably quickly an alternative source of information for patients and their relatives, as well as students and health-care professionals. A whole plethora of websites and Internet-based applications related to diabetes have appeared in recent years. In this column, selected issues surr...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2005.7.225

    authors: Lehmann ED

    更新日期:2005-02-01 00:00:00

  • Usage of the www.2aida.org AIDA diabetes software Website: a pilot study.

    abstract::AIDA is a diabetes-computing program freely available from www.2aida.org on the Web. The software is intended to serve as an educational support tool, and can be used by anyone who has an interest in diabetes, whether they be patients, relatives, health-care professionals, or students. In previous "Diabetes Informatio...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/152091503763816490

    authors: Lehmann ED

    更新日期:2003-01-01 00:00:00

  • Effectiveness of Automated Insulin Management Features of the MiniMed® 640G Sensor-Augmented Insulin Pump.

    abstract:BACKGROUND:Automated insulin management features of the MiniMed® 640G sensor-augmented pump system include suspension in response to predicted low sensor glucose (SG) values ("suspend before low"), suspension in response to existing low SG values ("suspend on low"), and automatic restarting of basal insulin delivery up...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2016.0216

    authors: Zhong A,Choudhary P,McMahon C,Agrawal P,Welsh JB,Cordero TL,Kaufman FR

    更新日期:2016-10-01 00:00:00

  • Efficacy and Tolerability of Exenatide Once Weekly Over 6 Years in Patients with Type 2 Diabetes: An Uncontrolled Open-Label Extension of the DURATION-1 Study.

    abstract:BACKGROUND:Long-term treatment is necessary to slow the progression of type 2 diabetes (T2D). Here, we examined the safety and efficacy of 6 years of treatment with exenatide once weekly (QW) among patients with T2D in the DURATION-1 trial. METHODS:The study enrolled patients aged ≥16 years with T2D treated primarily ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章

    doi:10.1089/dia.2016.0107

    authors: Henry RR,Klein EJ,Han J,Iqbal N

    更新日期:2016-11-01 00:00:00

  • Recovery of β-cell functions with low-dose insulin therapy: study in newly diagnosed type 2 diabetes mellitus patients.

    abstract:AIM:Insulin therapy induces remission in subjects with newly diagnosed type 2 diabetes mellitus (T2DM). This study assessed the insulin and C-peptide levels in newly diagnosed T2DM subjects during low-dose insulin therapy. SUBJECTS AND METHODS:Twenty newly diagnosed, drug-naive, T2DM patients without acute or chronic ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2010.0187

    authors: Bhattacharya S,Ammini AC,Jyotsna V,Gupta N,Dwivedi S

    更新日期:2011-04-01 00:00:00

  • A new imaging and data transmitting device for telemonitoring of diabetic foot syndrome patients.

    abstract:BACKGROUND:Proper healing of ulcers and wounds on the feet of diabetes patients is important in order to prevent amputation. If the wound area reduction during the first 4 weeks of the treatment is not 40% or more, reevaluation of the treatment is necessary. The wound area evaluation is not complicated when the patient...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2011.0004

    authors: Foltynski P,Ladyzynski P,Migalska-Musial K,Sabalinska S,Ciechanowska A,Wojcicki J

    更新日期:2011-08-01 00:00:00

  • Is the masked continuous glucose monitoring system clinically useful for predicting hemoglobin A1C in type 1 diabetes?

    abstract:BACKGROUND:The masked continuous glucose monitoring system (Masked-CGMS) differs from standard CGMSs in three ways: (1) there is no feedback to the user so that no immediate regimen changes can be made; (2) it can only be worn for up to 5 days; and (3) there are no alarms to warn of hyperglycemia or hypoglycemia. Since...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2013.0297

    authors: Duran-Valdez E,Burge MR,Broderick P,Shey L,Valentine V,Schrader R,Schade DS

    更新日期:2014-05-01 00:00:00

  • Real-World Hypoglycemia Avoidance with a Continuous Glucose Monitoring System's Predictive Low Glucose Alert.

    abstract:BACKGROUND:Programmable and fixed auditory and/or vibratory threshold alerts are essential features of real-time continuous glucose monitoring (rtCGM) systems that provide users time to intervene before the onset of clinical hypoglycemia or hyperglycemia. A sixth-generation rtCGM system from Dexcom, Inc. (G6) includes ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0359

    authors: Puhr S,Derdzinski M,Welsh JB,Parker AS,Walker T,Price DA

    更新日期:2019-04-01 00:00:00

  • Limitations of the HOMA-B score for assessment of beta-cell functionality in interventional trials-results from the PIOglim study.

    abstract:BACKGROUND:Drugs with unspecific stimulating effects on beta-cell secretion increase the homeostasis model assessment (HOMA)-B score, indicating improved beta-cell "function." We investigated whether the beta-cell protection provided by adding pioglitazone (PIO) to glimepiride (GLIM) in comparison to up-titrating the G...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2010.0019

    authors: Pfützner A,Derwahl M,Jacob S,Hohberg C,Blümner E,Lehmann U,Fuchs W,Forst T

    更新日期:2010-08-01 00:00:00

  • RETRACTED: No deleterious effect of lockdown due to COVID-19 pandemic on glycaemic control, measured by glucose monitoring, in adults with type 1 diabetes.

    abstract::The Editor of Diabetes Technology & Therapeutics is officially retracting the article entitled, "No Deleterious Effect of Lockdown Due to COVID-19 Pandemic on Glycaemic Control, Measured by Glucose Monitoring, in Adults with Type 1 Diabetes," by Beato-Vibora PI. Diabetes Technol Ther 2020; epub DOI: 10.1089/dia.2020.0...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,收录出版

    doi:10.1089/dia.2020.0184

    authors: Beato-Víbora PI

    更新日期:2020-05-12 00:00:00

  • Frequency of the dawn phenomenon in type 2 diabetes: implications for diabetes therapy.

