Magnitude and determinants of ocular morbidities among persons with diabetes in a project in Ahmedabad, India.

Abstract:

BACKGROUND:Visual disabilities due to diabetes are on the rise, especially in urban areas of developing countries. Proper health planning will need evidence-based information. STUDY DESIGN AND METHODS:We estimated the prevalence and identified the determinants of eye complications among persons with diabetes screened in Ahmedabad, India, during 2007-2008. This was a review of the data from a health institution-based project. Physicians collected information on diabetes, and ophthalmologists examined the patients for visual acuity, diabetic retinopathy (DR), glaucoma, and cataracts. World Health Organization-recommended grading of DR was used. Frequencies, prevalence, and 95% confidence interval (CI) values were calculated. RESULTS:Of 40,919 persons who we examined for diabetes, 9,246 (66.6%) persons knew that they had diabetes, whereas 4,641 (33.4%) persons were detected with diabetes for the first time. The prevalence of DR, early cataract, and glaucoma among those who knew that they had diabetes was 14.6% (95% CI 13.9-15.3), 44.4% (95% CI 43.4-45.4), and 5.4% (95% CI 4.9-5.9), respectively. The prevalence of DR among persons with diabetes (new and old) was 10.1% (95% CI 9.6-10.6). Although poor vision was positively associated with DR (chi2 = 706), 40% of those with DR had vision better than 20/60. Male sex (odds ratio [OR] = 1.31), longer duration of diabetes (chi2 = 1,808), hypertension (OR = 1.13), good sugar control (OR = 0.09), and nephropathy (OR = 2.16) were the factors associated with DR. Regression analysis suggested that longer duration of diabetes and poor control of diabetes were the predictors of DR. CONCLUSIONS:The prevalence of DR was low. Long duration of diabetes, poor control of blood sugar, presence of nephropathy, and hypertension were associated with DR. Good vision could mislead about the severity of DR.

journal_name

Diabetes Technol Ther

authors

Vyas U,Khandekar R,Trivedi N,Desai T,Danayak P

doi

10.1089/dia.2009.0033

subject

Has Abstract

pub_date

2009-09-01 00:00:00

pages

601-7

issue

9

eissn

1520-9156

issn

1557-8593

journal_volume

11

pub_type

杂志文章
  • RETRACTED: No deleterious effect of lockdown due to COVID-19 pandemic on glycaemic control, measured by glucose monitoring, in adults with type 1 diabetes.

    abstract::The Editor of Diabetes Technology & Therapeutics is officially retracting the article entitled, "No Deleterious Effect of Lockdown Due to COVID-19 Pandemic on Glycaemic Control, Measured by Glucose Monitoring, in Adults with Type 1 Diabetes," by Beato-Vibora PI. Diabetes Technol Ther 2020; epub DOI: 10.1089/dia.2020.0...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,收录出版

    doi:10.1089/dia.2020.0184

    authors: Beato-Víbora PI

    更新日期:2020-05-12 00:00:00

  • Validation of the SoloSTAR insulin pen.

    abstract:BACKGROUND:This study was designed to validate the use of SoloSTAR (sanofi-aventis Deutschland GmbH, Frankfurt, Germany), a new disposable pen developed for use with insulin glargine by patients with type 1 or type 2 diabetes. METHODS:This single-center, open-label, single-arm, sequential trial enrolled subjects with ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章

    doi:10.1089/dia.2008.0079

    authors: Schwartz S,Vlajnic A

    更新日期:2008-10-01 00:00:00

  • Interactive educational diabetes/insulin tutorial at www.2aida.info.

    abstract::The World Wide Web now hosts a multitude of diabetes educational materials in various formats. Of particular interest is the diabetes/insulin tutorial available at the AIDA Website (accessible directly at: www.2aida.info). The tutorial combines textual or "static" information with an interactive diabetes simulator-AID...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2006.8.126

    authors: Reed K,Lehmann ED

    更新日期:2006-02-01 00:00:00

  • The Value of Automated Diabetic Retinopathy Screening with the EyeArt System: A Study of More Than 100,000 Consecutive Encounters from People with Diabetes.

