Frequency of the dawn phenomenon in type 2 diabetes: implications for diabetes therapy.

Abstract:

:This study was designed to assess the frequency of the dawn phenomenon in patients with type 2 diabetes. A secondary aim was to examine the influence of varying treatment regimens on the frequency of the dawn phenomenon. The dawn phenomenon was defined as a rise in plasma glucose levels of > or = 0.5 mmol/L (10 mg/dL) between 0500 and 0900 h occurring after a growth hormone surge of > or = 5 microg/L. Sixteen subjects (six men, 10 women) with type 2 diabetes were studied overnight on their current mode of therapy in the General Clinical Research Center. Additionally, six of these subjects were restudied in random order after each of the following three therapeutic regimens: (1) 6 weeks of glipizide, (2) 6 weeks of bedtime NPH insulin, and (3) 3 days of intensive insulin therapy with multiple injections of regular insulin followed by assessment during overnight intravenous infusion of insulin. Thus, a total of 34 overnight studies were performed under various treatment conditions to provide an approximate frequency of the dawn phenomenon in type 2 diabetes. Blood was drawn every 30 min between midnight and 0800 h for measurement of glucose, insulin, C-peptide, and growth hormone levels. Additional counterregulatory hormone levels were determined during 24 of the studies, and the integrity of growth hormone secretion in response to insulin-induced hypoglycemia was assessed in 12 of the 16 patients. The subjects were aged 51 +/- 15 years with a body mass index of 31 +/- 5 kg/m(2) and a mean glycosylated hemoglobin of 8.1 +/- 1.2%. The dawn phenomenon occurred in only one of 34 (3%) studies. Moreover, the four different treatment regimens did not affect the frequency of occurrence of the dawn phenomenon. Ten of the 12 patients tested failed to secrete growth hormone in response to insulin-induced hypoglycemia. These data suggest that the dawn phenomenon is unusual in type 2 diabetes. Previously reported high prevalence rates in studies using similar sample size may be attributable to a Biostator-induced artifact. Decisions regarding therapies for type 2 diabetes should not be based on the assumption that the dawn phenomenon routinely causes early morning hyperglycemia.

journal_name

Diabetes Technol Ther

authors

Carroll MF,Hardy KJ,Burge MR,Schade DS

doi

10.1089/152091502320798213

keywords:

subject

Has Abstract

pub_date

2002-01-01 00:00:00

pages

595-605

issue

5

eissn

1520-9156

issn

1557-8593

journal_volume

4

pub_type

临床试验,杂志文章
  • Clinical studies on chromium picolinate supplementation in diabetes mellitus--a review.

    abstract::Chromium (Cr) picolinate (CrPic) is a widely used nutritional supplement for optimal insulin function. A relationship among Cr status, diabetes, and associated pathologies has been established. Virtually all trials using CrPic supplementation for subjects with diabetes have demonstrated beneficial effects. Thirteen of...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2006.8.677

    authors: Broadhurst CL,Domenico P

    更新日期:2006-12-01 00:00:00

  • Lasers and diabetic retinopathy: the art of gentle destruction.

    abstract::Laser retinal photocoagulation represents the primary therapy for the potentially blinding manifestations of diabetic retinopathy. Advances in laser therapy for diabetic eye disease have arisen from the convergence of laser technology and clinical ophthalmology. In this review, the basis of laser therapy in diabetic r...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/152091599317396

    authors: Petrovic V,Bhisitkul RB

    更新日期:1999-07-01 00:00:00

  • Estimated Lifetime Economic Burden of Type 1 Diabetes.

    abstract:: Background: The financial strain of type 1 diabetes on the United States health care system, patients, and employers underscores the importance of developing novel treatments for the disease. This study estimated the lifetime economic burden attributable to type 1 diabetes...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2019.0398

    authors: Sussman M,Benner J,Haller MJ,Rewers M,Griffiths R

    更新日期:2020-02-01 00:00:00

  • Obesity and diabetes: newer concepts in imaging.