    abstract::This study was designed to assess the frequency of the dawn phenomenon in patients with type 2 diabetes. A secondary aim was to examine the influence of varying treatment regimens on the frequency of the dawn phenomenon. The dawn phenomenon was defined as a rise in plasma glucose levels of > or = 0.5 mmol/L (10 mg/dL)...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章

    doi:10.1089/152091502320798213

    authors: Carroll MF,Hardy KJ,Burge MR,Schade DS

    更新日期:2002-01-01 00:00:00

  • The Impact of Short-Term Professional Continuous Glucose Monitoring on Glycemic Control Via Lifestyle Improvement.

    abstract:BACKGROUND:The efficacy of short-term professional continuous glucose monitoring (CGM) for glycemic control in patients with diabetes remains unclear. METHODS:We performed a 3-month study to evaluate the benefits of CGM in 64 patients. RESULTS:The overall glycemic control of patients who underwent CGM improved signif...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0164

    authors: Shibusawa R,Yamada E,Okada S,Nakajima Y,Bastie CC,Yamada M

    更新日期:2018-09-01 00:00:00

  • Patients' perceptions of subcutaneous insulin in the OPTIMIZE study: a multicenter follow-up study.

    abstract:BACKGROUND:The Optimizing Control in Diabetes (OPTIMIZE) survey was conducted to understand the patients' perspective to achieving good glycemic control and to determine how patients' perceptions of insulin may affect their decisions to initiate or intensify their insulin therapy. METHODS:A total of 1,444 subjects wit...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究

    doi:10.1089/dia.2008.0249

    authors: Cefalu WT,Mathieu C,Davidson J,Freemantle N,Gough S,Canovatchel W,OPTIMIZE Coalition.

    更新日期:2008-02-01 00:00:00

  • High Glucose Variability in Hospitalized Patients with Type 1 Diabetes Mellitus.

    abstract:BACKGROUND:Glucose variability (GV) has been increasingly (or more extensively) studied in patients with type 1 diabetes (T1D) in the ambulatory setting; limited data exist on GV in hospitalized patients with T1D. MATERIALS AND METHODS:Retrospective single center cohort study, we analyzed in-hospital glucose measureme...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2017.0107

    authors: Dadlani V,Tamhane SU,Sun A,Sharma A,Delivanis DA,Thapa P,Carter RE,Kudva YC

    更新日期:2017-10-01 00:00:00

  • Advanced meter features improve postprandial and paired self-monitoring of blood glucose in individuals with diabetes: results of the Actions with the CONTOUR Blood Glucose Meter and Behaviors in Frequent Testers (ACT) study.

    abstract:BACKGROUND:This study evaluated whether education and use of the advanced meter features of the CONTOUR(®) (Bayer HealthCare LLC, Diabetes Care, Tarrytown, NY) blood glucose monitoring system (BGMS) affect the frequency and pattern of blood glucose testing in insulin-using subjects with diabetes who routinely perform s...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1089/dia.2012.0051

    authors: Bergenstal RM,Bode BW,Tamler R,Trence DL,Stenger P,Schachner HC,Fullam J,Pardo S,Kohut T,Fisher WA

    更新日期:2012-10-01 00:00:00

  • Point accuracy of interstitial continuous glucose monitoring during exercise in type 1 diabetes.

    abstract:BACKGROUND:Previous studies of aerobic exercise have found lower sensor accuracy during exercise. Whether or not resistance exercise would also be associated with lower sensor accuracy has not yet been examined. This study sought to investigate the accuracy of continuous glucose monitoring sensor values at rest, during...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2012.0182

    authors: Yardley JE,Sigal RJ,Kenny GP,Riddell MC,Lovblom LE,Perkins BA

    更新日期:2013-01-01 00:00:00

  • Integrating Continuous Glucose Monitor Data Directly into the Electronic Health Record: Proof of Concept.

    abstract:: Background: Continuous glucose monitoring (CGM) systems are widely and increasingly used in diabetes self-management and in the context of clinic visits. However, access to CGM data during visits can be challenging. Clinic inefficiencies can restrict the time available for...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2019.0377

    authors: Espinoza J,Shah P,Raymond J

    更新日期:2020-08-01 00:00:00

  • Nocturnal Glucose Metabolism in Type 1 Diabetes: A Study Comparing Single Versus Dual Tracer Approaches.

    abstract:BACKGROUND:Understanding the effect size, variability, and underlying physiology of the dawn phenomenon is important for next-generation closed-loop control algorithms for type 1 diabetes (T1D). SUBJECTS AND METHODS:We used an iterative protocol design to study 16 subjects with T1D on individualized insulin pump thera...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2015.0011

    authors: Mallad A,Hinshaw L,Dalla Man C,Cobelli C,Basu R,Lingineni R,Carter RE,Kudva YC,Basu A

    更新日期:2015-08-01 00:00:00

  • Clinical studies on chromium picolinate supplementation in diabetes mellitus--a review.

    abstract::Chromium (Cr) picolinate (CrPic) is a widely used nutritional supplement for optimal insulin function. A relationship among Cr status, diabetes, and associated pathologies has been established. Virtually all trials using CrPic supplementation for subjects with diabetes have demonstrated beneficial effects. Thirteen of...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2006.8.677

    authors: Broadhurst CL,Domenico P

    更新日期:2006-12-01 00:00:00