    abstract:: Background: Current manual diabetic retinopathy (DR) screening using eye care experts cannot scale to screen the growing population of diabetes patients who are at risk for vision loss. EyeArt system is an automated, cloud-based artificial intelligence (AI) eye screening t...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2019.0164

    authors: Bhaskaranand M,Ramachandra C,Bhat S,Cuadros J,Nittala MG,Sadda SR,Solanki K

    更新日期:2019-11-01 00:00:00

  • Nocturnal continuous glucose monitoring: accuracy and reliability of hypoglycemia detection in patients with type 1 diabetes at high risk of severe hypoglycemia.

    abstract:BACKGROUND:A reliable method to detect biochemical nocturnal hypoglycemia is highly needed, especially in patients with recurrent severe hypoglycemia. We evaluated reliability of nocturnal continuous glucose monitoring (CGM) in patients with type 1 diabetes at high risk of severe hypoglycemia. PATIENTS AND METHODS:Sev...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1089/dia.2013.0004

    authors: Bay C,Kristensen PL,Pedersen-Bjergaard U,Tarnow L,Thorsteinsson B

    更新日期:2013-05-01 00:00:00

  • Accuracy of glycemic measurements in the critically ill.

    abstract:BACKGROUND:Recent evidence emphasizes the importance of maintaining normoglycemia in critically ill patients to reduce morbidity and mortality. Different analytical methods of varying accuracy exist for obtaining and measuring blood glucose in critically ill patients. The purpose of this study was to determine if there...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2008.0263

    authors: Slater-MacLean L,Cembrowski G,Chin D,Shalapay C,Binette T,Hegadoren K,Newburn-Cook C

    更新日期:2008-06-01 00:00:00

  • Association of DRD3, COMT, and SLC6A4 Gene Polymorphisms with Type 2 Diabetes in Southern Chinese: A Hospital-Based Case-Control Study.

    abstract:AIM:The aim of this study was to assess the associations of six single nucleotide polymorphisms (SNPs) of three genes (DRD3, COMT, and SCL6A4) with type 2 diabetes mellitus (T2DM) in Southern Chinese. SUBJECTS AND METHODS:Five hundred ninety-five cases with T2DM and 725 healthy controls of Han origin were recruited fr...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2014.0344

    authors: Xiu L,Lin M,Liu W,Kong D,Liu Z,Zhang Y,Ouyang P,Liang Y,Zhong S,Chen C,Jin X,Fan X,Qin J,Zhao X,Rao S,Ding Y

    更新日期:2015-08-01 00:00:00

  • Integrating Continuous Glucose Monitor Data Directly into the Electronic Health Record: Proof of Concept.

    abstract:: Background: Continuous glucose monitoring (CGM) systems are widely and increasingly used in diabetes self-management and in the context of clinic visits. However, access to CGM data during visits can be challenging. Clinic inefficiencies can restrict the time available for...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2019.0377

    authors: Espinoza J,Shah P,Raymond J

    更新日期:2020-08-01 00:00:00

  • Efficacy and Safety of SGLT2 Inhibitors in Type 1 Diabetes After the Introduction of an Off-Label Use Protocol for Clinical Practice.

    abstract:: Aims: We evaluated the real-life efficacy and safety of empagliflozin in combination with optimized insulin therapy in patients with type 1 diabetes (T1D). Methods: This was a prospective study, including 27 patients with T1D t...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2019.0316

    authors: Bayona Cebada A,Nattero-Chávez L,Alonso Díaz S,Escobar-Morreale HF,Luque-Ramírez M

    更新日期:2020-03-01 00:00:00

  • Use of an internet-based telemedicine system to manage underserved women with gestational diabetes mellitus.

    abstract:BACKGROUND:Internet technology has been proven to be a successful tool for the management of patients with multiple medical conditions. The purpose of this study was to demonstrate the feasibility of monitoring glucose control in indigent women with gestational diabetes mellitus (GDM) over the Internet. METHODS:Women ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2006.0034

    authors: Homko CJ,Santamore WP,Whiteman V,Bower M,Berger P,Geifman-Holtzman O,Bove AA

    更新日期:2007-06-01 00:00:00

  • Clinical studies on chromium picolinate supplementation in diabetes mellitus--a review.