    abstract::Quantifying body fat is currently an area of active research. Recent studies have shown that the quantity and location of fat in different compartments have varying clinical significance. This information can now be obtained from computed tomography (CT) or magnetic resonance (MR), and it can inform clinical decision ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2013.0039

    authors: Garg K,Chang S,Scherzinger A

    更新日期:2013-05-01 00:00:00

  • Proteomic identification of human urinary biomarkers in diabetes mellitus type 2.

    abstract:BACKGROUND:During the proteomic era, one of the most rapidly growing areas in biomedical research is biomarker discovery, particularly using proteomic technologies. The urinary proteome is known to be a valuable field of study and has become one of the most attractive subdisciplines in clinical proteomics for human dis...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2010.0078

    authors: Riaz S,Alam SS,Srai SK,Skinner V,Riaz A,Akhtar MW

    更新日期:2010-12-01 00:00:00

  • Magnitude and determinants of ocular morbidities among persons with diabetes in a project in Ahmedabad, India.

    abstract:BACKGROUND:Visual disabilities due to diabetes are on the rise, especially in urban areas of developing countries. Proper health planning will need evidence-based information. STUDY DESIGN AND METHODS:We estimated the prevalence and identified the determinants of eye complications among persons with diabetes screened ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2009.0033

    authors: Vyas U,Khandekar R,Trivedi N,Desai T,Danayak P

    更新日期:2009-09-01 00:00:00

  • Glucose variability indices in type 1 diabetes: parsimonious set of indices revealed by sparse principal component analysis.

    abstract:BACKGROUND:Continuous glucose monitoring (CGM) time-series are often analyzed, retrospectively, to investigate glucose variability (GV), a risk factor for the development of complications in type 1 diabetes (T1D). In the literature, several tens of different indices for GV quantification have been proposed, but many of...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,meta分析

    doi:10.1089/dia.2013.0252

    authors: Fabris C,Facchinetti A,Sparacino G,Zanon M,Guerra S,Maran A,Cobelli C

    更新日期:2014-10-01 00:00:00

  • Clinical Practice Recommendations on the Routine Use of Eversense, the First Long-Term Implantable Continuous Glucose Monitoring System.

    abstract:: Background: The use of real-time continuous glucose monitoring (rtCGM) systems has proved to positively impact the management of type 1 diabetes with the potential to lower HbA1c, reduce frequency and time spent in hypoglycemia, and lower glycemic variability. Nevertheless...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0397

    authors: Deiss D,Szadkowska A,Gordon D,Mallipedhi A,Schütz-Fuhrmann I,Aguilera E,Ringsell C,De Block C,Irace C

    更新日期:2019-05-01 00:00:00

  • Description and preliminary evaluation of a Multiagent Intelligent Dosing System (MAIDS) to manage combination insulin-oral agent therapy in type 2 diabetes.

    abstract:BACKGROUND:Computer decision support systems are potentially effective methods for adjusting insulin, but current models do not take into account simultaneous changes of more than one agent. We describe the development of the Multiagent Intelligent Dosing System (MAIDS, Dimensional Dosing Systems, Wexford, PA) for pred...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2005.7.937

    authors: Cook CB,McMichael JP,Dunbar VG,Lieberman R

    更新日期:2005-12-01 00:00:00

  • Safety Evaluation of the MiniMed 670G System in Children 7-13 Years of Age with Type 1 Diabetes.

    abstract:OBJECTIVE:To evaluate the safety of in-home use of the MiniMed™ 670G system with SmartGuard™ technology in children with type 1 diabetes (T1D). METHODS:Participants (N = 105, ages 7-13 years, mean age 10.8 ± 1.8 years) were enrolled at nine centers (eight in the United States and one in Israel) and completed a 2-week ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0264

    authors: Forlenza GP,Pinhas-Hamiel O,Liljenquist DR,Shulman DI,Bailey TS,Bode BW,Wood MA,Buckingham BA,Kaiserman KB,Shin J,Huang S,Lee SW,Kaufman FR

    更新日期:2019-01-01 00:00:00

  • Biphasic insulin aspart 30 in insulin-naive people with type 2 diabetes in non-western nations: results from a regional comparative multinational observational study (A(1)chieve).