    abstract::Chromium (Cr) picolinate (CrPic) is a widely used nutritional supplement for optimal insulin function. A relationship among Cr status, diabetes, and associated pathologies has been established. Virtually all trials using CrPic supplementation for subjects with diabetes have demonstrated beneficial effects. Thirteen of...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2006.8.677

    authors: Broadhurst CL,Domenico P

    更新日期:2006-12-01 00:00:00

  • A Prospective Multicenter Evaluation of the Accuracy of a Novel Implanted Continuous Glucose Sensor: PRECISE II.

    abstract:BACKGROUND:Persistent use of real-time continuous glucose monitoring (CGM) improves diabetes control in individuals with type 1 diabetes (T1D) and type 2 diabetes (T2D). METHODS:PRECISE II was a nonrandomized, blinded, prospective, single-arm, multicenter study that evaluated the accuracy and safety of the implantable...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究

    doi:10.1089/dia.2017.0142

    authors: Christiansen MP,Klaff LJ,Brazg R,Chang AR,Levy CJ,Lam D,Denham DS,Atiee G,Bode BW,Walters SJ,Kelley L,Bailey TS

    更新日期:2018-03-01 00:00:00

  • Safety and Efficacy of Initializing the Control-IQ Artificial Pancreas System Based on Total Daily Insulin in Adolescents with Type 1 Diabetes.

    abstract:: Objective: To assess the safety and efficacy of a simplified initialization for the Tandem t:slim X2 Control-IQ hybrid closed-loop system, using parameters based on total daily insulin ("MyTDI") in adolescents with type 1 diabetes under usual activity and during periods of...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2019.0471

    authors: Schoelwer MJ,Robic JL,Gautier T,Fabris C,Carr K,Clancy-Oliveri M,Brown SA,Anderson SM,DeBoer MD,Cherñavvsky DR,Breton MD

    更新日期:2020-08-01 00:00:00

  • Efficacy and safety performance of the Innovo insulin doser.

    abstract::Innovo (Novo Nordisk A/S, Hillerød, Denmark) is a new insulin injection system that offers built-in memory and a large, clear display to provide patients with more control during insulin injections. The aim of this trial was to compare the efficacy and safety of Innovo and NovoPen 3 (Novo Nordisk A/S) in patients expe...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1089/152091504322783413

    authors: Valk NK,Cerny G,Sieber J,Lytzen L,Berg B

    更新日期:2004-02-01 00:00:00

  • Peripheral leptin levels in narcoleptic patients.

    abstract:BACKGROUND:Narcolepsy is a severe sleep disorder that in most patients is characterized by the deficiency of central orexin. Clinically, narcolepsy is associated with obesity. Currently, there is a literature controversy about the potential alteration of leptin levels in narcoleptic patients. Theoretically, diminished ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2006.0037

    authors: Dahmen N,Engel A,Helfrich J,Manderscheid N,Löbig M,Forst T,Pfützner A,Tonn P

    更新日期:2007-08-01 00:00:00

  • Accuracy and reliability of continuous glucose monitoring systems: a head-to-head comparison.

    abstract:OBJECTIVE:This study assessed the accuracy and reliability of three continuous glucose monitoring (CGM) systems. RESEARCH DESIGN AND METHODS:We studied the Animas® (West Chester, PA) Vibe™ with Dexcom® (San Diego, CA) G4™ version A sensor (G4A), the Abbott Diabetes Care (Alameda, CA) Freestyle® Navigator I (NAV), and ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1089/dia.2013.0049

    authors: Luijf YM,Mader JK,Doll W,Pieber T,Farret A,Place J,Renard E,Bruttomesso D,Filippi A,Avogaro A,Arnolds S,Benesch C,Heinemann L,DeVries JH,AP@home consortium.

    更新日期:2013-08-01 00:00:00

  • Self-monitoring of blood glucose in diabetes: from evidence to clinical reality in Central and Eastern Europe--recommendations from the international Central-Eastern European expert group.

    abstract::Self-monitoring of blood glucose (SMBG) is universally considered to be an integral part of type 1 diabetes management and crucial for optimizing the safety and efficacy of complex insulin regimens. This extends to type 2 diabetes patients on intensive insulin therapy, and there is also a growing body of evidence sugg...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2013.0302

    authors: Czupryniak L,Barkai L,Bolgarska S,Bronisz A,Broz J,Cypryk K,Honka M,Janez A,Krnic M,Lalic N,Martinka E,Rahelic D,Roman G,Tankova T,Várkonyi T,Wolnik B,Zherdova N

    更新日期:2014-07-01 00:00:00

  • Daily glucose profiles in Japanese people with normal glucose tolerance as assessed by continuous glucose monitoring.

    abstract:BACKGROUND:Little information is available regarding glucose fluctuations in postprandial states and during the oral glucose tolerance test (OGTT) in Japanese people with normal glucose tolerance (NGT). METHODS:Glucose profiles of 27 Japanese people were measured for 4 days by using continuous glucose monitoring. A 75...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2008.0083

    authors: Tsujino D,Nishimura R,Taki K,Miyashita Y,Morimoto A,Tajima N

    更新日期:2009-07-01 00:00:00

  • Performance evaluation of the MiniMed continuous glucose monitoring system during patient home use.

    abstract:BACKGROUND:The recent availability of a continuous glucose monitor offers the opportunity to match the demands of intensive diabetes management with a period of equally intensive blood glucose monitoring. The present study evaluates the performance of the MiniMed continuous glucose monitoring system (CGMS) in patients ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/152091500316737

    authors: Gross TM,Bode BW,Einhorn D,Kayne DM,Reed JH,White NH,Mastrototaro JJ

    更新日期:2000-04-01 00:00:00

  • Management of patients with diabetes through information technology: tools for monitoring and control of the patients' metabolic behavior.

    abstract:BACKGROUND:The junction of telemedicine home monitoring with multifaceted disease management programs seems nowadays a promising direction to combine the need for an intensive approach to deal with diabetes and the pressure to contain the costs of the interventions. Several projects in the European Union and the United...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2004.6.567

    authors: Bellazzi R,Arcelloni M,Ferrari P,Decata P,Hernando ME,García A,Gazzaruso C,Gómez EJ,Larizza C,Fratino P,Stefanelli M

    更新日期:2004-10-01 00:00:00

  • Effectiveness of Automated Insulin Management Features of the MiniMed® 640G Sensor-Augmented Insulin Pump.

    abstract:BACKGROUND:Automated insulin management features of the MiniMed® 640G sensor-augmented pump system include suspension in response to predicted low sensor glucose (SG) values ("suspend before low"), suspension in response to existing low SG values ("suspend on low"), and automatic restarting of basal insulin delivery up...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2016.0216

    authors: Zhong A,Choudhary P,McMahon C,Agrawal P,Welsh JB,Cordero TL,Kaufman FR

    更新日期:2016-10-01 00:00:00

  • Impact of glycemic control on heart rate variability in youth with type 1 diabetes: the SEARCH CVD study.

    abstract:AIM:This study explored the role of glycemic control on cardiac autonomic function, measured by heart rate variability (HRV), in youth with type 1 diabetes. PATIENTS AND METHODS:A retrospective cohort of 345 youth with type 1 diabetes (mean age, 18.5 years; duration, 10 years) participating in the SEARCH for Diabetes ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究

    doi:10.1089/dia.2013.0147

    authors: Jaiswal M,Fingerlin TE,Urbina EM,Wadwa RP,Talton JW,D'Agostino RB Jr,Hamman RF,Daniels SR,Marcovina SM,Dolan LM,Dabelea D

    更新日期:2013-12-01 00:00:00

  • Reviewing U.S. Connected Diabetes Care: The Newest Member of the Team.

    abstract::Recent years have brought about an explosion in the number of companies offering connected diabetes care products, defined as digital diabetes management systems based around (1) smartphone apps, (2) devices with built-in connectivity, and (3) remote human and automated coaching and support. These nascent models aim t...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2019.0273

    authors: Levine BJ,Close KL,Gabbay RA

    更新日期:2020-01-01 00:00:00

  • Development of a Collaborative Algorithm for the Management of Type 2 Diabetes during Ramadan: An Anchor on Empowerment.

    abstract::Empowerment plays significant roles in the complex management of type 2 diabetes. International guidelines have provided recommendations on management of Muslims who fast during Ramadan. However, there remains a lack of patient-centered epistemic tool to empower healthcare providers and patients in managing diabetes d...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2018.0159

    authors: Lum ZK,See Toh WY,Lim SM,Rusli KDB,Abdul Shakoor SAKK,Tsou KYK,Chew DEK,Dalan R,Kwek SC,Othman N,Lian JX,Lee JY