    abstract:BACKGROUND:A1chieve(®) (Novo Nordisk A/S, Bagsværd, Denmark) was a prospective, multicenter, noninterventional study in 66,726 people with type 2 diabetes mellitus (T2DM) in 28 countries beginning biphasic insulin aspart 30 (aspart premix), insulin detemir, or insulin aspart in routine clinical care. SUBJECTS AND METH...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究

    doi:10.1089/dia.2013.0074

    authors: Shah S,Yang W,Hasan MI,Malek R,Molskov Bech O,Home P

    更新日期:2013-11-01 00:00:00

  • A recent survey confirms the efficacy and the safety of implanted insulin pumps during long-term use in poorly controlled type 1 diabetes patients.

    abstract:BACKGROUND:This article reports a prolonged trial with insulin pumps implanted in patients with type 1 diabetes showing poor glucose control and a high rate of complications. METHODS:We reviewed data from 181 patients undergoing implanted insulin pump therapy. Analysis included hemoglobin A1c (HbA1c) values, body weig...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2010.0209

    authors: Schaepelynck P,Renard E,Jeandidier N,Hanaire H,Fermon C,Rudoni S,Catargi B,Riveline JP,Guerci B,Millot L,Martin JF,Sola A,EVADIAC Group.

    更新日期:2011-06-01 00:00:00

  • Measurement Performance of Two Continuous Tissue Glucose Monitoring Systems Intended for Replacement of Blood Glucose Monitoring.

    abstract:BACKGROUND:Currently, two systems for continuous tissue glucose monitoring (CGM) (Dexcom® G5 [DG5] and FreeStyle Libre [FL]) are intended to replace blood glucose monitoring (BGM) and, according to manufacturer labeling, are distributed as such in some jurisdictions, including the United States and the European Union. ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0105

    authors: Freckmann G,Link M,Pleus S,Westhoff A,Kamecke U,Haug C

    更新日期:2018-08-01 00:00:00

  • "Glucometrics"--assessing the quality of inpatient glucose management.

    abstract:BACKGROUND:For patients with diabetes, the quality of outpatient glycemic control is readily assessed by hemoglobin A1c. In contrast, standardized measures for assessing the quality of blood glucose (BG) management in hospitalized patients are lacking. Because of recent studies demonstrating the benefits of strict glyc...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2006.8.560

    authors: Goldberg PA,Bozzo JE,Thomas PG,Mesmer MM,Sakharova OV,Radford MJ,Inzucchi SE

    更新日期:2006-10-01 00:00:00

  • Evaluating rate of change as an index of glycemic variability, using continuous glucose monitoring data.

    abstract:BACKGROUND:There is no consensus as to the best method to assess glycemic variability from continuous glucose monitoring (CGM) data. Rate of change has been suggested as a preferred method of assessing glycemic variability, but this assertion has not been validated. METHODS:Forty-eight hours of CGM data were analyzed ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究

    doi:10.1089/dia.2010.0215

    authors: Whitelaw BC,Choudhary P,Hopkins D

    更新日期:2011-06-01 00:00:00

  • A Prospective Multicenter Evaluation of the Accuracy of a Novel Implanted Continuous Glucose Sensor: PRECISE II.

    abstract:BACKGROUND:Persistent use of real-time continuous glucose monitoring (CGM) improves diabetes control in individuals with type 1 diabetes (T1D) and type 2 diabetes (T2D). METHODS:PRECISE II was a nonrandomized, blinded, prospective, single-arm, multicenter study that evaluated the accuracy and safety of the implantable...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究

    doi:10.1089/dia.2017.0142

    authors: Christiansen MP,Klaff LJ,Brazg R,Chang AR,Levy CJ,Lam D,Denham DS,Atiee G,Bode BW,Walters SJ,Kelley L,Bailey TS

    更新日期:2018-03-01 00:00:00

  • Peripheral leptin levels in narcoleptic patients.

    abstract:BACKGROUND:Narcolepsy is a severe sleep disorder that in most patients is characterized by the deficiency of central orexin. Clinically, narcolepsy is associated with obesity. Currently, there is a literature controversy about the potential alteration of leptin levels in narcoleptic patients. Theoretically, diminished ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2006.0037

    authors: Dahmen N,Engel A,Helfrich J,Manderscheid N,Löbig M,Forst T,Pfützner A,Tonn P

    更新日期:2007-08-01 00:00:00

  • Role of Continuous Glucose Monitoring in Clinical Trials: Recommendations on Reporting.

    abstract::Thanks to significant improvements in the precision, accuracy, and usability of continuous glucose monitoring (CGM), its relevance in both ambulatory diabetes care and clinical research is increasing. In this study, we address the latter perspective and derive provisional reporting recommendations. CGM systems have be...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2017.0054

    authors: Schnell O,Barnard K,Bergenstal R,Bosi E,Garg S,Guerci B,Haak T,Hirsch IB,Ji L,Joshi SR,Kamp M,Laffel L,Mathieu C,Polonsky WH,Snoek F,Home P

    更新日期:2017-07-01 00:00:00

  • Oral Semaglutide: A Review of the First Oral Glucagon-Like Peptide 1 Receptor Agonist.

    abstract::Glucagon-like peptide 1 receptor agonists (GLP-1 RAs) are highly effective at lowering hemoglobin A1c (HbA1c) and facilitating weight loss. Four agents in the GLP-1 RA class, albiglutide, liraglutide, dulaglutide, and semaglutide, also have cardioprotective effects. However, subcutaneous administration of these agents...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2019.0185

    authors: Bucheit JD,Pamulapati LG,Carter N,Malloy K,Dixon DL,Sisson EM

    更新日期:2020-01-01 00:00:00

  • Systemic effects of shock and resuscitation monitored by visible hyperspectral imaging.

    abstract::Hyperspectral imaging (HSI) has been useful in monitoring several medical conditions, which to date have generally involved local changes in skin oxygenation of isolated regions of interest such as skin flaps or small burns. Here, by contrast, we present a study in which HSI was used to assess the local cutaneous mani...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/152091503322527058

    authors: Gillies R,Freeman JE,Cancio LC,Brand D,Hopmeier M,Mansfield JR

    更新日期:2003-01-01 00:00:00

  • The effect of local subcutaneous delivery of vascular endothelial growth factor on the function of a chronically implanted amperometric glucose sensor.

    abstract::The foreign body capsule that forms around implanted devices such as glucose sensors is hypovascular and has limited permeability to glucose. Such a capsule may function better if well vascularized. We hypothesized that capsular vascularization achieved by local release of vascular endothelial growth factor (VEGF) wou...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/152091504773731320

    authors: Ward WK,Wood MD,Casey HM,Quinn MJ,Federiuk IF

    更新日期:2004-04-01 00:00:00

  • Effectiveness of Automated Insulin Management Features of the MiniMed® 640G Sensor-Augmented Insulin Pump.

    abstract:BACKGROUND:Automated insulin management features of the MiniMed® 640G sensor-augmented pump system include suspension in response to predicted low sensor glucose (SG) values ("suspend before low"), suspension in response to existing low SG values ("suspend on low"), and automatic restarting of basal insulin delivery up...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2016.0216

    authors: Zhong A,Choudhary P,McMahon C,Agrawal P,Welsh JB,Cordero TL,Kaufman FR

    更新日期:2016-10-01 00:00:00

  • Behavioral Patterns and Associations with Glucose Control During 12-Week Randomized Free-Living Clinical Trial of Day and Night Hybrid Closed-Loop Insulin Delivery in Adults with Type 1 Diabetes.

    abstract:OBJECTIVES:We evaluated patterns of meal intake, insulin bolus delivery, and fingerstick glucose measurements during hybrid closed-loop and sensor-augmented pump (SAP) therapy, including associations with glucose control. METHODS:Data were retrospectively analyzed from pump-treated adults with type 1 diabetes who unde...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2016.0307

    authors: Emami A,Willinska ME,Thabit H,Leelarathna L,Hartnell S,Dellweg S,Benesch C,Mader JK,Holzer M,Kojzar H,Pieber TR,Arnolds S,Evans ML,Hovorka R

    更新日期:2017-07-01 00:00:00

  • Intervention trials for prevention of metabolic syndrome and type 2 diabetes: focus on Asian Indians.