    更新日期:2018-10-01 00:00:00

  • A Real-World Prospective Study of the Safety and Effectiveness of the Loop Open Source Automated Insulin Delivery System.

    abstract:OBJECTIVE:To evaluate the safety and effectiveness of the Loop Do-It-Yourself (DIY) automated insulin delivery system. RESEARCH DESIGN AND METHODS:A prospective real-world observational study was conducted, which included 558 adults and children (age range 1 to 71 years, mean HbA1c 6.8±1.0%) who initiated Loop either ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2020.0535

    authors: Lum J,Bailey R,Barnes-Lomen V,Naranjo D,Hood K,Lal RA,Arbiter B,Brown A,DeSalvo DJ,Pettus J,Calhoun P,Beck RW

    更新日期:2020-11-23 00:00:00

  • A pilot study of the SPRINT protocol for tight glycemic control in critically Ill patients.

    abstract:BACKGROUND:Stress-induced hyperglycemia is prevalent in critical care, even in patients with no history of diabetes. Increased counter-regulatory hormone response increases gluconeogenesis and effective insulin resistance, which can be exacerbated by drug therapy. Control of blood glucose levels to the 4.0-6.1 mmol/L r...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2006.8.449

    authors: Lonergan T,Compte AL,Willacy M,Chase JG,Shaw GM,Hann CE,Lotz T,Lin J,Wong XW

    更新日期:2006-08-01 00:00:00

  • Virtual Coaching to Enhance Diabetes Care.

    abstract::Rates of diabetes are increasing worldwide and there is not a sufficient clinical workforce to care for these patients. Diabetes-related apps are a feasible way to provide diabetes education to large numbers of people with diabetes but attrition rates are high. Apps enhanced by virtual coaching may be a way to circumn...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2019.0016

    authors: Ramchandani N

    更新日期:2019-06-01 00:00:00

  • NerveCheck for the Detection of Sensory Loss and Neuropathic Pain in Diabetes.

    abstract:BACKGROUND:Accurate and economic detection of nerve damage in diabetes is key to more widespread diagnosis of patients with diabetic peripheral neuropathy (DPN) and painful diabetic neuropathy. This study examined the diagnostic performance of NerveCheck, an inexpensive ($500) quantitative sensory testing (QST) device....

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2016.0279

    authors: Ponirakis G,Odriozola MN,Odriozola S,Petropoulos IN,Azmi S,Ferdousi M,Fadavi H,Alam U,Marshall A,Jeziorska M,Miro A,Kheyami A,Tavakoli M,Al-Ahmar A,Odriozola MB,Odriozola A,Malik RA

    更新日期:2016-12-01 00:00:00

  • Behavioral Patterns and Associations with Glucose Control During 12-Week Randomized Free-Living Clinical Trial of Day and Night Hybrid Closed-Loop Insulin Delivery in Adults with Type 1 Diabetes.

    abstract:OBJECTIVES:We evaluated patterns of meal intake, insulin bolus delivery, and fingerstick glucose measurements during hybrid closed-loop and sensor-augmented pump (SAP) therapy, including associations with glucose control. METHODS:Data were retrospectively analyzed from pump-treated adults with type 1 diabetes who unde...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2016.0307

    authors: Emami A,Willinska ME,Thabit H,Leelarathna L,Hartnell S,Dellweg S,Benesch C,Mader JK,Holzer M,Kojzar H,Pieber TR,Arnolds S,Evans ML,Hovorka R

    更新日期:2017-07-01 00:00:00

  • Biochemical stabilization of glucagon at alkaline pH.

    abstract:BACKGROUND:For patients with type 1 diabetes mellitus, a bihormonal artificial endocrine pancreas system utilizing glucagon and insulin has been found to stabilize glycemic control. However, commercially available formulations of glucagon cannot currently be used in such systems because of physical instability characte...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2014.0047

    authors: Caputo N,Jackson MA,Castle JR,El Youssef J,Bakhtiani PA,Bergstrom CP,Carroll JM,Breen ME,Leonard GL,David LL,Roberts CT Jr,Ward WK

    更新日期:2014-11-01 00:00:00