    abstract::Prevalence of diabetes continues to increase in urban areas, and escalation is discernible in semi-urban and rural areas. It is reported to affect Asian Indians a decade earlier compared with other populations, and complications (e.g., nephropathy) occur earlier and are severe and more prevalent than in other races. B...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2013.0373

    authors: Shrivastava U,Misra A

    更新日期:2014-08-01 00:00:00

  • Family perceptions of insulin pump adverse events in children and adolescents.

    abstract:BACKGROUND:Insulin pumps (for continuous subcutaneous insulin infusion [CSII]) are used widely in type 1 diabetes mellitus. Although there has been considerable study of outcomes, there are few recent data on CSII-associated adverse events and no data on family perceptions of adverse events and their confidence in deal...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2013.0315

    authors: Wheeler BJ,Donaghue KC,Heels K,Ambler GR

    更新日期:2014-04-01 00:00:00

  • The Impact of Insulin Pump Therapy on Glycemic Profiles in Patients with Type 2 Diabetes: Data from the OpT2mise Study.

    abstract:BACKGROUND:The OpT2mise randomized trial was designed to compare the effects of continuous subcutaneous insulin infusion (CSII) and multiple daily injections (MDI) on glucose profiles in patients with type 2 diabetes. RESEARCH DESIGN AND METHODS:Patients with glycated hemoglobin (HbA1c) levels of ≥8% (64 mmol/mol) and...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2015.0159

    authors: Conget I,Castaneda J,Petrovski G,Guerci B,Racault AS,Reznik Y,Cohen O,Runzis S,de Portu S,Aronson R,OpT2mise Study Group.

    更新日期:2016-01-01 00:00:00

  • Prevalence of Diabetic Neuropathy in Young Adults with Type 1 Diabetes and the Association with Insulin Pump Therapy.

    abstract:AIMS:The aim was to investigate the prevalence of diabetic sensorimotor polyneuropathy (DSPN) and cardiovascular autonomic neuropathy (CAN) in a Danish population of young adults with type 1 diabetes (T1D) using both established and novel measuring modalities. Furthermore, to investigate the association between continu...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0249

    authors: Christensen MMB,Hommel EE,Jørgensen ME,von Scholten BJ,Fleischer J,Hansen CS

    更新日期:2018-11-21 00:00:00

  • System Accuracy Evaluation of Different Blood Glucose Monitoring Systems Following ISO 15197:2013 by Using Two Different Comparison Methods.

    abstract:BACKGROUND:Adherence to established standards (e.g., International Organization for Standardization [ISO] 15197) is important to ensure comparable and sufficient accuracy of systems for self-monitoring of blood glucose (SMBG). Accuracy evaluation was performed for different SMBG systems available in Europe with three r...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2015.0085

    authors: Freckmann G,Link M,Schmid C,Pleus S,Baumstark A,Haug C

    更新日期:2015-09-01 00:00:00

  • Daily glucose profiles in Japanese people with normal glucose tolerance as assessed by continuous glucose monitoring.

    abstract:BACKGROUND:Little information is available regarding glucose fluctuations in postprandial states and during the oral glucose tolerance test (OGTT) in Japanese people with normal glucose tolerance (NGT). METHODS:Glucose profiles of 27 Japanese people were measured for 4 days by using continuous glucose monitoring. A 75...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2008.0083

    authors: Tsujino D,Nishimura R,Taki K,Miyashita Y,Morimoto A,Tajima N

    更新日期:2009-07-01 00:00:00

  • Evaluation of Blood Glucose Meter Efficacy in an Antenatal Diabetes Clinic.

    abstract:BACKGROUND:The optimal treatment of diabetes in pregnancy requires accurate measurement of blood glucose levels, in order to minimize adverse outcomes for both mother and neonate. Self-monitoring of blood glucose is routinely used to measure glycemic control and to assess whether treatment targets are being met; howeve...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,收录出版

    doi:10.1089/dia.2015.0104

    authors: McGrath RT,Donnelly VC,Glastras SJ,Preda VA,Sheriff N,Ward P,Hocking SL,Fulcher GR

    更新日期:2016-02-01 00:00:00